HomeMy WebLinkAboutPermit 2105-0411Insulation Installation CertificateINSULATION INSTALLATION CERTIFICATE TO: AEM Associates Jos#: 121766 JOB NAME: Marsilia Res LOT BLOCK: SECTION: �mI .IOB ADDRESS: 13506 Coco Plum Court, Stuart Florida 322W 3 ypf© The undersigned hereby certifies that insulation has been installed at the above described property as follows: I. Exterior CBS walls have been insulated with ............................Check one (} Spray on cellulose to a thickness of NIA inches, which thickness, according to the (} Fiberglass blankets manufacturer, FFoil (X) Aluminum Foil Density NIA will yield an "R" value of4.1 ( ) Rigid Exterior Frame walls have been insulated with ............................Check one ( ) Spray on cellulose to a thickness of inches, which thickness, according to the ( ) Fiberglass blankets manufacturer, ( )Aluminum Foil Density N/A will yield an "R" value of ( ) Other Spray Foam 2. Main Ceilings have been insulated with .........................Check one { } Fiberglass blankets to a thickness of 5.25 inches, which thickness, according to the (} Fiberglass loose fill manufacturer, SES Sucraseal { ) Density NIA will yield an "R" value of20 SjJray foam Cedings Cathedral have been insulated with .........................Check one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Fiberglass loose fill manufacturer, () Aluminum Foil Density NIA will yield an "R" value of () Other Certuiose 3. Interior knee walls have been insulated with.................................Check one ( ) Fiberglass blankets to a thickness of 5.25 inches, which thickness, according to the ( ) Polyurethane manufacturer, SES Sucraseal ( )Spray on cellulose Density NIA will yield an "R" value of20 O0 Other Spray Foam 4. Garage partition walls of conditioned living areas have been insulated with................................................................................Check one ( ) Fiberglass blankets to a thickness of inches, which thickness, according to the ( ) Spray on cellulose manufacturer, ( ) Polyurethane Density NIA will yield an "R" value of ( ) Other Aluminum Foil MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating different tenants shall be insulated as follows - Frame/Metal stud walls R-11 (Min.); CBS or Concrete walls R-3 (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9-17, latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall be installed in the field. NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F. (Ib/#t3) average of three (3) "DRY SAMPLES" of actual installation. t(� E0 -fl t-,OV-lSQS LLQ - Insulation Contractor Insulation Contractor Signature MCIN6231 l /31 /2022 Insulation Contractor's CC# Date of Certification Builder's Name - Builder's CC# NE.LY L YOUNQ -•`�4-1 \scary >�'o!'�c-;x:r o`r!crlda Fc"ce.".:bra•ier tix:.ra!'`crz^. ASS�-