HomeMy WebLinkAboutEngineeringa JAMES BUSHOUSE, PE: CONSULTING ENGINEER 1176 SW. 4th COURT. BOCA RATON, FL 33432 (561) 417-3891 1/2 34 St ®� 93 r—%271 ALL WALL PARALLELL TO SNORE LIDS SHALL , 5E 132ANGI13LE WALLS COVERED (PATIO S° STWCO ON SELF -FURRING RIB_METAL LATH ON FELT OVER THE BOTTOM OF TRUSSES W/ 20 STAPLES (MR P4' EMBED INTO ! TRUSS AT EVERY RIB a 4° OTC. TM j (SEE FRC. 2004 SEC. R'103b) (e FBL. 2004 W/ 2006 AMENDMENTS S (TYPICAL AT ALL EXTERN CEILNG) ! I I I JOB NAME: DESCRIPTION: DATE: 4/21/08 RUPP RESIDENCE 4932 WA70SONG WAY FORT PIERCE, FL PERMIT NO. 0803-0271 1. MACHINE ROOM FOR ELEVATOR COMM. NO. 2 SKEET N0. 1 OF 1 JAMES PE log OVAL ENdNEER FLORIDA pwil 1 To: County of Port St Lucie. 2300 Virginia Avenue Ft. Pierce, Fl Plan Review Department AnNam CORPORATION April 09, 2008 Project name: Rupp Res Lot 61 at Watersong, Plan check Permit No. 0803-0271 Contractor G.W. Purucker Dear Sir / Madam; Please find the following items for respond to your. review comments. 1. Provide NOA for Aluminum Bahamas Shutters & Louver in cupola Provide by builder. 2. Attic access panel need to shown on plan Attic access will be min. 22x36 (see sheet A6.2 and AE-2 3. Elevator manufacture specs - Provide by builder - Electrical revise for power li s e sh -I -2 4. Provide Fireplace installation an Provide by builder. 5. Drwaing A53 detail G-1 note overlapping. Reivised see sheet A53. 6. Need product signed and sealed approval affidavits & wind load forms Provided 2 copies each - Respectfull. ;submit 4 Hung V. Nguyen 2312 SW. 10+h Street, Boynton Beach, FI 33426 p. 561445-9135 f. 561-742-3521 Apr 08 QIIB 10:Z1RM HP LHSERJEI FHX p.e- A R 0?,.,. Cods Compliance Qh►bton Review Comments 2M Virglnla Avenue 2-=htlP!l/&1Iudft*.qoykG 72)A8Zl5n Fait: (TT21 46t•25Z2 _. ._...._ _..... Pegs PROPt?RT Y INt�tulel T10N Address: AIM WATERSONG WAY Ownlr(s): CtllyIState ltlp, FORT PIERCE F! 349ag IM��R�PP PatinIt : 2=40D-007MOOri JUrbilk bon: St Lucia Counly Zoning: PUO Lo! t : 81 Illock: APPLICATION INFORMATION Permit Numur. =a-D271 ApptiawAm Type: Master PermD %fibs Activity Type: Niw Other Acti tty: PsrrMt Type: Bull ft Residential (SFR) Stories: 4 Autometic a3prinkier 3ystaet4 0 CONTRACTOR Wffll MA 1�10 ( CGntrator Slane: GARY W. PURUCKER Fax Mumpoi 301-776.WW SusmWes NOW. O W FURLICKER HOME INC Business Addr: -rrM PGA BLVD STE 208 CRY I &At* I Ill PALM BEACH, FL 33411 RZIEWS Alva ,ommENTS Affift" Dint 5tot ow. ggMpIom 0022k— Xsed Add-1110asapnmeet complato 03It5R0(lR Oocwrnnts Wasing tone v late r44ritsmel& 031Z6t2008 1 Commenl • NEED A COPY OF THE RECEIPT FOR PAID UTILITIES FOR WATER AND SEWER (FPUA AND SLCU, TWO AFFERENT AGREEMENTS) - AT TIME OF PICKUP NEED NEW NOC • WILL EXPIRE ON 411WMOO, NEED COPY OF THE VEGETATION REWVAL - NEED TO SIGN THE FLOOD H MO ( F TH PI low t>.3+26/200D 3 Comment W6 NEED 2 SIGNED S LED PRODUCT APPROVAL AFFIDAVITS - NEED 2 SIGNED AND 89AI.ED WINO LOAD FORMS Apr 08 2008 10:21AM HP LRSERJET FAX p.3 r Code Compliance Division Review Comments 2300 VNglnia Avenue Ft. Pierce, FL 3402 Phone: (7?2) 4$2-1553 Fax: (7721462-25?2 http:IlaNuelecapovlce 040=0011 3 COR7MQM FradCounlaMrApw Complete LorleGerstornaler 03128/2008 8312a12008 fl0111ffvd for Pickup Pendtig Plans EXOrMner Review Ineompleto Ed DeGonnaro OdlOi12005 041081204E i Comment PROVIDE NOA FOR ALUMNUtM BAmAMA SHUTTERS AND LOUVERS IN CUPOLA 0410&WM 2 Comment PROVIDE ATTIC ACCESS PER FRC SECTION E07 OUO8t20Da 3 Comment P1tOMDF- ELEVATOR INSTALLATION MANUAL AND ELECTRIC REQUIREMENTS 0410OMM 4 Comment PROVIDE FIREPLACE INSTALLATION MANUAL 04N8/2008 5 Comment DRAWING AS.3, SECTION 0-1 HAS OVERLAPPING NOTES, PLEASE CORRECT 041082008 6 Comment COMMENTS FAXED TO CONTRACTOR 20n7nit RwleM 03127(2008 041031200E Complete LOW GaMaKilu0p Page 2 3ames M. Bushouse, PE Consulting Engineers April 10, 2Q08 St.'Lucie County Building Department 2300 Virginia Avenue Ft. Pierce, Florida Re: Permit Number: 08-03-0271 _ Project Name: Rupp Residence #2 Lot 61 at Watersong Fort Pierce, FL To Whom It May Concern: This letter is to inform you that I am the Design Engineer of Record for the above project. If you have any questions, please contact me at the address below. Sincerely, Jam s D._ Bushouse, P.E. - - Professional Engineer #20311 State' of Florida 1176 S.W. O Court, Boca Raton, Florida 33432 Phone: (561) 417-3891 Fax: (561) 395-8630 bushouse 0 bellsouth.net St. Lucie County Building and Zoning Department 2300,Virginia. Avenue Fort Pierce, FL 34982 772-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the'Building Inspection Office at 462-1553 or 462-2172. roject Name treet Address Permit Number Construction Office Use Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1. Florida Building Code 2004 Edition V- ASCE 7-98 2. Building Design is (check one) Enclosed `V Partially Enclosed Open Building 3. BuildingHeight: e-V1 -�► g 4. Wind Speed Used in Building Design: L4O 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): 6. Average Wind Velocity Pressure on Exterior Faces of Structure _ 33. 5 PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure 3.2- PSF 8. Importance/Use Factor (obtain from Building Code): 9. Loads: Floor_ _! PSF Roof/dead ! � PSF Roof/livePf �. 10. Were Shear Walls Considered for Structure (check one : Yes o No ttach explanation) 11. Is a Continuous Load Path Provided (chV.e Ye 1No, attach explanation) _12. Are Component and Cladding Detail Pr ( ne : Yes � No (if No, attach explanation) 13. Minimum Soil Bearing Pressure: NA& PSF As witnessed by my seal, I hereby certify that the information included with this certification is tru and correct, to the best of my knowledge and belief. _ Name: Certification #: 2Q�j �1 g ere] Design Firm: _ '4mesp�� Date: SLCCDV Form # 020-00 rev. I015105 dmg Prauuct Review AffitiAvit • St Lucie County, Public Works Department Code Compliance Division The following products will be installed in the structure located at 1_1l AMA SONG Building Permit # Owners Name RdM& RV Owner's Address —I 3& J!'1S;RA tv1APr DR, Contractor .