Loading...
HomeMy WebLinkAboutProduct Approval ( Windows Mullions )8/23/2021 RECEIVED Florida Building Code Online Felida a o r t!^xsetM' ea BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Ow Product Approval USER: Public User Product Approval Menu > Product Agolication Search > Agoiication List > Application Detail ' • EVI r �r `1j or j CODE COMPLIANCE FL# FL17472-R8 Application Type Revision ST. PIE COUNTY �a����G�� Code Version Application Status A2020 Approved pproved n��d���i� - *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800) 432-2204 Ext4305 easengineering@easternmetai.com Authorized Signature James Flesher easengineering@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800) 432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Keystone Certifications, Inc. Referenced Standard and Year (of Standard) Standard Year AAMA 450 2010 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A https:ltfloddabuilding.org/pr/pr app_df.aspx?param=wGEVXQwtDgtCUGgvjQiz6AvC%2bOtoUJS%2fzVOHhmwXlurebbsfQRogew%3d%3d 1/2 8/23/2021 Florida Building Code Online Date Submitted 07/14/2021 Date Validated 07/14/2021 Date Pending FBC Approval Date Approved 07/16/2021 Summary of Products FL # Model, Number or Name Description 17472.1 HVHZ Clipped Aluminum Bay/Bow HVHZ Clipped Aluminum Bay/Bow Mullion Mullion Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL17472 R8 C CAC 622-104 C3R1.pff Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 09/22/2024 Design Pressure: N/A Installation Instructions Other: See drawing set for mullion size, angle and design FL17472 R8 II PA-0004 HVHZ Mulls SS 2021-06-14.pdf pressure rating Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports EL17472 R8 AE PER7618 SS 2021-06-13.pd Created by Independent Third Party: Yes 17472.2 Clipped Aluminum Tube Mullion HVHZ Clipped Aluminum Tube Mullion Vertical, Horizontal, T 0)HVHZ and X Configurations Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL17472 R8 C CAC 622-101 C3R1.pdf Approved for use outside HVHZ: Yes FL17472 R8 C CAC 622-102 C3Ri.pd Impact Resistant: Yes FL17472 R8 C CAC 622-103 C3Rl.p_df Design Pressure: N/A FL17472 R8 C CAC 622-105 C3Ri.p f Other: See drawing set for mullion size, configuration and FL17472 R8 C CAC 622-106 C3R1.pdf design pressure rating Quality Assurance Contract Expiration Date 07/18/2024 Installation Instructions FL17472 R8 II PA-0003 HVHZ Mulls SS 2021-06-14.pdf Verified By: Hermes F. Norero, P.E. 73778 Created by Independent Third Party: Yes Evaluation Reports FL17472 R8 AE PER7619 SS 2021-06-13.1df Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. sgpyrlaht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: MW-M ® Fi=k Credit Card Safe hftps:ltfloridabuilding.org/prlpr app_df.aspx?param=wGEVXQwtDgtCUGgN,jQiz6AvC%2bOtoUJ5%2fzVOHhmwXlurebbsfQRo9ew°/a3d%3d 2/2 Document Title: Structural Performance Doc No: FRM B1-02 Rev No: 7 Page: 1 a: 1 >�TEYSTON CeRFICATIONS, INC. Certification I Authorization Report Required By: PRO B1-03 CAR & Product ID Number: 622 - 103.0 Issue Date: 1/16/2015 Revision Date: 5/ 1 Expiration Date: 7/18/2024 Company Code: 6 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, 'including .installation, condition of the wall/roof substrate. and the age of the product and installation components. This report indicates the product is eligible fur the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified atwww.keystonecerts.com. Licensee Information: Product Information: Eastern Architectural Systems Model: 1 "x4" Aluminum Mullion HN/T/X 16341 Domestic Ave Operator Type: Mull Fort Myers, FL 33912 Config: No Reinforcement USA Max Width: See Table Max Height: See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Qualifying Test Information: Test ReportNo: �CTLA-3010W-8A/9A Test Report Expiration: 4 Authorized Signature: Keystone Certifications, Inc. 145 Limekiln Rd. Suite 100E Aaron Shultz K�-Y o New Cumberland, Pennsylvania 17070 '00'04-15:12:13 2021.05.19 ". P Phone: 717-932-8500 Fax: 7.17-932-8501 W W W. KEYSTONECERTS.COM KEY NE' Appendix 1 CAR No: 622-103.0 CHRTII•ICATONB. �N�. Expiration Date: 7/18/2024 Eastern