HomeMy WebLinkAboutFloor Plan0 I I 00 Safe Load Table Notes 1. All values based on minimum 4" nominal bearing. Exception: Safe loads for unfilled U lintels must be reduced by 20% if bearing length is less than 6 1 /2". 2. N.R. = Not Rated 3. Safe loads are superimposed allowable loads. 4. One #7 rebar may be substituted for two #5 rebar in 8 inch U lintels only. 5. All safe loads in units of pounds per linier foot. 6. All safe loads are based on simply supported span. 7. Safe load ratings based on rational design analysis per ACI 318 and ACI 530. Composite U Lintel Materials 1. Grout per ASTM C476 fg=3000 psi with maximum 3/8 inch aggregate and 8 to 11 inch slump. 2. Rebar per ASTM A615 Grade 60 3. Concrete masonry units (CMU) per ASTM C90 with minimum net area compressive strength = 1900 psi 4. Mortar per ASTM C270 Type M or S 16" 12'-8"" 7'-6" 5'-2„ L-8 Installation Notes 1. Installation of U lintels must comply with architectural and/or structural drawings. 2. U lintels can be field cut to the required length. 3. Cast in place concrete may be provided in composite U lintel in lieu of concrete masonry units. 4. The exterior surface of U lintels installed in exterior concrete masonry walls shall have a coating of stucco applied in accordance with ASTM C-926 or other approved coating. 5. Concrete masonry units used in composite U lintel shall be laid in a running bond. 6. Shore composite lintels as required. 7. U lintels are manufactured with a 5 1 /2" long notch at both ends to accomodate vertical cell reinforcing and grout. 43'-4"" 16" 12'-8" 6'-11 "" 5'-9", #5 r bar at top in. (1) req'd. quanity of #5 rebar CV at bottom of lintel \ cavity r— F= filled grout ffi nominal OO = width C.M.. Lo .E °ut L'? 8F16-1B/1T embo—d .astcrete t.1 J n1. 7 quanity of #5 ebar at bottom nominal rebar at top parity heigtn 8" Nominal Lintel Type Designation 68'-8" 16" 12'-8"" 1'-10"" 10'-1„ W 0 16" Cast Crete Lintel Schedule All Rebar to be #5 Grade 60 min. MARK LENGTH OF LINTEL ALLOWABLE GRAVITY LOAD APPLIED GRAVITY LOAD ALLOWABLE UPLIFT LOAD APPLIED UPLIFT LOAD BEAM SPECS. L-1 T-8"" 6113 121 4853 100 8F16-1B/1T L-2 4'-6"" 6113 1732 2724 1053 8F16-1 B/1 T L-3 7'-6 2661 577 1634 300 8F16-1 B/1 T L-4 4'-2"" 5206 488 2635 286 8RF14-1B/1T L-5 T-8" 1568 1042 931 632 8RF14-1B/1T L-6 5'-10- 4360 233 2093 171 8F16-1B/1T L-7 8'-0" 1843 125 1133 149 8F16-1B/1T L-8 14'-0" 1002 54 559 281 8F16-1B/1T L-9 8'-8"" 1843 540 1133 654 8F16-1B/1T L-10 11'-8- 1254 157 723 186 8F16-1B/1T Min. Beam depths shown, beams may be increased without comment At Lintels over 24"" deep provide (1) #3 vertical rebar at 24"o.c. along length of lintel 25'-4"" E EL ------------ -------- ] °----------- a ° o a -00 -------------------- 0 0 I I I I I I a.c. cond. on 4"" \� Porch ;� I I conc. pad. Fasten �-7 unit to concrete00 o L-7 I 9'-0""Ceiling _� I using the metal Well from F.F.E. ( anchor flange by Pump I I manufacturer with I coo L_2 24 �-4 � I 1/4"" x 3"" tapcons typical (4) � $ h N ( places HB �-5 - 0� 0� �-5 0� 0 � E _ d.w. I j [Ed: 7[]] 0g1-0" Cing. o / wh on 1 Bdrm. 3 1\ pan / 9'-0""Ceiling Master Bdrm. I Dining `-1 Kitchen ' ti�Lnd. 9'-0""Cing. with 12""Coffer I 9'-0""Cln g• �� I 9'-0 Ceiling O J, t(J -� 9'-0'" ❑w rod N 9 . g a� co Range & tr Exh. Hood O L102668 d 6 2' 2"" 12'-0 r 22.5 x 36 v.t.r. I Attic Acc. 0 ❑ 25 s.h. Pantry I I Egress 8 16'-3"" 11'-2- T-0"" T-4„ 2'-3„ T-9„ 3 4„ 5' 11 „ L�-2 L ' " Ref. C000 _ to I ner co `n - - 2668 a.h. N N l� CI g' .� L_---- -----i --- I �Oro��� `"� 2868 I `n I9,-0- ,N 0 L-6 N HB 44 C, Cing. M 'u) 32 s.h. 