&W. %-VG "per Contractor's Address 5606 PGA Bwo Sf1lTP. 208 PAW Product *Product Rated esi Pressures Manufacturer Model Number Method of Attachment Windows * Fill in the rated wind design pressures listed by the manufacturer for each product listed 1st Choice S�D 2 Z - . 74.0 'Lx¢ WERR W "rNAJI-s 2nd Choice OG . W (ro X ¢ Fixed Glass 1st Choice t71. _ 1.6 pW 70 hWVa Ses 1 L S . 2nd Choice w..> Glass (other) Butt Glass Glass Block Tiding Glass Doors 1st Choice r 6 O A$jV6 2nd Choice of 11 5 Swing Type Doors 1st Choice _ " 1�C T", �O ( 't 2nd Choice G►. ��, IV OG. W tAYX �' TitiP 1 Overhead Garage Doors 1st Choice ¢Z —5-Z RAitNCf P_ low� 4uCo Pr. TO GONG 2nd Choice ScPrNSI6N ROI.TSLo l2 le - Roofing Material J , Asphalt/Fiberglass Metal Other W it Shutters Choice 1 have reviewed the above components and cladding, and have approved their use in the structure to provide adequate resistance to the wind loads and forces specified by current c de provisions. Name: Linw6m Signature Design Firm_ Cert. No. 203 Date: y/>/o $ A .C.1 RESIDENTIAL ELEVATORS Elevating your stanaara of awing Builder's Information LLrz 611-' Luxury Lift 950 - Hydraulic Home Elevator QUALITY • SAFETY • DEPENDABILITY • BEAUTY • ENGINEERING EXCELLENCE Residential Elevators, Inc. (REI) is pleased to offer our Luxury Lift hydraulic elevator line with our largest size and payload ever. The Luxury Lift 950 hydraulic elevator has an industry leading 9501b capacity - STANDARDI Benefits: The Luxury Lift 950 residential elevators are built using the same design criteria developed over decades and used in the commercial and industrial elevator market. REI's Luxury Lift 950 gives the lifting capacity normally available only with commercial elevators. Complement the Luxury Lift 950 with your personal choice cab appointments and enjoy commercial elevator features at residential elevator prices. Low maintenance consistent with REI's reputation and demonstrated track record for effective and highly engineered hydraulic elevators with affordable cost and beautiful finish. e Only 96" of clear overhead needed and an 8" recessed pit e Can accommodate hoistway up to 55-112" x 63-1 /2" e Platform size up to 42" x 58-1 /2" CustoM Features To Your Order: REI will custom build many upgrades to your exact specifications including: extra gates, change of cab height, observation glass panels, frame and panel, recessed phone box, keyed hall station, custom interior, custom fixtures, power gates, and much more. STANDARD FEATURES: Free job site survey by one of our trained representatives One (1) year warranty Standard car capacity 950 lb. Provides for up to 28 ft. of travel standard ORIIX Travel speed of 40 ft. per minute Ole Two speed leveling valve 3/4" sturdy cab walls (7ply custom cabinet g d LOatl Custom made cab and interior to your specifI o Automatic emergency -lowering feature Automatic two-way leveling Aluminum anodized scissor gate or accordion style solid gate Standard interior cab color choices: (Unfinished Birch or Oak and Classic White) Solid hardwood handrail Recessed lighting Interior cab emergency light Wall mounted full function phone Meets or exceeds all ANSI A17.1 