HomeMy WebLinkAboutEnergy Efficiency Code 10-12-120
FORM 405-10
. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: GREEN RESIDENCE
Builder Nam x .
Street:
Permit Office _
L
ti
City, State, Zip: ST. LUCIE COUNTY, FL,
Permit Numb '=
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (1696.0 sqft.)
Insulation Area
a. Frame - Wood, Exterior
R=19.0 1696.00 ftz
2. Single family or multiple family Single-family
b. N/A
R= ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
Number of Bedrooms 3
d. N/A
10. Ceiling Types (2321.0 sqft.)
R= ft24.
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2321.00 ft2
6. Conditioned floor area above grade (ftz) 2321
b. NIA
R= ftz
c. N/A
R= ft2
Conditioned floor area below grade (ftz) 0
11. Ducts
R ft2
7. Windows(305.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 185
a. U-Factor: Sgl, U=0.55 245.00 ft2
SHGC: SHGC=0.30
Cooling systems
kBtu/hr Efficiency
b. U-Factor: Sgl, U=1.30 60.00 ft212.
.30
a. Central Unit
47.0 SEER:13.00 -
SHGC: SHGC= .64
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.0 HSPF:7.70
SHGC:
Area Weighted Average Overhang Depth: 6.879 ft.
Area Weighted Average SHGC: 0.367
14. Hot water systems
a. Electric Tankless
Cap:1 gallons
8. Floor Types (2321.0 sqft.) Insulation Area
EF: 0.717
a. Slab -On -Grade Edge Insulation R=0.0 2321.00 ftz
b. Conservation features
b. N/A R= ft2
None
c. WA R= ft2
15. Credits
CF, Pstat
Total Proposed Modified Loads: 34.71
PASS
Glass/Floor Area: 0.131
Total Standard Reference Loads: 46.00
I hereby certify that the plans and specifications covered by
Review of the plans and
O�THE STgp�
this calculation are in compliance with the Florida Energy
specifications covered by this�`,�
Off,
Code. -
calculation indicates compliance,,
with the Florida Energy Code.
+nM:''%.=='•'':,� �
a:...
PREPARED B
Before construction is completed
0
DATE:
this building will be inspected for
553.908
compliance with Section
# W u
I hereby certify that this building, designed, is in compliance
Florida Statutes.
COD WvV
with the Florida Ene yCode.
OWNER/ NT•_
BUILDING OFFICIAL:
DATE:
DATE:
,RECEIVED
OCT 1 2 2012
PERMIT11 C
St. Lucie Cour y, FL
10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software j Page 1 of 5
At,
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
GREENRESIDENCE
User
1
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2321
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
I Whole House Fan:
Address Type: Street Address
Lot #
Block/SubDivision:
PlatBook:
Street:
County: ST. LUCIE COUNTY
City, State, Zip: ST. LUCIE COUNTY,
FL,
CLIMATE
i
Design Location
j IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90
70
75 722 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2321, I 18568
SPACES
I
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
i
2321 18568 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio MI in 156 ft 0
2321 ft'
____ 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials I Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip Composition shingles 2514 ftz 0 ftz Medium
0.96
No 0.9 . No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300
2321 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 2321 ft'
I`
0.11 Wood
I
10/8/2012 8:21 AM EnergyGauge, USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
t
Adjacent
Cavity Width Height Sheathing Framing Solar
Below
Space
_ArpaR--Valne
o
_ 1
N
Exterior Frame - Wood
Main
19 78 8
624 ft? 0
0 0.75
0
— 2
E