'o �r I g _0" Safety 'o M M 3'-6"" 2'-6-2'-11 "" 3'-6"" T-6"" I N I 1 c) (0 N to Cing. (� J) l� Glass Cn " 9'-0"" o `V HB p�R' Cing. N 00 00 � Vault Ceiling Ridge N Office r10 cl1 g'-0" Great Room 9'-0""Ceiling 3'-2"" 8'-6"" ' " Cing. 2.5/12 Pitch Cing. 0 a 0 112 I - T-6" 2'-0- 4'-2" T-5"" 2'-2" 23,-4" 14'-9„ 12'-0" H34 s.h. d 0 Safety — Glass .Glass Bdrm. 2 Tern f i "' 60�"x 36""Tub m Deck 'co I I Enclosure 9'-0" Ceiling �-5 Septic �--2 25 s.h. Safety 25 FL-�3s.h. 25 s.h. 25 s.h. Egress 25 s.h. L-3 �--2 25 s.h. o Egress Egress System Glass HB C) Cz Hook Up � Entry � [E-9 I T-0""Ceiling from F.F.E. �-9 0 I I I I I 00 I — — — — — — — — --------------------------- --------- I -------- Project Data Project Name: Jesus Monaco Street Address: XXXX City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New one level CBS single family residence Design Loads Roof Live Load: 20.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 2901 s.f. Building Code 2020 Florida Building Code: Residential 2017 National Electric Code NFPA 70 Area Tabulation Living 2267 Porch 346 Entry 288 Total 2901 Cubic Volume: 22,697 c.f. Climatic & Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 5V METAL ROOFING OVER PEEL & STICK UNDERLAYMENT 12 OVER 5/8- C.D.X. PLYWOOD -� 5 SEE CONNECTOR PRE ENG. WD. SCHEDULE TRUSSES 24""c.c. -, ALUM. DRIP EDGE ON 1 x2P.T.ON2x6 CEDAR FASCIA STUCCO SOFFIT WITH 8" x 16" SCREEN VENTS 8'-0 o.c. LEVEL RETURNS BY TRUSS MFG. PROVIDE-CASTCRETE" PRECAST LINTELS ABOVE ALL OPENINGS TWO COAT STUCCO FINISH OVER CBS GRADE a R30 BATT INSUL. 1 /2" D.W. 1 x 4 P.T. FIRESTOP 8 x 16 x 8 C.M.U. WITH #5 VERT. DOWEL -1 IN GROUT FILLED CELLS 1 x 2 P.T. FURRING 24-o.c. 3/4- INSULATION BRD. ON C.B.S. 1 /2- GYP. D.W. 1 x 4 P.T. FIRESTOP F-1 4- 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL Typical Wall Section 0- � cr) O / IL L1.! M Z -� � O U-) W Q (D i LO 00 .� Q L.- F- 0 N U z W a � o .� �_ _> i. W LID 0 = M Q) ♦♦4J vJ 4) �. > < (� U UJ cc U, J . —1 r- In O N *- noo •- 4 �ozN T N I\ UJ 00 T C 0 V i 0 0 U 0 E NRi L.1.. 0 0 V 0 Cn 1C ._.6 1-2 'A date revision ` * j 2Q drawn FILE Copy 5.1. checked S.I. date 8/27/21 scale as noted job number 21032 sheet Floor Plan A-1 scale: 1 /4" = V-0" I scale: 1/4" Project Data Project Name: Jesus Monaco Street Address: XXXX City: Ft. Pierce County: St. Lucie State: Florida Scope of Work New one level CBS single family residence Design Loads Roof Live Load: 20.0 p.s.f. Wind Speed: 160 MPH Wind Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent: .18 Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. Building Data Occupancy Type: Group R Construction Type: V Number of Stories: One Project Area: 3423 s.f. Building Code 2020 Florida Building Code: Residential 2017 National Electric Code NFPA 70 Area Tabulation Living 2294 Garage 757 Porch 293 Entry 288 Total 3632 Cubic Volume: xxxx c.f. Climatic ....& Geographic Design Criteria Weathering: Negligible Termite Area: Very Heavy Flame Spread Index & Smoke Developed Index Insulation Flame Spread: Not to exceed 25 Insulation Smoke Developed Index: Not to exceed 450 Wall Finishes: Not greater than 200 Ceiling Finishes: Not greater than 200 5V CRIMP METAL PANELS OR FIBERGLASS SHINGLES OVER PEEL & STICK UNDERLAYMENT 12 OVER 5/8"" C.D.X. PLY°JUQQD SEE CONNECTOR t/ PRE ENG. WD. SCHEDULE TRUSSES 24-c.c. ALUM. DRIP EDGE ON R30 BATT INSUL. Ix2P.T.ON2x6 CEDAR FASCIA I `- STUCCO SOFFIT\ -I x 4 P.T. I/2" D.W. WITH 8" x 16" FIRESTOP SCREEN VENTS (2) COURSE BOND LEVEL RETURNS BEAM WITH (1) #5 BY TRUSS MFG. 1'-� REBAR FILLED WITH Ir GROUT EACH COURSE PROVIDE "CASTCRETE PRECAST LINTELS ABOVE ALL OPENINGS TWO COAT STUCCO FINISH OVER CBS GRADE 4 8x16x8C.M.U. WITH #5 VERT. DOWEL IN GROUT FILLED CELLS 1 x 2 P.T. FURRING 24"o.c. 3/4`" INSULATION BRD. ON C.B.S. 1/2" GYP. D.W. 1 x 4 P.T. FIRESTOP 4" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL _Typical Wall Section C N op 0 �■ W � co z -cl o `o CD b.0 ti cc Q w Q i I Uj 0o r_ in J . ,. < LL rn i- U c w a O .J iz w 0 > a) 4 0 -I� C 0 0 E 0 M 0 (1� 0 z Cn U) drawn s.l. checked SA. date 7/20/21 , scale - as noted job number 21032 sheet A— 1 PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. Verify all dimensions with the floor plan. The floor plan dimensions dictates all other dimensions on other sheets. