HomeMy WebLinkAboutPolyglass Product Approval2/1812021
Florida Building Code Online
a • a - � r
caps Mpme lup In user peplsaarlan Ho[lapks submit SUN,arye sdb a%Rs q,v.ar H, Can —Us
•'
M1 o r ( =--Approval
gwa: whla u,w
db
BCrssne Map
Unks swreh
^ph
> 6ek311i.y > 4ppuetlon aeon
- FL R
FL5259-R32
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer
POLYGLASS USA
Address/Phone/Email
1111 W. Newport Center Drive
Deartleid Beach, FL 33442
(9") 233-1330 F t20j
maipertfpolyglass.mm
Authorized Signature
Maury Alpert
malpert@polyglass.com
Technical Representative
TECH REP
Address/Phone/Emall
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-6017
uspolyglasstechnlcalfpoiygless.am
Quality Assurance Representative
QA REP
Address/Phone/Emall
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(BBB) 410-1375
uspolyglssstechnlal®polygless.cam
Category
Roofing
Subcategory
Underlayments
Compliance Method
Evaluation Report from a Florida Registered Architect or a
Licensed Florida
Prpfftdo ral ft4neer
Evaluation Report - Hardcopy Received
FO*de Englne4r or Architect Name who developed the Robert Nieminen
evAluat]on Report
Florida Ucense
PE-59166
Quality Assurance Entity
UL LLC
QunNW A> umnce Contract Expiration Date
12/23/2023
Vapdated By
Jahn W. Knezevlch, PE
Validation Checkllst - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
ASTM d�
ASTM D3970
YW
20
2015
ASTM D226
200909
ASTM D479B
2011
ASTM D6163
2015
ASTM 06164
2011
ASTM D6222
2011
ASTM D6509
2015
htfpeJAw.Hoddabullding.orgfpr/pr_app_d0.asp -?pemm wGEVXOwtDgvbSgAaZp3Crk2vS%2feg01iprWbXm6rrvBSiIFMZyU6p
%3d%3d
112
2118/2021 Florida Building Code Online
FM 4474
2011
fkSA(TRt. $rat`' E&MM
2018
TAS 103
2020
UL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Cade
Product Approval Method Method 1 Option D
Date Submitted 12/21/2020
Date Validated 12/21/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
aurrarrarjr4C Products
' F1oAdr Hurabor or Yams
�5799.7
Description
Polyglass Roof Underiayments
, Polyglass roof underiayments for use In FBC
HVHZ jurisdictions. 1
(HVHZ)
-
Llyi[of Ue-
inaEalWllon L4trrpctlgga_—_
Pp",. for use in HVHZ: as
�,g,�yry�72 11 ]02B
y
Approved For use outside HVHZ: No
Impact Roeietant: N/A
Vart0ed By: Rphevt Nleminen PE-59166
Design (Irossuror Ntl A
Created by Intkpendent Third Party: Yes
1
Other: Refer to ER Secllon 5 for Umlts of Use.
Evaluation Reports
YCJHDEAlAYf•1��[j5 FL5759•
Created by Independent Third Party: Yes
!
5259.2 Polyglass Roof Underiayments
Polyglass roof underlayments, for use In FBC
non-HVHZ Jurisdictions.T I
:(non-HVHZ)
Limits of use
Installation Instructions
T
Approved for use in HVHZ: No
Approved for use PatRdo HVHZ.• Yes
. &122 rstri ).Rol
Impact Resistant: NIA,
verified UrRobNt frlmnlrren PE-59166
I Design Pressure: tAUN-622.5
I Created by Independont Third Party: Yes
Other: 1.) The dcwgn Orellafr In this AppNEalRrn
evaluation Raports
. r.letea ro ana 134f 0,r undedayment system Fpr
fL5Z59 R32 aF20tR_ 12 2_1 _FINAI_S_II M
W. UnDER Yj.tF�(j$ }Z5754_
use In We root sysled & Refer to ER Setmn 5,8.3
tua r[y��•I ftYr1Z1^aof
for other systems and aswtismd mexrmum design
C—toot by tndep mda r! Third Party: Yes
PreeSufftc 2.i Refer w W Seplon 5 for Omer HIMN
of use.
