HomeMy WebLinkAboutAPPROVED, S - Lloyd S&S (1)The Lloyd Residence
Aluminum Adjustable Pergola
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021
File:214631
341 Interstate Blvd. Phone:(941) 371-1724
Sarasota Florida 34240 Fax: (941) 847-0870
Certificate of Authorization Number 27383
www.DeStefanoEngineering.com
DE STEFANO
ENGINEERING GROUP, PL
8"8"8X8X3/16"
POST
19-63-265
6063-T52
7 9/16"12"7-9/16X12X3/16"
STRUXURE
CHANNEL
5052-H32
7-9/16X2X3/16"
STRUXURE
CHANNEL
5052-H32
7 9/16"2"1-3/4X1-3/4X.093"
CHANNEL
13-63-307
6063-T52
1 3/4"1 3/4"2X10X1/8"
BEAM
20-63-400
6063-T6
2"10"2X8X1/8"
FAN BEAM
20-63-295
6063-T52
2"8"6"
1 7/8"1 7/8"4 1/8"
6"
The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S1341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLS1
1 LOUVER
SCALE: 2" = 1'-0"S1
3 STRUCTURAL COMPONENTS
SCALE: 2" = 1'-0"
GENERAL NOTES:
DESIGN CRITERIA
THE STRUCTURAL SYSTEM FOR BUILDING DEPICTED HERE ON HAS
BEEN DESIGNED ACCORDING TO THE 2020 7TH EDITION OF THE
FLORIDA BUILDING CODE, ASCE 7-16, AND THE 2015 ALUMINUM
DESIGN MANUAL.
THE STRUCTURE HAS BEEN DESIGNED TO RESIST THE FOLLOWING
SUPERIMPOSED LOADS.
ROOF DEAD:2 PSF + SELF-WEIGHT
ROOF LIVE: 12 PSF
WIND LOADS ON THE STRUCTURE HAVE BEEN CALCULATED IN
ACCORDANCE WITH ASCE 7-16 FOR THE FOLLOWING: BASIC WIND
SPEED: 160 MPH (3 SECOND GUST), RISK CATEGORY: II, EXPOSURE
CATEGORY: B, PARTIALLY ENCLOSED 30 PERCENT SOLID.
ENCLOSURE CLASSIFICATION PER ASCE 7-16, TABLE 26.13-1 (FOR
4-SIDED RECTANGULAR LOUVERED AWNINGS)
LOAD COMBINATIONS:
D+0.6W 0.6D+0.6W D+L
DESIGN OF LOUVERED RIGID CANOPY IS PER SECTION 3105.5.1 OF
THE FBC, RIGID AWNINGS AND CANOPY SHUTTERS. LOUVERED
BLADES SHALL BE REPOSITIONED TO THE VERTICAL OPEN
POSITION DURING PERIODS OF HIGH WIND VELOCITY. UNIT IS
EQUIPPED WITH A WIND SENSOR WHICH WILL OPEN LOUVERS AT
45MPH.
PER FBC SECTION 3105.5.3, CONTRACTOR SHALL POST WITH A
LEGIBLE AND READILY VISIBLE DECAL OR PRINTED INSTRUCTIONS
TO THE OWNER OR TENANT TO REMOVE OR REPOSITION THE
STRUCTURE OR PART THEREOF DURING SUCH PERIODS OF TIME
AS DESIGNATED BY THE US WEATHER BUREAU AS BEING A
HURRICANE WARNING OR ALERT. THE WARNING LABEL SHOULD
READ AS FOLLOWS:
A CONTINUOUS LOAD PATH BETWEEN FOUNDATIONS, COLUMNS,
AND BEAMS ARE INTENDED BY THESE DRAWINGS AND SHALL BE
FIELD VERIFIED.
THE LOUVERED ROOFING SYSTEM SHALL BE INSTALLED IN
ACCORDANCE WITH STRUXURE LOUVERED ROOFING SYSTEM.