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. All sanitary lines 2" or less shall have a slope of 1 /4" per foot minimum. All sanitary lines above 2- shall have a slope of 1 /8" per foot minimum. Provide Anti -Scalding Valve in all showers. Lowest living area floor elevation (refered as 0.00') to be set by a professional land surveyor to the required building department elevation, but not less than 18" above the crown of the road. 2" v.t.r. 2"' v.t.r. I 2" v.t.r. 2 v.t.r. 1 1 /2" I I I 2" v.t.r. f I I Sink I I I 2„1 I I I I I LAV LAV Washer LAV 2" 3„ Sink 3"• W.C. 2„ Tub 3 W.C. 3" 2" 3 3„ 3„ 2" v.t.r. 3" 2„ C.O. Shwr. JI I 4" LAV j I Plumbing contractor to provide a 1 to sewer water hammer & shut off valve at 2 system each fixture Insulate all hot water lines 3„ Plumbing Riser Diagram W.C. 2 J U Shower 3" 0 00 68'-8"' 0 0 F-1 0 F-1 F-1 0 F1 o � - F1 I $ N 3'-2" 3'-10" I F-1 0 bo 4"2500# I Conc. Pad II 1 -4„ F-5 '[']1E1 1104 0 0 F-5 0 0 0 0 F-5 0 0 F-1 0 I F-1 C* _M i E co I � l M —� o 0 i I F-4 4'" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER I , ON CLEAN, COMPACTED, 'm I c� TERMITE TREATED FILL -4„ � F-1I o l Cl)I I ASSUMED F.F.E. 0.00 0 Cl) fill T-81 8 N I Un 0 F-1 0 0 10'-8" 6'-3" 'M FIE -------------------------------- LO 0 F-1 Cl 0 0 0 F-4 0 0 F-5 0 F-5 0 0 0 F-5 I 0 0 0 F-1 0 LO 0 -4" 2'-10"" T-0"' 4'-8'" T-4"` 4'-4" T-0" 2'-10" o F-1 ( F-1 .. F-1 .. F-1 .. F-1 .. 5'-0"" 16'" 3'-10"" 1 6'-2" 0121 10'-8"° 1121 10'-8'° 1121 10'-8" 112 5`11'" 4'-6"' 1 5'-11 16'-4°' 36'-0" 16'-4" Foundation & Footing Plan scale: 1 /4" = V-0"' F-1 F-5 F-4 18" x 16" mono. footing Recess 4- at Shower with (2) #5 rebar cont. 18" x 16" mono. footing 8„ with (2) #5 rebar Cont. 4_ 4� 16 "" 4 4 L8_ 16„ 18"18- 8 18" TYP. SHOWER MONO. EDGE FOOTING INTERIOR STEP FOOTING RECESS FORMWORK & SHORING No structural concrete shall be stripped until it has reached at least 80% of the 28 day design strength. Design, Erection, & Removal of all formwork, shores, & reshores shall meet meet the ACI Standards 347 and 301 Contractor to verify all building setbacks prior to the start of construction. A formboard survey shall be submitted to the building department for approval prior to pouring concrete. SOIL STATEMENT: Foundation has been designed for a soil bearing capacity of 2000 p.s.i Fill shall be laid in layers of 6". Each layer to be compacted to 95% compaction. If the contractor encounters, while digging the foundation, any discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer so as to order a soil boring test. Dowel Rod Repair Note In the event vertical steel has been omitted from the down pour locations, drill 5" into concrete (no closer than 3 3/4" from edges and 5" from ends of cap walls) Remove dust per manufacturers instructions and use Two part epoxy to anchor the #5 rebar in place. Use either "'Hilti C-100" or Simpson Epoxy -Tie. GENERAL FOUNDATION NOTES Concrete shall be a minimum of 4" thick over clean, compacted, termite treated fill and 6 mil polyethylene vapor barrier. If concrete slab contains 6" x 6"' 10/10 WWM provide 1" coverage Concrete shall have at minimum compressive strength of not less than 3,000 p.s.i. All 90% hooks are to be extended 10'" minimum beyond the turn. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six bar diameters. Minimum coverage for rebar shall be 3" in footings and 1 1 /2" in bond beams. Hooks may be rotated horizonitally if required to achieve minimum coverages. Rebar overlap shall be 48 bar diameters. 30" for #5 rebar The foundation design assumes that the soil has a minimum load carrying capacity of 2000 p.s.