APPROVED, Design Pressure Report
Property Information Owner:PERRELL, EDGAR Address:7501 KENWOOD RD. FORT PIERCE, FL. 34951 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:50 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 35.75 49.5 7 37.3 -40.5 2 Int 35.75 49.5 7 37.3 -40.5 3 Int 35.75 25 7 37.8 -41.0 4 End 35.5 37.25 7 37.8 -50.6 5 End 35.75 49.5 7 37.3 -49.6 6 Int 36 36.5 7 37.8 -41.0 7 Int 71.5 79.5 7 34.4 -37.6 8 End 71.5 79.5 7 34.4 -43.9 9 End 35.75 25 7 37.8 -50.6 10 End 35.75 25 7 37.8 -50.6 11 End 25 24.75 7 37.8 -50.6 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1