HomeMy WebLinkAboutEnergy Efficiency Code91 r F0'RW60AA-20.04R EnergyGaugeO 4.5 w FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs ,Residential Whole Building Performance Method A Project Name: MORGAN RESIDENCE Builder: Address: Permitting Office: st. lucie City, State: Permit Number: Owner: Jurisdiction Number: 61100 Climate Zone: Central 1. New construction or existing Addition _ 2. Single family or multi -family Single family 3. Number of units, if multi -family 1 _ 4. Number of Bedrooms 4 _ 5. Is this a worst case? No _ 6. Conditioned floor area (ft2) 3614 ft2 7. Glass type I and area: (Label reqd. _ by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 603.0 ft2 b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint) 603.0 ft2 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 322.0(p) ft _ b. N/A c. N/A _ 9. Wall types _ a. Frame, Wood, Adjacent R=11.0, 249.0 W _ b. Frame, Wood, Exterior R=11.0, 1861.0 ft2 c. Frame, Wood, Exterior R=19.0, 317.0 ft2 _ d. N/A e. N/A _ 10. Ceiling types _ a. Under Attic _ R=30.0, 3614.0 ft2 b. N/A c. N/A _ 11. Ducts _ a. Sup: Unc. Ret: Unc. AH: Garage _ Sup. R=6.0, 250.0 ft b. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 150.0 ft 12. Cooling systems a. Central Unit b. Central Unit c. N/A 13. Heating systems Cap: 58.0 kBtu/hr _ SEER:13.00 _ Cap: 17.0 kBtu/hr _ SEER: 13.00 a. Electric Heat Pump ap: 56.0 kBtu/hr HSPF:8.00 _ b. Electric Heat Pump : 16.0 kBtu/hr _ HSPF:7.70 _ c. N/A 14. Hot water systems a. Electric Resistance Cap: 50.0 gallons _ b. N/A EF: 0.95 _ c. ConvXcrt 15. ry, Solar heat pump) (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.17 Total as -built points: 37165 PASS Total base points: 38966 I hereby certify that the plans pecifi tions c r d by this calculation are in com a with t FI gy Code. PREPARED BY• DATE: � 6 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER_ /AGENT: BATE• 4-- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: MZ-C, PT, -1.Predominant glass type.`For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.5) FORM 600A-2004R EnergyGauge@ 4.5 .4 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 3614.0 24.35 15840.0 1.Single, Tint N 2.0 7.0 144.0 24.46 0.92 3255.0 2.Single, Tint N 2.0 6.0 69.0 24.46 0.90 1524.0 3.Single, Tint N 17.0 6.0 16.0 24.46 0.61 239.0 4.Single, Tint N 6.0 9.0 128.0 24.46 0.79 2465.0 5.Single, Tint E 2.0 6.0 115.0 53.27 0.85 5236.0 6.Single, Tint W 6.0 6.0 32.0 47.90 0.54 835.0 7.Single, Tint W 2.0 6.0 46.0 47.90 0.85 1881.0 8.Single, Tint S 2.0 6.0 23.0 39.84 0.80 731.0 9.Single, Tint S 2.0 6.0 30.0 39.84 0.80 953.0 As -Built Total: 603.0 17119.0 WALL TYPES Area X BSPM = Points Type R-Value ea X SPM = Points Adjacent 249.0 0.70 174.3 1. Frame, Wood, Adjacent 1 2 0.70 174.3 Exterior 2178.0 1.90 4138.2 2. Frame, Wood, Exterior 1861. 1.90 3535.9 3. Frame, Wood, Ext rior 0 317.0 1.00 317.0 Base Total: 2427.0 4312.6 As -Built Total: 2427.0 4027.2 DOOR TYPES Area X BSPM = Points T r e Area X SPM = Points Adjacent 21.0 1.60 33.6 1.Ext for Insulated 48.0 4.80 230.4 Exterior 48.0 4.80 230.4 2.Adjacent Insulated 21.0 1.60 33.6 Base Total: 69.0 264.0 As -Built Total: 69.0 264.0 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 3614.0 2.13 7697.8 1. Under Attic 30.0 3614.0 2.13 X 1.00 7697.8 Base Total: 3614.0 7697.8 As -Built Total: 3614.0 7697.8 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 322.0(p) -31.8 -10239.6 1. Slab -On -Grade Edge Insulation 0.0 322.0(p -31.90 -10271.8 Raised 0.0 0.00 0.0 Base Total: -10239.6 As -Built Total: 322.0 -10271.8 INFILTRATION Area X BSPM = Points Area X SPM = Points 3614.0 14.31 51716.3 3614.0 14.31 51716.3 EnergyGauge® DCA Form 60OA-2004R EnergyGaugeO/FIaRES'2004 FLRCSB v4.5 FOAR 600A-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT Summer Base Points: 69591.1 Summer As -Built Points: 70552.6 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 58000btuh ,SEER/EFF(13.