HomeMy WebLinkAboutPRESSURES PARADISE EXTERIORS
"Building Our Quality Reputation
One Customer At A Time"
SCC131150472
Property Information Building information
Owner: CHARLES &KIMBERLY ROGERS Wind Zone: 170 MPH.
Address: 290 SUNRISE DR Exposure Category: C
FORT PIERCE,FL 34945 Minimum Building Dimension: 25 ft.
Mean Roof Height: 12 ft.
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number ZoneJ Width(in) IF Height(in) Elevation($) Pressure(psl) Pressure(psfl
I End 36 48 7 37.3 -49.7
2 Int 36 48 7 37.3 -40.6
3 Int 51 61 7 35.9 -39.1
5 End 31 80 7 36.5 -47.9
6 End 31 80 7 36.5 -47.9
7 End 17 37 7 37.8 -50.6
IntW 35 37 7 37.8 -4I.0
9 Int 35 49 7 37.4 -40.6
i
i
Prepared in accordance with:ASCE 7-16,Chapter 30. Wind Loads-Components and Cladding. 7th Edition(2020)Florida Building Code.
Page 1 of 1