HomeMy WebLinkAboutNOA - CONCRETE ROOF TILEMIAMI•DADE MIANII-DARE COUNTY M PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Ve ity Hurric Zone of th rida Building Code. DESCRIPTIO Saxony 900 Concrete Roof T' 11-1 LABELING: Each nit shad ear a pe ent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No.19-0814.01 and consists of pages I through 12. The submitted documentation was reviewed by Freddy Semino NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 1 of 12 ROOFING ASSEMBLY APPROVAL Category Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Saxony 900-Slate Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-5/32" batten, mortar set or adhesive set applications. Saxony 900 - Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Split Shake Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Top surface produced with 4 different configurations: 1. Complete tile brushed 2. Right half brushed (shown in drawing) 3. Left half brushed 4. No brush Saxony 900-Shake Length = 17" TAS 112 Flat profile, interlocking, high-pressure extruded Width = 13" concrete roof tile with two nail holes. For direct deck, thickness = 1-9/32" batten, mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete roof Width: varies pieces for use at hips, ridges and rakes. varying thickness NOA No.: 21-0107.02 MIAMI.DADE COUNTYM Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 2 of 12 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Descriution ICP Adhesives Polysee AH-160 Two component polyurethane foam adhesive. TILE BONDTM Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. "Tile Tite" Roof Tile Mortar Premixed, pre -bagged roof tile mortar. Touch `N Seal StormBond® 2 Two- Two component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2MANUFACTURING LOCATION 2.2.1 Lake Wales, FL 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier The Center for 94-084 Applied Engineering, Inc. Redland Technologies 94-060A 25-7183-6 25-7183-5 25-7214-1 25-7214-5 Project No. 307025 Test #MDC-77 7161-03 Appendix II & III Letter Dated Aug. 1, 1994 P0631-01 P0402 Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. Bermuda Roof Co. Inc. DAP Foam, Inc. Test Name/Report Date Static Uplift Testing May 1994 TAS 101 (Mortar Set) Static Uplift Testing March, 1994 TAS 101 (Adhesive Set) Static Uplift Testing TAS 102 Feb. 1995 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing TAS 102 Feb. 1995 (2 Quik-Drive Screws, Battens) Static Uplift Testing TAS 102 March, 1995 (1 Quik-Drive Screw, Direct Deck) Static Uplift Testing TAS 102 March, 1995 (1 Quik-Drive Screw, Battens) Wind Driven Rain Oct. 1994 TAS 100 Wind Tunnel Testing Dec. 1991 TAS 108 (Nail -On) Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails NOA No.: 21-0107.02 MIAMI•I ADE COUNTY Expiration Date: 04/26/22 + Approval Date: 03/04/21 Page 3 of 12 Atlanta Testing & R1.894/R2.894/R3.894 Physical Properties Aug. 1994 Engineering, Inc. TAS 112 Celotex Corporation 520109-1 Static Uplift Testing Dec. 1998 Testing Service 520111-4 TAS 101 520191-1 Static Uplift Testing March 1999 TAS 101 Walker Engineering, Evaluation Calculations 25-7094 February 1996 Inc. Evaluation Calculations 25-7496 April 1996 Evaluation Calculations 25-7584/25-7804b-8/25-7804-4 & 5 December 1996 25-7848-6 Evaluation Calculations 25-7183 March 1995 Evaluation Calculations Aerodynamic Multipliers 09/01/16 Calculations Two Patty Adhesive Set System April 1999 Evaluation Calculations Restoring Moments Due to Gravity 09/01/16 American Test Lab of RT0617.04-16 TAS 112 06/29/16 South Florida PRI Construction COPO-002-02-12 TAS 101 10/12/2016 Material COPO-002-02-06 TAS 101 10/12/2016 COPO-002-02-05 TAS 101 10/12/2016 BORR-022-02-01 TAS 101 02/25/2019 BORR-022-02-02 TAS 101 02/25/2019 BORR-022-02-03 TAS 101 02/25/2019 BORR-022-02-04 TAS 101 02/28/2019 NEMO ETC, LLC 4c-DPBS-20-LSOTM-0l.C.R1 TAS 101 12/17/20 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Mechanically attached tiles minimum slope 4/12. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 4 of 12 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) ile Profile Weight-W (lbf) Length-1(ft) Width-w (ft) x y 00 SI e, a e S lit Shake 10.9 1.417 1. 18 Table 2: Aerodynamic Multipliers - A. (ft) Tile (ft3) (ft3) Profile Batten Application Direct Deck Application Saxony 900 0.291 0.315 Slate, Shake & Split Shake Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile 2"•12" 3":12" 4":12" 5":12" 6"•12" 7":12" or Profile greater Saxony 900 Direct Deck Direct Deck Battens Direct Battens Direct Battens Direct Battens I Direct Slate &, Shake & Deck 1 Deck Deck Deck _Slit Shake 7.70 7.62 6.61 7.50 6.48 7.34 6.31 7.16 6.13 6.95 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Saxony 900 2-10d Ring Shank Nails 30.9 38.1 17.2 Slate, Shake & 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 Split Shake 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 .