HomeMy WebLinkAboutEnergy Efficiency CodeFORM 60OA-2004R EnergyGauge® 4.5
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
Residential Whole Building Performance Method A
Project Name: LOT 33 1 Builder:
Address: LOT 33, WATERSONG WAY Permitting Office:
City, State: ST. LUCIE COUNTY, FL Permit Number:
Owner: Jurisdiction Number:
Climate Zone: Central
1. New construction or existing
New _
2. Single family or multi -family
Single family _
3. Number of units, if multi -family
1
4. Number of Bedrooms
4 _
5. Is this a worst case?
Yes _
6. Conditioned floor area (ft2)
3896 ft2
7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default)
a. U-factor:
Description Area
(or Single or Double DEFAULT)
7a(Sngle Default) 613.0 ft2 _
b. SHGC:
(or Clear or Tint DEFAULT)
7b. (Tint) 613.0 ft2 1
8. Floor types
a. Raised Wood
R=11.0, 198.0 ft2
b. Slab -On -Grade Edge Insulation, 0
R=0.0, 196.0 ftz `�.
c. 1 Others
177.0 ft2 _
9. Wall types
a. Concrete, Int Insul, Exterior
R=2431.0, 4.1 ft2
b. Frame, Wood, Adjacent
R=312.0, 11.0 ft2
c. N/A
_
d. N/A
_
e. N/A
_
10. Ceiling types
a. Under Attic
R=30.0, 1743.0 ft2
b. Under Attic
R=30.0, 1827.0 ft2
c. N/A
_
11. Ducts
a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 136.0 ft
b. Sup: Unc. Ret: Unc. AH(Sealed):Garage Sup. R=6.0, 135.0 ft _
12. Cooling systems
a. Central Unit
b. Central Unit
c. N/A
13. Heating syst0
a. Electric He,q Pump
b. °ic Heat Pump
14. Hot water systems
a. Electric Resistance
b. N/A
c. Conservation credits
(HR-Heat recovery, Solar
DHP-Dedicated heat pump)
15. HVAC credits
(CF-Ceiling fan, CV -Cross ventilation,
HF-Whole house fan,
PT -Programmable Thermostat,
MZ-C-Multizone cooling,
MZ-H-Multizone heating)
Glass/Floor Area: 0.16 Total as -built points: 37354 PASS
Total -base points: 38729
I hereby certify that the plans and specifications coved by J
this calculation are in compliance with the Florida Ener
Code. SDI "aH P_ -83CX4
PREPARED BY: 1ila C `ce_
DATE: 'CY2
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4.
EnergyGauge® (Version: FLRCSB v4.5)
Cap: 58.5 kBtu/hr _
SEER:14.00 _
Cap: 41.0 kBtu/hr _
SEER: 14.00
Cap: 30.2 kBtu/hr _
HSPF:8.60
Cap: 25.2 kBtu/hr
HSPF: 8.10 _
Cap: 80.0 gallons _
EF: 0.97
PT, _
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE SCORE* = 86.7
The higher the score, the more efficient the home.
, LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL,
1. New construction or existing New _ 12. Cooling systems
2. Single family or multi -family Single family _ a. Central Unit Cap: 58.5 kBtu/hr _
3. Number of units, if multi -family 1 _ SEER: 14.00 _
4. Number of Bedrooms 4 _ b. Central Unit Cap: 41.0 kBtu/hr
5. Is this a worst case? Yes _ SEER: 14.00 _
6. Conditioned floor area (ft2) 3896 ft2 _ c. N/A _
7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default)
a. U-factor: Description Area 13. Heat' syste
(or Single or Double DEFAULT) 7a(Sngle Default) 613.0 ft' _ El 'c eat p Cap: 30.2 kBtu/hr _
b. SHGC: � HSPF: 8.60
(or Clear or Tint DEFAULT) 7b. (Tint) 613.0 ft2 I ct ( seat Pump Cap: 25.2 kBtu/hr
8. Floor types HSPF: 8.10
a. Raised Wood R=11.0, 198.0 ft2 _ c. N/A
b. Slab -On -Grade Edge Insulation, 0 R=0.0, 196.0 ft2
c. 1 Others 177.0 ft2 _ 14. Hot water systems
9. Wall types a. Electric Resistance Cap: 80.0 gallons
a. Concrete, Int Insul, Exterior R=2431.0, 4.1 ft2 _ EF: 0.97 _
b. Frame, Wood, Adjacent R=312.0, 11.0 ft2 _ b. N/A
c. N/A
d. N/A _ c. Conservation credits _
e. N/A _ (HR-Heat recovery, Solar
10. Ceiling types DHP-Dedicated heat pump)
a. Under Attic R=30.0, 1743.0 ft2 _ 15. HVAC credits PT,
b. Under Attic R=30.0, 1827.0 ft2 _ (CF-Ceiling fan, CV -Cross ventilation,
c. N/A _ HF-Whole house fan,
11. Ducts PT -Programmable Thermostat,
a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 136.0 ft _ MZ-C-Multizone cooling,
b. Sup: Unc. Ret: Unc. AH(Sealed):Garage Sup. R=6.0, 135.0 ft _ MZ-H-Multizone heating)
I certify that this home has complied with the Florida Energy Efficiency Code For Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
ZHE ST,9��0�
*NOTE: The home's estimated energy performance score is only available through the FLARES computer program.