Architectural Systems 10030 Bavaria Road Fort Myers, FL 33913 Load Tables for the: 1"x4" Aluminum Mullion, Horiz/Vert/T/X DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" - ONE-WAY MULLIONS SPAN TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 .200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 1 5 161.6 147.9 139.7 138.6 132.6 84 200.0 159.9 130.4 111.2 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 1 86.3 73.2 64.1 57.4 53.1 52.5 48.8 108 98.1 74.2 1 60.1 50.8 44.3 39.5 36.3 35.9 33.1 DESIGN PRESSURE LIMITS FOR MULLION: 1" x 4" - TWO-WAY MULLIONS SPAN 'L' TRIBUTARY WIDTH 'W' (IN.) (IN.) 18 1 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5 48 200.0 200.0 200.0 200.0 200.0 186.1 168.1 165.4 148.8 60 200.0 200.0 200.0 198.5 j 170.1 148.8 134.5 132.3 119.1 72 200.0 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3 84 200.0 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9 96 138.2 103.7 82.9 69.1 59.2 51.8 46.8 46.1 41.5 108 97.1 72.8 58.2 48.5 41.6 36.4 32.9 32.4 29.1 Impact Ratings ASTM E1996 -Wind Zone 4, Missile Level D PA/TAS 201/203 - Large Missile and Small Missile compliant Keystone Certifications, Inc. 145 Limekiln Rd, Suite 100B New Cumberland, PA 17070 Phone: 717.932.8500 www.keystonecerts.com ^ 000 BUILDING DROPS ® A Perfect Solution in Every Drop Certificate of Authorization: 29578 November 23, 2020 TO: Whom It May Concern FROM: Hermes F. Norero, P.E. Registered Florida Professional Engineer #73778 MANUFACTURER: Eastern Architectural Systems 16341 Domestic Ave. Ft. Myers, FL 33912 FLORIDA PRODUCT APPROVAL M FL17472 PRODUCT CATEGORY: Windows SUBJECT: Dear Sir (Madam), 398 E. Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Conformance to the 7' Edition (2020) Florida Building Code I have reviewed the referenced Florida Product Approval and associated documents and found all drawings, reports, referenced test standards, and associated ancillary tests as noted in the currently approved documents listed below to be in compliance with the 7th Edition of the Florida Building Code. It has been concluded that no revisions or changes to the referenced standards and standard years has occurred between Chapter 35 of the 61h Edition and Chapter 35 of the 7th Edition of the Florida Building Code. Therefore, all tgst ftaydaids listed �elgw ire Valy fqr tqe 71I h Yitipn of Te Ftlor+da,Bugdirig C+odj. SECTION INSTALLATION INSTRUCTIONS CERTIFICATE NO. CERTIFICATION AGENCY TEST STDS. AAMA 450-10 Keystone TAS201-94 17472.1 PA-0004 622 -104.0 Certifications, Inc. TAS202-94 TAS203-94 622 - 101.0 AAMA 450-10 622 -102.0 Keystone TAS201-94 17472.2 PA-0003 622 -103.0 Certifications, Inc. TAS202-94 622 -105.0 TAS203-94 622 -106.0 Hermes F. Norero, P.E. Florida P.E. No 73778 Page 1 of 2 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop! Dania Beach, FL 33004 Certificate of Authorization: 29578 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com To the best of my knowledge, all referenced & included test standards, methods of installation, details, and performance ratings have been found to comply.with the 7th Edition of the Florida Building Code. This product is manufactured under a quality assurance program currently approved by the Florida Building Commission. Please note that I do not have, nor will I acquire, a financial interest in any company manufacturing or distributing the product(s) for which the reports are being issued. I also do not have, nor will I acquire, any.financial interest with the Laboratory that performed the test(s), or with the Engineer witnessing the test(s) and sealing the test report(s). Respectfully submitted, N .7 7 ° �6. S A OF i���Fss O L .