#8 Screw 30.8 30.8 18.2 2 .#8 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Cli 31.9 31.9 32.2 NOA No.: 21-0107.02 MIAMI.DADE COUNTY Expiration Date: 04/26/22 �lrjums'rjg Approval Date: 03/04/21 Page 5 of 12 G Table 5: Attachment Resistance Expressed as a Moment Mf (ft.-lbf) for Two Paddy Adhesive' Set Systems Tile Tile Application Minimum Attachment Profile Resistance Saxony 900 DuPont de Nemours, Inc. Slate, Shake $ Split Shake TILE BONDTm Roof Tile Adhesive 632 TILE BONDTm Roof Tile Adhesive 655 ICP Adhesives and Sealants, Inc. 31.33 ICP Adhesives Pol set® AH-160 DAP Foam, Inc.Touch 'N Seal 594 StormBond ®2 Two -Component Polyurethane Roof Tile Adhesive 1 See foam adhesive manufacturer's component approval for installation requirements. 2 Dupont de Nemours, Inc TILE BONDTm Roof Tile Adhesive one -component foam minimum weight per paddy 8 grams. 3. ICP Adhesives and Sealants Inc, ICP Adhesives Polyset® AH-160 two -component foam, minimum weight per paddy 8 grams. 4. DAP Foam, Inc. Touch 'N Seal StormBond® 2 Two -Component Polyurethane Roof Tile Adhesive two -component foam minimum weight per paddy 8 grams. 5. Dupont de Nemours, Inc. TILE BONDT1 Roof Tile Adhesive one -component foam; Average weight per patty 16 rams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance CSaxonZy900 Split Shake ICP Adhesives and Sealants, Inc. Polyset® AH-160 1196 1157 838 609 DAP Foam, Inc.Touch 'N Seal Storm Bond® 2 Two -Component Polyurethane Roof Tile Adhesive 9310 6211 5 See Table 5 6 Large paddy placement of 45 grams of ICP Adhesives and Sealants, Inc. Pol set® AH-160 two -component foam. 7 Large paddy placement of 34 grams of ICP Adhesives and Sealants, Inc. Pol set® AH-160 two -component foam. 8 Medium add lacement of 24 grams of ICP Adhesives and Sealants, Inc. Pol set® AH-160 two -component foam. 9 Medium paddy placement of 18 grams of ICP Adhesives and Sealants, Inc. Pol set® AH-160 two -component foam. 10 Large paddy DAP Foam, Inc Touch 'N Seal StormBond® 2 Two -Component Polyurethane Roof Tile Adhesive two - component foam minimum weight per paddy 45 grams. 11 Medium paddy DAP Foam, Inc.Touch 'N Seal StormBond° 2 Two -Component Polyurethane Roof Tile Adhesive two - component foam minimum weight per paddy 24 grams. NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 6 of 12 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft: Ibf) for Mortar Set Systems Tile Tile Minimum Attachment Profile Application Resistance Saxony 900 Mortar Set12 43.9 Slate, Shake & Split Shake 12 Bermuda Roof Co. Inc. Tile -rite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". O LABEL FOR BORAL SAXONY 900 TILES (LAKE WALES FL PLANT) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 7 of 12 PROFILE DRAWINGS NAIL HOLES UNDERLOCK SAXONY 900 - SLATE MIAMI-DADE COUN ... 9 - 5/32" (Slate) COVERLOCK NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 8 of 12 Note: 5. 6. 7. 8. PROFILE DRAWINGS Available Top Surface Finishes Complete tile brushed Right half brushed (shown in drawing) Left half brushed No brush SAXONY 900 - SPLIT SHAKE 1-9/32" (Shake) NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 9 of 12 PROFILE DRAWINGS NAIL HOLES u SAXONY 900- SHADE MIAMI*DADE COUNTY 1-9/32"(Shake) NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 10 of 12 set Intedepemdent: Two (2) beads/paddys; Attahment, minimum 1-in, x I -in. x I"mum contad area of 16 # in2 each SET IA Paddy Minimum Attachment Type Placement in. Tile Contact Characteristic Resistance Cxpresse4 --I-Area, ins per Tile Resistance Force, lbf as Moment, ft-lbf Attachment: Two (2) beads/paddys, Interdependent I minimum I -in. x 1-in, x 8-in. 32 57 63 IAdherve Rates. a gram/paddy I I I NOA No.: 21-0107.02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 11 of 12 Tile Allaterial Paddy Minimum Profile Prodact Type pl. F cement Min Tile Contact Characteristic Area, in2per Tile Resistance Force, Attachment: Two (2) beads/paddys, Independent minimum 2-in, x 2-in, x 4-in., starting Y' back from head of underlying tile Adhesive Rates. 16gram/paddy APPROVED 16 END OF THIS ACCEPTANCE I Attachment Resistance Expressed ,bf as a Moment, ft4lif 65 NOA No.: 21-0107-02 Expiration Date: 04/26/22 Approval Date: 03/04/21 Page 12 of 12