Loading...
HomeMy WebLinkAboutAPPROVED FL_1 Snap 26 Ga_12251/7/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCe7ws15artybuwV1hNBC%2bDmD2tyTc8fqfw%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL30304-R1 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Drexel Metals, Inc. Address/Phone/Email 204 Railroad Drive Ivyland, PA 18974 (502) 303-1511 jshumate@drexmet.com Authorized Signature Jason Shumate jshumate@drexmet.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Architectural Testing, Inc., an Intertek Company Quality Assurance Contract Expiration Date 12/31/2025 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL30304_R1_COI_DRX19002.1 2020 FBC Eval NonHVHZ Metal Roofing final.pdf Referenced Standard and Year (of Standard)Standard Year ASTM B 117 2016 ASTM G 155 2013 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By 1/7/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqvH%2bffZfjpUCe7ws15artybuwV1hNBC%2bDmD2tyTc8fqfw%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/09/2020 Date Validated 08/14/2020 Date Pending FBC Approval 08/26/2020 Date Approved 10/13/2020 Summary of Products FL #Model, Number or Name Description 30304.1 HVHZ Metal Roofing Non-structural metal roof panels for use inside the HVHZ Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +0/-161 Other: See evaluation report for limits of use. Installation Instructions FL30304_R1_II_DRX19003.1 2020 FBC Eval HVHZ Metal Roofing final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL30304_R1_AE_DRX19003.1 2020 FBC Eval HVHZ Metal Roofing final.pdf Created by Independent Third Party: Yes 30304.2 non-HVHZ Metal Roofing Non-structural metal roof panels for use outside the HVHZ Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-161 Other: See evaluation report for limits of use. Installation Instructions FL30304_R1_II_DRX19002.1 2020 FBC Eval NonHVHZ Metal Roofing final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL30304_R1_AE_DRX19002.1 2020 FBC Eval NonHVHZ Metal Roofing final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 1 of 6 Page 1 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: DREXEL METALS, INC. Issued August 9, 2020 1234 Gardiner Lane Louisville, KY 40213 (502) 716-7143 www.drexmet.com Manufacturing: Port St. Lucie, FL Quality Assurance: Architectural Testing, Inc., An Intertek Company (QUA1844) SCOPE Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing (TST1558) D9330.03-450-18 TAS 125 2003 Architectural Testing (TST1558) C8008.01-450-18 TAS 125 2003 Architectural Testing (TST1558) C8009.01-450-18 TAS 125 2003 Architectural Testing (TST1558) B3862.01-450-18 TAS 125 2003 Architectural Testing (TST1558) D0841.01-450-18 TAS 125 2003 Architectural Testing (TST1558) B8437.02-450-18 TAS 125 2003 Architectural Testing (TST1558) B8437.01-450-18 TAS 125 2003 Architectural Testing (TST1558) B8438.02-450-18 TAS 125 2003 Architectural Testing, Inc (an Intertek Company) (TST1527) F8542.01-450-44 UL 580 UL 1897 2006 2012 Architectural Testing, Inc (an Intertek Company) (TST1527) G1899.01-450-18 UL 580 UL 1897 2006 2012 Architectural Testing, Inc (an Intertek Company) (TST1527) F0755.01-450-18 TAS 125 2003 Architectural Testing, Inc (an Intertek Company) (TST1527) F9156.01-450-18 TAS 125 2003 Architectural Testing, Inc (an Intertek Company) (TST1527) F9156.02-450-18 TAS 125 2003 Architectural Testing, Inc (an Intertek Company) (TST1527) 0412-1012-06 TAS 125 2003 Architectural Testing (TST1558) C6413.02-450-18 TAS 125 2003 Architectural Testing (TST1558) D6207-01-450-18 TAS 125 2003 Architectural Testing (TST1558) 0412-0621-07 TAS 125 2003 Architectural Testing (TST1558) C6413.01-450-18 TAS 125 2003 Force Engineering & Testing (TST5328) 72-019T0T-07 UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 72-0314T-06A-C UL 580 UL 1897 2006 2012 Force Engineering & Testing (TST5328) 72-0313T-06A-C UL 580 UL 1897 2006 2012 Hurricane Test Laboratory (TST1527) 0412-1203.07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0412-1017-05 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0412-01012-06 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0412-0305-07 TAS 125 2003 Hurricane Test Laboratory (TST1527) 0412-0306-06 TAS 125 2003 UL LLC (TST9628) 02NK11243 UL 580 UL 1897 2006 2012 UL LLC (TST9628) 03NB13142 UL 580 UL 1897 2006 2012 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 2 of 6 Page 2 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing Non-HVHZ PRODUCT DESCRIPTION 1.5” Mechanical Lock Profile: 1.5-inch mechanical seam; Max.20-inch coverage Description: Non-structural, min. 180° mechanical lock standing seam roof panel; Material: Min.16 oz/ft2 ASTM B370 copper; Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (F y = min. 50 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 24 ksi); Shall conform with FBC Section 1507.4.3 1.5” Nail Strip Profile: 1.5-inch snap lock seam; Max.15.5-inch coverage Description: Non-structural, snap lock standing seam roof panel; slotted nail strip; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 PBR and Econ Line PBR Profile: ¾-inch rib; Max. 36-inch coverage Description: Non-structural, through fastened roof panel Material: Min. 26ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 (Fy = min. 40 ksi); Shall conform with FBC Section 1507.4.3 5-V-Crimp Profile: ⅜-inch ribs; Min. 20.5-inch, Max. 24-inch coverage Description: Non-structural, through fastened roof panel Material: Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 23 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 3 of 6 Page 3 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing Non-HVHZ PAC-150 Profile: 1.5-inch mechanical seam; Max.20-inch coverage Description: Non-structural, min. 90° mechanical lock standing seam roof panel; Material: Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 22 ksi); Shall conform with FBC Section 1507.4.3 Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy = min. 55 ksi); Shall conform with FBC Section 1507.4.3 Snap-Clad Profile: 1.75-inch snap lock seam; Max. 18-inch coverage Description: Non-structural, snap lock standing seam roof panel; Material: Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 25 ksi); Shall conform with FBC Section 1507.4.3 Tite-Loc Plus Profile: 2-inch mechanical seam; Max.18-inch coverage Description: Non-structural, min. 180° mechanical lock standing seam roof panel; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (F y = min. 60 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 20 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 4 of 6 Page 4 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing Non-HVHZ Econo Line 1” Clipless Profile: 1-inch snap lock seam; Max.16-inch coverage Description: Non-structural, snap lock standing seam roof panel; slotted nail strip; Material: Min. 26 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (F y = min. 40 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 24 ksi); Shall conform with FBC Section 1507.4.3 Jacksonville Beach Series 1.5” Clipless Profile: 1.5-inch snap lock seam; Max.19-inch coverage Description: Non-structural, snap lock standing seam roof panel; slotted nail strip; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (F y = min. 50 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 21 ksi); Shall conform with FBC Section 1507.4.3 Miami Series 1.75 Snap Lock Profile: 1.75-inch snap lock seam; Max. 18-inch coverage Description: Non-structural, snap lock standing seam roof panel; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 24 ksi); Shall conform with FBC Section 1507.4.3 Palm Beach Series 1.5 Mechanical Seam Profile: 1.5-inch mechanical seam; Max.20-inch coverage Description: Non-structural, min. 90° mechanical lock standing seam roof panel; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 Min. 0.032-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 24 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 5 of 6 Page 5 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing Non-HVHZ Key West Series 5-V Crimp Profile: ½-inch ribs; Max. 24-inch coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (F y = min. 50 ksi); Shall conform with FBC Section 1507.4.3 Stuart Line Series 1” Nail Strip Profile: 1-inch snap lock seam; Max.16-inch coverage Description: Non-structural, snap lock standing seam roof panel; slotted nail strip; Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 6 of 6 Page 6 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing Non-HVHZ LIMITATIONS 1.This report is not for use in the HVHZ. 2.Fire classification is not within the scope of this evaluation. 3.The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4.Roof slope shall be in accordance with FBC Section 1507.4.2. 5.Reroofing shall be in accordance with FBC Section 1511. 6.Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7.All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1)APPENDIX A – Installation (2 pages) 2)APPENDIX B – Approved Roof Systems (8 pages) 3)APPENDIX C – Design Wind Loads (4 pages) 2020.08.09 15:13:43 -04'00' A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 1 of 2 Page 1 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #9-15 HWH wood screw with sealing washer Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion resistant in accordance with FBC section 1507.4.4. #10 HWH wood screw with sealing washer #10 PH wood screw #10-11 Eclipse Head wood screw with sealing washer #10-13 PH wood screw #12-11 PH wood screw #14 WoodZAC® HWH screws #14-13 TH wood screw #14 PH self-drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be corrosion resistant in accordance with FBC section 1507.4.4. Clips 1500SC 1.5-inch Sliding Clip 26 ga. top with 22 ga. base galvanized steel, in-seam clip 24 ga. PAC-150 Clip 24 ga. galvanized or stainless steel in-seam clip 20 ga. Snap-Clad Clip 20 ga. galvanized or stainless steel in-seam clip 20 ga. Snap-Clad Continuous Clip 20 ga. galvanized or stainless steel in-seam clip A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 2 of 2 Page 2 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX A Component Product Installation Detail Clips Tite-Loc Plus Clip 18 ga. base/22 ga. tab galvanized or stainless steel in-seam clip Miami Series 1.75 Snap Lock Clip 0.050-inch galvanized steel in-seam clip Palm Beach Series 1.5 Mechanical Seam Clip 24 ga. galvanized steel in-seam clips Sealants Bostik Chem Calk 915 Shall be applied in ⅛-inch wide continuous beads along the seam Bostik 70-05A A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 1 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. The panel thicknesses stated in the tables below are the minimum thicknesses required. 