� Hermes F. Norero, P.E. Florida Registered Professional Engineer #73778 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2020.12.07 07:25:55-05'00' Hermes F. Norero, P.E. Florida P.E. No 73778 Page 2 of 2 BUILDING DROPS • A Perfect Solution in Every Dropl Certificate of Authorization: 29578 Product Evaluation Report Of Eastern Architectural Systems HVHZ Clipped Aluminum Tube Mullions for Florida Product Approval FL# FL17472 Report No. 7619 Current Florida Building Code Method: Category: Sub — Category: Product: Material: 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com 1— A (Certification) Windows Mullions HVHZ Clipped Aluminum Tube Mullions Aluminum 6005-T5 & 6063-T6 Prepared for: , Eastern Architectural Systems 16341 Domestic Ave. Ft Myers, FL 33912 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:05/25/21 Contents: Evaluation Report Pages 1-3 Digitally signed by Hermes F Norero Reason: I am approving this document Date: 2021.06.13 14:27:09-04'00' Hermes F. Norero, P.E. Florida No. 73778 /J/6A\\) BUILDING DROPS A Perfect Solution in Every Drop Certificate of Authorization: 29578 Manufacturer: Eastern Architectural Systems Product Category: Windows Product Sub -Category: Mullions Compliance Method: State Product Approval Method (1)(a) Product Name: _ HVHZ Clipped Aluminum Tube Mullions FL#:FL17472 Date: 05/25/21 Report No: 7619 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Eastern Architectural Systems based on Method 1a of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions PA-0003, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). ' 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. Individual window units must be impact rated where applicable. 4. Site conditions that deviate from the details of drawing PA-0003 require further engineering analysis by a licensed engineer or registered architect. S. All configurations shown in installation instructions PA-0003 have been qualified as required by Section 1709.8 of the Current Florida Building Code. 6. See Installation Instructions PA-0003 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 1(1,,\\ BUILDING DROPS FL#: FL17472 A Perfect Solution in Every Dropl Date: 05/25/21 16 Certificate of Authorization: 29578 Report No: 7619 Certification Agency: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a Certification Agency through Keystone Certifications, Inc. (FBC Organization M CER1523). Referenced Test Standards: Referenced Data: Installation: • AAMA 450-10 • TAS 201-94 • TAS 202-94 • TAS 203-94 1. Product Testing performed by: Certified Testing Laboratories (FBC Organization #: TST1577) Report M CTLA 3010W-4A Report Date: 07/18/14 Report M CTLA 3010W-5A Report Date: 07/18/14 Report M CTLA 3010W-6A Report Date: 07/18/14 Report M CTLA 3010W-7A Report Date: 07/18/14 Report #: CTLA 3010W-8A Report Date: 07/18/14 Report #: CTLA 3010W-9A Report Date: 07/18/14 TAS Reports Signed and Sealed by: Ramesh Patel, PE 20224 2. Certification Agency Keystone Certifications, Inc. (FBC Organization M CER1523) Refer to Installation Instructions (PA-0003) for anchor locations, design load tables, and further details of the installation requirements. Design Pressure: See drawing (PA-0003) for mullion design pressure tables, mullion profiles, and installation details. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3 EASTERN ARCHITECTURAL SYSTEMS HVHZ CLIPPED ALUMINUM TUBE MULLIONS GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE. 3. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. INDIVIDUAL UNITS ATTACHED TO MULLIONS MUST BE IMPACT RATED. 4. ADEQUACY OF THE EXISTING STRUCTURALCONCRETE/MASONRY AND 2X FRAMING ASA MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. S. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 6. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERICAND MAY NOT REFLECTACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECTSHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONETIME PRODUCT APPROVALTO BE OBTAINED FROM MIAMI-DADE FIER. 7. MULLION & CUP MATERIAL: ALUMINUM 6005-TS & 6063-T6 (AS NOTED) S. MULLIONS MAYBE USED WITH ANY APPROVED FENESTRATION PRODUCT, UNDER SEPARATE APPROVAL 9. SEE SHEETS 5-10 FOR INSTALLATION ANCHOR REQUIREMENTS FOR SPECIFIC ANCHORING REQUIREMENTS, MULLION CONFIGURATIONS, AND DESIGN LOAD CAPACITIES. 