Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NOA # 07-0103.05 ( 9-05-07 )
09 P5107 M I A M I-DADE F rm0,,-)APc0YTY, FLORIDA _ METRO-DADE FLAGLER BUILDINGBUII,DING CODE COMPLIANCE OFFICE (BCCO) 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2908 NOTICE OF ACCEPTANCE (NOA) South Florida Metal Supply 2783 SE Monroe Street Stuart, FL. 34997 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. _ Tfre- documen a ion submitted as been reviewed-by'the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The BCCO (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BCCO reserves the right to revoke this acceptance, if it is determined by BCCO that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Englert Series 2000 Aluminum Roof Panel. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this,product. TERMINATION of this NOA will occur after the expiration date or if there has'been a revision or change�in the materials, use, and/or manufacture of the product or process. Misuse of this•NOA as: an endorsement of.any product, for sales, advertising or any other purposes shall automatically terminate:this NOA.'Failurd to, comply with any section of this NOA shall be cause for termination and removal of NOA: ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida; and followed by the expiration date may be displayed in advertising literature..., If any portion of the NOA is displayed; -then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to ihe: user by, the manufacturer or its" distributors and shall be available for inspection at the job site at the request of the Building Official'. This-NOA consists of pages 1 through 5. The submitted documentation was,reviewed by Alex Tigera. NOA No.: 07-0130.05 :. Expiration Date:-03/23/12 - .z Approval -Date: 03/23/07 ' :. Page 1 of 5 - r AFFINM ARCHM781 PA• `o--- rHE REVIEW OF THESE DOCUMENTS IS STRICTLY FOR CONFORMANCE WITH THE DESIGN INTENT OF THE PROJECT AND FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS, FABRICATION AND .ONSTRUCTION MEANS AND METHODS, AND THE SEQUENCING OF SAID FABRICATION AND CON- STRUCTION WITH ANY AND ALL OTHER APPLI- CABLE TRADES INVOLVED. THE GENERAL REVIEW OF THESE DOCUMENTS BY THE ARCHITECT DOES NOT RELIEVE THE GENERAL CONTRACTOR FROM HIS RESPONSIBILITY FOR CONSTRUCTION AC- CORDING TO PERMIT DOCUMENTS AND ALL AP. PV9A8t5wR8QE REQUIREMENTS. PPROV , NO EXCEPTIONS TAKEN A VED WITH COMMENTS AS NOTED REVISE AS NOTED; RESUBMIT REJECT QOWIVIMENTS AS N TED 7: ROOFING ASSEMBLY APPROVAL: Category Roofing Sub -Category: 07410 Non -Structural Metal Roofing Material: Aluminum ' Deck Type: Wood Maximum Design Pressure See Table A TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: -- Product__. ..... ..Dimensions._ .-product Specifications Description Series 2000 1= various TAS 110 Aluminum, preformed, standing w = 18" TAS 125 seam panels. Thickness 0.040" Series 2000 Clip min. 0.048" TAS 114 Corrosion resistant, formed, steel 31/2" long x clips for metal panel installation. 11/4" high Trim Pieces 1= varies TAS 110 Standard flashing and trim pieces. w = varies Manufactured for each panel width. Thickness 0.040" EVIDENCE SUBMITTED: Test Agency Test Identifier Architectural Testing, Inc. 01-32796.01 Architectural Testing, Inc. 0146076.02 v� Hurricane Test Laboratory, LLC. 0155-0404-04 Test Name/Report Date TAS 100 Sep. 1998 TAS 125 10/23/03 ASTM E 8 TAS 125 04/1�6/0.VA NOA No.: 07-0130.05 Expiration Date: 03/23/12 Approval Date: 03/23/07 Page 2 of 5 APPROVED ASSEMBLIES: Deck Type: Wood, Non -Insulated Deck Description: 1%v, or greater plywood or wood plank. Slope Range: 2":12" or greater Maximum Uplift Pressure: See Table A Below Deck Attachment: In accordance with applicable Building Code,, but in no case shall it be less than 8d annular ring shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum 15/32"). The above attachment method must be in addition to existing attachment. Underlayment: Minimum underlayment shall be a ASTM D 226 Type 11 installed with ,a minimum 4" side -laps and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 11/a" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12" o.c. in the field of the roll. Or, any Miami -Dade County Product Control Approved underlayment having a current NOA. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with Englert's current published installation instructions. Fire Barrier Board: Any approved fire barrier having a current NOA. Or for a class A or B fire rating, install minimum t/a" thick Georgia Pacific "Dens Deck" (wit current NOA) or minimum 4mm thick of Tritex, RockRoof�-srth c e NOA) or 5/8" water resistant type X gyp um9 sheatl}1 g t it li treat co e and facer. Metal Panels and ,:� ,, Accessories: Install the "Series 2000 Parr" an 'ac' essories in compliance with the current published installation instructions and details in Englert's Installation Manual. Flashings, penetrations, valley construction and other details shall be constructed in compliance with Roofing Application Standard RAS 133. Male leg of snap seam shall be caulked with a minimum %" bead of elastomeric construction sealant prior to installation of female leg of panel. Panels shall be installed with galvanize steel clips QW, long x 2 %2" wide x 13/a" tall), attached to substrate with (2) two corrosion resistant #10-16 self -tapping pancake screws of sufficient length to penetrate through the sheathing a minimum of 3/16". Clip fastening shall start 3" from panel end and shall be at maximum spacing as described below in Table A. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner Maximum Design Pressures —70 psf —123.5 psf Maximum Clip Spacing 24" o.c. 8" o.c. 1. Extrapolation shall not be allowed NOA No.: 01-0130.05 " Y _ Expiration Date: 03/23/12 Approval Date: 03/23/07 Page 3 of 5 SYSTEM LIMITATIONS: • 1. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 2. Panels shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Miami -Dade County Roofing Application Protocol RAS 133. 3. All panels shall be permanently labeled with. the manufacturer's name. and/or logo, and the following statement: "Miami -Dade County Product Control Approved. All clips shall be permanently labeled Englert, and/or logo, and/or model. 4. All products listed herein shall have a quality assurance audit in accordance with the . Florida Building Code and Rule 9B-72 of the Florida Administrative Code. 5. Panels may be j obsite roll formed, with machine model #9080805 from Englert Inc. NOA No.: 07-0130.05 ©Y _ Expiration Date: 03/23/12 Approval Date: 03/23/07 Page 4 of 5 PROFILE DRAWING SERIES 2000 18" 3/8 1 3/4" PANEL 7 1/4" 1 3/4,.CLIP -.. -r - --.. . DAAIDI %A11TI-1 1-1 ID R GAQTr:K=DQ END OF THIS ACCEPTANCE NOA No.: 07-0130.05 Expiration Date: 03/23/12 Approval Date: 03/23/07 Page 5 of 5