HomeMy WebLinkAboutProject Information-1d- Wrightsofta Project Summary Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com For: Jesus Monaco XXX Southwind Trail, Fort Pierce, FL 34951 Notes: besign Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27496 Btuh Structure 23373 Btuh Ducts 7180 Btuh Ducts 8750 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh e) Humid fication 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34676 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 30517 Btuh Infiltration Equipment sensible load Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4328 Btuh Ducts 2794 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 2294 2294 Equipment latent load 7122 Btuh Volume (ft3) 22697 22697 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 37639 Btuh Equiv. AVF (cfm) 121 61 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1642AJl NA AHRI ref Coil RH1T4821STANJA AHRI ref 7942888 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 10.0 kW Sensible cooling 29050 Btuh - Heating output 34286 Btuh Latent cooling 12450 Btuh Temperature rise 23 OF Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r' wrightsoft'• 2021JuM 10:11:44 / ••�_-•- - --•� - --� RightSuite®Universal 2019 19.021 RSU08101 Page 1 ACCK ...1DocumentslWrightsoft HVAC1Monaco Residence.rup Calc = MJ8 Front Door faces: W uvrightsoft- Right-M Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Master Bedroom 2 Exposed wall 176.0 ft 40.0 ft 3 Room height 9.9 ft 12.0 ft heat/cool 4 Room dimensions 1.0 x 287.0 ft 5 Room area 2294.0 f? 287.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ftk" (Btuhfft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13A-4ocs OA43 n 4.00 2.19 393 385 1542 842 276 ° 276 1105 604 I-G 1A-r1om 1.270 n 35.56 26.39 8 0: 284 211 0 0 0 0 T 13A-4ocs 0.143 a 4.00 2.19 384 276 1105 604 204 156 625 341 10A-m 1.670 a 46.76 34.58 96 128 4489 3320 48 32 2244 1660 �C 11 1A-r1om 1.270 a 35.56 26.39 12 24 427 317 0 0 0 0 13A4ocs, 0.143 's 4.00, 2.19 306 283 1133 619 0 0 0 0 1A-rlom 1.270 s 35.56 26.39 = . 8 . 16 284, 211 0 0 0 0 -G t--G 1A-r1om 1.270 s 35.56 26.39 15 30 633. 396 0 0 . 0 0 VV� 13A4ocs 0.143 w 4.00 2.19 621 483 1934 1057 0 0 0 0 1A-r1om 1.270 w 35.56 52.68 30 0 1067 1580 0 0 0 0 1A-r1om 1.270 w 35.56 26.39 60 120 2134 1583 0 0 0 0 D 11DO. 0.390 w 10.92 10.34 48 48. 524 496 0 0 0 0 C 16B-30ad 0.032 - 0.90. 1.60 1790 1790 1604 2864 287 287. 257 459 C 17B-6ai 0.105 - 2.94 4.30 625 625 1837 2690 0 0 0 0 F 22A7tpl 0.989. - 27.69 0.00. 2294 176 4874 0 287 40 1108 0. 6 c) AED excursion 1515 -123 Envelope loss/gain 23771 18305 5339 2942 12 a) Infiltration 3725 998 1049 281 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 9 2070 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 27496 23373 6388 3683 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 4 7 14 Subtotal 27496 23373 6393 3690 15 Duct loads 26% 37% 7180 8750 26% 37% 1669 1381 Total room load 34676 32123 8062 5072 Air required (cfm) 1383 1383 322 218 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4ja- 2021-Jul-2310:11:44 RightSuite®Universal 2019 19.0.21 RSU08101 Pagel \DocumentslWrightsoft HVAC\Monaco Residence.rup Calc = MJ8 Front Door faces: W Wrightsoft, Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall 2 M WIC 2 Exposed wall O ft O ft 3 Room height 9.0 It heat/cool 9.0 It . heat/cool 4 Room dimensions 4.0 x 6.0 ft 9.0 x 9.0 It 5 Room area 24.0 ft2 81.