National Safety Codes for elevator safety. RESIDENTIAL ELEVATORS Elevating your standard of living OPTIONAL SELECTIONS: . Travel over 28' (50'- 0" max.) e Woods er an standard di s StopOv a ca ht cab (6'-8" To 8'-0") • Frame & panel cab e Picture frame cabs (2 or 4 panels) • Observation glass panel inserts • Mirror w/hardwood trim e Recessed phone box • Halogen downlights e ' Keyed hall station e Remote machine room e "Car Here" and "In Use" indicators . Auto homing / auto light timer Protective pads e And more RESIDENTIAL ELEVATORS, INC. Tallahassee, FL 20 Residential Drive, Crawfordville, FL 32327 Ph (850) 926-6022 - Toll Free (800) 832-2004 a Fax (850) 926-5319 www.ResidentialElevators.com e-mail: sales@ResidentialElevators.com February 2004 IDENTIAL Elevating your standmd of living Minimum Requirements for Hydraulic Elevators 24 August 2006 1. 52" x 56" clear inside hoistway dimensions when using an accordion style solid gate. 2 &"ftififtnii oad 3. 96" clear hoistway overhead for 6'-8" cab. 4. 11" minimum return on rail side wall. If this cannot be obtained, contact office for approval. 5. If masonry construction, rail wall needs to be poured 6 Bait side: blacking fob wood frame haisfiways must, be two 2 x 1Y2's sandwiched togettrer„ dcriog: a calljr.ftieenfire'fe�gfh ofttfie°hoist�iia 12° oixc&O a of OK.hers de o;the raiF„alcenterlibe `(Please see rail wall structural drawing.) 7. Any travel distances over 28'-0" will in JLBdard 'alQU, rge arg piston aim travel. (Add approximately one m ery time.) 8. Machine room to be located adjacent to rail wall on first floor. 9. Remote machine rooms to be approved by office. 10. Machine room to be 48" x 48" or large enough to accommodate pump and controller without restricting access, and as per code. 20 Residential Dr., Crawfordville, FL 32327 Toll Free (800) 832-2004 Fax (850) 926-5319 www.ResidentialElevators.com . ES-UNTIAL ELEVATORS Elevating your standard of fiving Work Done by Others Hydraulic Page 2 of 3 Luxury Lift ELEVATOR HOISTWAY: Provide an enclosed finished LEGAL hoistway with INSIDE CLEAN, CLEAR, SQUARE AND PLUMB (including pit) dimensions recommended to be a minimum of 52 inches wide by 57 inches deep (52" X 571 including blocking, which will provide an interior cab dimension of approximately 12 square feet. REI will build to your specifications if smaller than the above, but only to the smallest dimension inside the dean, dear, square and plumb (nduding pit) finished hoistway (plywood walls preferred). Barricades and/or any/all other legal methods required by any jurisdiction to prevent access into shaft shall be required outside each floor landing for the protection of workmen and all other subcontractors and/or occupants until the elevator is installed completely and tumed over to home owner. These devices shall be the sole responsibility of GC. GC TO PROVIDE SOLID CORE HOISTWAY DOORS WITH HINGES LOCATED ON RAILSIDE. (Clearance between hoistway doors and gates AND landing sills): DOOR SIDE WALL TO BE OF 2' X 4' CONSTRUCTION. Regardless of construction