THE CONTRACTOR IS RESPONSIBLE FOR WATERPROOFING.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE
SUITABLE SEQUENCING, MEANS AND METHODS OF
CONSTRUCTION, INCLUDING, BUT NOT LIMITED TO THE ADDITION
OF NECESSARY SHORING, TIE DOWNS, TEMPORARY BRACING,
ETC.
THE INFORMATION USED AND CONTAINED HEREIN IS BASED ON
CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. DESTEFANO
ENGINEERING GROUP, PL (DEG) HAS NOT VISITED THIS JOB SITE.
DIMENSIONS AND EXISTING CONDITIONS SHALL BE FIELD
VERIFIED. DEG ASSUMES NO RESPONSIBILITY OR LIABILITY IN ANY
WAY FOR ERRONEOUS OR INACCURATE DATA OR
MEASUREMENTS. DEG SHALL BE NOTIFIED AND GIVEN AN
OPPORTUNITY TO RE-EVALUATE OUR WORK UPON DISCOVERY OF
ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF
EXISTING FIELD CONDITIONS, FABRICATION, AND/OR INSTALLATION
OF MATERIALS.
MATERIAL SPECIFICATIONS
ALUMINUM:
ALUMINUM SHALL BE A MINIMUM OF 6063-T6 UNLESS NOTED
OTHERWISE
ALUMINUM PLATE TO BE 6061-T6 ALLOY
FINISH COLOR TO BE SELECTED BY OWNER FROM
MANUFACTURES STANDARD COLORS FOR STANDARD
EXTRUSIONS.
CONCRETE FASTENERS TO BE 410 STAINLESS STEEL TITANS AS
MANUFACTURED BY SIMPSON STRONG TIES OR APPROVED
EQUAL.
ALL SMS SCREWS ARE 410 STAINLESS #12 x 1" SELF-TAPPING
METAL SCREWS (SMS) TYPICAL UNLESS OTHERWISE NOTED.
EXTRUDED STRUCTURAL TUBE OR PIPE: ALLOY SHALL BE BE
6061-T6, 6005-T6, 6063-T6. OR AS NOTED ON DRAWINGS AND
CONFORMING TO ASTM B429.
ALUMINUM IN CONTACT WITH CONCRETE SHALL BE COATED.
FOUNDATIONS
SEE STRUCTURAL DRAWINGS AND STRUCTURAL GENERAL NOTES
FOR ADDITIONAL INFORMATION.
BY VISUAL OBSERVATION, SOIL AT THE SITE IS SAND (OR SAND
AND ROCK) WITH AN ASSUMED SOIL BEARING CAPACITY OF 2000
PSF.
PERFORM ALL CONCRETE WORK IN ACCORDANCE WITH ACI 318,
THE BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE AND ACI 301, SPECIFICATIONS FOR STRUCTURAL
CONCRETE FOR BUILDINGS.
CONCRETE SHALL BE AN APPROVED MIX PROPORTIONED TO
ACHIEVE STRENGTH AT 28 DAYS AS LISTED BELOW WITH A
PLASTIC AND WORKABLE MIX.4000 PSI FOR FOUNDATIONS
CONCRETE SHALL COMPLY WITH THE REQUIREMENTS OF ASTM
C-94 FOR MEASURING, MIXING, TRANSPORTING, ETC. MAXIMUM
TIME ALLOWED FROM THE TIME THE MIXING WATER IS ADDED
UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED
ONE AND ONE HALF (1-1/2) HOURS.
REINFORCING STEEL:
REINFORCING STEEL: ASTM A615, GRADE 60 DEFORMED NEW
BILLET STEEL CONFORMING TO ACI 301, 315, 318, AND CRSI
MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE,
FREE FROM OIL, SCALE AND RUST, AND PLACED IN ACCORDANCE
WITH THE TYPICAL PLACING DETAILS OF ACI STANDARDS AND
SPECIFICATIONS.
