Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 60OA-2004R EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: LOT 33 1 Builder: Address: LOT 33, WATERSONG WAY Permitting Office: City, State: ST. LUCIE COUNTY, FL Permit Number: Owner: Jurisdiction Number: Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Single family _ 3. Number of units, if multi -family 1 4. Number of Bedrooms 4 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft2) 3896 ft2 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area (or Single or Double DEFAULT) 7a(Sngle Default) 613.0 ft2 _ b. SHGC: (or Clear or Tint DEFAULT) 7b. (Tint) 613.0 ft2 1 8. Floor types a. Raised Wood R=11.0, 198.0 ft2 b. Slab -On -Grade Edge Insulation, 0 R=0.0, 196.0 ftz `�. c. 1 Others 177.0 ft2 _ 9. Wall types a. Concrete, Int Insul, Exterior R=2431.0, 4.1 ft2 b. Frame, Wood, Adjacent R=312.0, 11.0 ft2 c. N/A _ d. N/A _ e. N/A _ 10. Ceiling types a. Under Attic R=30.0, 1743.0 ft2 b. Under Attic R=30.0, 1827.0 ft2 c. N/A _ 11. Ducts a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 136.0 ft b. Sup: Unc. Ret: Unc. AH(Sealed):Garage Sup. R=6.0, 135.0 ft _ 12. Cooling systems a. Central Unit b. Central Unit c. N/A 13. Heating syst0 a. Electric He,q Pump b. °ic Heat Pump 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.16 Total as -built points: 37354 PASS Total -base points: 38729 I hereby certify that the plans and specifications coved by J this calculation are in compliance with the Florida Ener Code. SDI "aH P_ -83CX4 PREPARED BY: 1ila C `ce_ DATE: 'CY2 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: 1 Predominant glass type. For actual glass type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.5) Cap: 58.5 kBtu/hr _ SEER:14.00 _ Cap: 41.0 kBtu/hr _ SEER: 14.00 Cap: 30.2 kBtu/hr _ HSPF:8.60 Cap: 25.2 kBtu/hr HSPF: 8.10 _ Cap: 80.0 gallons _ EF: 0.97 PT, _ ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 86.7 The higher the score, the more efficient the home. , LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 58.5 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 14.00 _ 4. Number of Bedrooms 4 _ b. Central Unit Cap: 41.0 kBtu/hr 5. Is this a worst case? Yes _ SEER: 14.00 _ 6. Conditioned floor area (ft2) 3896 ft2 _ c. N/A _ 7. Glass type I and area: (Label reqd. by 13-104.4.5 if not default) a. U-factor: Description Area 13. Heat' syste (or Single or Double DEFAULT) 7a(Sngle Default) 613.0 ft' _ El 'c eat p Cap: 30.2 kBtu/hr _ b. SHGC: � HSPF: 8.60 (or Clear or Tint DEFAULT) 7b. (Tint) 613.0 ft2 I ct ( seat Pump Cap: 25.2 kBtu/hr 8. Floor types HSPF: 8.10 a. Raised Wood R=11.0, 198.0 ft2 _ c. N/A b. Slab -On -Grade Edge Insulation, 0 R=0.0, 196.0 ft2 c. 1 Others 177.0 ft2 _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 80.0 gallons a. Concrete, Int Insul, Exterior R=2431.0, 4.1 ft2 _ EF: 0.97 _ b. Frame, Wood, Adjacent R=312.0, 11.0 ft2 _ b. N/A c. N/A d. N/A _ c. Conservation credits _ e. N/A _ (HR-Heat recovery, Solar 10. Ceiling types DHP-Dedicated heat pump) a. Under Attic R=30.0, 1743.0 ft2 _ 15. HVAC credits PT, b. Under Attic R=30.0, 1827.0 ft2 _ (CF-Ceiling fan, CV -Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Unc. Ret: Unc. AH(Sealed):Interior Sup. R=6.0, 136.0 ft _ MZ-C-Multizone cooling, b. Sup: Unc. Ret: Unc. AH(Sealed):Garage Sup. R=6.0, 135.0 ft _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: ZHE ST,9��0� *NOTE: The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPADOE EnergyStarTmdesignation), your home may qualijy for energy efficiency mortgage (EEM) incentives ifyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf edu for information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487-1824. 