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superseded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1 /8" per foot for drainage v �. CV 00 M C W .4- CM Z -6 oLO LL 441 LU Q i 00 O _J � AN 1 Q ` \/ ~ N 0 Z W EL- L_ o . — 0 U > > W M C) O M d' 4-) F_ > Q cu U LO ,� r- / O00 N r ■ �y LlUOzN �r T (n ~ Q � O U L O C/) V O C: U O C Cn O = E N tU NO L.L date revision drawn s.l. checked s.l. date 8/27/21 scale as noted job number 21032 sheet A-2 01� Top of Wall to Soffit Front Elevation scale: 1/4"" = 1'-0"" Rear Elevation scale: 1 /4" = 1'-0- Open � Open Left Elevation scale: 1 /4"" = 1'-0- Open 00 h Open 7-1 Right Elevation scale: 1 /4"" = 1'-0" Roof Ridge Wind Zones - Walls 3/8" continuous bead of caulk (back bedding) behind buck to prevent liquid passage set flange in continuous bead of caulk across the entire face of buck a� W �Ooc Jo�F00 a oW=� o M-00 M li v o .a - -1�- 18'-0- — T.O.B. � 91_0„ Window Head F.F.E. 0.00' 4' :rr 3 3 I 2E 13 3 12E \ 1 / \ 2R \ \ / 213 � — \ \ 2\ / 2R R / % 2E 1 / 2R 2R �r 2R 2R cr 13 2E I 3 — / I / /2R / 2R < 1 2E / 2R / J 2R 2R — — :— —� \ \ / 2R / / \ \ 2R 2R \ 2R ^ 2R \ \ \ 3 3 2E / 2R / \ 2R \ 2E CBS Min. 1 1 /4"" embedment a a at windows and min. d 1 1 /2" embedment at d a ° d sl. gl. doors d ° 1 /2" drywall stucco finish -� � 1 perimeter caulk 1 /4" max. struct. shim Attach p.t. bucks with 8d coil nails at caulk 12" o.c. attach as per Typ. Alum. window manufacturers jamb or sliding glass product approvals door jamb NOTE: Method of attachment and Gunable sealants shall comply with waterproofing procedures are the ASTM C 920 Class 25 grade or same at poured concrete sill. greater for proper joint expansion and contraction Window & Door Flashing Detail at CBS Wall Includes Buck Attachment Method 1 2E / / \ \ ( 2E 3 3 ( 2E 13 3 Roof Wind Zones Alum. window frame 3/8"" continuous bead of caulk (back bedding) behind shim to prevent liquid passage 1 /4"" struct. shi set flange in continuous bead of caulk across the entire face of buck perimeter caulk stucco finish --, corrosive resistant Tapcon concrete srews installed as specified in window manufacturers product approval ►w sill Protecto LWM200 precast J Coating on Outside face cons. sill and Janbs of Openings all Sides min. 8 Gunable sealants shall comply with ASTM C 920 Class 25 grade or greater for proper joint expansion and contraction Typical Precast Conc. Sill Detail 9-0--$ — - Bottom Cord of Truss 2 x 4 top plate ",1 /2" gyp. d.w. 2 x 4 studs 24-o.c. No. 3 Stud Grade 2 x 4 p.t. sill plate wood base Cased Hard Coil Nails 12"o.c. max. \_ Concrete Foundation Interior Wall Section Optional Non Load Bearing Walls U 0. C-4 00 ® ry W d' CM V Z -� U O LL 40 � W N 00 J a n LL U Z w 0- L- O w `:) 0 > rn WIt a� VJ cu > Q M > U LLJ to LO . C r LO It N �_ �oz (0 n N Q UJ U 00 CY) C 0 U (1) U C cU O C: 20 0 � CD NNCU L.L. O X date I revision ,'ten FV, s.l. nt checked s.l. date 8/27/21 scale as noted job number 21032 sheet A-3 Ceramic Tile Shall be installed in accordance with ANSI A108.1, A108.4, A108.5 A108.6, A108.11, A118.1, A118.3, A136.1, & A137.1. Fiber mat reinforced backer shall be used behind wall applied ceramic tiles in the tub and shower areas and conform to ASTM C1325. Per Durock, cement board exceeds ASTM C1325. STRUCTURAL NOTES: All reinforcing steel shall be high strength billet steel and shall conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30- in beams and in slabs. Lap bottom steel over supports and top steel at midspan. Hook discontinuous ends of all top bars. Reinforcing steel shall have a minimum of 1 "r concrete cover, or as follows: BOTTOM TOP SIDES GENERAL ROOFING NOTES Roofing to be composed of and attached to pre manufactured wood trusses as follows: Felt underlayment (min. ASTM 0 226 Type II) with 4- min. side and end laps, fasten with coorosion resistant annular ring shank nails at 6r o.c. in laps and in staggered rows spaced 12" o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. Gypsum Note 5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips, Beams: 1 1 /2" 1 1 /2- 1 1 /2- nailed to trusses with 8d corrosion resistant annular ring shank nails Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047 Slab on Grade: 1 1/2- 1" _ Structural Poured: 3/4"" 3/4"spaced max. 6��o.c. throughout, except max. 4"�o.c. at gable ends. C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential Poured Walls: _ _ 3/4- All roof trusses are to be pre -manufactured assemblies provided by a licensed wood truss fabricator with seperate drawings and data code. Per USG, Wallboard conforms to C1396. Slabs exposed to the weather 3/4" 1 "" prepared for actual project conditions by a Florida registered Gypsum Board & Gypsum Panel Products Gypsum board and gypsum panel products shall be applied at right angles or parallel to framing members. All edges and ends of gypsum board and gypsum panel products shall occur on framing members, except those edges and ends that are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to weather or to water. Wall and ceiling gypsum board shall be fastened with screws spaced at 12-o,c. Screws for attaching gypsum board and gypsum panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 andshall penetrate thewood not less than 5/8- inch (15.9mm) Gypsum board and Gypsum panel products shall be attached to cold formed steel framing less than 0.033- (1 mm) thick shall be Type S in accordance with ASTM C1002 or bugle head style in accordance with ASTM C1513 and shall penetrate the steel not less than 3/8" to 0.112- (1 mm to 3mm) thick shall be in accordance with ASTM C954 or bugle head style in accordance with ASTM 1513. Screws for attaching gypsum board or gypsum panel products to structural insulated panles shall penetrate the wood structural panle facing not less than 7/16`ro.c. (11.1 mm). Gypsum board used as the base orbacker for adhesive application of ceramic tile or other required nonabsorbent finish material shall conform to ASTM C1396, C1178, C1278. Use of water resistant gypsum backing board shall be permitted on ceilings. Water resistant gypsum board shall not be installed over a Class 1 or Class 2 vapor retarder in a shower or tub compartment. Cut or exposed edges, including those at wall intersections, shall be sealed as recommended by the manufactuer. Water resistant gypsum backing board shall not be used where there will be direct exposure to water, or areas subject to continuous high humidity. Cold Formed Steel Note Cold formed steel framing supporting gypsum board and gypsum panel products shall be not less than 1 1 /4- (32mm) wide in the least dimension. Non Load bearing cold formed steel framing shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 and ASTM C955, Section 8. Wood Framing Note Wood framing supporting gypsum board and gypsum panel products shall be not less than 2" (51 mm) nominal thickness in th least dimension except that wood furring strips not less than 1 " by 2" (25mm x 51 mm) nominal dimension shall be permitted to be used over solid backing or framing spaced not more than 24-o.c. (610mm) Wire Lath Attachment Over wood framing the paper backed wire lath shall be installed over one layer of approved plastic house wrap. Lath shall be attached horizontal framing members with 1.5" roofing nails and to vertical wood framing members with 6d common nails or 1 roofing nails driven to penetration of not less then 3/4" of an inch, or 1 wire staples driven flush with the plaster base. Staples shall have crowns not less than 3/4" and shall engage not less than