HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method RECEIVED Project Name: THURSTON RESIDENCE Builder Name: Street: 1845 S JENKINS ROAD Permit Office: JAN 10 "02Z City, State, Zip: FT. PIERCE, FL, Permit Number: at, wolp county Owner: Jurisdiction: Pormi"In Design Location: FL, Fort Pierce County: St. Lucie(Florida Climave Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1328.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1328.00 ftz z 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 11. Ceiling Types(1498.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ftz) 1498 a. Roof Deck (Unvented) b. N/A R=20.0 1498.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz R= ftz 7. Windows(186.0 sqft.) Description Area 12. Ducts, location & insulation level R ftz a. U-Factor: Sgl, U=0.65 107.83 ftz a. a. Sup: Attic, Ret: Attic, AH: UTILITY 6 125 SHGC: SHGC=0.25 b. b. U-Factor: Sgl, U=0.65 74.17 ftz C. SHGC: SHGC=0.30 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.65 4.00 ftz a. Central Unit 26.0 SEER:17.00 SHGC: SHGC=0.28 Area Weighted Average Overhang Depth: 3.388 ft Area Weighted Average SHGC: 0.271 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 17.0 COP:1.00 U-Factor:(AVG) N/A N/A ftz SHGC(AVG): N/A 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 1498.00 ftz a. PropaneTankless Cap: 1 gallons b. N/A R= ftz EF: 0.600 c. N/A R= ftz b. Conservation features None Glass/Floor Area: 0.124 Total Proposed Modified Loads: 43.80 PASS Total Baseline Loads: 49.61 I hereby certify that the plans and specifications covered by Review of the plans and Ti�iE ST ArF this calculation are in compliance with the Florida Energy specifications covered by this pfc Code. ' calculation indicates compliance �v�' %,. ,_ ,: 0 with the Florida Energy Code. PREPARED BY: _ Before construction is completed this building will be inspected for Section 553.908 DATE: compliance with Florida Statutes. ¢ r�COb I hereby certify that t s uildin as d si e , is in co pliance with the Florida Ene gy I , `�.�`�� OWNER/AGE T: (J BUILDING OFFICIAL: DAT DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Proposed Qn of 0.080 exceeds the performance method default limit of 0.08 and therefore does not require duct testing. R405 .2.3 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/6/2022 7:57:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softwar� S� Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: THURSTON RESIDENCE Address type: Street Address Building Type: User Bedrooms: 3 Lot #: --- Owner: Conditioned Area: 1498 Block/SubDivision: -- Total Stories: 1 PlatBook: --- Builder Name: Worst Case: No Street: 1845 S JENKINS ROAD Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1498 11984 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 TLT. 21 168 No 0 Yes Yes Yes -2 M BATH 95 760 No 0 Yes Yes Yes -3 WIC 66 528 No 0 No Yes Yes _ 4 M BEDROOM 273 2184 No 2 1 Yes Yes Yes _ 5 KITCHEN/DINING 280 2240 Yes 0 Yes Yes Yes _ 6 GREAT ROOM 302 2416 No 2 Yes Yes Yes _ 7 UTILITY 96 768 No 0 Yes Yes Yes _ 8 BEDROOM 2 160 1280 No 1 Yes Yes Yes _ 9 BEDROOM 3 165 1320 No 1 Yes Yes Yes 10 BATH 2 40 320 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 1498 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins TLT. 10 0 21 ft 0.473 --- 0.00 1.00 0.00 _ -2 Slab -On -Grade Edge Ins M BATH 17 0 95 ft 0.473 --- 0.00 1.00 0.00 -3 Slab -On -Grade Edge Ins WIC 1 0 66 ft 0.473 --- 0.00 1.00 0.00 _ 4 Slab -On -Grade Edge Ins M BEDROOM 35 0 273 ft 0.473 --- 0.00 1.00 0.00 _ 5 Slab -On -Grade Edge Ins KITCHEN/DINING 20 0 280 ft 0.473 --- 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins GREAT ROOM 20 0 302 ft 0.473 --- 0.00 1.00 0.00 _ 7 Slab -On -Grade Edge Ins UTILITY 8 0 96 ft 0.473 --- 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins BEDROOM 2 25 0 160 ft 0.473 --- 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins BEDROOM 3 26 0 165 ft 0.473 --- 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins BATH 2 5 0 40 ft 0.473 --- 0.00 1.00 0.00 1/6/2022 7:57:37 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1579 ft2 Uhillflished, Galvanizdd 0.6 No 0.7 No 20 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1498 ft2 N N CEILING (Total Exposed Area = 1498 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type _ 1 Under Attic(Unvented) TLT. 0.0 Blown 21.0ft2 0.061 0.10 Wood -2 Under Attic(Unvented) M BATH 0.0 Blown 95.0ft2 0.061 0.10 Wood _3 Under Attic(U nvented) WIC 0.0 Blown 66.0ft2 0.061 0.10 Wood _ 4 Under Attic(Unvented) M BEDROOM 0.0 Blown 273.0ft2 0.061 0.10 Wood _5 Under Attic(Unvented) KITCHEN/DINING 0.0 Blown 280.0ft2 0.061 0.10 Wood _ 6 Under Attic(Unvented) GREAT ROOM 0.0 Blown 302.0ft2 0.061 0.10 Wood _ 7 Under Attic(Unvented) UTILITY 0.0 Blown 96.0ft2 0.061 0.10 Wood _ 8 Under Attic(Unvented) BEDROOM 2 0.0 Blown 160.0ft2 0.061 0.10 Wood _ 9 Under Attic(Unvented) BEDROOM 