10. DISSIMILAR METALS INCLUDING FASTENERS THAT MAY COME INTO CONTACT WITH ALUMINUM UNIT FRAMING SHALL BE PROTECTED IN ACCORDANCE WITH THE CURRENT FLORIDA BUILDING CODE. TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 - GENERAL NOTES, INSTRUCTIONS, AND ELEVATIONS 2 - MULLION CROSS SECTIONS 3 - ANCHOR CUP DETAILS 4 - MULLIONSECTIONS 5 - TYPICAL MULLION &CUP ASSEMBLIES 6 - 1" X 3-1/8" (LIGHT) MULLION DESIGN LOAD TABLES 7 - 1" X 3-1/9' (HEAVY) MULLION DESIGN LOAD TABLES S - 1" X 4" MULLION DESIGN LOAD TABLES 9 - 2"X 4' MULLION DESIGN LOAD TABLES 10 - 2" X 6' MULLION DESIGN LOAD TABLES 11 - MULLION ASSEMBLY AND LOAD EXAMPLES Digitally signed by Hermes F Norem Reason: I am approving this document Dale: 2021.06.14 10:59:49 -04'00' r_,W1'-1n-'W2'I ANCHOR CLIP, TYP �� r" /l VERTICAL MULL E SPAN W 4 MULLION TYP. %/ ANCHOR CLIP, A TYP 4 TYPICAL MULLION ASSEMBLY INSTRUCTIONS: 1. DETERMINE REQUIRED DESIGN PRESSURE FOR OPENING. 2. CHOOSE A MULLION THAT PROPERLY FITS THE FENESTRATION PRODUCT. 3. DETERMINE WHETHER ASSEMBLY REQUIRES ONE-WAY OR TWO-WAY MULLIONS: • ASSEMBLIES CONSISTING OF STACKED OR SIDE -BY -SIDE UNITS REQUIRE USE OF ONE-WAY MULLIONS. ' • ASSEMBLIES CONSISTING OF MULTIPLE UNITS MULLED TOGETHER WITH MULTIPLE MULLIONS REQUIRE USE OF TWO-WAY MULLIONS. • SEE SHEET 11 FOR ASSEMBLY AND LOAD EXAMPLES. • IF ASSEMBLY TYPE CANNOT BE DETERMINED USE TWO-WAY MULLION CHART. 4. VERIFY THAT MULLION DESIGN PRESSURE MEETS OR EXCEEDS REQUIRED DESIGN PRESSURE OF OPENING USING CHARTS ON SHEETS 6-10. S. QUALIFIED CUP TYPES APPEAR ON SHEETS 6-10. MULTIPLE ANCHOR TYPE/SUBSTRATE/CLIP COMBINATIONS WITHIN AN OPENING ARE ALLOWED. 6. THE LESSER DESIGN PRESSURE OR MULLION OR FENESTRATION PRODUCT WILL GOVERN OVERALLASSEMBLY DESIGN PRESSURE RATING. REVISIONS o SA OF ra'� p (pP /U�� SM 5/25/21 FBC UPDATE SM 2/6/18 6TH ED. FBC UPDATES 398 DNM GI BLYl1. 11B DFJNF BG�IdJE1U 1.7004 BY MTE oEBCRIV110N FePE QAT. OF w unDN No. 2vs2e r'Wl'+'W2' 1 I 7 MULL 0 0 SPAN'L' VERTICAL SPAN MULL SPAN'L' !/ < \, 'W2' HORIZONTAL "T" MULL SPAN MULL SPAN'L' El 'W2' r� HORIZONTAL SPAN EF YIERNARCMTEONILLL SYSTEKS -�� EeStern =Y ■ A 100,R3 DOMFSM AYE Fr MYERS.FL!Qs12 YISe HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS BUIU)ING DROPS, INC +n � FBPECERFIFrAUOF AUFNORIZATION NO.295F8 1.000" 0.125" 3.125" 0.375" 1" X 3-1/8" (LIGHT) MULLION SEE SHEET 6 FOR QUALIFIED CLIPS 1.000" 0.125" 3.125" 0.625" 1" X 3-1/8" (HEAVY) MULLION SEE SHEET 7 FOR QUALIFIED CLIPS NOTE: SEE SHEET 3 FOR SPECIFIC CLIP TYPES AND DIMENSIONS. REVISIONS Fwst+MO�`,•rRr'E'� Eastern • ' � ' E'• ,' r(0)2 7 eZ CLIPPED ALUMINUM TUBE MULLIONS ICAL AND HORIZONTAL CONFIGURATIONS S A OF a: MULLION CROSS SECTIONS DAIS: DRAWN BY:O T1HSr°'c' FBEBUIM'CWFICATEOF �N.T.S. AUTHORIZATION NO.2•S78 a•• D BEACH BLM. 17a sHFEr: RM. .__.`.._ __� BY OAIB DESCRIPTION REv 20F11 - �4"-------- 0 0 2.625" 3.375" 0 0 2.25" 0.125" 2" 2" X 4" X 3 3/8" L-CLIP ALUMINUM 6063-T6 A 5. 2.25" o /1, 2.215" 0 2.25" 0.121 2" I 2" X 5" X 21/4" L-CLIP ALUMINUM 6063-T6 I 5• 1 2.25" 1.75" 0 2.25" o 0.125" 2" 11� 2" X 5" X 13/4" L-CLIP ALUMINUM 6063-T6 � 4" 1 5.375" Ir LL7'I '�j' 0.125" 2' 2" X 4" X 5 3/8" L-CLIP 10.46" ALUMINUM 6063-T6 2.50" 0.722"----J 2.25" 0 2.25" � I o -T 0.722"� 10.46" 0 2.25" 0 2.25" 0 1.75' ° 2.25" o 0 2.25" � 0 � � 2.335" 2.25" O.SSB" —T —T �2,25' 2.25' 0 i 2.25' o 1.25" 2.125" 2.125" .188" T 10 15/32" X 2 1/4" H-CLIP � � � 01.zs" 2 1/4" U-CLIP 13/4" U-CLIP ALUMINUM 6063-T6 ALUMINUM 6005-TS ALUMINUM 6005-TS u "' 1015/32 X 13/4 H-CLIP ALUMINUM 6063-T6 8.25" 2.25" + 2.25" f 2.25" - 0 0 0 0 2.625" \ / `\ \ � / /' REVISIONS _'r- ADMBgN OF o'' i ��` , • E.. '% ■ emu... u.,. nwo v r-1Y� I6iC1 DOMESfICAVE •'�� S � 'iO i� ,Eastern 0.125" ti anaDisiaD A N .7 HVHZ CLIPPED ALUMINUM TUBE MULLIONS 0.875" VERTICAL AND HORIZONTAL CONFIGURATIONS S A OF G Z CUP DETAILS 81/4" X 3 3/8" H-CLIP BUILDING DROPS. INC ALUMINUMfi063-T6 �QS NO G\\�� PA-0003 N.T.S. AunanwnoNNO.