three strands of lath and penetrate the wood framing members not less than 3/4if. The fasteners must penetrate the wood framing members not less than 3/4". Fasteners shall be 7" o.c. max. EXTERIOR CEILING & SOFFIT NOTE 7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to framing members with No. 11 guage nails with 1 3/4- embed. with 3/8- dia. head 6"o.c. max. edges to be tied and nailed at 9-o.c. Install one layer of 15# felt to framing prior to installing ribbed lath INTERIOR WALL FRAMING NOTE Interior non bearing walls to be 2 x 4 studs 24"o.c. Spruce, Pine, Fir (SPF) #3 Grade lumber or better or metal studs (25 Ga.) Crimper may be used in lieu of screws. BUCK ATTACHMENT NOTES AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH TO BLOCK WITH 1 /4" DIA. TAPCONS INTO C.B.S. SET AT 6- FROM CORNERS AND AT 12"o.c. MAX. AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS OR -T- NAILS" 4" FROM ENDS AND 12"o.c. USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION THRESHOLD NOTE At egress door (see floor plan) the max. hgth. of the threshold shall be 1 /2" professional engineer certified for truss design. Any deviation from Reinforcing steel shall be detailed and fabricated in accordance "Manual the proposed plans as shown regarding placement or bearing shall be brought to the attention of the truss engineer prior to fabrication with the of Standard Practice of Detailing Reinforcing -ACI of the trusses. The truss manufacturer's certified layout shall govern Concrete Structures" and the current Building Code 318- after fabrication. All structural steel shall conform to current ASTM Specification A-36 The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. All wood in contact with masonry shall be pressure treated or approved drawings and data. seperating material. All engineered headers and truss hangers to be provided by the truss manufacturer. All dimensions shall be verified in field by the contractor. If there are any discrepancies the Architect or Engineer shall be notified before Splitting or cracking of structural components due to installation of proceeding. hardware is not permitted. Unless otherwise noted, the installation of specified hardware shall No slump over 5" shall be permitted for any structural concrete without conform to the truss manufacturers installation instructions and the Architect or Engineer approval. standard practice. All Design and Construction shall be inaccordance with the current American Concrete Institute (ACI). and the American Institute of Steel Construction (AISC), The Florida Building Code and all applicable local codes. Structural Concrete shall attain a minimum ultimate compressive strength (Fe') in 28 days as follows: Column Footing and Wall Footing: 3000 p.s.i. Column and walls from foundation to roof. see column schedule. All other concrete: 3000 p.s.i. Footing sizes and reinforcing are based on allowable soil bearing capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this is not the case, the Architect or Engineer shall be notified before proceeding with the work. Timber (Heavy Timber Construction) (a) Truss manufacturer shall submit a signed and sealed shop drawings by a registered Engineer. (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. (c) Roof members should be secured to the beams or other structural components with hurricane anchors for wind uplift. All wood members shall have a minimum fiber stress in bending of 1200 p.s.i. with 1 /360 max. deflection. All bolted connections shall be 1 /2- Cadmium plated or better. Lag bolts to be used only in shear connections with minimum 4- threaded penetration past steel plate. Lag bolted conditions shall be drill tapped no larger than the internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder plys at frame bearing