Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED CGCI-FL26048_R2_II_SS-3520-FPA-REV-A
GENERAL NOTES: SS-3520 IMPACT -RESISTANT STOREFRONT WINDOW SYSTEM GENERAL NOTES: 3. 4. 5. 6 7 61 THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). SHUTTERS ARE NOT REQUIRED PER FBC REQUIREMENTS, WHEN USED IN WIND-BORNE DEBRIS REGIONS. GLAZING: SEE GLAZING DETAILS ON SHEET 6 & GLAZING TYPES ON SHEET 8. DESIGN PRESSURES: A) NEGATIVE DESIGN LOADS BASED ON STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM El300. B) POSITIVE DESIGN LOADS BASED ON WATER INFILTRATION, STRUCTURAL & CYCLE TESTING AND GLASS PER ASTM E1300. C) DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD. THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33-1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. INSTALLATION SCREWS & FRAME CORNERS TO BE SEALED WITH NARROW JOINT SEALANT. DISSIMILAR MATERIALS THAT COME INTO CONTACT, INCLUDING PRODUCT FRAMING, ANCHORAGE AND OPENING SUBSTRATES, SHALL BE COATED OR PROTECTED TO PREVENT CORROSIVE REACTIONS AS REQUIRED BY THE FLORIDA BUILDING CODE. REFERENCES: ELCO ULTRACON & CRETEFLEX NOA'S, ITW TAPCON NOA ANCHOR NOTES: 2. 3. 4. 5. FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADE COUNTY APPROVED ELCO ANCHORS. SEE TABLE 1 ON THIS SHEET FOR EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS. FOR SUBSTRATE APPLICATIONS SEE TABLE 1 ON THIS SHEET. WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. PROPERLY SECURED, 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD & TO BE REVIEWED BY THE BUILDING OFFICIAL. SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE. USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. INSTRUCTIONS: 1. DETERMINE THE BUILDING'S REQUIRED DESIGN PRESSURE USING THE ASCE 7 STANDARD. THE PRODUCT'S DESIGN PRESSURE MUST MEET OR EXCEED THIS VALUE. 2. DETERMINE THE ANCHOR TYPE FROM TABLE 1, SHEET 1. 3. DETERMINE THE GLASS DESIGN PRESSURE FROM TABLE 2. 4. MID -PANEL ANCHOR QUANTITIES ARE GIVEN IN TABLES 7 & 8 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. 5. IF THE STOREFRONT WINDOW IS ATTACHED TO ANOTHER WINDOW THROUGH A COMMON MULLION: A) DETERMINE THE MULLION DESIGN PRESSURE FROM TABLE 9. B) DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO MULLION CLUSTER ANCHORAGE FROM TABLES 3 OR 4 BASED ON YOUR SHIM SPACE, ANCHOR TYPE AND THE QUANTITY OF ANCHORS. 6. IF THE JAMBS ARE ANCHORED TO THE SUBSTRATE: A) THE SPACING IS GIVEN IN TABLES 5 & 6 AND HAVE BEEN CALCULATED FOR THE PRODUCT'S MAXIMUM DP. IF THE JAMBS ARE ANCHORLESS: A) DETERMINE THE MAXIMUM DESIGN PRESSURE DUE TO CLUSTER ANCHORAGE FROM TABLES 3 OR 4 BASED ON YOUR SHIM SPACE, ANCHOR TYPE AND THE QUANTITY OF ANCHORS. B) DETERMINE THE JAMB DESIGN PRESSURE FROM TABLE 9. 7. THE LOWEST DESIGN PRESSURE FROM ALL TABLES REFERENCED ABOVE, SHALL BE USED FOR THE ENTIRE ASSEMBLY. 