type EACH DOOR MUST BE RECESSED TO MEET THRESHOLD REQUIREMENTS AS CONTAINED N THE ANSI A17:1 (37 X 5' SPACING CODE). The distance between the hoistway landing door, in the dosed position, and the elevator gate(s), in the open position, shall not,exceed &inches The distance between the hoistway landrng,door,.in the closed position,_and landing sill. shall nokexcee&3 inches I= �t aR`C�NHaT B OPT ATCOI ►L�UNLESS.tANa(NG DaOE€S' ARE'. IN COMPLIANCE (See Page` 3 ofthls Contract for. further iafcririatibn)", THRESHOLD: Contractor shall provide a threshold from each floor to within 1/2' minimum to 1'n' maximum (ideally 1-1"') of the elevator platform AFTER the elevator has been installed. Doors shall NOT be centered but installed per REI specs to allow proper rail side return measurement. Rail Side return measurement of at least 12 inches is required. Hoistway side of landing door frames shall NOT have casing or door trim that exceeds '/+ thickness. A. IrAtNIMFJAII PIT OF S":.INCEIES-IS REQ IIREE built to withstand 5,1001b maximum load. Minimum W overhead clearance is required for 6'-W cabs (108' for 8'-0' cabs.) ANY TRAVEL DISTANCES over 28'-0' requires a special piston which requires installation during framing stage due to piston length. Contractor to allow REI four (4) weeks notice to order, deliver and install "Hydraulic Jack" prior to sheetrock. _ WOODFRAME HOME BLOCKING REQUIREMENTS: Four (2 sets of 2 ea.) — 2' X 12' yellow pine studs running vertically the entire length of the hoistway 12' on center on either side of rail wall centerline (centerline of rail wall must be minimum of 28" off inside front wall), 2' x 12' to be face nailed, glued and edged with 2' x V for structural integrity. The yellow pine boards shall all be fastened to the wall supports with 3/8' by 2-1/2' lag bolts to support elevator rail system. To insure adequate supports in w 11 for guide rail fastenings these should not exceed ten (10) vertical feet and meet all pertinent building codes (see blodd i d I pi e 3). CONCRETE BLOCK HOME OR HOISTWAY: All dimensions shall re n the ire INS ,CLEAR, SQUARE AND si PLUMB hoistway. Rail sidewall blocks shall be filled soli nc a the a re le n of h•' ay. O (1) 4' Knockout shall be provided between ho➢stway and machine room. All patchi , pa n gr ag r�eq i e la on is the responsibility of GC. MACHINE ROOM: An elevator machine room all be vid ntractor. UNLESS OTHERWISE SPECIFIED, MACHINE ROOM IS ASSUMED TO BE A LOWEST LEVEL ADJAC NT TO ELEVATOR. This area shall be a minimum size of 4' X 4' and to meet all electrical codes. Contractor/Owner is responsible for notifying REI if Machine Room is located within a Flood Zone and contractor is responsible for building platform or room above Flood Zone per REI specifications. If machinery is located in attic, a deck must be built to support loads imposed by unit (Contact REI for Details) height and accessibility for service and installation should be provided including catwalk to deck area, settle hole and attic ladder. Attic not recommended for hydraulic installations. If machine room is remote (not rail side adjacent) Contractor is responsible for coordinating the timely installation of 314' seamless schedule 80 black pipe. REI will install, but we must have ample time and access. ELECTRICAL: breaker (both i and?'standard t10;:Woltr 115 Amp single pole circuit and telephone line shall all be located in machine _ : ,. ,._.. ....,,,.. 