HomeMy WebLinkAboutcabanna door installation page 2ALUMINUM SCREEN
ENCLOSURE POST
BY OTHERS.
�O SELF TAPPING
SH METAL SCREW
INTO POST SEE ELEVATION
FOR ANCHOR SPACING.
3/16"
TAPCON W/
1 1 /4" MIN
EMBEDMENT
INTO
CONCRETE
;AN I�
4CE
EXTERIOR
NOMINAL
DOOR
HEIGHT
10 SELF TAPPING--3i.5 �--i
MEET METAL SCREW
MAC. 6 FROM CORNERS AND
44 O.C. MAX. TYP.
q� 14.75' 14,75.4°,
04, r�
3�ETi0 SELF TAPPING
PER EACH HINGEREW
10 SELF TAPPING
SHE
,Xr METAL SCREW
3.5 FROM CORNERS AND
15.25" O.C. MAX. TYP.
DOOR INTERIOR
ALUMINUM SCREEN
ENCLOSURE POST -
BY OTHERS.
SELF TAPP
DOOR SHEVOMETAL SCREW
INTO POST SEE ELEVATION
DP = ±55 PSF 11/4*
SEE NOTE 10 SHIM
OP = f 14.4 PSF
SEE NOTE 11 a
f 111 !f�l4 �f �rd1// P I
1�I�11y1P11 �`llri�Q f �.
TYP. HEAD & SILL SECTION
(OUTSWING)
�d10 SELF TAPPING
SHEET METAL SCREW
5.75 FROM CORNERS AND
17.125 O.C. MAX. TYP,
OPTIONAL ACRYLIC GLAZING NOTE:
EXTERI
t..
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO
COMPLY WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017).
2) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD
BEARING SHIM. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4", SHIM
WHERE SPACE Of 1/16" OR GREATER OCCURS.
3) MATERIAL: ALUMINUM ALLOY 6063-T5.
4) 1/8" TEMPERED GLAZING MEETS THE REQUIREMENTS Cl;' ASTM E
1300-04.
5) RESPONSIBILITY FOR SELECTION OF WINDOW PRODUCTS TO MEET
ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR
OTHER SAFETY REQUIREMENTS REST SOLELY WITH THE ARCHITECT,
BUILDING OWNER OR CONTRACTOR.
6) POSTS BY OTHERS - THE POSTS SUPPLIED BY OTHERS SMALL:
A) PROVIDE STRUCTURAL STRENGTH TO CARRY IMPOSED LOADS.
B) FIRMLY ANCHOR ALL FASTENERS TO CARRY STRUCTURAL LOADS.
7) USE FASTENER SCHEDULE ON ELEVATION VIEW.
8) USE LATEX CAULK OR EUIVIA€.ENT FOR PERIMETER SEAL AROUND
BEHIND DOOR FLANGE
9) ALL INSTALLATION ANCHORS MUST BE MADE OF CORROSION RESISTANT
MATERIAL OR COATING
10) PRODUCT AND INSTALLATION CONTAINED HEREIN COMPLIES CAPACITY
OF POS. AND NEG. 55.0 PSF.
11) OPTIONAL GLAZING IS 1/8" ACRYLIC. WHEN PRODUCT IS USED WITH
THIS OP11ON THE MAXIMUM DESIGN PRESSURE RATING 1S LIMITED TO
12) SECTION 1622.1 SCREEN ENCLOSURES ALLOW THE USE OF WNYL AND
ACRYLIC REMOVABLE PANELS. A DECAL STATING THE THE GLAZED
PANEL MUST BE REMOVED 1F THE WIND SPEED EXCEEDS 75 MPH.
THE DECAL SHALL BE PLACED SO THAT IT IS VISIBLE WHEN THE
PANEL CIS INSTALLED.
13) DESIGN PRESSURES, ANCHOR SPACING AND LOCATIONS DERIVED FROM
TESTED UNIT, TEST REPORT CTLA-1297W, NAME$ N1005907A.
DOOR
I10 SELF TAPPING —�
HEET METAL SCREW
INTO POST SEE ELEVATION 1/4" MAX--
FOR ANCHOR SPACING, I�
NOMINAL I
SHIM
WIDTH WINDOW CRAFTSMEN, INC.
TYP, JAMB SECTION 6031 CLARK CENTER AVE.
(OUTSWING) SARASOTA, FLORIDA 34238
WINDOW VENTS SHALL DE REMOVED WHEN 3 SECOND GUSTS, V36=75 MPH AS PER
SECTON 1622.2 1 OF THE FLORDA BUILDING CODE. REMOVABLE PANELS SHALL
BE INDENTIFIED AS REMOVABLE BY A DECAL. THE IDENTIFICATION DECAL SHALL
ESSENTIALLY STATE " Removable panel shaft IJe removed when wind speed$,
exceed 75 mph (34mla)." DECALS SHALL BE PLACED SUCH THATTHE DECAL IS
VISIBLE WHEN THE PANEL IS INSTALLED. ,,,..,, —1 , „
Digitally signed by
-Mark Smith
Date:2019.09.10
`7Y0 6TAMOR
ALUMINUM PRIME ENTRY DOOR
INSTALLATION DETAILS
(ENGINEER: MARK A. SMITHIUrr WN Uf-MAS PATE: 6/29/15 I
REG. NO.: 55511 1REVG
N.T.S.