8. IF COMBINED WITH A COMPATIBLE STOREFRONT ENTRANCE DOOR, THE LESSER DESIGN PRESSURE OF THE DOOR OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. FLORIDA PRODUCT APPROVAL # 26048 TABLE 1: IMPACT RATING RATED FOR LARGE & SMALL MISSILE IMPACT RESISTANCE Min. Edge Min. Min. O.C. Group Anchor Substrate Distance Embedment Distance P.T. Southern Pine (SG=0.55) 1" 1-3/8" T. Aluminum, 6063-T5" #14 Steel or (0.125" min. thickness) 3/8" 1/8" 5/8" A 410 SS SMS (G5) Steel, A36* (0.125" min. thickness) 3/8" 1/8" 5/8" Steel Stud, A653 (0.045" min. thickness) 3/8" .045" 5/8" Concrete (min. 2.85 ksi) 2-1/2" 1-3/81, 3" Grout -Filled CMU, 1/4" Elco Ultracon (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2 1/2 1 1/4" 6" Concrete (min. 3.00 ksi) 2-112 1-3/4" 3" Concrete B 1/4" DeWalt (min. 3.00 ksi) 2-112" 1-3/8" 4" Ultracon+ Grout -Filled CMU, (ASTM C-90) 2-1/2" 1-3/4" 4" Ungrouted CMU, (ASTM C-90) 2-1/2" 1-1/4" 3" 1/4" Elco 410 S.S. Ungrouted CMU, CreteFlex (ASTM C-90) 2 1/2" 1 1/4" 6" Ungrouted CMU, 5/16" Elco Ultracon (ASTM C-90) 3 1/8" 1-1/4" U. 1/4" Elco 410 Concrete S.S. CreteFlex (min. 3.35 ksi) 2-1/2 1-3/4" 3" Concrete C (min. 3.52 ksi) 3-1/8" 2" Y 5/16" Elco Ultracon Grout -Filled CMU, (ASTM C-90) 2 1/2 2 1/4" 5" Concrete 3/8" Large Diameter (min. 3 ksi) 3" 1-1/2" 4" D ITW Tapcon Ungrouted CMU, (ASTM C-90) 3" 1-1/2" 6" THIS SYSTEM HAS BEEN TESTED TO MEET THE 400 FT -LB KINETIC ENERGY IMPACT LOADING REQUIREMENTS OF ANSI Z97.1. CONTENTS: * MIN. OF 3 THREADS BEYOND THE METAL SUBSTRATE.METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. "UNGROUTED CMU" VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. ALL ANCHOR HEAD TYPES ARE ALLOWED GENERAL NOTES, INSTRUCTIONS ...................................... 1 ANCHOR TYPES, TABLE 1.....................................................1 ELEVATIONS........................................................................... 2, 3 5" HORIZ. SECTIONS.............................................................. 4 7" HORIZ. SECTIONS.............................................................. 5 VERT. SECTIONS....................................................................6 INSERTS...................................................................................7 GLASS DP, TABLE 2 & GLAZING TYPES...............................8 MULLION ANCHOR CLUSTER DP - 1/4" SHIM, TABLE 3......9 MULLION ANCHOR CLUSTER DP - 1/2" SHIM, TABLE 4......10 JAMB ANCHOR SPACING - 1/4" SHIM, TABLE 5...................11 JAMB ANCHOR SPACING - 1/2" SHIM, TABLE 6...................12 MID -PANEL ANCHOR QUANTIY - 1/4" SHIM, TABLE 7.........13 MID -PANEL ANCHOR QUANTIY - 1/2" SHIM, TABLE 8.........14 VERTICAL MULLION DP, TABLE 9.........................................15 EXTRUSION PROFILES.......................................................... 16 CORNER DETAILS.................................................................. 16 PARTS LIST, TABLE 10........................................................... 