HomeMy WebLinkAboutEnergy Efficiency Code91
r F0'RW60AA-20.04R EnergyGaugeO 4.5
w
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
,Residential Whole Building Performance Method A
Project Name: MORGAN RESIDENCE
Builder:
Address:
Permitting Office: st. lucie
City, State:
Permit Number:
Owner:
Jurisdiction Number: 61100
Climate Zone: Central
1. New construction or existing
Addition _
2. Single family or multi -family
Single family
3. Number of units, if multi -family
1 _
4. Number of Bedrooms
4 _
5. Is this a worst case?
No _
6. Conditioned floor area (ft2)
3614 ft2
7. Glass type I and area: (Label reqd.
_
by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT)
7a(Sngle Default) 603.0 ft2
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Tint) 603.0 ft2
8. Floor types
a. Slab -On -Grade Edge Insulation
R=0.0, 322.0(p) ft _
b. N/A
c. N/A
_
9. Wall types
_
a. Frame, Wood, Adjacent
R=11.0, 249.0 W _
b. Frame, Wood, Exterior
R=11.0, 1861.0 ft2
c. Frame, Wood, Exterior
R=19.0, 317.0 ft2 _
d. N/A
e. N/A
_
10. Ceiling types
_
a. Under Attic
_
R=30.0, 3614.0 ft2
b. N/A
c. N/A
_
11. Ducts
_
a. Sup: Unc. Ret: Unc. AH: Garage
_
Sup. R=6.0, 250.0 ft
b. Sup: Unc. Ret: Con. AH: Interior
Sup. R=6.0, 150.0 ft
12. Cooling systems
a. Central Unit
b. Central Unit
c. N/A
13. Heating systems
Cap: 58.0 kBtu/hr _
SEER:13.00 _
Cap: 17.0 kBtu/hr _
SEER: 13.00
a. Electric Heat Pump ap: 56.0 kBtu/hr
HSPF:8.00 _
b. Electric Heat Pump
: 16.0 kBtu/hr _
HSPF:7.70 _
c. N/A
14. Hot water systems
a. Electric Resistance
Cap: 50.0 gallons _
b. N/A
EF: 0.95 _
c. ConvXcrt
15.
ry, Solar
heat pump)
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.17 Total as -built points: 37165 PASS
Total base points: 38966
I hereby certify that the plans pecifi tions c r d by
this calculation are in com a with t FI gy
Code.
PREPARED BY•
DATE: � 6
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER_ /AGENT:
BATE•
4--
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
MZ-C, PT,
-1.Predominant glass type.`For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5)
FORM 600A-2004R EnergyGauge@ 4.5
.4 SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt
Area X SPM X SOF = Points
.18 3614.0
24.35
15840.0
1.Single, Tint
N
2.0 7.0
144.0
24.46 0.92
3255.0
2.Single, Tint
N
2.0 6.0
69.0
24.46 0.90
1524.0
3.Single, Tint
N
17.0 6.0
16.0
24.46 0.61
239.0
4.Single, Tint
N
6.0 9.0
128.0
24.46 0.79
2465.0
5.Single, Tint
E
2.0 6.0
115.0
53.27 0.85
5236.0
6.Single, Tint
W
6.0 6.0
32.0
47.90 0.54
835.0
7.Single, Tint
W
2.0 6.0
46.0
47.90 0.85
1881.0
8.Single, Tint
S
2.0 6.0
23.0
39.84 0.80
731.0
9.Single, Tint
S
2.0 6.0
30.0
39.84 0.80
953.0
As -Built Total:
603.0
17119.0
WALL TYPES
Area X BSPM
= Points
Type
R-Value ea
X SPM =
Points
Adjacent
249.0
0.70
174.3
1. Frame, Wood, Adjacent
1
2
0.70
174.3
Exterior
2178.0
1.90
4138.2
2. Frame, Wood, Exterior
1861.
