M I A M I-DADE F rm0,,-)APc0YTY, FLORIDA
_ METRO-DADE FLAGLER BUILDINGBUII,DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603
PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563
(305) 375-2901 FAX (305) 375-2908
NOTICE OF ACCEPTANCE (NOA)
South Florida Metal Supply
2783 SE Monroe Street
Stuart, FL. 34997
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. _
Tfre- documen a ion submitted as been reviewed-by'the BCCO and accepted by the Building Code and Product
Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having
Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the
AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality
assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur
the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or
material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO
that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
and the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Englert Series 2000 Aluminum Roof Panel.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this,product.
TERMINATION of this NOA will occur after the expiration date or if there has'been a revision or change�in the
materials, use, and/or manufacture of the product or process. Misuse of this•NOA as: an endorsement of.any
product, for sales, advertising or any other purposes shall automatically terminate:this NOA.'Failurd to, comply
with any section of this NOA shall be cause for termination and removal of NOA:
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida; and followed by
the expiration date may be displayed in advertising literature..., If any portion of the NOA is displayed; -then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to ihe: user by, the manufacturer or its" distributors
and shall be available for inspection at the job site at the request of the Building Official'.
This-NOA consists of pages 1 through 5.
The submitted documentation was,reviewed by Alex Tigera.
NOA No.: 07-0130.05 :.
Expiration Date:-03/23/12 -
.z Approval -Date: 03/23/07 '
:. Page 1 of 5 -
r
AFFINM ARCHM781 PA• `o---
rHE REVIEW OF THESE DOCUMENTS IS STRICTLY
FOR CONFORMANCE WITH THE DESIGN INTENT
OF THE PROJECT AND FOR COMPLIANCE WITH
THE CONTRACT DOCUMENTS. THE CONTRACTOR
IS SOLELY RESPONSIBLE FOR CONFIRMING AND
CORRELATING DIMENSIONS, FABRICATION AND
.ONSTRUCTION MEANS AND METHODS, AND THE
SEQUENCING OF SAID FABRICATION AND CON-
STRUCTION WITH ANY AND ALL OTHER APPLI-
CABLE TRADES INVOLVED. THE GENERAL REVIEW
OF THESE DOCUMENTS BY THE ARCHITECT DOES
NOT RELIEVE THE GENERAL CONTRACTOR FROM
HIS RESPONSIBILITY FOR CONSTRUCTION AC-
CORDING TO PERMIT DOCUMENTS AND ALL AP.
PV9A8t5wR8QE REQUIREMENTS.
PPROV , NO EXCEPTIONS TAKEN
A VED WITH COMMENTS AS NOTED
REVISE AS NOTED; RESUBMIT
REJECT QOWIVIMENTS AS N TED
7:
ROOFING ASSEMBLY APPROVAL:
Category
Roofing
Sub -Category:
07410 Non -Structural Metal Roofing
Material:
Aluminum
' Deck Type:
Wood
Maximum Design Pressure See Table A
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
-- Product__. .....
..Dimensions._
.-product
Specifications
Description
Series 2000
1= various
TAS 110
Aluminum, preformed, standing
w = 18"
TAS 125
seam panels.
Thickness 0.040"
Series 2000 Clip
min. 0.048"
TAS 114
Corrosion resistant, formed, steel
31/2" long x
clips for metal panel installation.
11/4" high
Trim Pieces
1= varies
TAS 110
Standard flashing and trim pieces.
w = varies
Manufactured for each panel width.
Thickness 0.040"
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Architectural Testing, Inc. 01-32796.01
Architectural Testing, Inc. 0146076.02
v�
Hurricane Test Laboratory, LLC. 0155-0404-04
Test Name/Report Date
TAS 100 Sep. 1998
TAS 125 10/23/03
ASTM E 8
TAS 125 04/1�6/0.VA
NOA No.: 07-0130.05
Expiration Date: 03/23/12
Approval Date: 03/23/07
Page 2 of 5
APPROVED ASSEMBLIES:
Deck Type:
Wood, Non -Insulated
Deck Description:
1%v, or greater plywood or wood plank.
Slope Range:
2":12" or greater
Maximum Uplift
Pressure:
See Table A Below
Deck Attachment:
In accordance with applicable Building Code,, but in no case shall it be
less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where
the deck is less than 19/32" thick (Minimum 15/32"). The above attachment
method must be in addition to existing attachment.
Underlayment:
Minimum underlayment shall be a ASTM D 226 Type 11 installed with
,a
minimum 4" side -laps and 6" end -laps. Underlayment shall be fastened
with corrosion resistant tin -caps and 11/a" annular ring -shank nails, spaced
6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll.
Or, any Miami -Dade County Product Control Approved underlayment
having a current NOA.
Valleys: Valley construction shall be in compliance with Roofing Application
Standard RAS 133 and with Englert's current published installation
instructions.
Fire Barrier Board: Any approved fire barrier having a current NOA. Or for a class A or B
fire rating, install minimum t/a" thick Georgia Pacific "Dens Deck" (wit
current NOA) or minimum 4mm thick of Tritex, RockRoof�-srth c e
NOA) or 5/8" water resistant type X gyp um9 sheatl}1 g t it li treat co e
and facer.
Metal Panels and ,:� ,,
Accessories: Install the "Series 2000 Parr" an 'ac' essories in compliance with the
current published installation instructions and details in Englert's
Installation Manual. Flashings, penetrations, valley construction and
other details shall be constructed in compliance with Roofing Application
Standard RAS 133. Male leg of snap seam shall be caulked with a
minimum %" bead of elastomeric construction sealant prior to installation
of female leg of panel.
Panels shall be installed with galvanize steel clips QW, long x 2 %2" wide
x 13/a" tall), attached to substrate with (2) two corrosion resistant #10-16
self -tapping pancake screws of sufficient length to penetrate through the
sheathing a minimum of 3/16". Clip fastening shall start 3" from panel end
and shall be at maximum spacing as described below in Table A.
TABLE A
MAXIMUM DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner
Maximum Design Pressures
—70 psf
—123.5 psf
Maximum Clip Spacing
24" o.c.
8" o.c.
1. Extrapolation shall not be allowed
NOA No.: 01-0130.05
" Y _ Expiration Date: 03/23/12
Approval Date: 03/23/07
Page 3 of 5
SYSTEM LIMITATIONS:
• 1. The maximum designed pressure listed herein shall be applicable to all roof pressure
zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall
be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended
corners and corners).
2. Panels shall be roll formed in continuous lengths from eave to ridge. Maximum lengths
shall be as described in Miami -Dade County Roofing Application Protocol RAS 133.
3. All panels shall be permanently labeled with. the manufacturer's name. and/or logo, and the
following statement: "Miami -Dade County Product Control Approved. All clips shall be
permanently labeled Englert, and/or logo, and/or model.
4. All products listed herein shall have a quality assurance audit in accordance with the
. Florida Building Code and Rule 9B-72 of the Florida Administrative Code.
5. Panels may be j obsite roll formed, with machine model #9080805 from Englert Inc.
NOA No.: 07-0130.05
©Y _ Expiration Date: 03/23/12
Approval Date: 03/23/07
Page 4 of 5
PROFILE DRAWING
SERIES 2000
18"
3/8
1 3/4"
PANEL
7 1/4"
1 3/4,.CLIP
-.. -r - --.. .
DAAIDI %A11TI-1 1-1 ID R GAQTr:K=DQ
END OF THIS ACCEPTANCE
NOA No.: 07-0130.05
Expiration Date: 03/23/12
Approval Date: 03/23/07