16 -,I42 Cd 0 U •� z_ Flo CU 0 o o Uj CJ W a,3 zoo, t ¢ ;o O i U M = COC ® OQOLL� z� wLC QC U z Y z_ O H 00 OU 0 W W =xsza C7 O W CY U O } O J w w0 z o w 20 CD J U U O Q ('14 + Lo Z O U C:) Q J Cn D 0,- 0 O LU = � U Q Q uoudussaa no7 XO T O (D /O _ U v z c Q C'6 L U) LL] c u O Z 00 CV O O J Q 1 J 0- ILL O W M U) W F-- 'ON Cn qmu U) , r O O 0 I_ >z r ZO aZ 0-1LL O CV LLI Lr) 0-1 co O Cn F_ U) U) \\111141ifll/// �•`` pN`� LYNN�j'�',, * No.58705 � 912 2I2��� STATE OF CU \ .FLOR10 G\�� A. LYNN MILLER, P.E. P.E.# 58705 0 MAX. O.C. DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 14-3/8" 24" MAX. END DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 12-7/8" 24" 180" MAX. A S FRAME 4 5 HEIGHT SEE O.C. SPACING ON TABLES 5 & 6 1 6" MAX. SEE TABLES 7 SEE TABLES &8FOR 3&4FOR MID -PANEL CLUSTER ANCHOR ANCHOR QUANTITY QUANTITIES I SEE TABLES SEE TABLES SEE TABLES & 8 FOR 3 & 4 FOR & 8 FOR MID -PANEL CLUSTER MID -PANEL ANCHOR ANCHOR ANCHOR QUANTITY QUANTITIES QUANTITY 1- I I I --- 1---- -L I I I 7 SEE STOREFRONT DOOR APPROVALFOR SPECIFICATIONS A REINFORCEMENT SEE TABLE 9 / B T 4 5 / B -- --- 1/4" NUT & BOLT, SEE SHEETS 4 & 5 / / -- -- -- --- / G E / 6 4 I I MULTIPLE HORIZONTAL MULLIONS ALLOWED, 60" MAX. LENGTH / / D 4 --- -- --- I I I I 3-1/2" MAX. 6 L__-Di Ll_ � -1_ 1_1 _1-1 SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR MID -PANEL CLUSTER MID -PANEL CLUSTER ANCHOR ANCHOR ANCHOR ANCHOR QUANTITY QUANTITIES QUANTITY QUANTITIES NOTES: 1. IF COMBINED WITH A COMPATIBLE STOREFRONT ENTRANCE DOOR, THE LESSER DESIGN PRESSURE VALUE OF THE DOOR OR THE WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. SEE SHEET 8 FOR DAYLIGHT OPENING (DLO) FORMULAS. -------------- --- ----------- I / I / I I I---------------- -F--------------- r I I I I I I I I / I I I L F------------ ATTACHED COMPATIBLE STOREFRONT DOOR & TRANSOM, SEE SEPARATE APPROVALFOR SPECIFICATIONS ------------- ---------- SEE TABLES 7 SEE & 8 FOR STOREFRONT MID -PANEL DOOR ANCHOR APPROVALFOR QUANTITY SPECIFICATIONS TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF HORIZONTAL MULLION & STOREFRONT DOOR 180" MAX. FRAME HEIGHT (DOOR MAY LIMIT MAX HEIGHT, SEE SEPARATE APPROVAL) O CIy (j •-q z � a u O O p v w 2 Ot U ago M ` UQ U)= M 0�LL� ® Op6LLco = co LU >_ � O J co O O w o J CO �;� z�m zp J } � Q � V M J m z LL p = of w U U w IL H LU O > LL o Z L) ?YU' C) Z NOOK Opwof =xsZLL Ucow O -1LL pzww U§!=a �O (� U U aoi}auosaQ 'nay Y 00 U) T_ N O o T_ 07 0 0 aO J U) ' Q LLJ J_ d �e Q O IIoa( H N LL1 M U) LLJ F— 'ON U)M Na 0) T_ LL O O 0 N >z Q F— Z Z Z O alga, O O� o LL N L>U O M J F- U) w U \\�,tilillll/111 �YNN ` '. . �� ON� •!LI �' * : No. 58705 ;.4v9l*22/20 STATE OF O� �CORIDP �S .......... . ANAL ON``��. A. LYNN MILLER, P.E. P.E.# 58705 Mi MAX. O.C. DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 14-3/8" 24" MAX. END DISTANCES REINFORCED & REINFORCED 5" MULLION UNREINF. 