frtyrYla :: ilea urn "'�we,�rr.neerex lam Dp-A;Am.aPa.rsz
me snw m noriaa a an aNeeo emrioye.. tm.rsre amrmr a m�, .�ys� :; :; � ::
tSder ryryr W.rmw aenraca an r�Ue �e.vea rfTw 1 xakm rrxneenraNgnrrweC.eraramnri r^MM. bretarne da.rm
rlorWa Y+n �n 5^aaraG�p r t' nt .� boar m.�I. n �m�ran imp pfmpm.yWysgrxr FS0.a1T.1N1 •gwr.rye w t n of 15115,
_ paPru r53. r.5. inntrap.p W Dpnnwin wNan rinM rlMnaa Ga,• hoar rra.ns.•xraa
d. Pe Abwrmrnr ..ah nn �•n.Y w�dm r�nRnhr.n�PsewrtHNwwlnN dYu.n to wNc n[e�t Gros do nw .•W bwpGl aI N#n. Srrrl.
P""' osrw..ae v rx�.r..rmr.. „aa.. ro.orer eAss. s. an.. ns..yn,
Ro4uct AP�P—q1A ,,W
RYHE
Credit Card
Safe
https:IAvvnv.8aridabullding.org/pr/pr app_O.Mpx?pemm�GEVXOwIDgvbSgAeZp3Crk2vS%2feg01iprWbXm5rfv5SilFMzyU6cw°/3d%3d y2
NEMO ' etc.
CertWcote ofAuthorizafion #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATIONe•
PWy)i M USA, Inc. Evart Mil Report 3m-PLYG-2048CER.A
1111 West Newport Center Drive FL5259•1132 (HVHZ)
Deerfield Beach, FL 33442 Date of Issuance: 12/21/2020
(954)233-1330
SLOPE:
This Evaluation Report is Issued under Rule 61GZG-3 and the applicable rules and regulations governing the use of
construction materials In the State of Florida. The documentatiois submitted has been reviewed by Robert Nleminen, P.E.
for use of the product under the Florida Building Code and Florida Bullding Coda, Residential Volume. The products
described herein have been evaluated for compliance with the 71' Edition (2020) florida OuiidfOg Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments, for use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONMUM CbmeuiiNce: This Evaluation Report is valid ontlI such time as the named product(s) changes, the referenced Quality
Assurance or production facility Ibcatlon(s) changes, or Code provisions that relate to the prodoct(s) change. Accoptance of
our Evaluation Reports by the named cllent Constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility locations}. NEMO ETC, t.LC requires a complete review Of Its Evaluation Report
refa tiye to updated Code requirements with each Code Cycle,
ADvMMEMEW: The Florida Product Approval Number (Kflj preceded try the wards-NEMo)stc EvaluRbW may be displayed
in advertlsing literature. If any portion of the Evaluation Report Is displayed, then it shall be done In its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the Jab site at the request of the Building official.
This Evaluation Report consists of pages 1 through 11.
Prepared by;
u;
Robert J.M. Nieminen, P.E. Ii 3
The lresseal appYrEr W as authorlxed by Mppr Nleminen, P E.
Florida flegistrotion No. 59166, Florida OCA ANE1983 an ulEWOVm7o. Thkdan eet serve as an electrpJeeyslgaed
document.
CEIiTIFICAnnN OF INDEPENDENCE:
1 NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluate.
2. NEMO ETC, LLC is not owned, uperased or conttbiled byaar Company manufacturing or distributing products it evaluates.
3. Robert NleminnA P.F. does not have nor will etgNire, a financial interest in any company manufacturing or distributing products for which the
eralwtwn Mpons ate being bwo-
4. Rpberi Memlmrk. P.E. dues not have, nor will acquire, a nnaNdal interest in any other entity Involved N the approval proceps of the produce.
