Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GREEN RESIDENCE Builder Name: Street: Permit Office: City, State, Zip: ST. LUCIE COUNTY, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types.(1696.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=5.4 1696.00 ftz 3. Number of units, if multiple family 1 b. N/A c. N/A R= ft2 R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (2321.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2321.00 ft2 6. Conditioned floor area above grade (ft2) 2321 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(305.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: RoomsihBlocki 6 185 a. U-Factor: Sgl, U=0.55 245.00 ftz SHGC: SHGC=0.30 b. U-Factor: Sgl, U=1.30 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.64 a. Central Unit 47.0 SEER:13.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.0 HSPF:7.70 SHGC: Area Weighted Average Overhang Depth: 6.879 ft. ` Area Weighted Average SHGC: 0.367 ' 14. Hot water systems 8, Floor Types (2321.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=.0.0 2321.00 ft2 b. Conservation features EF: 0.920 b. WA R= ftz None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.131 Total Proposed Modified Loads: 35.38 PASS Total Standard Reference Loads: 46.02 I hereby certify that the plans and specifications covered by Review of the plans and VTOE ST4 this calculation are in compliance with the Florida Energy Code. specification's covered by this calculation indicates compliance O .1R v = p with the Florida Energy Code.' PREPARE BY: Before construction is r�sr completed J DATE: - ` ( this building will be inspected for Section q I hereby certify that this building, as designed, is in compliance compliance with 553.908 Florida Statutes. with the Florida Energy CpD � '►�� OWNER/AGENT- BUILDING OFFICIAL: DATE: - 2? i DATE: Phil MMON ce rram�,,-W&W6 �Z- 4117/201211:19 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: GREEN RESIDENCE FLProp2010 1 Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 830 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address ST. LUCIE COUNTY ST. LUCIE COUNTY, FL, CLIMATE / V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL—ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 2321 18568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 RoomslnBlockl 2321 18568 Yes 3 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio RoomslnBlockl 156 ft 0 2321 ftz _--- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Composition shingles 2514 ftz 0 ftz Medium 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2321 ftz N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) RoomslnBlock1 30 2321 ftz 0.11 Wood 4/17/2012 11:19 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Height Sheathing Framing Solar SpaceFt reasor Below 1 N 2 E 3 S 4 W Exterior Concrete Block - Ext Insfil00mSlnBloc 5.4 78 8 Exterior Concrete Block - Ext lnsiRoomslnBloc 5.4 28 8 Exterior Concrete Block - Ext InS6 oornsInBloc 5.4 78 8 Exterior Concrete Block - Ext InS6t00mSlnBloc 5.4 28 8 624 ft2 0 224 ft' 0 624 ft' 0 224 ft' 0 0 0.75 0 0.75 0 0.75 0 0.75 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 N=>S N=>S Insulated RoomslnBloc None Insulated RoomslnBloc None 0.460000 3 0.4 3 6 8 6 8 20 ft' 20 ft? WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall. Omt ID Frame Panes NFRC U-Factor SHGC Storms Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 N=>S 1 Vinyl N=>S 1 Vinyl N=>S 1 Vinyl E=>W 2 Vinyl S=>N 3 Vinyl W=>E 4 Vinyl Single (Tinted) Yes 0.55 0.3 N Single (Tinted) Yes 0.55 0.3 N Single (Tinted) Yes 0.55 0.3 N Single (Tinted) Yes 0.55 0.3 N Single (Tinted) Yes 0.55 0.3 N Single (Tinted) Yes 1.3 0.64 N 80 ftz 2 ft 0 in 7 ft 0 in 27 ftz 2 ft 0 in 7 ft 0 in 6 ftz 10 ft 0 in 8 ft 0 in 12 ftz 2 ft 0 in 6 ft 0 in 120 ftz 10 ft 0 in 6 ft 0 in 60 ftz 10 ft 0 in 6 ft 0 in HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 HERS 2006 None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 BySpaces Proposed SLA 0.000360 2191.68 120.320 226.280 0.26280 , 7.08214 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 7.7 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 13 47 kBtu/hr 1410 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None RoomslnBlock10.92 40 gal 60 gal 120 deg None 4/17/2012 11:19 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER.SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply — — Return— Air Percent HVAC # V # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 185 ft2 Attic 25 ft2 DSE=0.88 RoomslnBlo0.0 cfm 0.00 % 0.00 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Mar Apr May Jun Jul [X Aug X Sep f X Oct f X Nov f X Dec f X� Jan Heating IX X� Feb IX jXXj Mar X� Apr IX IXXI May X� Jun IX Jul rXI [X� Aug X� Sep XI Oct XI Nov XI DecVenting X Jan X Feb X Mar X Apr X May X Jun Jul X Aug X Sep X Oct X Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4117/201211:19 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: ST. LUCIE COUNTY, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:. gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes"tesigned to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawispaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 4/17/201211:19 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5