Loading...
HomeMy WebLinkAboutNOA # 05-0602.03 ( 9-05-07 )FLORIDA MI�DADE -L MIRQiDADE AGL BUILDIN r E C-a G BUILDING CODE COMPLIANCE OFFICE (BCCO)140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 NOTICE OF ACCEPTANCE (NOA) (305) 375-2901 FAX (305) 375-2908 Atlas Roofing Corporation 2000 Rivgxe.,c1gG.�1, Atlanta, GA 30328 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority. Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade. County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AI3J may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the 'applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: FA 10 and FR 50 Fire -Retardant Slipsheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has,been filed and.there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has-been a revision or-charige:in the' - materials, use, and/or manufacture of the product or process. Misuse of this NOA'as.an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA.•-Failure to comply with any section of this NOA shall be cause for termination and removal of NOA: ADVERTISEMENT: The NOA number preceded by the" words; lVfiami-Dade .County' , Florida; and•ffoliowed by the expiration date may be displayed in advertising literatu`r--e. If any portion. of the-NOA is dispiayed, then it shall . . be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided fo ,the user by the manufacturer or -its distributors . and shall be available for inspection at the job site at the request of the. Building Official. ;= This NOA consists of pages 1 through 3. The submitted documentation was reviewed by,Jorge L. Acebo J NOA No.: 05-0602.03 . (( Expiration Date: 10/20/1b ; Approval. Date: 10/20/05 " =Page 1 of 3 _ . AFFINM ASIONtItOTS, P.A. �—- rHE REVIEW OF THESE DOCUMENTS IS STRICTLY FOR CONFORMANCE WITH THE DESIGN INTENT OF THE PROJECT AND FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS, FABRICATION AND : ONSTRUCTION MEANS AND METHODS, AND THE SEQUENCING OF SAID FABRICATION AND CON- STRUCTION WITH ANY AND ALL OTHER APPLI- CABLE TRADES INVOLVED. THE GENERAL REVIEW OF THESE DOCUMENTS BY THE ARCHITECT DOES NOT RELIEVE THE GENERAL CONTRACTOR FROM HIS RESPONSIBILITY FOR CONSTRUCTION AC- CORDING TO PERMIT DOCUMENTS AND ALL AR- PLI E REQUIREMENTS. o PR , NO EXCEPTIONS TAKEN VED WITH COMMENTS AS NOTED REVISE AS NOTED; RESUBMIT REJECTED- OMMENTS AS NOTED `ar • —~� DA ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: 07520 Underlayment Material: Fiberglass 1-SCOPE This acceptance is for FR 10 and FR 50 Fire -Retardant Slipsheets as manufactured by Atlas Roofing Corporation, as described in Section 2 of this Notice of Acceptance, for use with approved prepared roof assemblies. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Specification Description FR 10 48" x 250' rolls Physical Properties Non -Asphaltic fiberglass -based Fire - Retardant Slipsheet. FR 50 48" x 105' rolls Physical Properties Non -Asphaltic fiberglass -based Fire - Retardant Slipsheet. 3. LUMTATIONS 3.1 Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials UL Directory for fire ratings of this product 3.2 This acceptance is for prepared roofmg applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 FR 10 and FR 50 Fire -Retardant Slipsheets shall be installed in strict compliance with applicable Building Code. 4.2 FR 10 and FR 50 Fire -Retardant Slipsheets shall be installed with a minimum 2-inch head lap in a single layer fashion and fastened as required by the system assemblies NOA. 4.3 FR 10 and FR 50 Fire -Retardant Slipsheets are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance requirements. 4.4 FR 10 and FR 50 Fire -Retardant Slipsheets may be used with any approved roof covering Notice of Acceptance listing FR 10 and FR 50 Fire -Retardant Slipsheets as a component part of an assembly in the Notice of Accep' pr 'ce. If FR 10 and FR 50 Fire -Retardant Slipsheets are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or th Miami -Dade County Product Control Department for approval provided that a p o at documentation is provided to detail compatibility of the products, wind upli t t . c a fire testing results. 4.5 FR 10 and FR 50 Fire-Retatdahft glipsffeets are anon -As ltaltic underla p tza yrn nt hat ay be used as a fire -retardant for prepared roof assembl11'esjFo fide; classi�icatlon of pecific roof assemblies using FR 10 and FR 50 Fire-Re`Ta da�"Slip'ee. ,refer two a current Approved Roofing Materials UL Directory for fire rating"th`i ro'1ct ]? 5. LABELING 5.1 All packaging shall bear the imprint or identifiable marking of the manufacturer's name or - logo to identify the Product Standard designation. NOA No.: 05-0602.03 O Y - Expiration Date:10/20/10 Approval Date:10/20/05 ' Page 2 of 3 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 . This Notice of Acceptance. 6.1.2 A current Approved Roofing Materials UL Directory for fire ratings of this product. ± 6.1.3 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. 7. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories Inc. 01NK39956 ASTM E-108 12/13/01 99NK1.1055 06/04/99 97NK15618 06/09/97 END OF THIS ACCEPTANCE . ` o NOA No.: 05-0602.03 Expiration Date: 10/20/10 Approval Date: 10/20/05 Page 3 of 3