3 0.0 Blown 165.0ft2 0.061 0.10 Wood 10 Under Attic(Unvented) BATH 2 0.0 Blown 40.0ft2 0.061 0.10 Wood WALLS (Total Exposed Area = 1328 sq.ft.) Cavity Width Height Area U- Sheath Frm. Solar Below VAdjacent # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S Exterior Cone. Blk- Int Ins TLT. 4.1 7.0 0 8.0 0 56.0 0.149 0 0 0.50 0 % -2 W Exterior Cone. Blk - Int Ins TLT. 4.1 3.0 0 8.0 0 24.0 0.149 0 0 0.50 0 % -3 S Exterior Cone. Blk - Int Ins M BATH 4.1 7.0 0 8.0 0 56.0 0.149 0 0 0.50 0 % _ 4 W Exterior Cone. Blk - Int Ins M BATH 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.50 0 % _ 5 E Exterior Cone. Blk - Int Ins M BEDROOM 4.1 21.0 0 8.0 0 168.0 0.149 0 0 0.50 0 % _ 6 S Exterior Cone. Blk - Int Ins M BEDROOM 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.50 0 % _ 7 W Exterior Cone. Blk - Int Ins M BEDROOM 4.1 1.0 0 8.0 0 8.0 0.149 0 0 0.50 0 % _ 8 W Exterior Cone. Blk- Int Ins KITCHEN/DINING 4.1 20.0 0 8.0 0 160.0 0.149 0 0 0.50 0 °% _ 9 E Exterior Cone. Blk - Int Ins GREAT ROOM 4.1 20.0 0 8.0 0 160.0 0.149 0 0 0.50 0 °% _ 10 W Exterior Cone. Blk - Int Ins UTILITY 4.1 8.0 0 8.0 0 64.0 0.149 0 0 0.50 0 °% _ 11 N Exterior Cone. Blk - Int Ins BEDROOM 2 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.50 0 °% 12 W Exterior Cone. Blk - Int Ins BEDROOM 2 4.1 14.0 0 8.0 0 112.0 0.149 0 0 0.50 0 °% _ 13 N Exterior Cone. Blk - Int Ins BEDROOM 3 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.50 0 °% _ 14 E Exterior Cone. Blk- Int Ins BEDROOM 3 4.1 15.0 0 8.0 0 120.0 0.149 0 0 0.50 0 °% _ 15 N Exterior Cone. Blk - Int Ins BATH 2 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.50 0 °% DOORS (Total Exposed Area = 20 sq.ft.) / Width Height ` V # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E Exterior Insulated GREAT ROOM None 0.39 3.00 0 6.00 8 20.0ft2 1/6/2022 7:57:37 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 186 sq.ft.) Wall ----- Overhang ----- V# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _ 1 W 4 Vinyl Low-E Single Yes 0.65 0.28 Y N 4.0ft2 1.0 ft 0 in 1.0 ft 5 in None None -2 E 5 Vinyl Low-E Single Yes 0.65 0.25 Y N 30.0ft2 1.0 ft 0 in 1.0 ft 5 in None None _ 3 W 8 Vinyl Low-E Single Yes 0.65 0.25 Y N 9.0ft2 1.0 ft 0 in 1.0 ft 5 in None None -4 W 8 Vinyl Low-E Single Yes 0.65 0.30 Y N 40.0ft2 1.0 ft 0 in 1.0 It 5 in None None -5 E 9 Vinyl Low-E Single Yes 0.65 0.30 Y N 34.2ft2 14.0 ft 0 in 1.0 ft 5 in None None _ 6 W 10 Vinyl Low-E Single Yes 0.65 0.25 Y N 9.0ft2 1.0 ft 0 in 1.0 ft 5 in None None _ 7 N 11 Vinyl Low-E Single Yes 0.65 0.25 Y N 12.0ft2 1.0 ft 0 in 1.0 ft 5 in None None -8 W 12 Vinyl Low-E Single Yes 0.65 0.25 Y N 17.9ft2 1.0 ft 0 in 1.0 ft 5 in None None _ 9 N 13 Vinyl Low-E Single Yes 0.65 0.25 Y N 12.0ft2 1.0 ft 0 in 1.0 ft 5 in None None 10 E 14 Vinyl Low-E Single Yes 0.65 0.25 Y N 17.9ft2 1.0 ft 0 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00025 999 54.79 102.86 0.0902 5.0 All MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 TLT. -2 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 M BATH _ 3 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 WIC -4 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 M BEDROOM -5 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 KITCHEN/DINING _ 6 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 GREAT ROOM _ 7 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 UTILITY -8 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 2 _ 9 Default(8 Ibs/sq.ft.) 0 ft2 O ft 0.30 BEDROOM 3 10 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 BATH 2 HEATING SYSTEM # System Type Subtype AHRI # Efficiency Capacity ----Geothermal HeatPump--- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Strip Heat None COP: 1.00 17.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:17.0 25.0 750 0.70 sys#1 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Propane Tankless Exterior 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 87 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1/6/2022 7:57:37 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM(Continued) 1 No NA NA NA No NA NA NA None DUCTS ---------Supply------ -------Return-------- Air CFM 25 CFM 25 HVAC # JDuct # Location R-Value Area Location . R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 125 ft2 Attic 6.0 65 ft2 Proposed Qn UTILITY -- -- 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [I Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [I Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 60 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 _ PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 _ PM 68 68 68 68 68 68 68 68 68 68 68 68 1 /612022 7:57:37 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THURSTON RESIDENCE Builder Name: Street: 1845 S JENKINS ROAD Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/6/2022 7:57:58 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1