Exterior Frame - Wood
Main
19 28 8
224 ft' 0
0 0.75
0
_ 3
S
Exterior Frame - Wood
I
Main
19 78 8
624 ftz 0
0 0.75
0
_ 4
W
Exterior Frame - Wood
Main
19 28 8
224 ftz 0
0 0.75
0
DOORS
#
Omt
Door Type
I Space
Storms
U-Value Width
Area
Ft In
FHeigh In
1
N
Insulated
I Main
None
0.460000 3
6 8
20 ft'
2
N
Insulated
I Main
None
0.4 3
6 8
20 ftz
I
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
II
Overhang
#
Omt ID Frame
Panes
NFRC
U-Factor SHGC
Area Depth Separation
Int Shade
Screening
1
N 1 Vinyl
Single (Tinted)
Yes
0.55 0.3
80 ftz 2 ft 0 in 7 ft 0 in
Drapes/blinds
None
2
N 1 Vinyl
Single (Tinted)
Yes
0.55 0.3
27 ft' 2 ft 0 in 7 ft 0 in
Drapes/blinds
None
3
N 1 Vinyl
Single (Tinted)
I Yes
0.55 0.3
6 ftz 10 ft 0 in 8 ft 0 in
Drapes/blinds
None
4
E 2 Vinyl
Single (Tinted)
Yes
0.55 0.3
12 ftz 2 ft 0 in 6 ft 0 in
Drapes/blinds
None
5
S 3 Vinyl
Single (Tinted)
Yes
0.55 0.3
120 ftz 10 ft 0 in 6 ft 0 in
Drapes/blinds
None
6
W 4 Vinyl
Single (Tinted)
Yes
1.3 0.64
60 ftz 10 ft 0 in 6 ft 0 in
Drapes/blinds
None
�I
INFILTRATION
#
Scope
Method
ILA
CFM 50 ELA Egl-A ACH ACH 50
1 Wholehouse Best Guess
0.000600
3044.01 167.112 314.278 0.36500 9.83630
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
None'
HSPF: 7.7
34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Nonel
I
SEER: 13
47 kBtu/hr 141.0 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use SetPnt
Conservation
1
Electric
Tankless
Mail
0.66 1 gal 60 gal 120 deg
None
10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
i
.
SOLAR HOT WATER SYSTEM
FSEC
I
Collector
Storage
Cert #
Company Name
System Model # Collector Model
It
Area
Volume
FEF
None
None
ft2
DUCTS
/
— Supply
—
— Return—
Air
Percent
HVAC #
v #
Location R Value Area
I
Location
Area Leakage Type
Handler CFM 25 Leakage
ON
RLF
Heat Cool
1
Attic 6
185 ft2
I
Attic
25 ft2 Default Leakage
Main
(Default) (Default) %
1 1
TEMPERATURES
Programable Thermostat: Y
I Ceiling Fans:
Cooling Jan
Heating Jan
Feb
Feb
Mar
Mar
HX
[ ] Apr (]
A- [
May [X] Jun . rX] Jul
] May i ]Jun [ j Jul
[X] AugX]
i ]AuI
j
Se Oct
Sep Oct
Nov
f X� Nov
Dec
Dec
Venting Jan
Feb
Mar
Apr [)
may [ 1 Jun [[[ ] Jul
[ I Aug
[)
Se Oct
[X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78 78 78
78 78 78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating(WD)
AM
PM
66
68
66
68
I 66
I 68
66 66 68
68 68 68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
PM
68
68
8
68 68 68
68
68
68
68
66
66
i
i
I
I
10/8/2012 8:21 AM EnergyGauge i USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
I
- FORM 405-10
ADDRESS:
Florida Code Compliance Checklist
Florida DepalI ment of Business and Professional Regulations
Residential Whole Building Performance Method
PERMIT #:
ST. LUCIE COUNTY, FL,
MANDATORY REQUIREMENTS SUMMARY r See individual code sections for full details.
COMPONENT
SECTION
I
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All iducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be (considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
framing shall not be used as supply ducts.
Building cavities
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation systems shall not exceed the minimum ASHRAE 62 level.
ventilation
No Imake-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
theimal efficiency=78% (82% after 4116/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
m or ore stages.
Ceilings/knee walls
405.2.1
R'1
19 space permitting.
10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
i