HomeMy WebLinkAboutIn- Place Density Test ReportA Universal
Engineering
Sciences
Company
4TFRNAT\QOP
UES Project No: 3315.2000020.0000
Workorder No: 248993-1
Report Date: 10/19/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: Century Complete Homes UES Technician: Mark Rogers
1155 Malabar Road, NE Suite 8 Date Tested: 10/18/2021
Palm Bay, FL 32907
Project: Century Complete Saint Lucie County
Various Locations, Port St. Lucie, St. Lucie County County, FL
Type of Test:
Area Tested: 7106 Paso Robles Blvd, Ft Pierce
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
'
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
110.2
11.1
107.2
10.5
97
Pass
2
Southwest corner of lot
0-1 ft
110.2
11.1
109.6
10.9
99
Pass
3
Center of lot
0-1 ft
110.2
11.1
108.0
10.6
98
Pass
Remarks: Permit:2012-0293
aECONSD
F p 9 zal
at, Lucie�co g W
pefm
Reviewed By
GFA International, Inc
FBPE Registry No.4930
s0'1 ' Digitally signed
e... A .sy
: P ��OENSF.., by Allan
No. 99 p`
+_ A,;bubakar
Date:-2021.10.19
13:10:14'-04'00'
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G.
Abubakar, P.E. on the date adjacent to the seal. Printed copies of
this document are not considered signed and sealed and the
signature must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
2 n
--
y
pIS TESTING•
•
UES Project No: 3315.2000020.0000
Workorder No: 248994-1
Report Date: 10/19/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: Century Complete Homes UES Technician: Mark Rogers
1155 Malabar Road, NE Suite 8 Date Tested: 10/18/2021
Palm Bay, FL 32907
Project: Century Complete Saint Lucie County
Various Locations, Port St. Lucie, St. Lucie County County, FL
Type of Test:
Area Tested: 7100 Coquina Ave, Ft Pierce
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
110.2
11.1
107.5
10.8
98
Pass
2
Southwest corner of lot
0-1 ft
110.2
11.1
108.4
11.0
98
Pass
3
Center of lot
0-1 ft
110.2
11.1
108.4
10.6
98
Pass
Remarks: Permit:2012-0339
RECEIVED
FEB 0 9 2022
sle County
t. aeGmitting
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Digitally signed
yP.:�`�EN3Fg9'i, (by
Allan
No. 99 ' *_
Abubakar
`—Date::2021.10.19
13:09:33 -04 00
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G.
Abubakar, P.E. on the date adjacent to the seal. Printed copies of
this document are not considered signed and sealed and the
signature must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
c
2
y
02 - -
U�
9`S STING •\N`'Q�
UES Project No: 3315.2000020.0000
Workorder No: 248298-1
Report Date: 10/11/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: Century Complete Homes
1155 Malabar Road, NE Suite 8
Palm Bay, FL 32907
Project: Century Complete Saint Lucie County
Various Locations, Port St. Lucie, St. Lucie County, FL
Area Tested: 7202 Deer Park Ave, Lakewood Park
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
UES Technician: Mark Rogers
Date Tested: 10/07/2021
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of pad
0-1 ft
110.2
11.1
107.5
10.7
98
Pass
2
Southwest corner of pad
0-1 ft
110.2
11.1
107.6
10.3
98
Pass
3
Center of pad
0-1 ft
110.2
11.1
106.0
' 10.4
96
Pass
Remarks: Permit:2103-0364
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Digitally signed
by Allan
1 Qt No. 99 ?�a
i * Abubakar
R��P —Date:-2021.10.11
,p.............
.1 ,Olml„°° 13:44:59-04'00'
•„dNP
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G. Abubakar,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
2 o�M�taTn� • GFOTFcyo
w e -
o=Sciences
9CS �tSTING Company•`
UES Project No: 3315.2000020.0000
Workorder No: 249945-1
Report Date: 10/29/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: Century Complete Homes UES Technician: Mark Rogers
1155 Malabar Road, NE Suite 8 Date Tested: 10/26/2021
Palm Bay, FL 32907
Project: Century Complete Saint Lucie County
Various Locations, Port St. Lucie, St. Lucie County County, FL
Area Tested: 7409 Belleair Ave, Ft Pierce
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
110.2
11.1
106.7
10.6
97
Pass
2
Southwest corner of lot
0-1 ft
110.2
11.1
108.2
10.9
98
Pass
3
Center of lot
0-1 ft
110.2
11.1
109.1
10.4
99
Pass
Remarks: Permit # 2103-0388
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Digitally signed
by Allan
Abubakar
�fJae: 2021.10.29
16:52:14-04'00'
Allan G. Abubakar, P.E.
STATE OF FLORIDA
Professional Engineer No. 69952
This item has been digitally signed and sealed by Allan G. Abubakar,
P.E. on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1