S. Thlsisa bul"Cadeevadu Wn. Neither NEMO ETC, tLCnOr Robert Hleminen, P.E. are, Inany way,ihe0esigFler of Record for anypm*n an
Whleh INS ivalkilli Ripon, or previous verMons diertmf, Wwas used for permitting Or devgn guidance urde5s retained specifically Fortfwt
purpose.
02019 NEMO ETC, LLC
ROOFING COMPONENT EVALUATION: NEnno I etc
Product Category: Roofing
Sub -Category: Underlayment
Compliance statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the r Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
SaCtion Pro a standard year
RAS 115, TAS 110 Material standard ASTM D226 2009
TAS 110 Material standard ASTM D1970 2015
TAS 110 Material standard TAS 103 2020
TAS 110 Material standard ASTM D6163 2015
TA5110 Material standard ASTM D6164 2011
TAS 110 Material standard ASTM D6222 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
EntIN
IAA
B llBfrR
291a
Entltv
Exeminatlon
gt
Date
FRO(TST 600)
TAS 114(1)
11757.0801-1
8/13/2001
NEMO(TST 6049)
ASTM D1970
4-PLYG-18-w 03.10
3/29/2018
ERD MT 6049)
TMIm(C)
P174001.07
1/4/2007
NEMO(TST6049)
ASTM DI623,TA5103
4SICP-1RU03071B-RI
7/23/2010
ERD(TST6049)
ASTM 01623, TAS IM
P31030.1309-I
11/30/20M
NEMD (TsT 5049)
ASTM D6163
45-PLYG-SB-00201,19-A
1/24/2019
EBO nsr 049)
TAS 117(BI/TA5114(C)
P11030-1109-3
11/30/2D09
NEMD ITST 6049)
ASTM 06222
4SPLYG-1800205A 9-C
5/20/2019
ERD(TST 6049)
MD4 U977/TAS 103
M10301109-3
11/30/2009
NEMO(TST 50491
TAS 103
4SPLYG4"`NLIOJ1
10/8/2019
FRO(TST 6049)
ASTM 01970, U798
P373M.1011
10/19/2011
NEMO (TST6049)
TAS 103
M-PLYG18004.10.19-1
10/8/2019
FRO MT 6049)
TM 103
P403W 0a12-1
8/6/2012
NEMO(MISID49)
TM 103
4SPLYG-18-004.10 I3L
10/9/2019
FRO MT 6049)
ASTM D1623,TA5103
P40390A612-2
8/7/2012
NEMO(TST6049)
TA53(3
45-PLYG-180M12.19-F
12/18/2019
FRO M6049)
ASTM D1623, TAS 103
U1420.0912-3
9/11/2012
NEMO(TV 6049)
TM103
4J-PLYG-I9-SSUDL-OZA
1/2/2020
ERD(TST 109)
ASTM D6509
P375900113-1-RS
2/512OU
NEMO(TST6049)
ASTM 0070, D4798
4SPLYG-18-00401.20H
1/14/2020
FRO (TST 6049)
TAS 1140)
P3968003.13
3/4/2013
NEMO ITS 6049)
ASTM D1970,D4798
4SPLYG-19430401.20.K
1/14/2020
ERO ITST 6049)
ASTM D6164
P37590.03,13-3A
3/6/2013
NEMO (TST6049)
TAS 103 (tile sllppage)
45-PLYG-I8-DOL012QA
1/16/2020
FRO (TST 60491
ASTM 06164
P3759D.07.13-1
7/2/2013
NEMO JTSIF60491
ASTM 06164
45-PLYG-18-004 01.20 9
1/16/2020
ERO(MT6049)
ASTM 04601
PM940.09,13
9/4/2013
NEMO(TST6049)
TAS 103
PLYG-SC15855.0120 A
5/29/2020
FRO (TST6 191
ASTM 01623, TM 103
P45270.05.14
5/12/2014
NEMO(TST6049)
TM 103
4J-PLYG-2PSSUDL-01
7/6/2020
ERD(TST 6049)
ASTM DI623, TAS 103
602009.14-6
9/B/2O14
NEMO(TST 6049)
ASTM D6222
4q-PLYG-I9-SSM88-05A
7/23/2020
ERO(TST 5049)
TA5103
P44360.30.14-RS
10/7/2014
NEMD (TSTG049)
ASTM D4798,D3623
41-PLYG-I9-SSUDL-05A
9/10/2020
ERD ITsr 6049)
ASTM D3970, U798
P43290.30.14
10/17/20M
NEMD ITS 6049)
ASTM D1970
4J-PLYG-20-SSUDL-05A
9/30/2020
FRO(TST 6049)
TAS 114(1)
P39680 03 13
3/4/2013
NEMO(TST 5049)
TAS 103
4J-PLYG-20.S5UDL-OS,C
9/30/2020
ERD(TST 6049)
ASTM DI970, DaInS
PLYG-SCIO130 06 16-1
6/27/2016
