HomeMy WebLinkAboutInsulation - Installation Certificate8-10-27 13:16 772.466.0609 �. Leed-FTP P 2/3 INSULATION INSTALLATION CE01FICATF, bfS01 - D Abe% TO: Purucker t.O'r23' 13UU.CK; SECTION; Watersot jo lM: 45651 JOB NAME; JOB ADDRESS: 4932 Watersono Way, Ft Pierce 1�1 7 Ter DGC6 _ The undersigned hereby certifies that insulation has begirt`installed at the above described property as follows: L Vxterior CBS walls have been insulated with ............................Check one ( ) Spray on cellulose to a thickness of NIA incites, which thickness, according to the () piberghtss blankets manufacturer, Fi-Foil (f) Aluminum Foil Density NIA will yield an "R" value: of 41 () Other Exterior Frame walls have been insulated with ............................Check one ( ) Spray on cellulose to a thickness of 6.25 inches, which thickness, according to the (4 Fiberglass blankets manufacturer, Knauf ( )Aluminum Foil Density N/A will yield an "R" value of 19 ( ) Other ?. Ceilings Main have been insulated with ............... ....Check one V) Fiberglass blankets to a thickncss of 10.0 inches, which thickness, according to'the' (} Fiberglass loose till nlartulaeturcr, Knauf O Aluminum Foil Density N/A will yield an "R" value of 30 O Other Ccihdosl: SAB Ceilings. have been insulated with .........................Check one ( ) Fiberglass blankels to a thickness of inches, which thickness, according to the ( ) Fiberglass loose fill manuftaaarcr. ( )Aluminum Foil Density N/A will yield an "R" v4luc of ( ) Other Cellulose SAB 3. Interior knee walls have been insulated with.................................('heck one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Polyurethane manufacturer, ( ) Spray on cellulose Density NIA will yield an "R" value of ( ) Other 4. Garage Partition wails of conditioned living areas have heen insulated with................................................................................Check one (t/) Fiberglass blankets to a thickness of 6.25 inches, which thickness, according to the () Spray on cellulose manufacturer, Knauf ' • () Polyurethane Density NIA will yield an "R" value of 19 () Other %Al Il; I'( FAMiLY RF S)DENTIAL CONSTRUCTION ONI,Y: The common (party) walls separating different tenants shall be insulated as follows - Fratne/Metal stud walls R-1 I (Min.); CBS or Concrete walls R-3 (Min.); by L•;nergy Code requirements. See Fnergy Code Rev. i/87, paragraph 9()3,2(b), on page 9-17. latest edition. 'These "minimums levels of insulation" are not included in the Energy Calculations, but shall be installed in the field. NOTE,.; Densities of sprayed on, loose fill, or any other composul-on site instil shall be the P.C.F. (1151tt3) average ol'thrce (3) "DRY SAMPLES" ofactual loss tt� I,EED F'1RI?PROOFING & iNSULATION. INC. Insulation Contractor Insulation Contractor Signature Ft. Pierce - 02-11904 06/16/08 insulation Contractor's (-'C# Date of Certification Builder's Name - Builder's C'C4 Notary Public �- ............................................ STEPHANIE GARWOOD �"uYwh Gomm# DD0806279 . 3 . 2�r. Expires 8/23/2012 M'''�prN�7�7l!'nn��ry N..aR............ Wd f I.- Ann., Im .i.u.....u-a