This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation),
your home may qualijy for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating.
Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for
information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building
Construction, contact the Department of Community Affairs at 8501487-1824.
1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on ages 2&4.
$nergyGauge® (Version: FLRCS�B v4.5)
FORM 60OA-2004R EnergyGauge@ 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BSPM =
Points
Overhang
Floor Area
Type/SC
Ornt Len Hgt
Area X. SPM X
SOF = Points
.18 3896.0
24.35
17076.0
1.Single, Tint
W 2.0 15.0
20.0
47.90
0.99
945.0
2.Single, Tint
E 2.0 15.0
60.0
53.27
0.99
3153.0
3.Singie, Tint
S 6.0 14.0
78.0
9.84
0.73
2280.0
4.Single, Tint
W 2.0 15.0
80. •
7.90
0.99
3781.0
5.Single, Tint
E 2.0 15.0
0.
3.27
0.99
3678.0
6.Single, Tint
E 2.0 1 .0
Z .
.27
0.99
1576.0
7.Single, Tint
N1 0
2Q�0
24.46
0.99
483.0
8.Single, Tint
N . 2.0 1' -
Y
36.0
24.46
0.98
866.0
9.Single, Tint
E -. ,0 19.0
2.0
53.27
0.99
105.0
10.Single, in
S 6.0 2.0
48.0
39.84
0.48
908.0
11.Single,1 t �E
2.0 5.0
40.0
53.27
0.81
1716.0
12.Single, Ti
S 2.0 6.0
20.0
39.84
0.80
635.0
13.Single, Tin
W 2.0 6.0
8.0
47.90
0.85
327.0
14.Single, Tint
N 2.0 5.0
40.0
24.46
0.88
856.0
15.Single, Tint
N 2.0 4.0
24.0
24.46
0.84
491.0
16.Single, Tint
W 2.0 3.0
21.0
47.90
0.65
654.0
17.Single, Tint
W 2.0 6.0
16.0
47.90
0.85
654.0
As -Built Total:
613.0
23108.0
WALL TYPES
Area X
BSPM
= Points
Type
R-Value
Area
X SPM
=
Points
Adjacent
11.0
0.70
7.7
1. Concrete, Int Insul, Exterior
2431.0
4.1
0.10
0.4
Exterior
4.1
1.90
7.8
2. Frame, Wood, Adjacent
312.0
11.0
0.20
2.2
Base Total:
15.1
15.5
As -Built Total:
15.1
2.6
DOOR TYPES
Area X
BSPM
= Points
Type
Area
X SPM
=
Points
Adjacent
0.0
0.00
0.0
1.Exterior Insulated
216.0
4.80
1036.8
Exterior
344.0
4.80
1651.2
2.Exterior Insulated
128.0
4.80
614.4
Base Total:
344.0
1651.2
As -Built Total:
344.0
1651.2
CEILING TYPES
Area X
BSPM
= Points
Type
R-Value Area X SPM X SCM =
Points
Under Attic
3293.0
2.13
7014.1
1. Under Attic
30.0
1743.0 2.13 X 1.00
3712.6
2. Under Attic
30.0
1827.0 2.13 X 1.00
3891.5
Base Total:
3293.0
7014.1 1
As -Built Total:
3570.0
7604.1
EnergyGauge® DCA Form 60OA-2004R EnergyGauge@/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGauge® 4.5
SUMMER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #:
BASE
AS -BUILT
FLOOR TYPES
Area X
BSPM = Points
Type R-Value Area
X SPM
= Points
Slab 196.0(p)
-31.8-6232.8
1. Slab -On -Grade Edge Insulation 0.0 196.0(p
-31.90
-6252.4
Raised-
375.0
-3.43-1286.3
2. Raised Wood, Adjacent 11.0 198.0
1.80
356.4
3. Raised Wood, Adjacent 11.0 177.0
1.80
318.6
R
Base Total:
-7519.0
As -Built Total: ,0
-6577.4
INFILTRATION
Area XBSPM
=Points
TArea X SPM
= Points
3896.0
14.31 55751.8
3896.0
14.31
55751.8
Summer Base Points: 73989.6
Sum l,*�
82640.3Bu
Total Summer X
System
= Cooling
Tota : p X Duct X System X
Credit =
Cooling
Points
Multiplier
Points
Compon6_h, Ratio Multiplier Multiplier
Multiplier
Points
(System - Points) (DM x DSM x AHU)
(sys 1: Central Unit 50500btuh ,SEER/EFF(14.0) Ducts: Unc(S), Unc(R), Int(AH), R6.0(INS)
82540 0.55 (1.09 x 1.150 x 0.90) 0.244
0.950
11859.2