REMO(TST 6049)
TAS 103
41-PLYG-20-SSU0L-13A
10/21/2020
FRO(TST 049)
ASTM D1623, TAS 103
PLYG-SC3013006. 152
6/27/2016
NEMO(TST 6M9)
ASTM D1970,04798
45-PLYG-18-00412.19.0
10/27/2020
FRO ITST6049)
TAS 103
PLYG-SC10130 06 16-3
6/27/2016
REMO(TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-i5WP-MA
12/15/2020
ERD(TST 5049)
TAS 103(tile slippage)
PLYG-SC13M 12.16
12/27/2016
UL(QUA9625)
qualityc"I"l
Servce ConFrmaOon(FL)
0/13/2018
ERD(TST 6049)
TAS 103(tlledlppage)
PLYG-SC12115 OR 17
B/8/2017
UL(QUA9625)
Quallry Control
Service Confirmatian(TX)
11/07/2019
ERO(T5T 6049)
TAS 103
PLYG-SC130350017
10/31/2017
UL(QUA9625)
qualityc"I"I
FlorNa BCIS
Current
NEMD ETC, LLG Evaluation Report 3m-PLYG-ZO FBCERA
Centii imre ufAuMorlmd-k32455 7' EDITION 12020) FBC HVHZ EVALUATION F1.5259-1132 (HVHZ)
Polyglass Reef UndedaYments Revision 29: 12/21/2020
Page 2 of 11
0N1U%cRfinl.+'
4.
PRODUCT DESCRIPTION:
Material5tandard
Plant(s)
Description
4.1
ASTM D6163
FL
fiberglass -reinforced, SBS modified bitumen base sheet
4.2
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
4.3
pElastoflex%G
D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
TA5103 (partial)
4.4
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
TAS 103 (partial)
4.5
PWyllie., G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
4.6
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
4.7
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
4.6
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
TAS 103 (partial)
,I<
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-m11 thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate surface
4.10
Polystick MTS Plus
ASTM D1970
FL, NV, PA,
Nominal 60-mil thick rubberized asphalt waterproofing
TA5103
TX
membrane, glass fiber reinforced, surfaced with poly -film
surface
4.11
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
TAS 103
membrane with a 190 g/mz polyester fabric surface
4,12
Polyeslek TU P
TAS 103
rL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a granular
surface
4.13
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, with a polyester fabric
surface
4.14
Polystick XFR
ASTM D1970
NV,TX
Nominal 110-mll thick rubberized asphalt waterproofing
TAS 103
membrane, glass fiber reinforced, surfaced with a textured
film surface
D,1 mrs is a Bwmmg code Evaluation. NBltW NEMO ETC, LLC nor Robert Nleminen, P.E, are, in anyway, the Designer of Record
for any protect on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is notfor use in FBC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not inelude evaluation of fire classification. Refer to FBC L%G for requirements and limitations
regarding roof assembly fire classification. Refer to FBC Z603 for requirements and llmllations concerning the use of foam
plastic insulation.
NEMO ETC, U.C. Evaluadan Report 3m-PLVG-20-FBCER.A
Cerdfimre afAuthnrlianon402455 7TM EDITION (2020) FBC HVHZ EVALUATION FL5259-R32 (HVHZ)
Polyglass Roof Undedayments ReWds 28: 12/21/2020
Page 3 of 11
ONEMOjetc.