5" MULLION UNREINFORCED 7" HD MULLION 24" 12-7/8" 24" SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 USE HALF THE & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER ANCHOR MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL QUANTITY SHOWN IN ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR TABLES 3 & 4 QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY _111 PT(Til-Filirl I I I I I 111 rT 1 I� 24" MAX. A REINFORCEMENT SEE TABLE 9 24" MAX. O.C. M AM _---===ATTACHEDWINDOW, 5SEPARATE NUT & BOLT IFREINFORCEMENT IS REQUIRED, SEE SHEETS 4 & 5 B -----------OTHERS NUT & BOLT,SEE SHEETS 4 & 5 SEE TABLE 9______________SEE ---�- ATTACHEDPTAC LOUVER,SEE SEPARATEAPPROVAL FOR JREINFORCEMENT SPECIFICATIONS 7 Q�1/4" SEE4 APPROVALFOR SPECIFICATIONS1/4"REI 6" MAX.L O.C. MSPACING ON TABLES 5 & 6 7 ----- - � ---------- - ------------ -� 7 KNEEWALL BY j ---ri KI I J�_lj L--------L L--------L -J L-------L--J L--------L--J ---------L67 fUSE HALF THE SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEE TABLES 7 SEE TABLES SEETABLES7 SEETABLES3&4FOR CLUSTER ANCHOR & 8 FOR 3&4FOR & 8 FOR 3 & 4 FOR & 8 FOR 3 & 4 FOR & 8 FOR CLUSTER ANCHOR QUANTITY SHOWN INMID-PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL CLUSTER MID -PANEL QUANTITIES (SPLIT TABLES 3 & 4 ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR ANCHOR BETWEEN ADJOINING QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY QUANTITIES QUANTITY WINDOWS) TYP. ELEVATION OF ANCHORLESS JAMB NOTES: 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. SEE TABLES FOR MAXIMUM ALLOWED SIZES. 3. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY APPROVED PGT, CGI OR WINDOOR WINDOW WITH A FLANGED FRAME. 4. SEE SHEET 8 FOR DAYLIGHT OPENING (DLO) FORMULAS. 5. MULTIPLE INSERTS WITHIN THE SAME STOREFRONT WINDOW ALLOWED. TYP. ELEVATION OF STOREFRONT WINDOW SYSTEM WITH EXAMPLES OF WINDOW INSERT, PTAC INSERT & KNEEWALL 3-1/2" MAX. 6" MAX. 1 T SEE O.C. SPACING ON TABLES 5 & 6 l is • V c z 6" MAX. o i o V Oz W Ot a-,o U U a u,= M f c ® O v L c o z_ _� > c, w \ O J L c��a< Ucr�2cc 0 0 0 L LU CU J v ?YU' z;� z ow2F- z rn N O 0 J r O p W W =°,za SEE TABLES 7 Q(- &8FOR }0, QUO MID -PANEL mow aooU) ANCHOR � C) 00 z w a QUANTITY a w o Lu0> a o U Z CD j MNOJxe Q OuMoic N W M07 W'oN U)NMa U) LL O O o MzZ Z Z O 9/00S O � oLL NWO MJ � Lu U) YNNNo. 58705 4v9 �12 2 / 20STATE OFCORIOP/ONALI�\A. LYNN MILLER, P.E. P.E.# 58705 EMBEDMENT EDGE DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1. SHEET 1. CONCRETE/CMU PER ANCHOR REQUIREMENT, 2X WOOD BUCK OR WOOD FRAMING EXTERIOR 1/2" MAX. SHIM EMBEDMENT EDGE DISTANCE ' 1 ° TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. CONCRETE/CMU PER ANCHOR ° REQUIREMENT 1/2" MAX. SHIM INSTALLATION NOTES: DETAIL Al INTO MASONRY OR WOOD REQUIRED AT EACH ANCHOR LOCATION, REINFORCEMENT 10 MIN. 3" LENGTH (IF REQUIRED) 8 DAYLIGHT OPENING WIDTH 40 OPTIONAL LAMI IG GLASS 1 1X WOOD BUCKSTRIP, SEE NOTE 2. THIS SHEET. EXTERIOR IG SEE BACKBEDDING DETAILS, SHEET 6 FOR ANCHORLESS JAMBS, MUST BE CONTINUOUS FOR THE FULL HEIGHT OF THE JAMB. INSTALLATION SE BY OTHERS MOVEMENT AT GREATEST DP. DETAIL B MULLION 3 FRAME WIDTH 