locations GENERAL REQUIREMENTS All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, and all other cost related to the completion of this project., unless explicitly identified here. Owner is responsible for all municipal related charges such as impact fees, and water connection, except building permit fees, which are to be included in the construction bid. General contractor to check all drawings for errors and ommissions and bring them to the attention of the architect prior to starting any work, or ordering any materials of the respective division of work. If such errors and ommissions are not reported in writingto the architect, any resulting damages or costs shall be born entirely by the general contractor. Architect is not responsible for the contractors method or means of construction. General contractor is to keep the site in a clean and safe state through out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department and the building permit has been issued. SHEATHING NAILING NOTES Nailing Pattern Zone 1: 8d at Vo.c. field & 4-o.c. edges Zone 2: 8d at 4"o.c. edges & field Zone 3: 8d at 4"o.c. edges & field Pneumatic Nails Pneumatic or mechanicaly driven nails will be accepted under the following conditions: Min. nails size 8d or larger ring shank with Min. shank diameter:.113 Min. Length: 2" Min. Head Diameter:.280 Full Round Min. Ring Diameter .012 over shank dia. Min. 16 to 20 Rings per Inch Note Gun nails shall be permitted as an acceptable fastener from any manufacturer Wood screws meeting the same size requirement may be used in lieu of nails without comment Nailing Schedule ROOF & FLOOR DIAGRAM Use sheathing with #8 gun nails at 6"o.c. at supported panel edges and #8 gun nails at 6"o.c. at intermediate supports. ROOF SHEATHING TO GABLE END FRAME Use #8 gun nails at 4"o.c. EXTERIOR SHEATHING Use #8 gun nails at 4"o.c. at panel edges and #8 gun nails at 4"o.c. at panel top and bottom and 6-o.c. in field 2 x 4 bottom cord hraclnLr 10'-0" Bottom Cord Lateral Bracing Connector Schedule Truss Bearing Truss Connector Gnty. Connector Fasteners Point Uplift ID Uplift GIRD 2 1812 1 Ply HHETA20 1 2,120 (10) 10d x 1 1/2" 10 1816 2 (1) 5/8" dia. A.T.R. Drilled and GRE 2,720 MGT 1 3,965 Epoxy into Grouted Bond Beam 10 2 Ply 12"min. embedment & (22) 10d to truss. (1) 5/8""dia. A.T.R. Drilled and GRG 15 2,984 MGT 1 3,965 Epoxy into Grouted Bond Beam 2 Ply 12"min. embedment & (22) 10d to truss. GRK 15 1823 HHETA20 1 2,120 (10) 10d x 1 1/2"" 1 Ply All other trusses ALL <1810 HETA20 1 1810# (9) 10d x 1 1 /2" to CBS Supporting (4) 10d Valley Framing <250# VTCR 1 370# valley (3) 10d x 1 1/2- Trusses Truss The Bearing Point Numbers on the Connector Schedule Match with the Bearing Locations on the Truss Manufacturer's Profile Sheets Roof Truss Placement Plan scale: 1 /4- = 1'-0- Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place 0 Fri Attach valley trusses and piggy back trusses, if present, to main trusses per truss manufacturer drawing. Q. N Truss to truss connection by truss company, installed :3 O Cn 00 � per manufacturers specs. M W Lateral forces perpendicular and parallel to wall has been Z N considered (less than 300 p.l.f.) OLO Contractor to approve temporary bracing to prevent topplingbO LL of trusses, see HIB-9. wLO Others specs, if different from above have priority. p p Y 4 v N 00 i— A.T.R. = All Treaded Rod Q J G" N Drill and Epoxy Set all A.T.R. . _ Q W Use either-Hiltirr C-100 or Simpson Epoxy Tie Epoxy �. a' 0 w O Missed Tie Down Strap Note U In the event the Tie Down Strap has been omitted from the _� _> Layout location, install one HTSM20 strap at the proper location. Q� W O Fasten with (4) 1/4" x 2 1/4- Hex Head Titen screw to C.B.S. and (10) 10d to truss. MAXIMUM UPLIFT 1175 lbs. > Nt 4) 4-J Attic Vents Calculation