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ft') Load number (Btuh/ft=°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat 7 Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13A-4ocs' 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 ,1A-r1om 1.270. n 35.56 26.39 0 0 0 0 0- 0 0 0 _G 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1OA-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 1A-rlom 1.270 a 35.56 26.39 0 0 0 0 0 0 0 0 13A-4oc, 0:143 s 4.00 2.19 0' 0 0 0 0 0 0' 0: 1A-rlom 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 1A-r1om I.m s 35.56 26.39 0 0 :. 0 0 0 0 0 0 13A-IA-rI ocs w 4.56 2.68 0 0 0 0 0 0- 0 0 IA-rlom 1.270 1.270 w 35.56 52.68 0 0 0 0 0 0 0 0 1A-rlom 1.270 w 35.56 26.39 0 0 0 0 0 0 0 0 D IIDO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0:032 0.90 1:60 24 24 22 38 81 81 73 130 C 17B-6al 0.105 2.94 4r30 0 0 0 0 0 0_ 0 0 F 22A-tpl 0.989 27.69 0.00 24 0 0: 0 '81 0 0 0' 61 c) AED excursion -1 -4 Envelope loss/gain 22 371.731 125 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 22 37 73 125 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -22 -37 6 11 14 Subtotal 0 0 79 137 15 Duct loads 26% 37% 0 0 26% 37% 21 51 7 Total room load T I 0 100 E88 Air required (cfm) 0 07 10 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -0w wrl9he �ott� 2021-Jul-23 10:11:44 14 -•^--�-- ••-^-- " RightSuite®Universal 2019 19.0.21 RSU08101 Paget ,ACGA ...\Documents\Mghtsoft HVAC\Monaoo Residence.rup Calc = MJB Front Door faces: W -r+- wlrightsoft' Right-M Worksheet Date: Entire House Date: By. Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Master Bath Dining 2 Exposed wall 27.0 ft 8.0 ft 3 Room height 9.0 ft heat/Goo] 9.0 ft heat/cool 4 Room dimensions 1.0 x 169.0 ft 8.0 x 12.0 ft 5 Room area 169.0 ft' 96.0 ft' Ty Construction U-value Or HTM Area UP) Load Area (ft') Load number (Btuh/ft'° (Btuhfft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IL 13AAocs 0.143 n 4.00 2.19 90 82 328 179 0 0 0 0 � G 1A-r.1om 1.270 n 35.56 26.39 8 0 284" 211 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 72 24 96 53 10A-m 1.670 a 46.76 34.58 0 0 0 0 48 32 2244 1660 11 1A-r1om 1.270 a 35.56 26.39 0 0 0 0 0 0 0 0 V)/ 13A 40cs 0.143 s 4.00 2.19 ' 0 .01 0 0 ', 0 A 0 0 IA-rlom - 1.270 s 35.56 26.39 0 0. 0 0 0 0 0 0 IL-_GG 1A-r1om 1.276 s 35.56 26.39 .0 - 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 153 138 553 302 0 0 0 0 1A-r1om 1.270 w 35.56 52.68 15 0 533 790 0 0 0 0 1A-r1om 1.270 w 35.56 26.39 0 0 0 0 0 0 0 0 D 11 D0 0.390 w 10.92 10.34 0 0. 0 0 0 0 0, 0 C 16B-30ad 0.032 - 0:90 1.60. 169 169 151 270 96. - 96 86 154; C 17B-6aI 0.105 - 2.94 4.30 0 0 0, 0 0 0. 