1 Predominant glass type. For actual glass type and areas see Summer & Winter Glass output on ages 2&4. $nergyGauge® (Version: FLRCS�B v4.5) FORM 60OA-2004R EnergyGauge@ 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X. SPM X SOF = Points .18 3896.0 24.35 17076.0 1.Single, Tint W 2.0 15.0 20.0 47.90 0.99 945.0 2.Single, Tint E 2.0 15.0 60.0 53.27 0.99 3153.0 3.Singie, Tint S 6.0 14.0 78.0 9.84 0.73 2280.0 4.Single, Tint W 2.0 15.0 80. • 7.90 0.99 3781.0 5.Single, Tint E 2.0 15.0 0. 3.27 0.99 3678.0 6.Single, Tint E 2.0 1 .0 Z . .27 0.99 1576.0 7.Single, Tint N1 0 2Q�0 24.46 0.99 483.0 8.Single, Tint N . 2.0 1' - Y 36.0 24.46 0.98 866.0 9.Single, Tint E -. ,0 19.0 2.0 53.27 0.99 105.0 10.Single, in S 6.0 2.0 48.0 39.84 0.48 908.0 11.Single,1 t �E 2.0 5.0 40.0 53.27 0.81 1716.0 12.Single, Ti S 2.0 6.0 20.0 39.84 0.80 635.0 13.Single, Tin W 2.0 6.0 8.0 47.90 0.85 327.0 14.Single, Tint N 2.0 5.0 40.0 24.46 0.88 856.0 15.Single, Tint N 2.0 4.0 24.0 24.46 0.84 491.0 16.Single, Tint W 2.0 3.0 21.0 47.90 0.65 654.0 17.Single, Tint W 2.0 6.0 16.0 47.90 0.85 654.0 As -Built Total: 613.0 23108.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 11.0 0.70 7.7 1. Concrete, Int Insul, Exterior 2431.0 4.1 0.10 0.4 Exterior 4.1 1.90 7.8 2. Frame, Wood, Adjacent 312.0 11.0 0.20 2.2 Base Total: 15.1 15.5 As -Built Total: 15.1 2.6 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 216.0 4.80 1036.8 Exterior 344.0 4.80 1651.2 2.Exterior Insulated 128.0 4.80 614.4 Base Total: 344.0 1651.2 As -Built Total: 344.0 1651.2 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 3293.0 2.13 7014.1 1. Under Attic 30.0 1743.0 2.13 X 1.00 3712.6 2. Under Attic 30.0 1827.0 2.13 X 1.00 3891.5 Base Total: 3293.0 7014.1 1 As -Built Total: 3570.0 7604.1 EnergyGauge® DCA Form 60OA-2004R EnergyGauge@/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 196.0(p) -31.8-6232.8 1. Slab -On -Grade Edge Insulation 0.0 196.0(p -31.90 -6252.4 Raised- 375.0 -3.43-1286.3 2. Raised Wood, Adjacent 11.0 198.0 1.80 356.4 3. Raised Wood, Adjacent 11.0 177.0 1.80 318.6 R Base Total: -7519.0 As -Built Total: ,0 -6577.4 INFILTRATION Area XBSPM =Points TArea X SPM = Points 3896.0 14.31 55751.8 3896.0 14.31 55751.8 Summer Base Points: 73989.6 Sum l,*� 82640.3Bu Total Summer X System = Cooling Tota : p X Duct X System X Credit = Cooling Points Multiplier Points Compon6_h, Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 50500btuh ,SEER/EFF(14.0) Ducts: Unc(S), Unc(R), Int(AH), R6.0(INS) 82540 0.55 (1.09 x 1.150 x 0.90) 0.244 0.950 11859.2 (sys 2: Central Unit 41000btuh ,SEERIEFF(14.0) Ducts: Unc(S), Unc(R),Gar(AH), R6.0(INS) 82540 0.45 (1.09 x 1.150 x 0.95) 0.244 0.950 10163.2 73989.5 0.3250 24046.E 82640.3 1.00 1.156 0.244 0.950 22082.2 EnergyGaugeTTM DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT#: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 3896.0 9.11 6389.0 1.Single, Tint W 2.0 15.0 20.0 13.80 1.00 275.0 2.Single, Tint E 2.0 15.0 60.0 13.04 1.01 786.0 3.Single, Tint S 6.0 14.0 78! 10.88 1.22 1032.0 4.Single, Tint W 2.0 15.0 .• 13.80 1.00 1103.0 5.Single, Tint E 2.0 0 70.0 13.04 1.01 917.0 6.Single, Tint E 2 15A, 30.0 13.04 1.01 393.0 7.Single, Tint Y 2. 