(sys 2: Central Unit 41000btuh ,SEERIEFF(14.0) Ducts: Unc(S), Unc(R),Gar(AH), R6.0(INS)
82540 0.45 (1.09 x 1.150 x 0.95) 0.244
0.950
10163.2
73989.5
0.3250
24046.E
82640.3 1.00 1.156 0.244
0.950
22082.2
EnergyGaugeTTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGauge® 4.5
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT#:
BASE
AS -BUILT
GLASS TYPES
.18 X Conditioned X BWPM =
Points
Overhang
Floor Area
Type/SC
Ornt
Len Hgt
Area X WPM X WOF = Point
.18 3896.0 9.11
6389.0
1.Single, Tint
W
2.0 15.0
20.0
13.80
1.00
275.0
2.Single, Tint
E
2.0 15.0
60.0
13.04
1.01
786.0
3.Single, Tint
S
6.0 14.0
78!
10.88
1.22
1032.0
4.Single, Tint
W
2.0 15.0 .•
13.80
1.00
1103.0
5.Single, Tint
E
2.0 0
70.0
13.04
1.01
917.0
6.Single, Tint
E
2 15A,
30.0
13.04
1.01
393.0
7.Single, Tint
Y
2. 15
'
20.0
15.38
1.00
307.0
8.Single, Tint
N
2;0 -1`.0
36.0
15.38
1.00
552.0
9.Single, Tint
2'.0 19.0
2.0
13.04
1.00
26.0
10.Sing�le, i`
S
6.0 2.0
48.0
10.88
2.29
1196.0
11.Sing' a Tin
E
2.0 5.0
40.0
13.04
1.04
543.0
12.Singl nt '-;
S
2.0 6.0
20.0
10.88
1.12
243.0
13.Single, : nt
W
2.0 6.0
8.0
13.80
1.02
112.0
14.Single, Tint
N
2.0 5.0
40.0
15.38
0.99
612.0
15.Single, Tint
N
2.0 4.0
24.0
15.38
0.99
366.0
16.Single, Tint
W
2.0 3.0
21.0
13.80
1.06
307.0
17.Single, Tint
W
2.0 6.0
16.0
13.80
1.02
225.0
As -Built Total:
613.0
8995.0
WALL TYPES
Area X BWPM
= Points
Type
R-Value
Area X WPM
=
Points
Adjacent
11.0 1.80
19.8
1. Concrete, Int Insul, Exterior
2431.0
4.1
0.50
2.0
Exterior
4.1 2.00
8.2
2. Frame, Wood, Adjacent
312.0
11.0
0.70
7.7
Base Total:
15.1
28.0
As -Built Total:
15.1
9.8
DOOR TYPES
Area X BWPM
= Points
Type
Area
X WPM
=
Points
Adjacent
0.0 0.00
0.0
1.Exterior Insulated
216.0
5.10
1101.6
Exterior
344.0 5.10
1754.4
2. Exterior Insulated
128.0
5.10
652.8
Base Total:
344.0
1754.4
As -Built Total:
344.0
1754.4
CEILING TYPES Area X BWPM
= Points
Type
R-Value Area X WPM X WCM =
Points
Under Attic
3293.0 0.64
2107.5
1. Under Attic
30.0
1743.0
0.64 X 1.00
1115.5
2. Under Attic
30.0
1827.0
0.64 X 1.00
1169.3
Base Total:
3293.0
2107.5
As -Built Total:
3570.0
2284.8
EnergyGauge® DCA Form 60OA-2004R EnergyGauge@)/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R EnergyGauge@ 4.5
WINTER CALCULATIONS
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #:
BASE
AS -BUILT
FLOOR TYPES
Area X BWPM = Points
Type R-Value Area X WPM
= Points
Slab
196.0(p)
-1.9 -372.4
1. Slab -On -Grade Edge Insulation 0.0 196.0(p 2.50
490.0
Raised
375.0
-0.20 -75.0
2. Raised Wood, Adjacent 11.0 198.0 1.80
356.4
3. Raised Wood, Adjacent 11.0 177.0 1.80
318.6
Base Total:
-447.4
As -Built Total: ems .0
1165.0
INFILTRATION
Area X BWPM = Points
Area X WPM
= Points
3896.0
-0.28-1090.9
V 3896.0 -0.28
-1090.9
Winter Base Points:
8740.E
Winte Na t"'fy oints:
Cr'
13118.1
Total Winter X
System
= Heating
Total k 4Cap X Duct X System X Credit
= Heating
Points
Multiplier
Points
Component Ratio Multiplier Multiplier Multiplier
Points
(System - Points) (DM x DSM x AHU)
(sys 1: Electric Heat Pump 30200 btuh ,EFF(8.6) Ducts: Unc(S), Unc(R), Int(AH), R6.0
13118.1 0.545 (1.078 x 1.160 x 0.92) 0.397 0.950
3101.7
(sys 2: Electric Heat Pump 25200 btuh ,EFF(8.1) Ducts: Unc(S),Unc(R),Gar(AH),R6.0
13118.1 0.455 (1.078 x 1.160 x 0.95) 0.421 0.950
2837.5
8740.6
0.5540
4842.3
13118.1 1.00 1.169 0.408 0.950