0 0 F 22A-tpl 0.989 - 27.69 0.00 169 27 748 0 96 8 222 0 6 c) AED excursion 205 -69 Envelope loss/gain 1 2598 1958 2648 1797 12 a) Infiltration 531 142 157 42 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 3129 2101 2806 2069 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 4 7 0 0 14 Subtotal 3133 2108 2806 2069 15 Duct loads 26% 37% 818 789 26% 37% 733 775 Total room load 3952 2897 3538 2844 Air required (cfm) 158 125 141 122 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -fia- wrYgtas-.ats 2021-Jul-2310:11:44 RightSuite®Univer:a12019 19.0.21 RSU08101 Page \Documents\Wdghtsoft HVACWonaco Residence.rup Cale = MJ8 Front Door faces: W - - Wrightsoft` Right-M Worksheet Job:. Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickceics@aol.com 1 Room name Kitchen Great Room 2 Exposed wall 12.0 ft 24.0 ft 3 Room height 9.0 ft heat/cool 11.4 ft heat/cool 4 Room dimensions 12.0 x 12.0 ft 24.0 x 21.0 ft 5 Room area 144.0 ft' 504.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'-F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 13A4ocs 0.143 ,: n- ..... ,4.00 2.19 " 0 `0 , 0.; 0 0 0 . .,0, 0 G IA-rlom 1.270 n 35.56. " 26.39 0 0 0 0. 0= 0 0 0 13A-4ocs 0.143 a 4.00 2.19 108 96 384 210 0 0 0 0 10A-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 1A-rlom 1.270 a 35.56 26.39 12 12 427 317 0 0 0 0 13A flocs 0.143 s '. 4.00 2:19 0 0 0 0 0. 0 0 0 IA-rlom . 1Xr1om .. 1.270 1.270 ' s s 35:56 '35.56 26.39 26.39 0 0 0 0;. 0 0 - "• 0 0 0 0 0 :. .. 0 ." 0 0 .. 0 0 0.143 w 4.00 2.19 0 0 0 0 216 138 553 302 1A-r1om 1.270 w 35.56 52.68 0 0 0 0 0 0 0 0 1513A-4ocs 1A-rlom 1.270 w 35.56 26.39 0 0 0 0 30 30 1067 792 D 11130, 0.390 w" 10.92 10.34 0 0. 0 0 48 48 _ 524 496 C 16B-30ad 0.032 - 0.90 1.60 144 144 129 230 0. 0 - 0 0 C F 17B-6al 22A-tp1 0.105 0.689' ` _ 2.94 27.69 4.30 ', 0.00 0. 144 , 0 '12 0 332 , 0 - 0 625 504 , • 625. 24 1837 - 665 2690 0. 61 c) AED excursion -91 674 Envelope loss/gain 1272 666 46451 4953 12 a) Infiltration 236 63 472 126 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 1509 2730 5117 5540 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 14 24 14 Subtotal 1509 2730 5131 5563 15 Duct loads 26% 37% 394 1022 26% 37% 1340 2083 Total room load 1902 3751 6471 7646 Air required (elm) 761 1621 258 329 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A+- v�+rilghtcof�* 2021-Jul-2310:11:44 - ry RightSulte®Unlverml2019 19.021 RSU08101 Page tDocumentslWrightsoft HVACWIonaco Residence.rup Cale = MJ8 Front Door faces: W - - mirightsoft- Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Office Bedroom 2 2 Exposed wall 15.0 ft 28.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 15.0 x 17.0 ft 1.0 x 187.0 ft 5 Room area 255.0 ft' 187.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ftk- F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat 7 Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 v , 13A-4ocs 0.143 n 4.00 2.19 0 0 9 '0 A 0 0 0 1A-r1om 1.270 ' n 35.56 26.39 -• 0 0 0' 0 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 IA-rlom 1.270 a 35.56 26.39 0 0 0 0 0 0 0 0 13A-4ocs 0:143 s 4:00 2.19 -- 0 0 0 0 135 ' 135 541 295 1A-r1om 1A7r1om, 1.270 1.270 • s s 35.56 35.56 26.39 '26.39 0 0 0 , 0 0 - 0.. 