240V-30fK1171pDCSCONIEC C/T#J~122 WI H II!kTERLOCtCKIT (CATEIKt)1I)kPL�fJS 2`EACH"250V`RK5 FUSE, AND:;SINGLE G .... ,.. POLE.SQUARE.'D' 1,1OV=1.5A. DISCONNECT: Explanation: The 220V feed should have a black, red, white and ground wire coming to the machine room. All electrical contractors will have full knowledge of this requirement Simply insure they are aware of the requirement. Black and red are powered with 110V each totaling 220V. White is neutral to feed low voltage transformer with 110V ground to ground standard. (See RE➢ electrical requirements sheet.) General Contractor andfor Owner shall Indemnify and hold REI harmless for all claims subject to this "York Done by Others" - ANY WORK DONE BY OTHERS HEREIN NOT FULLY COMPLETE PRIOR TO TIME OF INSTALLATION SHALL RESULT IN A REMOBILIZATION FEE OF 5750. NOTE: INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE K, Authorized Signature Print Name Date Home Elevator - Pre Installation Checklist Com leted Item Yes 1 No Date Notes 1 Pit Depth W min/35" max) 2 Hoistway measurements per spec's. 3 Legal machine room (LL hydraulic) 4 Access door per spec's (Horizon) 5 Dedicated 220V/30A circuit 10-3 wire to machine room 6 Dedicated 110V/20A circuit 12-2 wire to machine room 7 Phone line w/ 10' pigtail to machine room 8 Rail side blocking complete 9 Door retums ' per spec's 10 Door entry comply w/ 3x5 rule 11 Overhead measurement per s ec's 12 Electrical covered by sheet rock 200V / 110V / Phone line 13 Door jamb installed & comply w/ 3x5 code 14 Solid core door installed 15 1/4" thick hoistway door casingtoo 16 Proper 220V disconnect per spec's 17 Proper 110V disconnect per --spec's 18 Door hardware installed 19 Temp. power to machine room 20 Permanent power on home OVERHEAD CLEARANCE W MIN. FOR 6'-W CAB HEIGHT 108' MIN. FOR 8'-0" CAB HEIGHT OF LESS THAN W IS AVAILABLE, CONSULT R.E.I.) LANDING DOORS 2'-8" OR T-V W BY 6'-W OR 8'-0" H SOLID CORE RECOMMENDED (BY G.C.) TOP FLOOI LANDING LINE ELEVATOR SHAFT WALLS WITH PLYWOOD (PREFERRED) OR DRYWALL INSIDE AND OUT CHECK LOCAL CODE REQUIREMENTS FOR THICKNESS ELEVATOR RAILS & BRACKETS BY R.E.I. AND INSTALLED BY R.E.I. TERMINATED IN ELEVATOR = CONTROLLER (BY G.C.) LIGHT SWITCH C7 (BY G.C. Lu id ELEVATOR O 2 CONTROLLER LLI Z r ~ I CAR uGHrwG �a r 1 FUSED DISCONNECT HALL PUSH SWITCH (BY G.C.) BUTTON I =EMAIN LINE z STATION BY I FUSED DISCONNECTz SWITCH (BY G.C.) R.E.I. (TYP.) i NIT BOTTOM FLOOR FLANDI PIT DEPTH 8' MIN. , ,�J 21-6' MIN. ACCESS ° ° 2' - 3 QG OU DOOR (BY G.C.) BY (G.C.) ELEVATOR PIT MINIMUM 4' THICK REINFORCED CONCRETE SLAB TYPICAL ELEVATION AND LAYOUT (ADJACENT MACHINE ROOM) Elevating your standard of living 12'-0" MAXIMUM FOR VERTICAL