Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 10-12-120 FORM 405-10 . FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GREEN RESIDENCE Builder Nam x . Street: Permit Office _ L ti City, State, Zip: ST. LUCIE COUNTY, FL, Permit Numb '= Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (1696.0 sqft.) Insulation Area a. Frame - Wood, Exterior R=19.0 1696.00 ftz 2. Single family or multiple family Single-family b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ft2 Number of Bedrooms 3 d. N/A 10. Ceiling Types (2321.0 sqft.) R= ft24. Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2321.00 ft2 6. Conditioned floor area above grade (ftz) 2321 b. NIA R= ftz c. N/A R= ft2 Conditioned floor area below grade (ftz) 0 11. Ducts R ft2 7. Windows(305.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 185 a. U-Factor: Sgl, U=0.55 245.00 ft2 SHGC: SHGC=0.30 Cooling systems kBtu/hr Efficiency b. U-Factor: Sgl, U=1.30 60.00 ft212. .30 a. Central Unit 47.0 SEER:13.00 - SHGC: SHGC= .64 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:7.70 SHGC: Area Weighted Average Overhang Depth: 6.879 ft. Area Weighted Average SHGC: 0.367 14. Hot water systems a. Electric Tankless Cap:1 gallons 8. Floor Types (2321.0 sqft.) Insulation Area EF: 0.717 a. Slab -On -Grade Edge Insulation R=0.0 2321.00 ftz b. Conservation features b. N/A R= ft2 None c. WA R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 34.71 PASS Glass/Floor Area: 0.131 Total Standard Reference Loads: 46.00 I hereby certify that the plans and specifications covered by Review of the plans and O�THE STgp� this calculation are in compliance with the Florida Energy specifications covered by this�`,� Off, Code. - calculation indicates compliance,, with the Florida Energy Code. +nM:''%.=='•'':,� � a:... PREPARED B Before construction is completed 0 DATE: this building will be inspected for 553.908 compliance with Section # W u I hereby certify that this building, designed, is in compliance Florida Statutes. COD WvV with the Florida Ene yCode. OWNER/ NT•_ BUILDING OFFICIAL: DATE: DATE: ,RECEIVED OCT 1 2 2012 PERMIT11 C St. Lucie Cour y, FL 10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software j Page 1 of 5 At, PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: GREENRESIDENCE User 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2321 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: I Whole House Fan: Address Type: Street Address Lot # Block/SubDivision: PlatBook: Street: County: ST. LUCIE COUNTY City, State, Zip: ST. LUCIE COUNTY, FL, CLIMATE i Design Location j IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 2321, I 18568 SPACES I Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main i 2321 18568 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MI in 156 ft 0 2321 ft' ____ 0 0 1 ROOF / V # Type Roof Gable Roof Materials I Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 2514 ftz 0 ftz Medium 0.96 No 0.9 . No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2321 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 2321 ft' I` 0.11 Wood I 10/8/2012 8:21 AM EnergyGauge, USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS t Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ArpaR--Valne o _ 1 N Exterior Frame - Wood Main 19 78 8 624 ft? 0 0 0.75 0 — 2 E Exterior Frame - Wood Main 19 28 8 224 ft' 0 0 0.75 0 _ 3 S Exterior Frame - Wood I Main 19 78 8 624 ftz 0 0 0.75 0 _ 4 W Exterior Frame - Wood Main 19 28 8 224 ftz 0 0 0.75 0 DOORS # Omt Door Type I Space Storms U-Value Width Area Ft In FHeigh In 1 N Insulated I Main None 0.460000 3 6 8 20 ft' 2 N Insulated I Main None 0.4 3 6 8 20 ftz I WINDOWS Orientation shown is the entered, Proposed orientation. Wall II Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Single (Tinted) Yes 0.55 0.3 80 ftz 2 ft 0 in 7 ft 0 in Drapes/blinds None 2 N 1 Vinyl Single (Tinted) Yes 0.55 0.3 27 ft' 2 ft 0 in 7 ft 0 in Drapes/blinds None 3 N 1 Vinyl Single (Tinted) I Yes 0.55 0.3 6 ftz 10 ft 0 in 8 ft 0 in Drapes/blinds None 4 E 2 Vinyl Single (Tinted) Yes 0.55 0.3 12 ftz 2 ft 0 in 6 ft 0 in Drapes/blinds None 5 S 3 Vinyl Single (Tinted) Yes 0.55 0.3 120 ftz 10 ft 0 in 6 ft 0 in Drapes/blinds None 6 W 4 Vinyl Single (Tinted) Yes 1.3 0.64 60 ftz 10 ft 0 in 6 ft 0 in Drapes/blinds None �I INFILTRATION # Scope Method ILA CFM 50 ELA Egl-A ACH ACH 50 1 Wholehouse Best Guess 0.000600 3044.01 167.112 314.278 0.36500 9.83630 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None' HSPF: 7.7 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Nonel I SEER: 13 47 kBtu/hr 141.0 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Mail 0.66 1 gal 60 gal 120 deg None 10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 i . SOLAR HOT WATER SYSTEM FSEC I Collector Storage Cert # Company Name System Model # Collector Model It Area Volume FEF None None ft2 DUCTS / — Supply — — Return— Air Percent HVAC # v # Location R Value Area I Location Area Leakage Type Handler CFM 25 Leakage ON RLF Heat Cool 1 Attic 6 185 ft2 I Attic 25 ft2 Default Leakage Main (Default) (Default) % 1 1 TEMPERATURES Programable Thermostat: Y I Ceiling Fans: Cooling Jan Heating Jan Feb Feb Mar Mar HX [ ] Apr (] A- [ May [X] Jun . rX] Jul ] May i ]Jun [ j Jul [X] AugX] i ]AuI j Se Oct Sep Oct Nov f X� Nov Dec Dec Venting Jan Feb Mar Apr [) may [ 1 Jun [[[ ] Jul [ I Aug [) Se Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 68 I 66 I 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) PM 68 68 8 68 68 68 68 68 68 68 66 66 i i I I 10/8/2012 8:21 AM EnergyGauge i USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 I - FORM 405-10 ADDRESS: Florida Code Compliance Checklist Florida DepalI ment of Business and Professional Regulations Residential Whole Building Performance Method PERMIT #: ST. LUCIE COUNTY, FL, MANDATORY REQUIREMENTS SUMMARY r See individual code sections for full details. COMPONENT SECTION I SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All iducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be (considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 framing shall not be used as supply ducts. Building cavities Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation systems shall not exceed the minimum ASHRAE 62 level. ventilation No Imake-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum theimal efficiency=78% (82% after 4116/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two m or ore stages. Ceilings/knee walls 405.2.1 R'1 19 space permitting. 10/8/2012 8:21 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software i Page 5 of 5