5.5 Polyglass Roof Undedayinents may be used with any prepared roof cover where the product isswocally referenced within
F6C approval documents. If not listed, a request may be made to the Authority Having furWz:tlan foropproral based on this
owiluatlort combined with supporting data for the prepared roof coveTing.
5.6 wab
TABLE I: ROOF COVER CWTIW
FBCSecfron:
TA5110(510),
TA5110(511),
RA5115
k4s316, 11aa 120
RAS133
TA5110(511)
RAS730
Undedayment
Asphalt
Clay and Concrete Tile
Slate or Slate -
Shingles
Mechanical Attach
Adheshre-Set
Metal
Type Shingles
Wood
Elastobase
Yes
Yes
Yes
Yes
Yes
Yes
(ARemate to
In eur shrrr.
1-fins si-t,
(AIN—te to
iAtipvyrrcp
tnnetaano
0226, Type III
See 5.
SxSRI
D226, Type IIl
0221,T 10
0226T •A
ElaStobaseP
Yes
Yes
Yes
Yes
Yes
Yes
fAl""'Wm
Iat Rase Sheet,
tat Rate Sheet,
iWtel la*
(Alternate to
IAII—Min
022I Tv tR
5ee5 a)
Sees IIJ
D216,T rn
a21 T elp
02A,
Elastoflex S6 G
No
yes
Yes
(see 5 sU
No
No
No
£lastallWS5 G FR
No
Yes
No
No
No
No
PolyflexG
No
Yes
Yes
(5ee 5 fill
No
No
No
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
fsee 5 61
No
No
No
Pn ex SA PFR
_ N �• .
Yes
No
No
No
No
Polystick IR-XMTS
yes
No
No
No
Yes
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
V11
Polystick TU Max
No
Yes
Yes
(See 5 6.1)
yes
No
Yes
Polystick TUP
No
Yes
No
No
No
Yes
Polystick TUPlus
yes
Yes
Yes
see I"
Yes
Yes
Yes
Polystick%FR
Yes
Yes
No
Yes
Yes
Yes
5.6.1 Adhesive -set tile is limited to use of the Following underlayment / tile -adhesive combinations.
TABLE ILA: ALLOWABLE UNOERIAYMENTI7B1-AaREWA COMBINATION51
Underlayment
Adhesive
Florida Product
Approval
Polystick TU Max or Polystick TU Plus
DAP Foam'Touch'n Seal
StormBond Roof Tile Adhesive'
NOA20-0309.05
Polystick TU Max or Polystick TU Plus
Dupont "Tile Bond`" Roof The
Adhesive"
FL22525
Elastoflex 56 G, Polyflex G, Polyflex SA P, Polystick TU Max ar Polystick TU
ICP Adhesives and Sealants
Plus
"Polyset®AH-160"
NOA 17-0322,03
Polystick TU Max or Polystick TU Plus
ICP Adhesives and Sealants
"Polyset•
NOA 1g-0131.02
RTA-1'
' Referto Tile Manufacturers or Adhesive Manufacturers Florida Product Approval for Overturning Moment Resistance Performance.
NEN70 ETC, U.C. Evaluation Report 3m-PLY13-20-FBCER.A
[emit-fAulhor4atipn 432455 7�e EDITION I20ZO) FBC HVHZ EVALUATION FL5259-R321HVHZ)
Polyglass Roof UndedaymenN Revision 28: 12/21/2020
Page 4 of 11
5.7 Allowable SuhsLrates:
NNEMO I etc
.