0 -.0 0 01 0 0 0 0 0 0. 13A-4ocs 0.143 w 4.00 2.19 135 105 420 230 117 102 408 223 IA-rlom 1.270 w 35.56 52.68 0 0 0 0 15 0 533 790 1A-r1om 1.270 w 35.56 26.39 30 30 1067 792 0 0 0 0 D 11D0 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16830ad 0.032 0.90 f.60 255 _ 255 228 408 187 187 168 299 C 17B-6al 0.105 2.94 4.30 0; 0 0 0 0 0 0 0 F 22A-tpl 0.989: 27.69 0.00 255 15 415 0 187. 28 775 0 61 c) AED excursion 774 228 Envelope loss/gain 2131 2204 2425 1836 12 a) Infiltration 295 79 551 148 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 2426 2513 2976 2214 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 34 59 11 19 14 Subtotal 2460 25721 2987 2232 15 Duct loads 26% 37% 642 963 26% 37% 780 836 Total room load 3103 3534 3767 3068 Air required (cfm) 124 152 150 132 Calculations approved bV ACCA to meet all requirements of Manual J 8th Ed. w� igrstsssf R� 2021-Jul-23 10:11:44 .-. p - - RightSuite@Universal 2019 19,021 RSUD8101 Page ...\Documents\Mghtsoft HVAC\Monaco Residence.rup Calc = MJ8 Front Door faces: W - d- mirightsot=r Right-M Worksheet Job: Entire House Date` By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 2 Bedroom 3 2 Exposed wall 6.0 ft 13.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/000l 4 Room dimensions 9.0 x 6.0 ft 1.0 x 184.0 ft 5 Room area 54.0 ft' 184.0 f? Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load number (Btuh/ft' ° (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs, 0.143 , n 4.00 2.19 0 0 0- 0 0 0 0 0 1A-rlom 1.270 n 35.56 26.39 0 0 0 0 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1OA-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 1A-rlom 1.270 a 35.56 26.39 0 0 0 0 0 0 0 0 13A-4gcS 0:143 s 4.00 2:19 54 46 184 101 117: 102 408: 223: "IA-rlom 1.270 s 3556 26:39 8 8 284 % 211 0 0 .0 0 IA-rlorri .1.270 s -35.56 26.39 0 . 0. 0 0 15 15 533 396 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-riom 1.270 w 35.56 52.68 0 0 0 0 0 0 0 0 IA-rlom 1.270 w 35.56 26.39 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 ' - 0.90 1.60 54 54, 46 86 184 184 165 294 C 17B-6al 0.105 - 2.94 4.30 0 0 0 0 0 0 0 0 F 22A-tpl 0:989 27.69 0.00 54 6 166 0 184. 13. 360 0 6 c) AED excursion -14 -46 Envelope loss/gain 683 384 1467 867 12 a) Infiltration 118 32 256 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 801 416 1722 1395 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 11 19 14 25 14 Subtotal 812 435 1737 1420 15 Duct loads 26% 37% 212 163 26% 37% 454 532 Total room load 1024 597 2190 1952 Air required (cfm) 41 26 87 84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -- wrlght csst�- 2021-Jul-2310:11:44 ^°-� R1ghtSuite®Univers312019 19.021 RSUD8101 Page 1DocumentsUrightsoft HVAC1Monaco Residenoesup Cale = MJ8 Front Door faces: W - - Wrightsoft- Right-M Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By: 1 Room name Hall 1 Laundry 2 Exposed wall O ft O ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 156.0 ft 7.0 x 9.0 ft 5 Room area 156.0 ft' 63.