°2MB Br oA,E DescxlPnox INSTALLATION ANCHOR (SEE NOTES SHEETS INSTALLATION ANCHOR INSTALLATION ANCHOR 6-10) 2 1/2" MIN. (SEE NOTES SHEETS 11/2" MIN. (SEE NOTES SHEETS HORIZONTAL EDGE DIST. 6-10) EMBEDMENT 6-10) MULLION, TYP. CONCRETE OR".4 e MASONRY BYOTHERSCAULK BETWEEN 3 4" MIN. 1 1/4" MIN. /CONCRETE/ EXTERIOR MULLION CLIP MASONRY& SX EDGE DIST. EMBEDMENT 'V . P. WOOD BUCK BY OTHERS c ��l TYP. X WOOD BUCK CONCRETE OR EXTERIOR INTERIOR BY OTHERS MASONRY BY OTHERS CAULK BETWEEN Q MULLION CLIP CONCRETE/ MASONRY & 2X VERTICAL TYP. WOOD BUCK BY OTHERS a MULLION, TYP. Q . ( ( 2XWOOD BUCK EXTERIOR ( ( INTERIOR BY OTHERS - a . MULLION INTERIOR TYP. ("ORIZONTAL SECTION ( MULLION TYP 4 T-MULLION INTERSECT DETAIL HORIZONTAL SECTION SIDEVIEW VERTICAL SECTION 4 JAMB -2XWOOD BUCK 4 HEAD-CONCRETE/MASONRY SIDE VIEW -HORIZONTAL SIDE VIEW -VERTICAL INSTALLATION ANCHOR (SEE NOTES SHEETS 6-10) EXTERIOR i I INTERIOR ( MULLION ( TYP. ( MULLION CLIP ( TYP. a 4 ° e 11/4" MIN. :d • ° EMBEDMENT PRECASTSILL e ° BY OTHERe INSTALLATION ANCHOR (SEE NOTES SHEETS 6-10) 2 1/2" MIN. EDGE DISTANCE VERTICAL SECTION 4 SILL-CONCRETE/MASONRY SIDE VIEW -VERTICAL NOTE DETAILS SHOWN ARE TYPICAL FOR ALL MULLION & CLIP ASSEMBLIES. SEE SHEETS 6-10 FOR ALLOWABLE MULLION CONFIGURATIONS, SIZES, AND DESIGN PRESSURES. l r �u * S A OF s je REVISIONS MiE OFSCNIVfpN MULLION, TYP. EXTERIOR INTERIOR MULLION CLIP ® ® TYP. VERTICAL lr�M TYP. E HORIZONTAL SECTION �(IJ X-MULLION INTERSECT DETAIL SIDE VIEW �� itastern FASIE""°MMC`RSYTSfEMS ■ `Y ,A..�. o yD ov` ff'= OMFSNCU YY FFMYERS, iL 33912 Kv �,.. ve w,.."ow� .re w� 1ATT�812188 HVHZ CUPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS INSTALLATION DETAILS O8T£ olaAwN er: vNEanNEU BY: 02 OS 13 TJH �J' eunouconocs,INc ONAW81a N0: SC1�LE FBFEO:BIIFIGTEOF PA-0003 N.T.S. AMOB TIONNO. 29578 sxEEr. NFv: 40F11 VERTICAL MULLION U-CLIP TO MULLION CONNECTION H-CLIP HORIZONTAL MULLION SUBSTRATE BY OTHERS SUBSTRATE VARIES, SEE NOTES SHEETS 6 -10 H-CLIP ANCHORS ALL INSTALLATION HOLES MUST HAVE AN ANCHOR INSTALLED IN THEM MULLION AND CLIP ASSEMBLY TYPICAL ASSEMBLY SHOWN WITH 1" x 3 1/8" MULLION AND H-CLIP. OTHER MULLIONS AND CLIPS ARE APPROVED. SEE INDIVIDUAL MULLION SHEETS REVISIONS -� EASTERNAacNORasrsrEMs Eastert� ��• E,.S •• �O ' fADMIDONF �,M��sr / rro. w..aoe.r+...a eon+. nMffJtS FLMAYE 1a cT MrBRs, F�S99n ' N .7 7 an a,a,m TaTE CLIPPED ALUMINUM TUBE MULLIONS * * HVHZ VERTICAL AND HORIZONTAL CONFIGURATIONS S A OF �p MULLION AND CLIP ASSEMBLY DETAILS PNEPAREDar: P :' ��� x6 O ID <V aye ONAINN BY. OS 13 T1H `� .INC AMGNG: SCµE: / BUBDIN FIUTEOF �PA-0003 1_!2 N.T.S. ALTORIZATIGNNO.29578 wa o BEACH axTax Br wTE DESCRIPTION r�r amrAnaN Nn a9sTe S OF 11 DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3-1/8" (LIGHT) - ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 181.0 158.0 143.3 134.3 129.8 129.3 127.6 72 161.6 123.7 101.5 87.3 77.7 71.1 67.2 66.7 63.8 84 101.0 76.9 62.7 53.5 47.1 42.6 39.7 39.3 36.9 96 67.4 51.1 41.5 3,5 2 30.8 27.6 25.6 25.2 23.5 108 47.2 35.7 28.9 24.4 213 19.0 17.5 17.2 15.9 DESIGN PRESSURE LIMITS FOR MULLION: V x 3-1/8" (LIGHT) -TWO-WAY MULUONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0 48 200.0 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0 200.0 160.8 134.0 114.9 100.5 90.8 89.3 80.4 72 157.6 118.2 94.5 78.8 67.5 59.1 53.4 52.5 47.3 84 99.2 74.4 59.5 49.6 42.5 37.2 33.6 33.1 29.8 96 66.5 49.9 39.9 33.2 1 28.5 24.9 22.5 22.2 19.9 108 46.7 35.0 28.0 23.3 1 20.0 17.5 15.8 1 15.6 1 14.0 QUALIFIED ANCHOR CLIPS 0 0 0 21/4" U-CLIP ALUMINUM 6005-T5 U-CLIP FOR USE ONLY IN MULLION -TO -MULLION CONNECTIONS NOTE: SEE SHEET 3 FOR SPECIFIC CLIP TYPES AND DIMENSIONS. �{ 1.000" 0.125" 3.125" 0.375' 1" X 3-1/8" (LIGHT) MULLION 0 0 0 0 0 0 2" X 5" X 2 1/4" L-CLIP ALUMINUM 6063-T6 "MUST BE USED IN PAIRS O 0 0 0 0 0 1015/32" X 2 1/4" H-CLIP ALUMINUM 6063-T6 ALUMINUM 6005-TS TRIBUTARY WIDTH = Wl+W2 2 MULLION[___7 X 1_1 MULLION ONE-WAY MULLION DIAGRAMS TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES. SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS & CUP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 5. ANCHOR REQUIREMENTS: • WOOD: #14 WOOD SCREWS • CMU: 1/4" ITW TAPCONS • CONCRETE: 1/4" ITW TAPCONS • METAL: 1/4" SELF -DRILLING SCREWS (GRADE 5) 6. INSTALLATION SUBSTRATES: • WOOD ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/2" & EDGE DISTANCE OF 1". WOOD SHALL BE MIN. S.G: 0.55. • HOLLOW CMU ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/4" & EDGE DISTANCE OF 2-1/2". HOLLOW CMU SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. • CONCRETE ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-3/4" & EDGE DISTANCE OF 2-1/2". CONCRETE SHALL BE MIN. 4000 PSI. • METAL ANCHORS SHALL HAVE A MIN. (3) THREADS PENETRATION BEYOND METAL STRUCTURE. STEEL SHALL BE MIN. 18 GA. (0.045" THICK) 33 KSI YIELD. ALUMINUM SHALL BE MIN.1/8" THICK ALUMINUM 6063-T5. ``\\�- F O-•/��' ��• E..S •• : N .7 7 It * r 0 S A OF o 13 � i�.