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS) 70553 0.77 (1.09 x 1.150 x 1.00) 0.260 0.902 16004.0 (sys 2: Central Unit 17000btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS) 70553 0.23 (1.08 x 1.150 x 0.90) 0.260 0.902 4190.7 69591.1 0.3250 22617.1 70552.6 1.00 1.200 0.260 0.902 19867.3 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FOF M 600A-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 3614.0 9.11 5926.0 1.Single, Tint N 2.0 7.0 144.0 15.38 1.00 2206.0 2.Single, Tint N 2.0 6.0 69.0 15.38 1.00 1056.0 3.Single, Tint N 17.0 6.0 16.0 15.38 0.98 242.0 4.Single, Tint N 6.0 9.0 128.0 15.38 0.99 1952.0 5.Single, Tint E 2.0 6.0 115.0 13.04 1.03 1544.0 6.Single, Tint W 6.0 6.0 32.0 13.80 1.08 478.0 7.Single, Tint W 2.0 6.0 46.0 13.80 1.02 648.0 8.Single, Tint S 2.0 6.0 23.0 10.88 1.12 279.0 9.Single, Tint S 2.0 6.0 30.0 10.88 1.12 364.0 As -Built Total: 603.0 8769.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 249.0 1.80 448.2 1. Frame, Wood, Adjacent 11.0 f.49.0 1.80 448.2 Exterior 2178.0 2.00 4356.0 2. Frame, Wood, Exterior 2.00 3722.0 3. Frame, Wood, Exterior Q1.0 7.0 1.10 348.7 Base Total: 2427.0 4804.2 As -Built Total: 24 7.0 4518.9 DOOR TYPES Area X BWPM = Points Type L' 4 t;. Area X WPM = Points Adjacent 21.0 4.00 84.0 uia 48.0 5.10 244.8 Exterior 48.0 5.10 244.8u Jdjak 21.0 4.00 84.0 Base Total: 69.0 328.8 uilt Total: 69.0 328.8 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 3614.0 0.64 2313.0 1. Under Attic 30.0 3614.0 0.64 X 1.00 2313.0 Base Total: 3614.0 2313.0 As -Built Total: 3614.0 2313.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 322.0(p) -1.9 -611.8 1. Slab -On -Grade Edge Insulation 0.0 322.0(p 2.50 805.0 Raised 0.0 0.00 0.0 Base Total: -611.8 As -Built Total: 322.0 805.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 3614.0 -0.28 -1011.9 3614.0 -0.28 -1011.9 EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 r w FORM 600A-2004R EnergyGauge@ 4.5 L ' WINTER CALCULATIONS Residential Whole Building Performance Method A - Details a ADDRESS: , , , PERMIT #: BASE AS -BUILT Winter Base Points: 11748.2 Winter As -Built Points: 15722.7 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 56000 btuh ,EFF(8.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0 15722.7 0.778 (1.078 x 1.160 x 1.00) 0.427 0.950 6197.7 (sys 2: Electric Heat Pump 16000 btuh ,EFF(7.7) Ducts:Unc(S),Con(R),Int(AH),R6.0 15722.7 0.222 (1.068 x 1.160 x 0.92) 0.443 0.950 1676.9 11748.2 0.5640 6508.5 15722.7 1.00 1.209 0.430 0.960 7768.7 EnergyGaugeTA° DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM600A-2004R EnergyGauge® 4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: ... PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2460.00 9840.0 50.0 0.95 4 1.00 2382.32 1.00 9529.3 As -Built Total: 9529.3 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 22617 6509 9840 38966 19867 9529 37165 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5 FORM 600A-2004R EnergyGauge® 4.5 ~ Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion sp a comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exc�ede by all sid cis.) 10 ® Tov COMPONENTS SECTION REQUIREME CHECK Water Heaters 612.1 Comply with e ' cLsin Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric r cuas must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5