SUPPORTS PLYWOOD (PREFERRED) OR DRYWALL VERTICAL 2 x 12'S —< AND 2 x 4'S BY GENERAL CONTRACTOR 12'-0' MAXIMUM FOR VERTICAL SUPPORTS 8' PIT DEPTH MINIMUM MINIMUM 4" THICK REINFORCED CONCRETE SLAB HYDRAULIC HOISTWAY / PIT DETAILS LEVATORS 96" MIN. FOR 6'-8' CAB HEIGHT 108" MIN. FOR 8'-0" CAB HEIGHT TOP FLOOR LANDING LANDING DOORS (BY G.C.) BOTTOM FLOOR LANDING ELEVATOR PIT NOTE: ALL WORK ABOVE TO BE BY GENERAL CONTRACTOR Elevating your standard of living 27" 12n 12■ REAR WALL SECTION A - A i ITOP OF HOISTWAY I(4)2x4 OF HM PIT Vp FRONT WALL (4)2x12xHEIGHT I OF HOISTWAY JALL INE OF 'PORT OFF JALL CONTRACTOR RESPONSIBILITY ELEVATION TO ENSURE ADEQUATE SUPPORTS IN WALL .FOR GUIDE RAIL FASTENINGS, NOT TO EXCEED 12'-0" VERTICAL INTERVALS EIevating your standard of living MIN_ on CONTROLLER `20" HIGH (4'- 0" ABOVE FLOOR TO THE BOTTOM OF THE CONTROLLER DISCONNECT STANDARD MACHINE ROOM LAYOUT SCALE - 1/2' -1' NOTE: ALL DIMENSIONS ARE APPROXIMATE DPAM I CHECKED: DAB G.P. I M.C. - 01/08/04 1 NEW DRAWING NOTES: 0 220 V, 2 POLE, SINGLE PHASE, FUSED DISCONNECT WITH 20 AMP RK 5 FUSES (PER NEC 2002 - BY OTHERS.) ALSO, PROVIDE 120 V., FUSED DISONNECT OR 15 AMP CIRCUIT BREAKER FOR CAB LIGHTS (PER NEC 2002 - BY OTHERS.) 0 PROVIDE A PHONE LINE TO THE ELEVATOR MACHINE ROOM AND INSTALL IN A 4" z 4" BOX WITH COVER ( 8' -19 TAIL MIN.) (BY OTHERS.) �O3 LIGHT SWITCH TO BE INSTALLED ADJACENT TO LOCK SIDE OF THE DOOR (BY OTHERS.) 4 MACHINE ROOM DOOR TO BE A MINIMUM OF 30" WIDE. MACHINE ROOM DOORSJO SWING OUTWARD (BY OTHERS.) -O5 A GFI RECEPTACLE IS TO BE PROVIDED IN THE ELEVATOR MACHINE ROOM / SPACE (PER NEC 2002 - BY OTHERS.) © 5'-W MIN. HEADROOM RE9D FOR ELEVATED PLATFORM/ STANDS. 20 RESIDENTIAL DRIVE RESIDENTIAL CRAWFORDVILLE, FL 32327 ELEVATORS ResidentialElevators.com Elevating your standard of living 1-800.832-2004 We, DMAWMD NUMBER SPECIFICATIONS HYD M01 _ MIN. ALTERNATE MACHINE ROOM LAYOUT SCALE - V- f NOTE: ALL DIMENSIONS ARE APPROXIMATE DNnvm I cri—: Dare REVMM G.P. I M.C. 1 01IM04 1 NEW DRAWING NOTES: Adr H ) 220 V, 2 POLE, SINGLE PHASE, FUSED DISCONNECT WITH 20 AMP RK 5 FUSES (PER NEC 2002 - BY OTHERS.) ALSO, PROVIDE 120 V., FUSED DISONNECT OR 15 AMP CIRCUIT BREAKER FOR CAB LIGHTS (PER NEC 2002 - BY OTHERS.) PROVIDE A PHONE LINE TO THE ELEVATOR MACHINE ROOM Vc . ND INSTALL IN A 4" x V BOX WITH COVER ( 8' -10' TAIL MIN.) Y OTHERS.) GHT SWITCH TO BE INSTALLED ADJACENT TO LOCK SIDE OF THE DOOR (BY OTHERS.) ECT CHINE ROOM DOOR TO BE A MINIMUM OF 30" WIDE OTHERS.) FI RECEPTACLE IS TO BE PROVIDED IN THE ELEVATOR V6ACHINE ROOM / SPACE (PER NEC 2002 - BY OTHERS.) 5'-0" MIN. HEADROOM REQ'D FOR ELEVATED PLATFORM/ STANDS. 70 CONTROLLER IS WALL MOUNTED ABOVE PUMPING UNIT. DIMENSIONS 20" W x 20" H x 6" D WITH BOTTOM OF CONTROLLER 4' - 0" ABOVE FLOOR (TYPICALLY.) ® PUMPING UNIT DIMENSIONS: 14-1/4" D x 30" L x 34" H 20 RESIDENTIAL DRIVE RESIDENTIAL CRAWFORDVILLE, FL 32327 ELEVATORSResidentialElevators.com Elevating your standard of living 1-800-832-2004 NAME: DMMO NUMBER SPECIFICATIONS HYD M02 Electrical Requirements for Elevator Machinery Sr)ace ft G.C. 10wnerlOthar) Programmable Logic Controller Elevator Cab . . . . . . . . ..... 