6939.3
EnergyGaugelm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R
EnergyGauge® 4.5
WATER HEATING & CODE COMPLIANCE STATUS
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #:
BASE
AS -BUILT
WATER HEATING
Number of X Multiplier
= Total
Tank EF
Number of X Tank X Multiplier X Credit = Total
Bedrooms
Volume
Bedrooms Ratio Multiplier
4 2460.00
9840.0
60.0 0.97
4 1.00 2333.20 1.00 9332.8
As -Built Total:
9332.8
.c?.3Yzcr�.
CODE
COMPLIA! CE T l US
BASE'
Ne A
oAS -BUILT
Cooling + Heating +
Points Points
Hot Water
Points
= T&al
Points
Cooling + Heating + Hot Water = Total
Points Points Points Points
24047 4842
9840
38729
r 22082 5939 9333 37364
PASS
o
EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5
FORM 60OA-2004R
EnergyGauge@ 4.5
Code Compliance Checklist
Residential Whole Building Performance Method A - Details
ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #:
6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
606.1.ABC.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterier & Adjacent Walls
606.1.ABC.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors & frames,.surrounding wall;
foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
penetrations; between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier'sbarderis installed that extends
from and is sealed to, the foundation to the top plate.
Floors
606.1.ABC.1.2.2
Penetrations/openings >1/8" sealed unless bac us r.' i t members.
EXCEPTION: Frame floors where a contirtuo infilt i � arrier is installed that is sealed
to the perimeter, penetrations ands s.
Ceilings
606.1.ABC.1.2.3
Between walls & ceilings`-genetratio of ceilin ' plane of top floor; around shafts, chases,
' sous
soffits, chimne sa net ed to cont iri air barrier; gaps in gyp board & top plate;
attic acres . C I N r a ceilings where a continuous infiltration barrier is
installed the i ea l"d tf t a perimeter, at penetrations and seams.
Recessed Lighting Fixtures
606.1.ABC.1.2.4
Type IC rated lth no penetrations, sealed; or Type IC or non -IC rated, -installed inside a
sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from
conditioned space, tested.
Multi -story Houses
606.1.ABC.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
606.1.ABC.1.3
Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
have combustion air. .
6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
612.1
Comply with -efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir
breaker electric or cutoff as must be provided. External or built-in heat trap required.
Swimming Pools & Spas
612.1
Spas & heated pools must have covers (except solar heated). Non-commercial pools
must have a pump timer. Gas spa & pool heaters must have a minimum thermal
efficient of 78%.
Shower heads
612.1
Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
Air Distribution Systems
610.1
All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
attached, sealed, insulated, and installed, in accordance with the criteria of Section 610.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
607.1
Separate readily accessible manual or automatic thermostat for each system.
Insulation
604.1, 602.1
Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides.
Common ceiling & floors R-11.
F1