TABLE 2; SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
underlayment
Application
Substrates(dttsillmdto
meet Mndloads for pripIM)
Type
Primer
Materfal(s)
Polystick IR-Xe, Polystick MTS Plus,
Polystick TU Max, Polystick TU P,
Polystick TU Plus, Polystick XFR,
Polyflex SA P or Polyflex SA P FR
self -adhering
Deck
ASTM D41
structural concrete
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P
Elastoflex 56 G or Elastoflex 56 G
FR
hot asphalt
Deck
ASTM D41
structural concrete
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase, Elastobase P
PolVflex G or Polyflex G FR
torch -applied
Deck
ASTM D41
structural concrete
Base Sheet
N/A
Elastobase, Elastobase P
5-8 Attachment LkmitatloR5-
Refer to Section 6
5.9 KIMM9MLimitations:
TABLE 3: EXPOSURE IIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure(days)
Elastobase, Elastobase P, PON12M G2 Base or Polyglass Base
Mechanically attached
30
Polystick lR-Xe
Mechanically attached
90
Polystick MTS Plus, Polystick TU Max, PolystickTU P, Polystick TU Plus or Polystick
XFR
Any type (per Table 1)
180
Elastoflex S6 G, Polyflex G or Polyflex SA P
Adhesive -set tile roof system
180
Elastoflex 56 G, Elastoflex 56 G FR, Polyflex G, Polyflex G FR, Polyflex SA P or
Polyflex SA P FR
Mechanically attached
UNLIMITED
5.10 Tile SIII)Wge limits[; ' When loading roof tiles on the underlayment In direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
&UxfmwnStaging Slope
Elastoflex S6 G or 56 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat
&-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-t1le stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
PolystickTU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
PolystickTU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohlblted wthout blttans
NEMO ETC, LlG Evaluation Report 3M-PLYG-20-FBCERA
[&fi afAathonmtinn N324 7' EDITION(2020) FBC HVHZ EVALUATION FL5259-R321HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 5 of 11
14NEMOI etc
6.1
.Polyglass Roof Underlayments shall be installed in accordance with Polyglass publlshcd installation instructions subject to
the Limitations set
forth in Section 5 herein and the specifics noted below.
6.2
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3
An p e Mies;
6.3-1
Deck Type l:
Waad, Norvirlwlated
Deck Description:
Min.19/92" plywood or wood plank
System Type E:
Underlayment mechanically fastened to deck
Underlayment:
One or more plies of Elastobase or Elastobase P with a minimum 4-inch side lap and 5-inch end lap,
mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps,
Surfacing:
FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles
6.3.2
Deck Type 1:
Wood, Non -Insulated
1340 Description:
Min. 19/32" plywood or wood Plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck -
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied or
Polyflex SA P, self -adhering
and back -nailed max. 12-inch o,c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for the stagging limitations.
6.3.3
Deck Type 1:
Wood, Non -Insulated
Deck Description:
ILNn. War plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied or
Polyflex SA P FR or Polystick TU P, self -adhering
and back -nailed max. 12-inch o.c. using FBC HVHZApproved nails and tin caps (FBC HVHZ 1517,5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations,
NEMO ETC, LLC• Evaluation Report 3m-PLVG-20-FBCER.A
Cedij7 teafAuth.6-1—M455 7" EDITION(2020) FBC HVHZ EVALUATION FL5259-R321HVH21
Polyglass Roof Underlaymenh Ravish. 28: 12121/2020
Page 6 of 11
ONEMOjetc.
6.3.4 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-Inch D.C. at the lap -edges and 12-Inch D.C.
in a grid -pattern between the overlaps.
Cap Ply:
Polystick IR-Xe self -adhering and back -nailed max.12-inch D.C. using FBC HVHZApproved nails and tin
caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
6.3.5 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 39/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.C. at the lap -edges and 12-inch D.C.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch D.C. using
FBC HVHZApproved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch D.C. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for the stagging
limitations.
6.3.6 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum flinch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZApproved nails and tin caps (FBC HVHZ 1517.5), 6-inch D.C. at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch D.C. using
FBC HVHZApproved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max, self -adhering and back -nailed max. 12-inch D.C. using FBC HVHZApproved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZApproved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles- Refer to Table 4 for tile stagging limitations.
