Loading...
HomeMy WebLinkAboutcabanna door installation page 2ALUMINUM SCREEN ENCLOSURE POST BY OTHERS. �O SELF TAPPING SH METAL SCREW INTO POST SEE ELEVATION FOR ANCHOR SPACING. 3/16" TAPCON W/ 1 1 /4" MIN EMBEDMENT INTO CONCRETE ;AN I� 4CE EXTERIOR NOMINAL DOOR HEIGHT 10 SELF TAPPING--3i.5 �--i MEET METAL SCREW MAC. 6 FROM CORNERS AND 44 O.C. MAX. TYP. q� 14.75' 14,75.4°, 04, r� 3�ETi0 SELF TAPPING PER EACH HINGEREW 10 SELF TAPPING SHE ,Xr METAL SCREW 3.5 FROM CORNERS AND 15.25" O.C. MAX. TYP. DOOR INTERIOR ALUMINUM SCREEN ENCLOSURE POST - BY OTHERS. SELF TAPP DOOR SHEVOMETAL SCREW INTO POST SEE ELEVATION DP = ±55 PSF 11/4* SEE NOTE 10 SHIM OP = f 14.4 PSF SEE NOTE 11 a f 111 !f�l4 �f �rd1// P I 1�I�11y1P11 �`llri�Q f �. TYP. HEAD & SILL SECTION (OUTSWING) �d10 SELF TAPPING SHEET METAL SCREW 5.75 FROM CORNERS AND 17.125 O.C. MAX. TYP, OPTIONAL ACRYLIC GLAZING NOTE: EXTERI t.. 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE FLORIDA BUILDING CODE 6TH EDITION (2017). 2) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4", SHIM WHERE SPACE Of 1/16" OR GREATER OCCURS. 3) MATERIAL: ALUMINUM ALLOY 6063-T5. 4) 1/8" TEMPERED GLAZING MEETS THE REQUIREMENTS Cl;' ASTM E 1300-04. 5) RESPONSIBILITY FOR SELECTION OF WINDOW PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFETY REQUIREMENTS REST SOLELY WITH THE ARCHITECT, BUILDING OWNER OR CONTRACTOR. 6) POSTS BY OTHERS - THE POSTS SUPPLIED BY OTHERS SMALL: A) PROVIDE STRUCTURAL STRENGTH TO CARRY IMPOSED LOADS. B) FIRMLY ANCHOR ALL FASTENERS TO CARRY STRUCTURAL LOADS. 7) USE FASTENER SCHEDULE ON ELEVATION VIEW. 8) USE LATEX CAULK OR EUIVIA€.ENT FOR PERIMETER SEAL AROUND BEHIND DOOR FLANGE 9) ALL INSTALLATION ANCHORS MUST BE MADE OF CORROSION RESISTANT MATERIAL OR COATING 10) PRODUCT AND INSTALLATION CONTAINED HEREIN COMPLIES CAPACITY OF POS. AND NEG. 55.0 PSF. 11) OPTIONAL GLAZING IS 1/8" ACRYLIC. WHEN PRODUCT IS USED WITH THIS OP11ON THE MAXIMUM DESIGN PRESSURE RATING 1S LIMITED TO 12) SECTION 1622.1 SCREEN ENCLOSURES ALLOW THE USE OF WNYL AND ACRYLIC REMOVABLE PANELS. A DECAL STATING THE THE GLAZED PANEL MUST BE REMOVED 1F THE WIND SPEED EXCEEDS 75 MPH. THE DECAL SHALL BE PLACED SO THAT IT IS VISIBLE WHEN THE PANEL CIS INSTALLED. 13) DESIGN PRESSURES, ANCHOR SPACING AND LOCATIONS DERIVED FROM TESTED UNIT, TEST REPORT CTLA-1297W, NAME$ N1005907A. DOOR I10 SELF TAPPING —� HEET METAL SCREW INTO POST SEE ELEVATION 1/4" MAX-- FOR ANCHOR SPACING, I� NOMINAL I SHIM WIDTH WINDOW CRAFTSMEN, INC. TYP, JAMB SECTION 6031 CLARK CENTER AVE. (OUTSWING) SARASOTA, FLORIDA 34238 WINDOW VENTS SHALL DE REMOVED WHEN 3 SECOND GUSTS, V36=75 MPH AS PER SECTON 1622.2 1 OF THE FLORDA BUILDING CODE. REMOVABLE PANELS SHALL BE INDENTIFIED AS REMOVABLE BY A DECAL. THE IDENTIFICATION DECAL SHALL ESSENTIALLY STATE " Removable panel shaft IJe removed when wind speed$, exceed 75 mph (34mla)." DECALS SHALL BE PLACED SUCH THATTHE DECAL IS VISIBLE WHEN THE PANEL IS INSTALLED. ,,,..,, —1 , „ Digitally signed by -Mark Smith Date:2019.09.10 `7Y0 6TAMOR ALUMINUM PRIME ENTRY DOOR INSTALLATION DETAILS (ENGINEER: MARK A. SMITHIUrr WN Uf-MAS PATE: 6/29/15 I REG. NO.: 55511 1REVG N.T.S.