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft'" (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VII ; 13Aocs .... 0.143 n ' . .:. 4:00 219 :. , 0 0 0 ., ..- p 0 p p 0 1A-h1om - 1,270 n :. '35.56 26:39 0 0 0 '' 0 ` 0 0 0 0' -C 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 IA-rlom 13A flocs 1.270 0.143 a s 35.56 4'00 26.39 .' 2:19 0 0 0 U 0 0 0 0 0 0 0 0 0 0 0 0 Val G 1A-glom - 1.270 s 35.56. 26.39 0 .0 0. 0 0 0 0 0 t--G IA -glom 1.270 s• 36.56 ". 26.39 6 0 0 0 0 0 0 0 VVV� 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-r1om 1.270 w 35.56 52.68 0 0 0 0 0 0 0 0 1A-rlom 1.270 w 35.56 26.39 0 0 0 0 0 0 0 0 D 11DO 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0 C 16B30ad --0.032 0.90 _ 1.60 156 156 140 ". - 250 63 63 '. 56 101 C. 17B-6al 0.105 - 2.94 430 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 '- 27.69 O.OD 156 0 0 6 63 0 0 0 61 c) AED excursion -8 3 Envelope loss/gain 140 2421 56 98 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 140 242 56 98 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -140 -242 32 56 14 Subtotal 0 0 89 153 15 Duct loads 26% 37% 0 0 26% 37% 23 57 Total room load 0 0 112 211 Air required (cfm) 0 0 41 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A - wrighr;sofi� 2021-Jul-2310:11:44 w RightSuite®Universal 2019 19.021 RSUD8101 Page tDocuments%Mghtsoft HVACWIonaco Residence.rup Calc = MJB Front Door faces: W - - Wrightsoft- Right-J® Worksheet Job: Entire House Date: Quick Calcs, Inc. By: 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 Room name Pantry Bath 3 2 Exposed wall 0 ft 3.0 It 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 6.0 x 9.0 ft 5 Room area 36.0 f? 54.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuhlft2-°F (Btuhlft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V(! . 13A-4ocs 0.143 n 4.00 2.19 0 '.0 .0 - 0 27 27. 108 59 I-G 1A-rlom 1.270 6 36.56 26.39 0 0 0 0 0 0 0 0' 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 10A-m 1.670 a 46.76 34.58 0 0 0 0 0 0 0 0 11 IA-rlom 1.270 a 35.56 26.39 0 0 0 0 0 0 0 0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 IA-dom 1.270 s 35.56 26.39 0 '. 0 0 0 .. 0 0 0 0 --G G Ikelom - 1.270 s 35.56 26.39 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 w 35.56 52.68 0 0 0 0 0 0 0 0 1A-rlom 1.270 w 35.56 26.39 0 0 0 0 0 0 0 0 D 11DO 0.390 w 10.92 10.34 0 0 0, 0 0 0 0 0 C 16B-30ad 0.032 - -0.90 1:60 36 36:" 32 68 54 54. 48 86' C 17B Gal 0.105 - 2.94 4.30 0 0 0 0 0 0 0 0 . F 22A4pl 0.989 - 27.69 0.00 36 0 0 0 54. 3 83 0 61 c) AED excursion -2 -5 Envelope loss/gain 32 56 240 140 12 a) Infiltration 0 0 59 16 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 56 299 156 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 14 25 16 28 14 Subtotal 47 81 315 184 15 Duct loads 26% 37% 12 30 26% 37% 82 69 Total room load 59 111 397 253 Air required (cfm) 2 51 16 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgh#�ot 2021-Jul-2310:11:44 � - RightSuite®Universal 2019 19.0.21 RSU08101 Page ...1DocumentslWrightsoft