NEMO ETC, LLC. Evaluation Report 3m-PLYG.20-FBCER.A
Cenhrale fA"Morhar/on g3145s 7'" EDITION (2020) FBC HVHZ EVALUATION F1.5259-1132 (HVHZ)
Polyglass Roof Underlayments Revision 28: 12/21/2020
Page 7 of 11
ONEIVIOletc.
6.3.7 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32' plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elasobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4. inch side lap and 6-Inch end lap, mechanically fastened to deck.
Fastening;
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-Inch o.c. at the lap -edges and 12-Inch o.c.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, selWebering and back -nailed max. 12-inch o.c. using
FBC HWHZApproved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechankally attached the roof system, metal panels, metal
shingles, wood shakes or wood shingles.. Refer to Table 4 for tile stagging limitations.
6.3.8 Deck Type 1:
Wood, Non-[nsulated
Deck Description:
Min. 19132" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch and lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-Inch o.c, at the lap -edges and 12-inch o.c.
in a grid -pattern between the overlaps.
Base Ply:
(Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max or Polystick TU Plus, self -adhering and back -nailed max. 12-Inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved adhesive -set the roof system. Refer to Table 1A for allowable the adhesives and
Table 4 for tile stagging limitations.
6.3.9 Deck Typia 1:
Wood, Non -Insulated
Deck Description:
Min.19/U' plywood orwood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 2-Inch side lap and 6-Inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 9-Inch o.c, at the lap -edges and 18-Inch o.c. In two (2)
equally spaced, staggered center rows.
Cap Ply:
Elastoflex S6 G applied in hot asphalt or
Polyflex G torch -applied
and back -nailed max. 12-Inch o.c. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table SA for
allowable tile adhesives and Table 4 fortlle stagging limitations.
NEMO ETC, U.C. EYalMI-
Raport 3m-PLYG-2
Cert�nRe ofAurhan:alion 432455 7^�EOITION (2020) FBC HVHZ EVALUATION FL5259�R32 32 (HVHZ) (HVHZ(
PoInlass Roof Undedayments Revision 28: 1212212OZO
Page 8 of 11
ONEMO]eft.
6.3.10 Deck Type 1:
Woad, Non -Insulated
Deck Description:
Min, 19/32" plywood or wood plank
System Type E:
Base sheet mechanically Fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch D.C. at the lap -edges and B-Inch D.C. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P, self -adhering and back -nailed max.12-Inch D.C. using FBC HVHZ Approved nalls and tin
caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for the stagging limitations.
6.3 11 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Min. 19/3V plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 2-Inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 38-1227.05), 9-Inch D.C. at the lap -edges and 18-inch D.C. in two (2)
equally Spaced, staggered center rows.
Cap Ply:
Elastoflex S6 G FR applied in hot asphalt or
Polyflex G FR torch -applied
and back -nailed max. 12-inch D.C. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for tile stagging
limitations.
6.3.12 Deck Type 1:
Wood, Non -Insulated
Deck Description:
Mln. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase or Elastobase P with a minimum 3-Inch side lap and 6-Inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch D.C. at the lap -edges and 9-inch D.C. In three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Cap Ply:
Polyflex SA P FR or PolystickTU P, self -adhering, self -adhering and back -nailed max. 12-inch D.C. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system. Refer to Table 4 for the stagging
limitations.
NENIO ETC, U.C. EVsluetlon Report 3m-PLYe-20-FBCER.A
Certlflrore fA,thorlmean 02155 7- EDITION (2020) FBC HVHZ EVALUATION FL5259.R321HVHZI
Pelygless Roof UnUerloyments Revlslon Zg: 12/21/2020
Page 9 of 11
ONEMOIetc.
6.3.13 j De* Type 1:
Wood, Nan -Insulated )
Deck Descrlptlon:
Min. 14j3;r plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P felt with a minimum 3-inch side lap and 6-inch end lap,
mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), B-inch o.c. at the lap -edges and 8-inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached tile roof system, metal panels, metal
shingles, slate, slate -type shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging
limitations.