(� O IOP'.' tv � I S G used � ....._ _ � ._ _- REVISIONS EAGTERN ^DnRCN MTuo usrs�ats JEastern E�sreNN MEnusrPar ■ l n w. I6 IDOMESIICAVE „4d6` ...«�r:'� uuwv�: u o'oenn "WERS,11M an+oi¢i90 ,ram HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS 1" x 31 8" LIGHT MULLION wte 02 OS 13 DRxwN Br: TJH PNerxRED Br: / ( BUIUNIG DROPS, INC AUTHOWA ONNO.29M DRN PA-0003 5"BEe .,c „ N.T.S. REV: Br Date DEscHIPrroN REv DESIGN PRESSURE LIMITS FOR MULLION: 1" x 3-1/8" (HEAVY) - ONE-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) IN. 18 24 30 36 42E34.5 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 191.4 176.7 162.2 161.6 159.4 72 200.0 154.5 126.8 109.1 97.1 94.0 83.3 79.7 84 126.2 96.1 78.4 66.8 58.9 49.6 49.1 46.1 96 94.2 63.9 51.8 44.0 38.5 31.9 31.5 29.3 108 58.9 44.6 36.1 30.5 26.6 23.7 21.8 21.5 19.9 DESIGN PRESSURE LIMITS FOR MULUON: 1" x 3-1/8" ( HEAVY) - TWO-WAY MULLIONS SPAN'L' TRIBUTARY WIDTH" W' (IN.) (IN.) 18 24N744.4 36 42 48 53.125 S4 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 191.4 167.5 151.3 148.9 134.0 48 200.0 200.0 167.5 143.6 125.6 113.5 111.7 100.5 60 200.0 200.0 134.0 114.9 100.5 90.8 89.3 80.4 72 196.8 147.6 98.4 84.4 73.8 66.7 65.6 59.1 84 124.0 93.0 62.0 53.1 46.5 42.0 41.3 37.2 96 83.0 62.3 49.8 41.5 35.6 31.1 28.1 27.7 24.9 108 58.3 43.7 35.0 29.2 25.0 21.9 19.8 19.4 17.5 1.000" 0.125" 3.125" 1 MULLION MULLION ONE-WAY MULLION DIAGRAMS 0.625" 1" X 3-1/8" (HEAVY) MULLION ALUMINUM 6005-TS MULLION TRIBUTARY WIDTH= W1+W2 2 QUALIFIED ANCHOR CLIPS no 13/4" U-CLIP o ALUMINUM 6005-TS 0 0 0 Fo 0 U-CLIP FOR USE ONLY IN CONNECTIONS ULLION 2" X S" X 13/4" L-CLIP ALUMINUM 6063-T6 **MUST BE USED IN PAIRS O O O NOTE: SEE SHEET 3 FOR SPECIFIC CUP TYPES AND DIMENSIONS. 1 o 0 0 10 15/32" X 13/4" H-CLIP ALUMINUM 6063-T6 TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES. SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS & CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CUP DIMENSIONS. S. ANCHOR REQUIREMENTS: • WOOD: N14 WOOD SCREWS • CMU:1/4" ITW TAPCONS • CONCRETE:1/4" ITW TAPCONS • METAL:1/4" SELF -DRILLING SCREWS (GRADE 5) 6. INSTALLATION SUBSTRATES: • WOOD ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/2" & EDGE DISTANCE OF 1". WOOD SHALL BE MIN. S.G: 0.55. • HOLLOW CMU ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/4" & EDGE DISTANCE OF 2-1/2". HOLLOW CMU SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. • CONCRETE ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-3/4" & EDGE DISTANCE OF 2-1/2". CONCRETE SHALL BE MIN. 4000 PSI. METAL ANCHORS SHALL HAVE A MIN. (3) THREADS PENETRATION BEYOND METAL STRUCTURE. STEEL SHALL BE MIN. 18 GA. (0.045" THICK) 33 KSI YIELD. ALUMINUM SHALL BE MIN. 2/8" THICK ALUMINUM 6063-TS. "I1� -^y�/�' �.\, E. S •• ' O j N .7 7 * v S A O� �' A 0.p O )Or-:: /,. ,, ♦ REVISIONS Eastern EASTERN ARCMRECTUfUlBYB1FAf9 ro� FASiERN NEFAL SYPPLY ,�..a': w...00..: �..o 000.� 163610OMMCAVE wo v,wva- �FAy[BS.iL o391y TITM HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS 1" x 31 8" HEAW MULLION DAM N05 13 oRAw10c PA-0003 DRAWN BY: T1H N.T.S. PNEGARED BY: / BUINGOROMINC HB FBDE [ERTIFRATEOF AUTHORIZATION NO.295Te aae y+Uoiu STa � W _ �� ��� 7lIC 71 REV: _ BY GATE OEBCRIPTION REV DESIGN PRESSURE LIMITS FOR MULUON: 1" x 4" - ONE-WAY MU W ONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) IN.) 18 24 30 36 42 48 53.125 54 60 200.0 200.0 200.0 200.0 2000. 2000. 200.0 200.0 36 200.0 200.0 200.0 200. 