27 Conductor 71raveling Cable Hydraulic Application Owner / GC House Phone Line (10'pigtail) W AM Al W -C R E Elevator Controller U Cab Light Disconnect Room Light Switch ftchlne Room Main Disconnect 14011MW --Awl Hydraulic Power Unit GFI Outlet Residential Elevators, Inc. 20 Residential Drive, Crawfordville, FL 32327 r3 Main Disconnect 230 VAC - 30 Amp Light Disconnect 115VAC-15Amp S u p IF W p V, 00 d R E Horizon MRL Application Elevator O Au)dllary contacts - Reqd with Controller & Hol@MW emergency lowering feature Room Light and Switch 11) Handle lockable in -OFF" position Cab Light Disconnect I (by Code) Main Disc6nnect O (2) 230 V - 30 Amp RK5 fuses GFI Outlet Toll Free 1-800-832-2004 February 2008 contact: sales@ResidentialElevators.com Residential Elevators.com Elevator Electrical Requirements By General Contractor / Owner Each home elevator requires five (5) items from your Electrician and Telecommunications Contractor(s). They are as follows: 1. One (1) 120V 15 Amp Fused Disconnect or Circuit Breaker, as outlined, for Cab Lighting (see below.) 2.One (1) 230V 30 Amp Fused Disconnect, as outlined, belown Power supply (see below.) 3.One (1) GFI Outlet. 4. One (1) Light Fixture with wall switch. 5. One (1) Phone Line with 10' pigtail .� Recommended Mar Square D - 230V Disconnect Model # H221 N - 240V - 30 Amp with Interlock Kit-EIK031 Aux Contacts (Normally Opened/Normally Closed) Plus two each - 250V, 30 Amp, RK5 Fuses -120V 15Amp Fused Disconnect or Circuit Breaker Siemens - 230V Disconnect Model # HF221 N - 240V - 30 Amp with Interlock Kit-HA161234 Aux Contacts (Normally Opened/Normally Closed) Plus two each 250V, 30 Amp, RK5 Fuses -120V 15Amp Fused Disconnect or Circuit Breaker Model # TH3221 - 240V - 30 Amp with Interlock Kit-THAUX21 D Aux contacts (Normally p ed/Normally Closed) Plus 250V, 30 Amp, RK5 Fuses -120V 15Am used Disconnect or Circuit Breaker Cutler Amer - 230V Di o ec Model # DH221 NGK - 240V - 30 Amp with Interloc Kit-DS200EK1 Aux contacts (Normally Opened/Normally Closed) Plus two each 250V, 30 Amp, RK5 Fuses -120V 15Amp Fused Disconnect or Circuit Breaker PLEASE BE ADVISED THAT POWER ON THE 230V LINE MUST BE A 10-3 WIRE WITH A GROUND AND INSURE THERE IS A DEDICATED NEUTRAL TO THE UNIT. Explanation: The 230V feed should have a black, red, white and ground wire coming to the machine room. All electrical contractors will have full knowledge of this requirement. Simply insure they are aware of the requirement Black and red are powered with 115V, each totaling 230V. White is neutral. Ground to ground standard. Also, standard telephone line should be pulled to machine room with approximately ten feet extra length inside machine room. If further explanation or clarfication is needed, please contact your local sales representative. February 2008 Residential Elevators, Inc. Toll Free 1-800-832-2004 20 Residential Drive, Crawfordville, FL 32327 contact: sales@ResidentialElevators.com ResidentialElevators.com