6.3.14 Deck Type It
Wood, Non-hisufated
Deck Description:
Min. 1V32' plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch c.c. at the lap -edges and 8-inch o.c, in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c. using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max, self -adhering and back -nailed max. 12-inch o,c, using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved mechanically attached tile roof system, metal panels, metal shingles, wood shakes
or wood shingles. Refer to Table 4 for tile stagging limitations.
6.3.15 Deck Type 1:
Wnod, Non -Insulated
Dark Description:
Kn. 19132` plywoed or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of Elastobase, Elastobase P or FBC HVHZ Approved ASTM D226, Type II felt with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
Simplex MAXX Cap Fastener (NOA 18-1227.05), 8-inch o.c. at the lap -edges and 8-inch o.c. In three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus or Polystick XFR, self -adhering and back -nailed max. 12-inch o.c, using
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ Approved nails and
tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved asphalt shingles, mechanically attached the roof system, metal panels, metal
shingles, wood shakes or wood shingles. Refer to Table 4 for tile stagging limitations.
NEMO ETC, LLC, Evaluation Report 3nn-PLYG-20-FBCER.A
[erti(mre o/AuMorizo[ian p32a55 77" EDITION(2020) FBC HVHZ EVALUATION FL5259-R32(HVHZ)
Polyglass Roof Undedayman/ Revision 29; 12/22/2020
Page 10 of 11
ONEIVIOletc
6.3.16 1Deck Type 1:
Wood, Non -Insulated
DerkDescription:
Min. 19/32`plywood orwood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plles of Elastobase, Elastobase P or FOC HVHZ Approved ASTM D226, Type If felt with a
minimum 44nch side lap and 64ch end lap, mechanically fastened to deck.
Fastening:
Simplex MMO(Cap Fastener [NOA IS-1227.05), 8-Inch o.c. at the lap -edges and B-Inch o.c. in three (3)
equally spaced, staggered center rows.
Primer:
PG100 or ASTM D41 primer applied to stress plates
Base Ply:
(Optional) Polystick MTS Plus, self -adhering and back -nailed max. 12-inch o.c. using FBC HVHZ
Approved nails and tin caps (FBC HVHZ 1517.5)
Cap Ply:
Polystick TU Max of Polystick TU Plus, self -adhering and back -nailed max.12-inch o.c. using FBC HVHZ
Approved nells and tin caps (FBC HVHZ 1517.5).
Surfacing:
FBC HVHZ Approved adheshm-set the roof system. Refer to Table SA for allowable tile adhesives and
Table 4 for tile stagging ilml[sllons.
6.3.17 Deck Type3:
Structural concrete, non -insulated
Deck Description:
Min. 2,500 psi structural concrete
System Type F:
Underlayment adhered
Primer:
ASTM D41
Underlayment:
Elastoflex 56 G applied in hot asphalt or
PolyRex G torch -applied or
PoiyBex SA P, self -adhering
Surfacing:
FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 1A for allowable the adhesives and
Table 4 for tile stagging limitations.
6.3.18 Deck Type 3:
Structural concrete, nonAnsulated
Deck Description:
Min 2300 psi structural concrete
System Type F:
Underlayment adhered
Primer:
ASTM D41
Base Ply:
(Optional) Polystick MTS Plus, self -adhering
Cap Ply:
Polystick TU Max or Polystick TU Plus, self -adhering
Surfacing:
FBC HVHZ Approved adhesive -set tile roof system. Refer to Table 3A for allowable the adhesives and
Table 4 for die stagging limitations.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the irtstallation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entityfor manufacturing facilities covered by F.A.C- Rule 61G20-3 CIA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
01LLC—CIUA9625; (414)Z40-6409; Karen. buchmannWul.com
- END OF EVALUATION REPORT -
NEMD ETC, LLC. Evaluanun Report 3m-PLY0.20-F8CER.A
Ce,epmre BfAuteoh an B32455 7' EDITION(2020) FBC HVHZ EVALUATION FL5ZS9-R321HVHZ)
Polyglass Roof Undedaymen6 ReVblon ZB: 12/21/2020
Page 11 of 11