200.0 200.O 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 181.5 16L6 147.9 139.7 138.6 132.6 84 100.2 159.9 130.4 112-2 98.0 88.5 82.5 81.7 76.7 96 140.1 106.3 86.3 1 73.2 64.1 57.4 53.1 52.5 48.8 108 98.1 74.2 60.1 50.8 44.3 39.5 36.31 35.9 33.1 DESIGN PRESSURE LIMITS FOR MU W ON: 1" x 4" - TWO-WAY MU W ONS SPAN'L' TRIBUTARY WIDTH'W (IN.) (IN.)fl200.O 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 198.5 48 200.0 200.0 200.0 200.0 186.1 168.1 165.4 148.8 60 200.0 200.0 198.5 170.1 148.8 134.5 132.3 119.1 72 200.0 196.6 163.8 140.4 122.9 111.0 109.2 98.3 14 154.7 123.8 103.2 88.4 77.4 69.9 68.8 61.9 96 138.2 103.7 82.9 69.1 59.2 SL8 46.8 46.1 41.5 _108 97.1 72.8 58.2 45.5 41.6 36.4 32.9 32.4 29.1 QUALIFIED ANCHOR CLIPS 0 0 0 0 0 0 0 0 2" X 4" X 3 3/8" L-CLIP ALUMINUM 6063-T6 .*MUST BE USED IN PAIRS 0 0 0 O 0 0 0 0 81/4" X 3 3/8" H-CLIP ALUMINUM 6063-T6 NOTE: SEE SHEET 3 FOR SPECIFIC CLIP TYPES AND DIMENSIONS. MULLION MULLION ONE-WAY MULLION DIAGRAMS ALUMINUM 6005-T5 TRIBUTARY WIDTH = W1+W2 2 TWO-WAY MULLION DIAGRAMS TAR] F NnTFS- SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES. SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS & CLIP DETAILS. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. ANCHOR REQUIREMENTS: • WOOD: #14 WOOD SCREWS • CMU: 1/4" ITW TAPCONS • CONCRETE: 1/4" ITW TAPCONS • METAL• 1/4" SELF -DRILLING SCREWS (GRADE 5) INSTALLATION SUBSTRATES: • WOOD ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/2" & EDGE DISTANCE OF 1". WOOD SHALL BE MIN. S.G: 0.55. • HOLLOW CMU ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/4" & EDGE DISTANCE OF 2-1/2". HOLLOW CMU SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. • CONCRETE ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-3/4" & EDGE DISTANCE OF 2-1/2". CONCRETE SHALL BE MIN.4000 PSI. • METAL ANCHORS SHALL HAVE A MIN. (3) THREADS PENETRATION BEYOND METAL STRUCTURE. STEEL SHALL BE MIN. 18 GA. (0.045" THICK) 33 KSI YIELD. ALUMINUM SHALL BE MIN.1/8" THICK ALUMINUM 6063-T5. C �\• E,.g •• '� O * N 7 * = o S A OF G �30 P �` O l0 :G �/ soe �� n -Fig B�µ�, rmE Dmv�uR ]4STe REVISIONSADMSMOF ry BAsiERNMONOECRIRALSYSTPuv ilsterJfl` �+N �Tw'ti�Y ■ p�w:'w.nou..o w..a anon. ff DOMESf 932 yyCA� "ro vrr�v� S3RMI. TD E HVHZ CLIPPED ALUMINUM TUBE MULLIONS VERTICAL AND HORIZONTAL CONFIGURATIONS 1"x4"MULLION GATE 02 05 13 ORAN9I BY: TJH PREPARED BY: BONDING DROPS, ING FOPECEMFICATEOF AUMOWAT10NNO.1998 oRAwwGNa PA-0003 sNEfT: 8 OF 11 scuE N.T.S. REV: - Br OATB oEscwPnoN REv DESIGN PRESSURE LIMITS FOR MU W ON: 2" x 4" - ONE-WAY MU W ONS 5PAN'U TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 188.0 196.8 180.1 84 2000. 200.0 195.1 166.4 146.6 132.5 123.5 122.2 114.8 96 200.0 159.0 129.1 109.5 95.9 85.9 79.5 78.5 73.0 108 146.7 111.1 1 89.9 76.0 66.2 59.1 1 54.4 53.7 49.5 DESIGN PRESSURE LIMITS FOR MUWON: 2" x 4" -TWO-WAY MU W ONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.125 54 60 24 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 60 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 72 200.0 200.0 200.0 175.1 150.1 231.3 118.7 116.7 105.1 84 200.0 200.0 180.1 150.1 128.7 112.6 201.7 100.1 90.1 96 200.0 155.1 124.1 103.4 88.6 77.6 70.1 68.9 62.0 108 145.2 108.9 87.1 72.6 62.2 i 54.5 1 49.2 48.4 1 43.6 ALUMINUM 6005-T5 F IBUTARYWIDTH= W1+W2 2 f '-1 �I( MULLION MULLION - ONE -WAY MULLION DIAGRAMS TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES. SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS & CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CLIP DIMENSIONS. 5. ANCHOR REQUIREMENTS: • WOOD: #14 WOOD SCREWS CM QUALIFIED ANCHOR CLIPS CO14"IATWTAPCONS • METAL: 1/4" SELF -DRILLING SCREWS (GRADE 5) 6. INSTALLATION SUBSTRATES: • WOOD ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/2" & EDGE DISTANCE OF 1". WOOD SHALL BE MIN. S.G: 0.55. • HOLLOW CMU ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/4" & EDGE DISTANCE OF 2-1/2". HOLLOW CMU SHALL 0 0 0 0 BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. • CONCRETE ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-3/4" & EDGE DISTANCE OF 2-1/2". CONCRETE SHALL BE MIN.4000 PSI. • METAL ANCHORS SHALL HAVE A MIN. (3) THREADS PENETRATION BEYOND METAL STRUCTURE. STEEL SHALL BE MIN. 18 GA. (0.045" THICK) 33 KSI YIELD. ALUMINUM SHALL BE MIN. 1/8"THICK ALUMINUM 6063-T5. 0 0 0 0 2" X 4" X 3 3/8" L-CLIP ALUMINUM 6063-T6 **MUST `�� 7j77i/ REVISIONS ��- EASnTN ARnN1O51MUR srs�SLs NOF O //�/ Eastern EA9TERN MAL SYPPLY BE USED IN PAIRS ,��� C• :..