6. Steel Deck shall be designed by others in accordance with FBC requiremen ts and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR) conforming to ANSI/SDI-RD1.0 & FBC. 7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood sheathing at maximum 24-inch span. Roof System Numbers and Definitions 1.5ML-W# 1.5 Mechanical Lock over Wood Deck (New or Existing) 1.5NS-W# 1.5 Nail Strip over WoodDeck (New or Existing) PBR-W# PBR or Econo Line PBR over Wood Deck (New or Existing) 5VC-W# 5-V-Crimp over Wood Deck (New or Existing) PC150-W# PAC-150 over Wood Deck (new or Existing) SC-W# Snap-Clad over Wood Deck (New or Existing) TLP-W# Tite-Loc Plus over Wood Deck (New or Existing) TLP-S# Tite-Loc Plus over Steel Deck (New or Existing) EL1C-W# Econo Line 1” Clipless over Wood Deck (New or Existing) J1.5C-W# Johnsonville Beach Series 1.5” Clipless over Wood Deck (New or Existing) M1.75-W# Miami Series 1.75 Snap Lock over Wood Deck (New or Existing) P1.5M-W# Palm Beach Series 1.5 Mechanical Seam over Wood Deck (New or Existing) K5VC-W# Key West Series 5-V Crimp over Wood Deck (New or Existing) S1NS-W# Stuart Line Series 1” Nail Strip over Wood Deck (New or Existing) Approved Systems for 1.5 Mechanical Lock over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 1.5ML-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. 1.5 Mechanical Lock Max. 16-inch wide 1500SC 1.5-inch Sliding Clip with two (2) #12-11 PH wood screws spaced 24-inch o.c. -59.75 1.5ML-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. 1.5 Mechanical Lock Max. 16-inch wide 1500SC 1.5-inch Sliding Clip with two (2) #12-11 PH wood screws spaced 6-inch o.c. -123.5 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 2 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for 1.5 Nail Strip over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 1.5NS-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. 1.5 Nail Strip Max. 15.5-inch wide One (1) #12-11 PH wood screws spaced 11-inch o.c. along the nail strip -78.5 Approved Systems for PBR or Econo Line PBR over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) PBR-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga. PBR Max. 36-inch wide One (1) #9-15 HWH wood screw with sealing washer placed 1.5-inches from each side of panel lap and one (1) #9-15 HWH wood screw and sealing washer placed 1.5-inches to one side of the each intermediate rib (5 fasteners per panel; 6”-9”-9”-9”-3” pattern); Fastener rows spaced 24-inch o.c. -76.75 Approved Systems for 5-V-Crimp over Wood Deck (New or Existing) – Install in compliance with PAC Contractors Association’s Installation Details System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 5VC-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al 5-V-Crimp Max. 24-inch wide One (1) #10 HWH wood screw with sealing washer placed through the apex of the inside rib at the panel lap; Fastener rows spaced 16-inch o.c. -74.75 5VC-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al 5-V-Crimp Max. 24-inch wide One (1) #10 HWH wood screw with sealing washer placed through the apex of the inside rib at the panel lap; Fastener rows spaced 8-inch o.c. -176 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 3 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for PAC-150 over Wood Deck (New or Existing) – Install in compliance with PAC Contractors Association’s Installation Details System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) PC150-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al PAC-150 Max. 20-inch wide 90° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -69.25 PC150-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al PAC-150 Max. 20-inch wide 90° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -69.25 PC150-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al PAC-150 Max. 20-inch wide 90° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -99.25 PC150-W4 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. PAC-150 Max. 20-inch wide 90° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -114.25 PC150-W5 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. PAC-150 Max. 20-inch wide 180° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 12-inch o.c. -136.75 PC150-W6 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al PAC-150 Max. 20-inch wide 180° seam 24 ga. PAC-150 Clip with two (2) #10 PH wood screws spaced 12-inch o.c. -166.75 Approved Systems for Snap-Clad over Wood Deck (New or Existing) – Install in compliance with PAC Contractors Association’s Installation Details System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) SC-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Snap-Clad Max. 18-inch wide 24 ga. Snap-Clad Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -86 SC-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Snap-Clad Max. 18-inch wide 24 ga. Snap-Clad Continuous Clip with eight (8) #10 PH wood screws per clip installed end-to-end to form a continuous clip along the seam -151.75 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 4 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for Tite-Loc Plus over Wood Deck (New or Existing) – Install in compliance with PAC Contractors Association’s Installation Details System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) TLP-W1 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -106.75 TLP-W2 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -121.75 TLP-W3 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -174.25 TLP-W4 Min. 19/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -196.75 Approved Systems for Tite-Loc Plus over Steel Deck (New or Existing) – Install in compliance with PAC Contractors Association’s Installation Details System No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP (psf) TLP-S1 Min. 22 ga. steel deck As required Min. ¾-inch Approved polyisocyanurate insulation board As required per FBC 24 ga. Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #14 PH self-drilling screws spaced 24-inch o.c. -106.75 TLP-S2 Min. 22 ga. steel deck As required Min. ¾-inch Approved polyisocyanurate insulation board As required per FBC 24 ga. Tite-Loc Plus Max. 18-inch wide Tite-Loc Plus Clip with two (2) #14 PH self-drilling screws spaced 24-inch o.c. -196.75 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 5 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for Econo Line 1” Clipless over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) EL1C-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga, Econo Line 1” Clipless Max. 16-inch coverage One (1) #10 PH wood screws spaced 6-inch o.c. along the nail strip -71 EL1C-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Econo Line 1” Clipless Max. 16-inch coverage One (1) #10 PH wood screws spaced 6-inch o.c. along the nail strip; Bostik 70-05A applied to both sides of the male rib prior to seam engagement; -78.5 Approved Systems for Jacksonville Beach Series 1.5” Clipless over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) J1.5C-W1 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC .032 Al Jacksonville Beach Series 1.5” Clipless Max. 19-inch coverage One (1) #10 PH wood screws spaced 6-inch o.c. along the nail strip; Bostik 70-05A applied to both sides of the male rib prior to seam engagement; -76.75 J1.5C-W2 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Jacksonville Beach Series 1.5” Clipless Max. 19-inch coverage One (1) #10 PH wood screws spaced 6-inch o.c. along the nail strip; Bostik 70-05A applied to both sides of the male rib prior to seam engagement; -97.25 J1.5C-W3 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC .032 Al Jacksonville Beach Series 1.5” Clipless Max. 19-inch coverage One (1) #10 PH wood screws spaced 3-inch o.c. along the nail strip; Bostik 70-05A applied to both sides of the male rib prior to seam engagement; -108.5 J1.5C-W4 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Jacksonville Beach Series 1.5” Clipless Max. 19-inch coverage One (1) #10 PH wood screws spaced 3-inch o.c. along the nail strip; Bostik 70-05A applied to both sides of the male rib prior to seam engagement; -161 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 6 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for Miami Series 1.75 Snap Lock over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) M1.75-W1 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC .032 Al Miami Series 1.75 Snap Lock Max. 14-inch coverage Miami Series 1.75 Snap Lock Clip with two (2) #10 PH wood screws spaced 12-inch o.c. -110.5 M1.75-W2 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Miami Series 1.75 Snap Lock Max. 18-inch coverage Miami Series 1.75 Snap Lock Clip with two (2) #10 PH wood screws spaced 16-inch o.c. -114.25 M1.75-W3 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC .032 Al Miami Series 1.75 Snap Lock Max. 14-inch coverage Miami Series 1.75 Snap Lock Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -114.25 M1.75-W4 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Miami Series 1.75 Snap Lock Max. 18-inch coverage Miami Series 1.75 Snap Lock Clip with two (2) #10 PH wood screws spaced 8-inch o.c. -156.75 Approved Systems for Palm Beach Series 1.5 Mechanical Seam over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) P1.5M-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Palm Beach Series 1.5 Mechanical Seam Max. 20-inch wide 90° seam Palm Beach Series 1.5 Mechanical Seam Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -63.5 P1.5M-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. Palm Beach Series 1.5 Mechanical Seam Max. 20-inch wide 90° seam Palm Beach Series 1.5 Mechanical Seam Clip with two (2) #10 PH wood screws spaced 24-inch o.c. -93.5 P1.5M-W3 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. Palm Beach Series 1.5 Mechanical Seam Max. 20-inch wide 90° seam Palm Beach Series 1.5 Mechanical Seam Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -101 P1.5M-W4 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 24 ga. Palm Beach Series 1.5 Mechanical Seam Max. 20-inch wide 180° seam Palm Beach Series 1.5 Mechanical Seam Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -123.5 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 7 of 7 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX B Approved Systems for Palm Beach Series 1.5 Mechanical Seam over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) P1.5M-W5 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC .032 Al Palm Beach Series 1.5 Mechanical Seam Max. 20-inch wide 180° seam Palm Beach Series 1.5 Mechanical Seam Clip with two (2) #10 PH wood screws spaced 6-inch o.c. -131 Approved Systems for Key West Series 5-V Crimp over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) K5VC-W1 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga. 5-V-Crimp Max. 24-inch wide One (1) #10 HWH wood screw with sealing washer placed through the apex of the inside rib at the panel lap and through the center rib of the panel (12-inch o.c. across the panel); Fastener rows spaced 16-inch o.c. -78.5 K5VC-W2 Min. 15/32 CDX plywood OPTIONAL Versashield Solo As required per FBC 26 ga. 5-V-Crimp Max. 24-inch wide One (1) #14 WoodZAC® HWH wood screw with sealing washer placed through the apex of the inside rib at the panel lap and through the center rib of the panel (12-inch o.c. across the panel); Fastener rows spaced 8-inch o.c. -106.75 Approved Systems for Stuart Line Series 1” Nail Strip over Wood Deck (New or Existing) System No. Deck Fire Barrier/ Insulation Underlayment Roof Panel Panel Attachment MDP (psf) S1NS-W1 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Stuart Line Series 1” Nail Strip Max. 16-inch coverage One (1) #10 PH wood screws spaced 12-inch o.c. along the nail strip; Bostik Chem-Calk 915 applied along the fasteners prior to seam engagement; -91.25 S1NS-W2 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier or insulation As required per FBC 24 ga. Stuart Line Series 1” Nail Strip Max. 16-inch coverage One (1) #10 PH wood screws spaced 6-inch o.c. along the nail strip; Bostik Chem-Calk 915 applied to top of male rib on fastening side prior to seam engagement; -136.75 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C, and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd = 0.85 8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. 12. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 13. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3ft Gable Hip . a a a 3 3 a 2 2 1 2 3 a 3 2 a 3 2 2 3 3 1 2 2 3 a a a a a 3 3 2 2 1 1 2 2 1 a 2 2 1 3 3 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6 25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7 40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5 50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2 60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8 2 20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0 25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2 50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5 60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5 3 20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4 25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2 40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0 50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9 60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8 Partially Enclosed 1 20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6 25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2 40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2 50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9 60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2 2 20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0 25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9 50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2 60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6 3 20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4 25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7 40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7 50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6 60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5 25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6 40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4 50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1 60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7 2 20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5 25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7 50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0 60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7 3 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5 40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3 50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2 60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1 Partially Enclosed 1 20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9 25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5 40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5 50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2 60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5 2 20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9 25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8 50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1 60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5 3 20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1 25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4 40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4 50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2 60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9 A CREEK Technical Services, LLC DRX19002.1 FL30304-R1 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. DREXEL METALS, INC. Metal Roofing APPENDIX C Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0 25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1 40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9 50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6 60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1 2 20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4 25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6 50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9 60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6 3 20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2 25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0 40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8 50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7 60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6 Partially Enclosed 1 20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8 25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5 40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5 50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1 60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5 2 20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2 25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2 50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5 60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9 3 20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1 25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4 40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4 50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2 60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9