Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETAW2201 IZC YRMLWED FCC ®® COMPLIANCE PL.IANCE File Copy IC ®LINTY ST LUCIE CO'UNT'Y'�G� J,NFORMATION SHEET M�LZ Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE 'G COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING Swt APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1:2. 3 4,%Qi7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles L A, B, D 1 2A5 67 1234;567 Concrete or Clay Tile A, B, D, E Metal Roofs A, B, D 1:23;45;67 Wood Shingles and Shakes A, B, D i°2;45;67 Other As Applicable 1234;5;67 ATTACHMENTS REQUIRED As Applicable): 1. ory fisting Page 9 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. g onsi era i Only) 7. Any Required Roof Testing/Calculation Documentation Form Roof1nfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. /6 � J License # �C (3 33 o- c. O Contractors Name: q0S it EL Job Address d ROOF CATEGORY ffl oSlope 0 Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles ;Asphaltic Shingles 0 Metal Panel/Shingles ❑Wood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE_ 0 New roof 0 Repair �� 0 Maintenance M,Reroofing 0 Recovering Low Slope Roof Area (SF) 500 _ ROOF SYSTEM INFORMATION r`� �1 Steep Sloped Roof Area (SF) 2 l V c) Total (SF)W Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Pok.j Q1a1 9 U S la �_V`40G- C 0 V_ 0 Notice of Acceptance Number: Minimum Design Wind Pr,c--ares, If Applicable (Frorn RAS 127 or Calculat' ns): Zone 1:'�' Zone 2e. _ —'one 2r,.—Zone 2r:._ Cone 3E: .Zone 3r: DecicType ( S 3 Z 1 w� 'Typ&.Undeclayme i ; . Rop Slope;; Mean..RooF Height: I' �' VTYpe Cap'Sheet Roof Covering 11(owen cot, c ti Du a S h v1i f Type & Size Drip 2 Z CZC�i� Ectcm�. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used,t identify as "NA") System Manufacturer: _ I���Cj jq L1 C Product Approval No.: EL K2 S 9 tZ3y Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: - _ Zone 2: zone - Max. Design Pressure, from the specific product approval system: Aq 2 F Deck: Type: P 1i W Q oci Gauge Thickness:�'z_� Slope:% 2 Anchor/Base Sheet & No. df Ply(s): RIS4 Ojt V Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer:' IV 10 Base Insultation Size and Thickness: /U Base Insulation Fastener/Bonding Material: N Top Insulation Layer: All jq Top Insulation Size and Thickness: Top Insulatio"n�Fastener/Bonding Material: Base Sheets) & No. of Ply(s): N/ P— Base Sheet Fastener/Bonding Material: /V Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: A,/114, Top Ply: Top Ply Fastener/Bonding Material: �clyl.eyleC1 Surfacing: Fastener Spacing for Ancho /Base Sheet Attachment: Zone 1':_.._." oc @ Lap, # Rows @ "oc Zone 1:—" oc @ Lap, # Rows @ ':cid Zone 2:—" oc @ Lap, #Rows @ ".oc Zone 3:—.._." oc @ Lap, # Rows @ Number of Fasteners Per Insulation Board: / Zone 1': Zone 1: Zone 2:_ : Zon 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16..