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8. SEE �k&© SHEET 2 TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, 7� SEE TABLE 1, SHEET 1. EXTERIOR 41 DETAIL A4 INTO METAL 1 1/2" MAX. SHIM DETAIL A3 ANCHORLESS JAMB 1/4" NUT & BOLT IF REINFORCEMENT IS REQUIRED, ?4" MAX. FROM EACH END AND 24" MAX O.C. IFORCEMENT, QUIRED 1/4" NUT & BOLT, 24" MAX. FROM TOP OF FRAME, REQUIRED FOR TRANSOM HEIGHTS OVER 22-1/4" (SEE SEPARATE APPROVAL) EXTERIOR 15 APPROVED MULLION, ALUMINUM OR STEEL FRAMING. SEE TABLE 1, SHEET 1. EDGE D IST. 1-3/8" 1 1/4" NUT & BOLT, 24" MAX. FROM EACH END AND 24" MAX O.C. (SEE SEPARATE APPROVAL) II -, I I I it ATTACHED COMPATIBLE STOREFRONT DOOR, SEE SEPARATE APPROVAL FOR SPECIFICATIONS ATTACHED COMPATIBLE STOREFRONT DOOR TRANSOM, SEE SEPARATE APPROVAL FOR SPECIFICATIONS 1111l�L-= JI1 I Ill �I I I II I I _ � L ` * No.: " v y/ STAI 40ADN A. LYNN P REJ NSF • �(�� �' ,870s r 2/20 E OF Rio 1ILLER, P.E. 58705 Q na� EMBEDMENT _� DETAIL S1 DETAIL T DETAIL S4 INTO MASONRY MULLION INTO METAL 11 OR WOOD OPTIONAL 14 OPTIONAL 13 REQUIRED AT EACH EDGE 5 ANCHOR LOCATION, REINFORCEMENT SEE *& © EDGE DISTANCE MIN. 3" LENGTH (IF REQUIRED) 10 SHEET 2 DISTANCE TYP. ANCHOR TYPE, 8 EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. uogduosaQ 'naN TYP. ANCHOR TYPE, DAYLIGHT OPENING WIDTH _ EMBEDMENT AND CD EDGE DISTANCE PER 40 OPTIONAL APPROVED MULLION, Y SUBSTRATE, SEE LAMI IG GLASS ALUMINUM OR STEEL FRAMING. Cn (� TABLE 1, SHEET 1. 40 SEE TABLE 1, SHEET 1. N co CONCRETE/CMU PER O ANCHOR REQUIREMENT, O a nN 2X WOOD BUCK OR WOOD FRAMING J Q EXTERIOR SEE BACKBEDDINGiA EXTOR 41 (n d 11 DETAILS, SHEET 6 3 J LL 1/2" MAX. SHIM 1/2" MAX. SHIM xe Q O FRAME WIDTH umoic N W L0 •�:� z C M Vo (n 7.i vi V U) °o W w'ON zlu3f �2 Z 5M EMBEDMENT 1X WOOD O o BUCKSTRIP, SEE DETAIL S3 U a` U O U) NOTE 2, THIS SHEET. ® LO o C) a `.) ANCHORLESS Z = rn LL Q cU O O a DETAIL S2 JAMB INSTALLATION NOTES: o -j M LLI Q o Q Lo THRU 1X WOOD 1. USE ONLY SUBSTRATE APPROPRIATE M v Z 1/4" NUT & BOLT IF o � aays INTO MASONRY REINFORCEMENT IS ANCHORS, FOLLOW EMBEDMENT, EDGE � j REQUIRED, DISTANCE AND SUBSTRATE REQUIREMENTS w 6 z w O >� 24" MAX. FROM EACH PER TABLE 1, SHEET 1. ANY INSTALLATION d w � o Q z o �/ z z DISTANCE aa.a EDGE END AND 24" MAX O.C. OPTION SHOWN MAY BE USED ON ANY SIDE z E o - � U `'o S + OF THE WINDOW. ALL ANCHOR HEAD TYPES z o p O 1 ARE ALLOWED. -1 N ' .6 ai wa N_ � O TYP. ANCHOR TYPE, as ¢ M EE � w 0 Q LL CV REINFORCEMENT 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK m O LL 7 o J o o W Ln ` ° 10 IF REQUIRED ARE TO BE CONSIDERED 1X INSTALLATIONS. o = of a o o co - O I EMBEDMENT AND ( ) w c� v O z w w _ EDGE DISTANCE PER 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY Q w z c> � t o w _ Cn SUBSTRATE, SEE e BE INSTALLED DIRECTLY TO SUBSTRATE. W o j U TABLE 1, SHEET 1. FOR ANCHORLESS JAMBS, WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" a z 1 a/JN ssaQ sauaS MUST BE CONTINUOUS FOR THE THICK OR GREATER. 