HomeMy WebLinkAboutNOA 18-0619.05 (1)MIAMAM
�`" 1
MMMI-DADS COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.2ov/economy
IKO Industries Ltd.
120 Hay Road
Wilmington, DE 19809
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ArmourShake Asphalt Shingle
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 10-1122.03 and consists of pages 1 through 4.
The submitted documentation was reviewed by Hamlev Pacheco. P.E.
MAMI Wry NOA No.: 18-0619.05
1 , � 3 Expiration Date: 11/21/23
VWry
Approval Date: 08/23/18
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Cateszory
Roofing
Sub-Catetory:
Asphalt Shingles
Materials
Laminate
Deck Type:
Wood
SCOPE
This approves ArmourShake manufactured by IKO Industries Ltd. as described in this Notice of Acceptance, designed
to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code.
PRODUCT DESCRIPTION
Product Dimensions Test
Specifications
ArmourShake 18'/2" x 371/8" TAS 110
MANUFACTURING LOCATION
1. Sumas, WA,
EVIDENCE SUBMITTED
Test Auncv Test Identifier
PRI Construction Materials Inc. IKO-053-02-01
IKO-071-02-01
FM Approvals 3043171
3040947
Product Description
A heavy weight, fiberglass reinforced laminate
asphalt shingle.
Test Name/Revort
TAS 100
ASTM D 3462
ASTM E 108
ASTM D 3161 (TAS-107)
Date
01/19/10
04/06/ 11
11/11/11
11/17/10
NOA No.: 18-0619.05
Expiration Date: 11/21/23
Approval Date: 08/23/18
Page 2 of 4
LINIITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail 'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
APPRf}YED
BUILDING PERMIT REQUIREMENTS
Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
MIAMats Cou
NOA No.: 18-0619.05
Expiration Date: 11/21/23
Approval Date: 08/23/18
Page 3 of 4
DETAIL A
ARMOURSHAKE COURSE LAYOUT
NOTE:
1ST COURSE - FULL SHINGLE,
2ND COURSE - REMOVE 5-5/8"
3RD COURSE — REMOVE 11-1/4"
4TD COURSE - REMOVE 16-7/8"
5T" COURSE - REMOVE 22-1/2"
6T11 COURSE — REMOVE 28-1/8"
7Tx COURSE —FULL SHINGLE
DETAIL. B
ARMOURSHAKE NAILING PATTERN
AX LINE
NOTE: USE BUILT IN NOTCH TO DETERMINE PROPER EXPOSURE. NAILS SHALL PENETRATE THE
SHINGLE UNDERNEATH.
END OF THIS ACCEPTANCE
NOA No.: 18-0619.05
r�snr� �� N Expiration Date: 11/21/23
`, Approval Date: 08/23/18