1.90
3535.9
3. Frame, Wood, Ext rior
0
317.0
1.00
317.0
Base Total:
2427.0
4312.6
As -Built Total:
2427.0
4027.2
DOOR TYPES
Area X BSPM
= Points
T r e
Area
X SPM =
Points
Adjacent
21.0
1.60
33.6
1.Ext for Insulated
48.0
4.80
230.4
Exterior
48.0
4.80
230.4
2.Adjacent Insulated
21.0
1.60
33.6
Base Total:
69.0
264.0
As -Built Total:
69.0
264.0
CEILING TYPES Area X
BSPM
= Points
Type
R-Value
Area X SPM X SCM =
Points
Under Attic
3614.0
2.13
7697.8
1. Under Attic
30.0
3614.0 2.13 X 1.00
7697.8
Base Total:
3614.0
7697.8
As -Built Total:
3614.0
7697.8
FLOOR TYPES
Area X
BSPM
= Points
Type
R-Value Area
X SPM =
Points
Slab
322.0(p)
-31.8
-10239.6
1. Slab -On -Grade Edge Insulation
0.0
322.0(p
-31.90
-10271.8
Raised
0.0
0.00
0.0
Base Total:
-10239.6
As -Built Total:
322.0
-10271.8
INFILTRATION
Area X
BSPM
= Points
Area X SPM =
Points
3614.0
14.31
51716.3
3614.0
14.31
51716.3
EnergyGauge® DCA Form 60OA-2004R EnergyGaugeO/FIaRES'2004 FLRCSB v4.5
FOAR 600A-2004R EnergyGauge® 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
Summer Base Points: 69591.1
Summer As -Built Points:
70552.6
Total Summer X System = Cooling
Total X Cap
X Duct X System X
Credit =
Cooling
Points Multiplier Points
Component Ratio
Multiplier Multiplier
Multiplier
Points
(System - Points)
(DM x DSM x AHU)
(sys 1: Central Unit 58000btuh ,SEER/EFF(13.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0(INS)
70553 0.77
(1.09 x 1.150 x 1.00) 0.260
0.902
16004.0
(sys 2: Central Unit 17000btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS)
70553 0.23
(1.08 x 1.150 x 0.90) 0.260
0.902
4190.7
69591.1 0.3250 22617.1
70552.6 1.00
1.200 0.260
0.902
19867.3
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5
FOF M 600A-2004R EnergyGauge® 4.5
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned
X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt
Area X WPM X WOF = Point
.18 3614.0
9.11
5926.0
1.Single, Tint
N
2.0 7.0
144.0 15.38 1.00
2206.0
2.Single, Tint
N
2.0 6.0
69.0 15.38 1.00
1056.0
3.Single, Tint
N
17.0 6.0
16.0 15.38 0.98
242.0
4.Single, Tint
N
6.0 9.0
128.0 15.38 0.99
1952.0
5.Single, Tint
E
2.0 6.0
115.0 13.04 1.03
1544.0
6.Single, Tint
W
6.0 6.0
32.0 13.80 1.08
478.0
7.Single, Tint
W
2.0 6.0
46.0 13.80 1.02
648.0
8.Single, Tint
S
2.0 6.0
23.0 10.88 1.12
279.0
9.Single, Tint
S
2.0 6.0
30.0 10.88 1.12
364.0
As -Built Total:
603.0
8769.0
WALL TYPES
Area X BWPM
= Points
Type
R-Value
Area X WPM =
Points
Adjacent
249.0
1.80
448.2
1. Frame, Wood, Adjacent
11.0 f.49.0 1.80
448.2
Exterior
2178.0
2.00
4356.0
2. Frame, Wood, Exterior
2.00
3722.0
3. Frame, Wood, Exterior
Q1.0
7.0 1.10
348.7
Base Total:
2427.0
4804.2
As -Built Total:
24 7.0
4518.9
DOOR TYPES
Area X BWPM
= Points
Type
L'
4
t;.
Area X WPM =
Points
Adjacent
21.0
4.00
84.0
uia
48.0 5.10
244.8
Exterior
48.0
5.10
244.8u
Jdjak
21.0 4.00
84.0
Base Total:
69.0
328.8
uilt Total:
69.0
328.8
CEILING TYPES Area X
BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
3614.0
0.64
2313.0
1. Under Attic
30.0
3614.0 0.64 X 1.00
2313.0
Base Total:
3614.0
2313.0
As -Built Total:
3614.0
2313.0
FLOOR TYPES
Area X
BWPM
= Points
Type
R-Value
Area X WPM =
Points
Slab
322.0(p)
-1.9
-611.8
1. Slab -On -Grade Edge Insulation
0.0 322.0(p 2.50
805.0
Raised
0.0
0.00
0.0
Base Total:
-611.8
As -Built Total:
322.0
805.0
INFILTRATION
Area X
BWPM
= Points
Area X WPM =
Points
3614.0
-0.28
-1011.9
3614.0 -0.28
-1011.9
EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
r
w
FORM 600A-2004R EnergyGauge@ 4.5
L ' WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
a
ADDRESS: , , , PERMIT #:
BASE
AS -BUILT
Winter Base Points:
11748.2
Winter As -Built Points:
15722.7
Total Winter X System =
Heating
Total X Cap X Duct X System X
Credit
= Heating
Points Multiplier
Points
Component Ratio Multiplier Multiplier
Multiplier
Points
(System - Points) (DM x DSM x AHU)
(sys 1: Electric Heat Pump 56000 btuh ,EFF(8.0) Ducts:Unc(S),Unc(R),Gar(AH),R6.0
15722.7 0.778 (1.078 x 1.160 x 1.00) 0.427
0.950
6197.7
(sys 2: Electric Heat Pump 16000 btuh ,EFF(7.7) Ducts:Unc(S),Con(R),Int(AH),R6.0
15722.7 0.222 (1.068 x 1.160 x 0.92) 0.443
0.950
1676.9
11748.2 0.5640
6508.5
15722.7 1.00 1.209 0.430
0.960
7768.7
EnergyGaugeTA° DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM600A-2004R EnergyGauge® 4.5
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: ... PERMIT #:
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume
Bedrooms Ratio Multiplier
4 2460.00
9840.0
50.0 0.95
4 1.00 2382.32 1.00 9529.3
As -Built Total:
9529.3
CODE
COMPLIANCE STATUS
BASE
AS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= Total
Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
22617 6509
9840
38966
19867 9529 37165
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FIaRES'2004 FLRCSB v4.5
FORM 600A-2004R EnergyGauge® 4.5
~ Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: , , , PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
from, and is sealed to the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless backed by truss or joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
to the perimeter, penetrations and seams.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
installed that is sealed at the perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion sp a comply with NFPA,
have combustion air.
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exc�ede by all sid cis.) 10
® Tov
COMPONENTS
SECTION
REQUIREME
CHECK
Water Heaters
612.1
Comply with e ' cLsin Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric r cuas must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficiency of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5