1X AND 2X BUCKS aad a FULL HEIGHT OF THE JAMB. (WHEN USED) SHALL BE DESIGNED TO CONCRETE/CMU PROPERLY TRANSFER LOADS TO THE ��� Nei LYN/v PER ANCHOR STRUCTURE. WOOD BUCK DESIGN AND ,�� 0 • .. , • REQUIREMENT INSTALLATION IS THE RESPONSIBILITY OF \ �` F EXTERIOR �'t�. ' CENS i THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS �' v REQUIRED BY TABLES 3-8. * No. 58705 1/2" MAX. SHIM INSTALLATION SEALANT AND DETAILS BY OTHERS TO ACCOMMODATE 9I22I20` MOVEMENT AT GREATEST DP. '. STATE OF O� �CORIDP �S .......... . ANAL A. LYNN MILLER, P.E. P.E.# 58705 n DETAIL F1 THRU 1X WOOD CONCRETE/CMU PER INTO MASONRY ANCHOR REQUIREMENT 1X WOOD BUCKSTRIP, SEE EDGE NOTE 2, THIS SHEET. DISTANCE m v ° 1/2" MAX. V--m,„m a DAYLIGHT OPENING HEIGHT 40 � 30 FRAME HEIGHT 4 42 OPTIONAL EXTERIOR LAMI IG aGLASS SEE BACKBEDDING DETAILS, THIS SHEET 41 �)31 DETAIL F2 INTO WOOD 2X WOOD BUCKSTRIP OR FRAMING, SEE ANCHOR NOTE 3, SHEET 1 EMBEDMENT \ a � � 1/2" MAX. n EXTERIOR a TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. 02 60" MAX. HORIZ. MULLION LENGTH DETAIL G HORIZ. MULLION TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. aREQUIRED AT EACH ANCHOR LOCATION, MIN. 3" LENGTH 1/2" MAX. SHIM p EMBEDMENT p d o Q IV I o .. CONCRETE/CMU PER EDGE ANCHOR REQUIREMENT DISTANCE DETAIL H INTO MASONRY DETAIL F3 INTO MASONRY CONCRETE/CMU PER ANCHOR _ EDGE _ EDGE REQUIREMENT DISTANCE DISTANCE o v" EMBEDMENT • _ EMBEDMENT v p v v v 1 1/2" 1/2" J MAX. MAX. EXTERIOR a TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1. SHEET 1. INSTALLATION NOTES: 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, FOLLOW EMBEDMENT, EDGE DISTANCE AND SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 3-8. Glass Types 1 9/16" Lami.: 1/4" HS, .090" PVB, 1/4" HS 2 9/16" Lami.: 1/4" HS, .090" SG, 1/4" HS 3 1-1/4" Lami. IG: 1/4" HS, .090" PVB, 1/4" HS, 7/16" Airspace, 1/4" Temp. 4 1-1/4" Lami. IG: 1/4" HS, .090" SG, 1/4" HS, 7/16" Airspace, 1/4" Temp. 1) PVB & SG INTERLAYERS BY KURARAY AMERICA, INC. 2) GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED SIZES. a TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. GLAZING DETAILS APPLY BACKBEDDING ALONG ENTIRE PERIMETER 42 FOR ALL GLASS TYPES 1 3/4" GLASS 41 EXTERIOR BITE SEE GLAZING NOTE BELOW 42 APPLY BACKBEDDING ALONG ENTIRE PERIMETER 42 FOR ALL GLASS TYPES i 3/4" GLASS 41 EXTERIOR BITE a 31 SEE GLAZING NOTE BELOW(2 DETAIL F4 INTO METAL APPROVED MULLION, ALUMINUM OR STEEL FRAMING. SEE TABLE 1, SHEET 1. GLAZING NOTE: FOR GLASS TYPES 1 & 3: APPLY BACKBEDDING ALONG ENTIRE PERIMETER FOR GLASS TYPES 2 & 4: APPLY BACKBEDDING ALONG 20" FROM EACH CORNER 40 EDGE _ DISTANCE TYP. ANCHOR TYPE, EMBEDMENT AND EDGE DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. F-4 1 4 Cl 1 0 Ci • .