�... n' u:w 16WM.FESIICAVE \\ • • C••V •• I� a 912 � ,u:�.�.a:'•w�..�:: �77� 2180 CLIPPED ALUMINUM TUBE MULLIONS : * o HVHNOTE: SEE SHEET 3 FOR SPECIFIC CLIP VERTICAL AND HORIZONTAL CONFIGURATIONS VERTICAL S A' OF Q TYPES AND DIMENSIONS. <U� 2" x 4" MULLION %�Dn w1e oBAwN n: PREDMFD ev: O lOP :'• 02 OS 13 T1H BUILDING DROPS, INC DNAWINONO: 6CALE FBPECEROFICAIEOF age eEADH PA-0003 N.T.S. A OROATION NO.29578 SHEET. FIEV: BP FE G' 1 W nON ND 20.578 F °"� DESCRIP1xNi �' 9 OF 11 - DESIGN PRESSURE LIMITS FOR MULLION: 2" x 6" - ONE-WAY MU W ONS SPAN 'L' TRIBUTARY WIDTH'W (IN.) (IN.) 18 24' 30 36 42 48 53.125 54 60 24 200.0 1 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 36 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 48 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 72 200.0 200.0 200.0 200.0 200.0 197.0 18B.0 186.8 180.1 84 200.0 200.0 200.0 191.0 171.5 157.6 148.7 147.5 140.1 96 200.0 211 186.8 161.6 144.1 131.3 123.0 121.8 114.6 108 200,0 197.0 162.7 140.1 124.2 1116 104.9 103.8 97.0 DESIGN PRESSURE LIMITS FOR MULLION: 2" x 6"-TWO-WAY MULUONS SPAN'L' TRIBUTARY WIDTH'W' (IN.) (IN.) 18 24 30 36 42 48 53.1251 54 60 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 197.0 178.0 175.1 157.6 200.0 200.0 200.0 200.0 180.1 157.6 142.4 140.1 126.1 N36 200.0 200.0 200.0 175.1 150.1 131.3 118.7 116.7 105.1 200.0 200.0 190.1 150.1 128.7 112.6 101.7 100.1 90.1 200.0 197.0 157.6 131.3 112.6 98.5 89.0 87.6 78.8 z00.0 17s.1 140.1 116.7 100.1 87.6 79.1 77.8 70.0 QUALIFIED ANCHOR CLIPS 0 0 0 0 0 0 0 0 2" X 4" X 5 3/8" L-CLIP ALUMINUM 6063-T6 '•MUST BE USED IN PAIRS NOTE: SEE SHEET 3 FOR SPECIFIC CLIP TYPES AND DIMENSIONS. 0.250" I 2.000" 6.000" MULLION MULLION - ONE -WAY MULLION DIAGRAMS 2" X 6"MULLION ALUMINUM 6005-TS TRIBUTARY WIDTH = Wl+ W2 2 TWO-WAY MULLION DIAGRAMS TABLE NOTES: 1. SEE SHEET 1 FOR INSTRUCTIONS ON USING TABLES. SEE SHEETS 4 AND 5 FOR TYPICAL INSTALLATION METHODS & CLIP DETAILS. 2. LINEAR INTERPOLATION BETWEEN LISTED WIDTHS AND SPANS IS ALLOWED. 3. SEE THIS SHEET FOR SPECIFIC MULLION DIMENSIONS. 4. SEE SHEET 3 FOR SPECIFIC CUP DIMENSIONS. S. ANCHOR REQUIREMENTS: • WOOD: #14 WOOD SCREWS • CMU:1/4" ITW TAPCONS . CONCRETE:1/4" ITW TAPCONS • METAL: 2/4" SELF -DRILLING SCREWS (GRADE 5) 6. INSTALLATION SUBSTRATES: • WOOD ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/2" & EDGE DISTANCE OF 1". WOOD SHALL BE MIN. S.G: 0.55. • HOLLOW CMU ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-1/4" & EDGE DISTANCE OF 2-1/21'. HOLLOW CIVIL SHALL BE MEDIUM WEIGHT CONFORMING TO ASTM C 90. • CONCRETE ANCHORS SHALL HAVE A MIN. EMBEDMENT OF 1-3/4" & EDGE DISTANCE OF 2-1/2". CONCRETE SHALL BE MIN. 4000 PSI. • METAL ANCHORS SHALL HAVE A MIN. (3) THREADS PENETRATION BEYOND METAL STRUCTURE. STEEL SHALL BE MIN.18 GA. (0.045" THICK) 33 KSI YIELD. ALUMINUM SHALL BE MIN.1/8" THICK ALUMINUM 6063-T5. / REVISIONS �- ewsrenN ANCNMTunu sra,ots E .. O f rEastern,ENN,���r � c� �i � � 389a3ooenancAvr. " � � ��• E••U •• �O � .;f .ua. w....,ow. �..., e...."- RM1rERi. R3391] * HVHZ CLIPPED ALUMINUM TUBE MULLIONS O S A VERTICALAND HORIZONTAL CONFIGURATIONS OF Q 2"x6"MULLION :��T O IOp'.•'� t2t/ � OAre: oaAwNer: aNErAHmer: o�w02N05 13TJH is BFlirUNPxGORORS NC ��� - PA-0003 N.T.S. AUH,Oe nONNNo 29M 398 � M. sH�3: REV: caaE emT. a na Na some o er wn: fU°"0N "� 10 OF 11 - EXAMPLES OF TWO-WAY MULLION ASSEMBLIES EXAMPLES OF ONE-WAY MULLION ASSEMBLIES II�/JJII!1�/J�l!II�iJJII INJIMM 14 r- ------ I .. r '10 �fKf iiiiiiiiiiii=iiiiiiiiiiil �1//Now.,00-1. 1My, /111/////10 iiii� (� iiii ► iiii �/. .di i/� /11/� /li// /i1// 11I MULL '// /11// /��// /11/ /1 WLJi1!///1�///�1///1 //1lU /III/ !/ /ICl/ /ICl/ RULLE! HE HORIZONTAL MULLION HORIZONTAL • TRANSOMOVER i//'j��/j /--------------------------- �1/1/j �ji iiiiiiiiiiill��JJiii ���111SPANW I' � •'//11/j 111 j VERTICAL MULLION HINGED DOOR W/SIDELITE 1. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND CONFIGURATIONS NOT SPEC FICALLY SHOWN MAY BE EXTRAPOLATEDFROM , CONFIGURATION VALUES. 2. IF THE LOADING TYPE CANNOT BE DETERMINED, USE TWO-WAY ASSEMBLY .• . •` , PRODUCTS3. FENESTRATION . AS .•.