HomeMy WebLinkAboutSt Lucie Roofing App (1)UK`n�,
L7 L 0 L Li L tz
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,6,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,5,6,7
Wood Shingles and
Shakes
A, B. D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,6,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4,
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RoofinfoFeb21 Rev Feb 18, 2021
Section A (General Information)
Master Permit No. Process No.
Contractors Name: Celewa ' Li nse # C� ®o�
-�
Job Address ` 00
❑ Low Slope
Asphaltic Shingles
❑ New roof ❑ Repair
Low Slope Roof Area (SF)
ROOF CATEGORY
❑ Mechanically Fastened Tile
❑ Metal Panel/Shingles
❑ Prescriptive BUR-RAS 15(
ROOF ROOF TYPE.
❑ Maintenance
. ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) _
❑ Mortar/Adhesive Set Tiles
Mood Shingles/Shakes
Reroofing ❑ Recovering
Total (SF) �" ` 1
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
3
T..Ul
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': — Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approva
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(
Anchor/Base Sheet Fastener/Bondin Mater
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows_ @ "ac
Zone 1:--
." oc @ Lap, # Rows @ "oc
Zone 2:_.._."
oc @ Lap, # Rows "oc
Zone 3:--"
oc @ Lap, # Rows_ @ "0
Number of Fasteners Per Insulation Board:
e 1: Zone 2: Zone 3
ust0"�,Mean
panents Noted and Details as Applicable:
o, Gutter, Edge Termination, Stripping,
Fla ,tinuous Cleat, Cant Strip, Base Flashing,
Courtg, Coping, Etc.,
IndicRoof Height, Parapet Height, Height of Base
shonent Material, Material' Thickness, Fastener
Ty , Fastener Spacing or Submit Manufacturers Details that
Com with RAS 111 and Chapter 16..
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number:
�pupI,0_
Minimum Design Wind Pressures, If Applicable (From RAS 127 or calculations):
Zone 1: Zone 2e: Zone 2n:_7one 2r.._Zone 3e: Zone 3r:
Deck Type: c
Type Underiayment: Q f- eK A ee y-6; I A-vwQ iW6
Roof Slope:
12
Insulation:F-,Aj
,
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing: r `�
Adhesive Type: 7,4
Type Cap Sheet:
Mean Roof Height: Roof Covering: �Lr
Type & Size Drip 3 7i ,�
Edge: =��Y r���
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mf values
are greater than or equal to the
Mrvalues, for each area of the roof, then the the attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1:
X = �� Mg; = Mn Product Approval Mi
(Zone 2e:
_ X _ �� - Mg; = M . Product Approval Mf.
(Zone 2n:
x )L= -) - Mg: = M,,,, Product Approval Mf
(Zone 2r: -
x)L= �} - Mg: = M Product Approval Mf
(Zone 3e:
X X Mg: = Mra. Product Approval Mf
(Zone 3r: '
x)L_ - _} " Mg: = Mrar Product Approval Mf
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance
(Mr) From Table Below Product Approval Mr
Mr required Moment Resistance*
Mean Roof Height Roof Slope
15,
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34,4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.
30.1
31.6
32.8
34.9
6:12
26.4
28.
29.4
30.5
32.4
7:12
24.4
25.
27.1
28.2
30.0
Must be used in conjunction with a list of mo ent b ed t" systems
• For Uplift based file systems use Method 3. Co
pare val es for F' with the values for Fr If the F' values are greater than or
equal to the Fr values, for each are f the roof,
t enth ile af4chment method is acceptable.
M hod 3 "Upli
Base` Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= )
c r =Fri Product Approval F'
(Zone 2e: x L =x W:= -
cos =Fr2e Product Approval F'
(Zone 2n: x L =x W:= -
cos r =Fr2n Product Approval F'
(Zone 2r: x L =x W:=_____)
cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:=_) -
cos r =Fr3e Product Approval F'
(Zone 3r: x L =x W:=____j -W:
cos r =Fr3r Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
6
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
Mg
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mg
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of
permit application.