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO
EARTH: 3 IN
GENERAL CONDITIONS
IF THERE ARE ANY DISCREPANCIES HEREIN CONTACT THE
ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
THIS DESIGN DOES NOT CONSTITUTE THE ENGINEERING OF ANY
OTHER STRUCTURES THAT ARE NOT SPECIFICALLY MENTIONED
HEREIN. IF THERE ARE ANY DISCREPANCIES THEREIN, CONTACT
THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
ALL WORK PREPARED BY DE STEFANO ENGINEERING GROUP, PL
(DEG), IS THE PROPERTY OF DEG AND MAY ONLY BE USED FOR ITS
INTENDED USE. THE DRAWINGS, SPECIFICATIONS AND OTHER
DOCUMENTS, INCLUDING THOSE IN ELECTRONIC FORM,
PREPARED BY DEG AND DEG'S CONSULTANTS ARE INSTRUMENTS
OF SERVICE THROUGH WHICH THE WORK TO BE EXECUTED BY
CONTRACTOR. AS DESCRIBED REMAIN THE PROPERTY OF DEG.
SAID WORK MAY NOT BE USED AT ANY OTHER LOCATION OR FOR
ANY OTHER USE WITHOUT PRIOR WRITTEN AUTHORIZATION.
DEG WILL HAVE NO RESPONSIBILITY FOR THE CONTRACTOR'S,
CLIENT'S OR OTHER ENTITIES; MEANS, METHODS, TECHNIQUES,
AND PROCEDURES USED IN CONSTRUCTION, AND WILL NOT BE
HELD LIABLE FOR THE CONTRACTOR'S INADEQUATE OR
UNSATISFACTORY PERFORMANCE OF THE WORK.
"THIS RIGID AWNING MUST HAVE
LOUVERED BLADES REPOSITIONED
TO THE VERTICAL POSITION DURING
A HURRICANE WARNING OR ALERT AS
DESIGNATED BY THE U.S. WEATHER
BUREAU (FBC SECTION 3105.5.3)."
30'-0"12'-0"7"2'-6"HOST STRUCTURE EAVE7" SUPER GUTTER
ADJUSTABLE
LOUVERS
8X8 POST
DOUBLE 2X10
FRONT BEAM
2X10 PERIMETER
BEAM, TYP.
S5
1
S5
2
S6
3 S6
4
S6
5
The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S2341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLARK A d e STEF
A
N
O.MPROF
ESSION A L RE N G INEEESNECIL
ADIROLF
No 61657
STATE OF
«««
November 30, 2021
S2
1 PLAN VIEW
SCALE: 1/4" = 1'-0"
HOST STRUCTURE EAVE7" SUPER GUTTER
7 1/2"9'-0 1/4"8"9'-0 1/4"8"9'-0 1/4"7 1/2"
2X8 FAN
BEAM, TYP.
7-1/2" STRUXURE XL
GUTTER SYSTEM,
TYP.
S6
7
The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S3341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLARK A d e STEF
A
N
O.MPROF
ESSION A L RE N G INEEESNECIL
ADIROLF
No 61657
STATE OF
«««
November 30, 2021
S3
1 REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
HOST STRUCTURE EAVE7" SUPER GUTTER
29'-4"14'-9"2'-6"26'-10"2'-6"2'-6"13'-6"3'-11"11"
30X30X16 FOOTING
W/ (3) #4 BARS
EACH WAY TOP
AND BOTTOM
The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S4341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLARK A d e STEF
A
N
O.MPROF
ESSION A L RE N G INEEESNECIL
ADIROLF
No 61657
STATE OF
«««
November 30, 2021
S4
1 FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
9'-0"10"DOUBLE 2X10
FRONT BEAM
8X8 POST
6"1'-4"9'-6"9'-0"10"7" SUPER
GUTTER
2X10 BEAM
8X8 POST
9'-6"6"1'-4"3/16" ARCADIA
CHANNEL GRADE LEVEL3/8" PLATE
(9) #14X1" SS SMS EACH
SIDE OF CHANNEL(4) 1/2"X4" SS TITEN HD
W/ 2-1/2" MIN. EMBED.