HVAC1Monaco Residence.rup Calc = MJB Front Door faces: W In Duct System Summary Job: WCI�h�SOft` y Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com For: Jesus Monaco XXX Southwind Trail, Fort Pierce, FL 34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.293 in/100ft 0.293 in/100ft Actual air flow 1383 cfm 1383 cfm Total effective length (TEL) 171 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 h 1024 41 26 0.380 5.0 Ox 0 VIFx 16.7 115.0 st1 Bath 3 h 397 16 11 0.380 4.0 Ox 0 VIFX 16.4 115.0 st3 Bedroom 2 h 3767 150 132 0.364 7.0 Ox 0 VIFx 22.5 115.0 st1 Bedroom 3 h 2190 87 84 0.379 7.0 Ox 0 VIFx 17.0 115.0 st1 Dining h 3538 141 122 0.293 8.0 Ox 0 VIFX 35.6 135.0 st5 Great Room c 3823 129 165 0.324 8.0 Ox 0 VIFx 39.4 115.0 st4 Great Room -A c 3823 129 165 0.332 8.0 Ox 0 VIFx 35.4 115.0 st4 Kitchen c 3751 76 162 0.293 8.0 Ox 0 VIFX 35.6 135.0 st5 Laundry c 211 4 9 0.379 4.0 Ox 0 VIFx 17.1 115.0 st3 M WIC c 188 4 8 0.301 4.0 Ox 0 VIFx 50.9 115.0 st2 Master Bath h 3952 158 125 0.298 8.0 Ox 0 VIFx 52.5 115.0 st2 Master Bedroom h 4031 161 109 0.295 8.0 Ox 0 VIFx 54.7 115.0 st2 Master Bedroom -A h 4031 161 109 0.306 8.0 Ox 0 VIFX 48.3 115.0 st2 Office c 3534 124 152 0.348 8.0 Ox 0 VIFx 28.7 115.0 st1 Pantry c 111 2 5 0.382 4.0 Ox 0 VIFX 15.8 115.0 st3 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 483 351 0.295 615 12.0 0 x 0 VinlFlx st4 Peak AVF 258 329 0.324 419 12.0 0 x 0 VinlFlx st5 Peak AVF 217 284 0.293 521 10.0 0 x 0 VinlFlx st3 st3 Peak AVF 240 309 0.293 566 10.0 0 x 0 VinlFlx st1 Peak AVF 402 394 0.348 512 12.0 0 x 0 VinlFlx ,, . * V1 right soft- 2021-Jul-2310:11:44 ti. .,�,'- RightSuite® Universal 2019 19.021 RSU08101 Page l AC A ...\Documents\Wrightsoft HVACUdonac o Residence.rup Cale = MJ8 Front Door faces: W n Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (Cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1383 1383 0 0 0 0 Ox 0 VIFx »!�- wrFghkSot ,��„ RightSuite®Universal 2019 19.021 RSU08101 ...1DocumentsUdghtsoft HVAC1Monaco Residenoe.rup Cale = MJ8 Front Door faces: W 2021-JuM 10:11:44 Page 2 - --------- -- ------ ------ Garage emriFE _j ------------ — ----- =ml In Porch F-1 L ----- Bctrrn. 3 Dining en Lod, r 'Wsf "S" F 4C M H l.. } ------. - ---- Great Room M.- - 7 o L' Md. I -chm 2 Nu ni Entry -IT --- -------------- Floor Plan ,,, - Fw— Project Data Building Data p1q— tb— J_ U__ MaONCYTy : Q­R S� Add- XXXX C� T� V C My. FL Pbrc' Wb—fst— One Cower. a lamb . Preset Arse: 3423.f C. :3 S.. Rodd. Building Code Scope of Work 2M S.W. O.0CW,- Rm&,W 0 '�c New me bw:l CBS a'val.fenub M17 NUW Ek,b C.6 HFPJk 70 to a: Design Loads Area Tabulation 0) A! F—fL—L..& 2W.0 Living 2294 'y"d' Garage 757 Porch 293 Er298 C.) MAE— 8 Total .18 Ik0­4.capftr. 2&WP,.L Cub,. W— f > Ca..u. & rk­m. D..im CrKri. FlameFla- S—.d kW- & S.A. Dd Ca— F.odsr FmEacusssm+GlBsovEa12 DVFR wo: oil sEE ES KID BAT[3151a_ T2P.T­2.8 2 SUM M yms, FIT 4 P SCRIEEN VENTS T-o-_ CU cOtYRSE BOND Co 0 C C-) 0 0 Tea COAT 'a MCCaFOM, C'U'CaS WQYP' DW' fY 1 .4 P.T. LF—LI// Loves aaaV. .Nq Typical Wall Section