Loading...
HomeMy WebLinkAboutProduct Approval Diagram(3) #4/0 (THW) copper and (1) #2 ground (THW) copper in 2 galy. conduit Panel: 200 A.M.C.B. 200 Amp 1,6, 3W 40 Circuit Panel 120/240 Volt 1 O disc. (3) #4/0 (THW) copper and (1) #2 ground (THW) copper in 2" galy. conduit 5/8"" dia. x 10'-0 F.P.L. service long ground rod N3/4"" copper water pipe 1 MM tie ground wire to footing rebars I Riser la Electrical Load Calcu'lations 2267 Living S.F. at 3 VA 6801 watts One 20 Amp Appliance Ckts. 1500 watts Two Laundry Cir. @ 1500 watts 3000 watts One Range 8000 watts One Dishwasher & One Disposal @ 1500 watts each 3000 watts One Microwave @ 2000 watts 2000 watts One Dryer @ 5 kw 5000 watts Ref. @ 1500 watts 1500 watts Three Baths @ 1500 watts each 4500 watts Water Heater 8500 watts Total 43,801 watts First 10 KVA at 100% 10,000 watts Remainder at 40% 13,520 watts Total 23,520 watts One AC Heat at 100% 10,000 watts Total 33,520 watts 33,520 W / 240 V = 140.0 Amps Use 200A Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified c r^ Elect£ a-� %" 1. All loads to be checked by a Florida Licensed Electrician Z All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipment and disconnects, Typical. wp Septic System Hook Up Electric y scale: 1/4`" = 1'-0" PR0E," Approval Glass Building Rated Product Rated Product Model Number Manufacturer Attachment Method Number Type Design Pressures Design Pressures Head: 6"max. from corners & 13-max. o.c. Jambs: 6-max. from NOA: 17-1212.21 S.H. Windows 7700 Lawson Impact corners 10"max. o.c. above meeting rail & 9-o.c. below meeting rail & 3-each side of meeting rail.. Use 1 /4"" Tapcon with 1 1 /4"" +38.7 -50.5 +/-60.0 embedment into concrete Head and Sill: 5.75"and 11.75 from corners & 12.75"max. o.c. NOA: 18-0503.06 French Door 2200 Lawson Impact Jambs: 5""max. and 17`"o.c. max. o.c. Use 5/16"" Tapcon with +34.4 -37.8 +/-76.0 1 1 /2"" embedment into concrete. 6"" from corners & 14,5""o.c. at Jambs. Head and Sill 3- and FL#: 20468.4 Swing Doors Fiberglass Therma-Tru N.A. 7- from centerline. Use 1 /4"" Tapcon with 1 1 /4"" embedment +34.4 -37.8 +/- 50.0 into concrete 6"" from corners & 14.5-o.c. at Jambs. Head and Sill 3"" and FL#: 20468.12 Swing Doors Fiberglass Therma-Tru Impact 7"" from corners & centerline. Use 1 /4"" Tapcon with 1 1 /4"" +34.4 -37.8 +/- 50.0 embedment into concrete Approval Building Rated Product Rated Product Model Number Manufacturer Attachment Method Number Design Pressures Design Pressures FL#:22259.1 Underlayment Beacon Tri Built Owens Corning Direct to Deck -45.0 -150.0 FL#: 14645.2 Roofing 5V Crimp Metal Sales Mfg. #10-14 hex head screws with sealing washer along panel 12"o.c. Fastener -45.0 -149.6 to penetrate the plywood a minimum of 3/8 . Meter ELEC i RIGAL LEDGEND j0 RECESSED LIGH T WITH LENS (9 EXTERIOR & WET LOCATIONS SURFACE MOUN`rED LIGHT FIXTURE Tf-- T) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ® UNDER CABINETFLUORESCENT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN WITH LIGHT OPTION COMBO. 0 CARBON MONOXIDE 0 EXHAUST FAN OUTLET SMOKE DETECTOR O MOTION SENSOR T THERMOSTAT ON SWITCH DUPLEX OUTLET - SWITCHED ff9 DOOR CHIMES DUPLEX OUTLET S® SMOKE DETECTOR 220 V OUTLET �t SWITCH -F+ TELEVISION yr THREE WAY SWITCH -Q TELEPHONE 3w -rtjD - DIMMER SWITCH PUSH BUTTON NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFCI MUST BE AFCI. TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS OWNER TO CORRDINATE LOCATIONS OF TELEPHONES AND TELEVISIONS IN FIELD WITH CONTRACTOR St. tuc e Permit �� my i a� > I 00 v cv rW e'N date revision / ' � 12/8/21 Plan Review Comments drawn s.l. checked s.l. date 8/27/21 scale as noted job number 21032 sheet