• •q : = z o v) d � 00 0 W ow +, z of O U M = M C ® O7 LL O o z_ _'c w O J � Ur�2� Of CU -1 v ?YC� , Qz �W>NC6 _� o� 1 z rn 0 00 }iiOOpwO ¢0 za m z LL } 0 —1LL o=w aZWW LU i ¢2 ova~a' W�> �2o a- F 2 U �`CE ` * No.: "449-111 / STAI 40 A. LYNN P P.EJ uogauDsaQ 'nay Y co U) N O o U) 0 C aO U) GJ Q W G7 Q J_ d �e Q O LIMDJ� I— N W M LLl F— 'ON Z (n NMa O CD LL Lu p O U) ZZ_ nry Z Z Un k J p r _U LL N 0� M LLI P- U) > 111/1// Niv NSF • �(�� �' ,870s r 2/20 All E OF 1ILLER, P.E. 58705 n DETAIL J PTACINSERT REMOVE GLAZING LEG AS REQUIRED FOR PTAC LOUVER INSTALLATION DETAIL K PTACINSERT DETAIL L PTACINSERT 40) /--� 7 2 �I' -LLI \� IL JI ,--(2 '\ REFER TO PTAC LOUVER APPROVAL FOR LOUVER I ITV INSTALLATION REQUIREMENTS I II 2 PTAC LOUVER, REFER TO SEPARATE APPROVAL FOR -ALLATION REQUIREMENTS EDGE DISTANCE PTAC LOUVER & WINDOW INSERT NOTES: EMBEDMENT 1. REFER TO SEPARATE WINDOW APPROVAL FOR ALL WINDOW INSERT REQUIREMENTS AND INSTALLATION. 2. AWNING WINDOW INSERT SHOWN BUT MAY BE ANY 1/2" MAX. j DETAIL N APPROVED PGT, CGI OR WINDOOR WINDOW WITH A FLANGED FRAME. SHIM WINDOW INSERT II G 3. REFER TO PTAC LOUVER APPROVAL FOR ALL PTAC LOUVER REQUIREMENTS AND INSTALLATION. `---` 4. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW "-------- 5- I q SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. PGT, CGI OR WINDOOR FLANGED WINDOW (AWNING INSTALLATION NOTES: SHOWN), REFER TO SEPARATE I I 1. USE ONLY SUBSTRATE APPROPRIATE ANCHORS, APPROVAL FOR INSTALLATION ��' ; •I FOLLOW EMBEDMENT, EDGE DISTANCE AND fi REQUIREMENTS SUBSTRATE REQUIREMENTS PER TABLE 1, SHEET 1. ANY INSTALLATION OPTION SHOWN MAY BE I�L� -----r---� ry USED ON ANY SIDE OF THE WINDOW. ALL ANCHOR ;% HEAD TYPES ARE ALLOWED. 2. ALL WOOD BUCKS LESS THAN 1-1/2" THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL. UNIT MAY BE INSTALLED DIRECTLY TO SUBSTRATE. WOOD BUCKS EXTERIOR DETAIL O AAX. SHIM DEPICTED AS 2X ARE 1-1/2" THICK OR GREATER. 1X WINDOW INSERT AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE 2 2 STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE v1ENT ENGINEER OR ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE AS REQUIRED BY TABLES 40 7 3-8, SHEETS 5-10. ----{ 1.000" �, _-;-------------------------- ====1 - r ------------------------ ---------------- REMOVE GLAZING LEG AS REQUIRED FOR PTAC LOUVER INSTALLATION EXTERIOR DETAIL M PTACINSERT *SEE ©& SHEET 2 --.—{ 1.000" �--- PGT, CGI OR WINDOOR FLANGED WINDOW (AWNING SHOWN), REFER TO SEPARATE APPROVAL FOR INSTALLATION REQUIREMENTS _5---r--r----�P 1 5�i JL-- ---A -�I I ;ll--- - f------ � i DETAIL P REMOVE GLAZING LEG �-- WINDOW INSERT @ WINDOW INSERT DETAIL Q WINDOW INSERT al ts •I z � a u o p v p W z°° t moo O ¢ U M U. > H J ® Q� ILL L 1 Z SQL w O J � UcoX: O O CU J v ?YUI QZI w NO C H ' zwmNO0�` }p L0 �Upwa . J(DN Za 1 m 0 LL } 0 -1L p = ui EL ¢Luz a - IL W O ; o a F Z \\�11 ukV L ` * No.: STAI Of 40 A. LYNN P P.EJ I uogauDsaQ nay Y CEO j M N O M U) O CC a�D� J Q � ' Q J_ LLLL �e Q O MDJ N W M U) Ljj 'ON NMa U) CD ) S LL O ) O z J L U) ' r z Z n Q v n k W O a,DD 0 'c H LLLJ N Lo W � cM z O U) (n NSF • �(�� �' ,870s 2I210 ` E OF <(/� 1ILLER, P.E. 58705 TARI F 9- Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 