Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutAPPROVED, Design Pressure ReportProperty Information
Owner:PERRELL, EDGAR
Address:7501 KENWOOD RD.
FORT PIERCE, FL. 34951
Building Information
Wind Zone:170 MPH.
Exposure Category:C
Minimum Building Dimension:50 ft.
Mean Roof Height:15 ft.
Risk Category:II
Design Pressure Calculations
Opening
Number
Location
Zone
Device
Width (in)
Device
Height (in)
Device
Elevation (ft)
Max Positive
Pressure (psf)
Max Negative
Pressure (psf)
1 Int 35.75 49.5 7 37.3 -40.5
2 Int 35.75 49.5 7 37.3 -40.5
3 Int 35.75 25 7 37.8 -41.0
4 End 35.5 37.25 7 37.8 -50.6
5 End 35.75 49.5 7 37.3 -49.6
6 Int 36 36.5 7 37.8 -41.0
7 Int 71.5 79.5 7 34.4 -37.6
8 End 71.5 79.5 7 34.4 -43.9
9 End 35.75 25 7 37.8 -50.6
10 End 35.75 25 7 37.8 -50.6
11 End 25 24.75 7 37.8 -50.6
Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code.