30"
3"3"3"16"6"30X30X16
FOOTING W/ (3) #4
BARS EACH WAY
TOP AND BOTTOM
The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S5341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLS5
1 FRONT ELEVATION
SCALE: 1/4" = 1'-0"
S5
2 SIDE ELEVATION
SCALE: 1/4" = 1'-0"S5
4 FOOTING DETAIL
SCALE: 1-1/2" = 1'-0"
TOP VIEW
ISOMETRIC VIEWSIDE VIEW
BEAM
CORNER INSERT
BEAM
#14 TEK SCREWS
THRU BEAM INTO
CORNER INSERT
EACH SIDE
BEAM
CORNER
INSERT
BEAM
CORNER
INSERT
(5) #14 TEK SCREWS
THRU BEAM CORNER
INSERT EACH BEAM
GUTTER CORNER EDGE (2) #14 TEK SCREWS
GUTTER EDGE
GUTTER CORNER
GUTTER
BEAM CORNER
CONNECTOR
BEAM
GUTTER
GUTTER CORNER EDGE
GUTTER
BEAM
CORNER
CONNECTOR
GUTTER CORNER
TOP VIEW
SIDE VIEW
ISOMETRIC VIEW
GUTTER
GUTTER EDGE
GUTTER CORNER
CORNER
CONNECTORBEAM
FASTEN GUTTER
TO BEAM W/ #12
SS SMS @ 12" O.C.
SIDE VIEW
BEAM
U CHANNEL (4) #14-24X1" SS
SMS EACH SIDE
(10) #14-24X1"
SS SMS
8"
LOUVER PROFILE
FOR COMPARISON
PIVOT CAP
PIVOT TRACK
TRACK PIN 5/16"
DIA. SS PIN
2X10 BEAM INTERNAL GUTTER
#10X1" SS SMS
AT 12" O.C.
2X10X1/8" BEAM
GUTTER
2X8X1/8" FAN BEAM
1-3/4X1-3/4X1/8
U CHANNEL
(3) #12-24
SS SMS
EACH SIDE
(3) #12-24
SS SMS
DOUBLE
2X10 BEAM
#14X3" SS
SMS SPACED
AT 24" O.C.3"5"2"7" SUPER
GUTTER
(2) 3/8" WOOD LAGS WITH
2" MIN. EMB. INTO WOOD
TRUSS CORD AT 24" O.C.,
TYP.
(4) #14 SS SMS
SPACED AT 12"
O.C.
2X10X1/8"
BEAM
1/8" ANGLE
(4) 1/2"X4" SS TITEN HD
W/ 2-1/2" MIN. EMBED.
(9) #14-24X1" SS
SMS EACH SIDE
OF CHANNEL
7-9/16X12X3/16"
ARCADIA CHANNEL
7-1/4X7-1/4X3/8"
PLATE
1"6"1"8"
1"6"1"8"The Lloyd Residence
1524 NW Buttonbush Cir.
Palm City, FL 34990
October 29, 2021 File:214631 of 6
S6341 Interstate Blvd. Phone:(941) 371-1724Sarasota Florida 34240 Fax: (941) 847-0870Certificate of Authorization Number 27383www.DeStefanoEngineering.comDE STEFANOENGINEERING GROUP, PLARK A d e STEF
A
N
O.MPROF
ESSION A L RE N G INEEESNECIL
ADIROLF
No 61657
STATE OF
«««
November 30, 2021
S6
1 BEAM CORNER ASSEMBLY
SCALE: 2" = 1'-0"
S6
2 GUTTER CORNER ASSEMBLY
SCALE: 1-1/2" = 1'-0"
S6
3 BEAM TO POST DETAIL
SCALE: 1-1/2" = 1'-0"S6
6 LOUVER MOUNT DETAIL
SCALE: 1-1/2" = 1'-0"
S6
7 FAN BEAM DETAIL
SCALE: 1-1/2" = 1'-0"
S6
4 DOUBLE BEAM SECTION
SCALE: 1-1/2" = 1'-0"
S6
5 BEAM TO SUPER GUTTER DETAIL
SCALE: 1-1/2" = 1'-0"
S6
8 POST BASE DETAIL
SCALE: 3" = 1'-0"