15 ' 20.0 15.38 1.00 307.0 8.Single, Tint N 2;0 -1`.0 36.0 15.38 1.00 552.0 9.Single, Tint 2'.0 19.0 2.0 13.04 1.00 26.0 10.Sing�le, i` S 6.0 2.0 48.0 10.88 2.29 1196.0 11.Sing' a Tin E 2.0 5.0 40.0 13.04 1.04 543.0 12.Singl nt '-; S 2.0 6.0 20.0 10.88 1.12 243.0 13.Single, : nt W 2.0 6.0 8.0 13.80 1.02 112.0 14.Single, Tint N 2.0 5.0 40.0 15.38 0.99 612.0 15.Single, Tint N 2.0 4.0 24.0 15.38 0.99 366.0 16.Single, Tint W 2.0 3.0 21.0 13.80 1.06 307.0 17.Single, Tint W 2.0 6.0 16.0 13.80 1.02 225.0 As -Built Total: 613.0 8995.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 11.0 1.80 19.8 1. Concrete, Int Insul, Exterior 2431.0 4.1 0.50 2.0 Exterior 4.1 2.00 8.2 2. Frame, Wood, Adjacent 312.0 11.0 0.70 7.7 Base Total: 15.1 28.0 As -Built Total: 15.1 9.8 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 1.Exterior Insulated 216.0 5.10 1101.6 Exterior 344.0 5.10 1754.4 2. Exterior Insulated 128.0 5.10 652.8 Base Total: 344.0 1754.4 As -Built Total: 344.0 1754.4 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 3293.0 0.64 2107.5 1. Under Attic 30.0 1743.0 0.64 X 1.00 1115.5 2. Under Attic 30.0 1827.0 0.64 X 1.00 1169.3 Base Total: 3293.0 2107.5 As -Built Total: 3570.0 2284.8 EnergyGauge® DCA Form 60OA-2004R EnergyGauge@)/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 196.0(p) -1.9 -372.4 1. Slab -On -Grade Edge Insulation 0.0 196.0(p 2.50 490.0 Raised 375.0 -0.20 -75.0 2. Raised Wood, Adjacent 11.0 198.0 1.80 356.4 3. Raised Wood, Adjacent 11.0 177.0 1.80 318.6 Base Total: -447.4 As -Built Total: ems .0 1165.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 3896.0 -0.28-1090.9 V 3896.0 -0.28 -1090.9 Winter Base Points: 8740.E Winte Na t"'fy oints: Cr' 13118.1 Total Winter X System = Heating Total k 4Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 30200 btuh ,EFF(8.6) Ducts: Unc(S), Unc(R), Int(AH), R6.0 13118.1 0.545 (1.078 x 1.160 x 0.92) 0.397 0.950 3101.7 (sys 2: Electric Heat Pump 25200 btuh ,EFF(8.1) Ducts: Unc(S),Unc(R),Gar(AH),R6.0 13118.1 0.455 (1.078 x 1.160 x 0.95) 0.421 0.950 2837.5 8740.6 0.5540 4842.3 13118.1 1.00 1.169 0.408 0.950 6939.3 EnergyGaugelm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 4 2460.00 9840.0 60.0 0.97 4 1.00 2333.20 1.00 9332.8 As -Built Total: 9332.8 .c?.3Yzcr�. CODE COMPLIA! CE T l US BASE' Ne A oAS -BUILT Cooling + Heating + Points Points Hot Water Points = T&al Points Cooling + Heating + Hot Water = Total Points Points Points Points 24047 4842 9840 38729 r 22082 5939 9333 37364 PASS o EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge@ 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: LOT 33, WATERSONG WAY, ST. LUCIE COUNTY, FL, PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterier & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames,.surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier'sbarderis installed that extends from and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless bac us r.' i t members. EXCEPTION: Frame floors where a contirtuo infilt i � arrier is installed that is sealed to the perimeter, penetrations ands s. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings`-genetratio of ceilin ' plane of top floor; around shafts, chases, ' sous soffits, chimne sa net ed to cont iri air barrier; gaps in gyp board & top plate; attic acres . C I N r a ceilings where a continuous infiltration barrier is installed the i ea l"d tf t a perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated lth no penetrations, sealed; or Type IC or non -IC rated, -installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. . 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with -efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed, in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. F1 EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5