Attic Area: 2901 s.f. / 150 = 19.3 s.f. required. soffit area = 247.0 I.f. x 1.5 = 371 s.f. Venting Provided: 8 x 16 soffit vent: 85 sa. in. each vent Q (� U W r- d• LO � � N T co 00 O Z U N LU Q 00 T O U cu C O Cn C/) drawn checked s.l. date 8/27/21 scale as noted job number 21032 sheet A-4 (3) #4/0 (THW) copper and (1) #2 ground (THW) copper in 2 galy. conduit Panel: 200 A.M.C-B- 1200 Amp 1,6, 3W 40 Circuit )I Panel 120/240 Volt a.c. disc. 5/8"" dia. x 10'-0"" -1-% long ground rod 3/4" copper water pipe (3) #4/0 (THW) copper and (1) #2 ground (THW) copper in 2" galy. conduit F.P.L. service \_tie ground wire to footing rebar � p 5 ar lad all Electrical Load Calculations ZZb / Living S.F. at :3 VA OW i watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Range 8000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Dryer @ 5 kw 5000 watts Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts Water Heater 8500 watts Total 43,801 watts First 10 KVA at 100% 10,000 watts One AC Heat at 100% 10,000 watts Total 33,520 watts 33,520 W ,/ 240 V = 140.0 Amps Use 200A Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified i s P- l 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipment and disconnects, Typical. IJ 3w Master Brdrm, I i Fan & Light I I i MAI scale: 1 /4"" = V-0"" Porch Ft e g-fp q_ LLJ gflty Dining Kitchen gfi FF Ref. I Great Room / Fan & Light Light 0 Pantry ❑� IVwp gFi Entry Electric �Uwh Panel Lnd. a d pc in attic I Fl) \"Ix Fan & Light Office na 1 r> k.. Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures Head: 6"max. from corners & 13"max. o.c. Jambs: 6"max. from NOA: 17-1212.21 S.H. Windows 7700 Lawson Impact corners 10"max. o.c. above meeting rail & 9"o.c. below meeting rail & 3""each side of meeting rail.. Use 1/4"" Tapcon with 1 1/4"" +38.7 -50.5 +/-60.0 embedment into concrete Head and Sill: 5.75""and 11.75 from corners & 12,75"max. o.c. NOA: 18-0503.06 French Door 2200 Lawson Impact Jambs: 5-max. and 17""o.c. max. o.c. Use 5/16 Tapcon with +34.4 -37.8 +/-76.0 1 1 /2"" embedment into concrete. 6"" from corners & 14.5""o.c. at Jambs. Head and Sill 3"" and FL#: 20468.4 Swing Doors Fiberglass Therma-Tru N.A. 7"" from centerline. Use 1 /4"" Tapcon with 1 1 /4"" embedment +34.4 -37.8 +/- 50.0 into concrete 6"" from corners & 14.5""o.c. at Jambs. Head and Sill 3" and FL#: 20468.12 Swing Doors Fiberglass Therma-Tru Impact 7"" from corners & centerline. Use 1 /4"" Tapcon with 1 1 /4"" +34.4 -37.8 +/- 50.0 embedment into concrete Approval Product Model Nu b6r Manufacturer Attachment Method Building Rated Product Rated Number Design Pressures Design Pressures FL#:22259.1 Underlayment Beacon Tri Built 5V Crimp Owens Corning Direct to Deck -45.0 -150.0 FL#: 14645.2 Roofing Metal Sales Mfg. #10-14 hex head screws with sealing washer along panel 12"o.c. Fastener -45.0 -149.6 to penetrate the plywood a minimum of 3/8". �' Well Pump drrn. 3 Fan & Light i Fan & Light ra wp o gfi Meter ELECTRICAL LEDGEND ,(O, RECESSED LIGHT WITH LENS 4 EXTERIOR & WET LOCATIONS }- SURFACE MOUNTED LIGHT FIXTURE T{--- ) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ® UNDER CABINET FLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN WITH LIGHT OPTION COMBO. ®CARBON MONOXIDE SMOKE DETECTOR EXHAUST FAN OUTLET O MOTION SENSOR T THERMOSTAT ON SWITCH DUPLEX OUTLET - SWITCHED P1119 DOOR CHIMES DUPLEX OUTLET SMOKE DETECTOR 220 V OUTLET -(yr SWITCH -I+ TELEVISION -yr THREE WAY SWITCH -Q TELEPHONE 3w -6pr DIMMER SWITCH PUSH BUTTON D NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS OWNER TO CORRDINATE LOCATIONS OF TELEPHONES AND TELEVISIONS IN FIELD WITH CONTRACTOR K. M , x `L L Itt � N co N r, LL Z ,.I - O F d ..j= %.. co z ..0 date revision 12/8/21 Plan Review Comments drawn 51 checked date 8/27/21 scale as noted job number 21032 sheet