48„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +70/-80 +90/-120 72" +70/-80 +90/-120 84" +70/-80 +90/-120 90" +70/-80 +90/-120 92" +70/-80 +90/-120 96" +70/-80 +90/-120 102" +90/-120 108" +90/-120 120" +90/-120 132" +90/-100 144" +90/-100 168" +60/-60.7 180" +60/-60 24" 60„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +70/-80 +90/-120 72" +70/-80 +90/-120 84" +90/-119.5 90" +90/-115.2 92" +90/-114 96" +90/-111.7 102" +90/-100 108" +90/-100 120" +90/-100 132" +70/-70 144" +70/-70 24" 72„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +70/-80 +90/-120 70" +90/-120 72" +90/-120 84" +90/-100 90" +90/-100 92" +90/-100 96" +90/-100 102" +70/-70 108" +69.3/-69.3 120" +66/-66 Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 78" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +70/-80 +90/-120 60" +68.6/-78.5 +90/-120 70" +90/-119.4 72" +90/-118.9 84" +90/-100 90" +90/-100 92" +90/-100 96" +70/-70 102" +69/-69 108" +66.8/-66.8 24" 84„ +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +69.2/-79.1 +90/-120 60" +90/-119.5 70" +90/-100 72" +90/-100 84" +90/-100 90" +70/-70 92" +70/-70 96" +70/-70 102" +67.3/-67.3 24" 90" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 54" +90/-120 60" +90/-115.2 70" +90/-100 72" +90/-100 84" +70/-70 90" +70/-70 92" +70/-70 96" +69.6/-69.6 24" 97-3/4" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +70/-80 +90/-120 60" +90/-100 70" +90/-100 72" +89/-99 84" +69.4/-69.4 24" 102" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +90/-120 54" +90/-116.1 60" +90/-100 70" +88.1 /-97.9 72" +70/-70 84" +67.3/-67.3 Max. DP due to Glass Limitations, psf Centerline Width Frame Height Glass Types 1 & 3 Glass Types 2 & 4 24" 108" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +70/-80 +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +70/-70 72" +69.3/-69.3 24" 114" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +68.6/-68.6 72" +67.5/-67.5 24" 120" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-120 54" +90/-100 60" +90/-100 70" +67.1 /-67.1 72" +66/-66 24" 126" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +70/-80 +90/-120 42" +90/-120 48" +90/-100 54" +90/-100 60" +70/-70 24" 132" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-120 48" +90/-100 54" +90/-100 60" +70/-70 24" 138" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-100 48" +90/-100 54" +65.6/-65.6 60" +70/-70 24" 144" +70/-80 +90/-120 30" +70/-80 +90/-120 36" +90/-120 42" +90/-100 48" +90/-100 54" +70/-70 60" +70/-70 24" 168" +60/-75 30" +60/-75 36" +60/-75 42" +60/-67.9 48" +60/-60.7 24" 180" +60/-75 30" +60/-75 36" +60/-75 42" +60/-67.3 48" +60/-60 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. CENTERLINE — CENTERLINE WIDTH - - DLO WIDTH DLO HEIGHT ---� DLO WIDTH DLO /HEIGHT 1 FRAME HEIGHT CENTERLINE HEIGHT FRAME HEIGHT / 1" FRAME DLO WIDTH HEIGHT DLO CENTERLINE HEIGHT // HEIGHT � FRAME WIDTH — FRAME WIDTH — 1" 9/16" LAMINATED GLASS STACK 090" PVB INTERLAYER 1/4" H EAT - STRENGTHENED GLASS GLASS TYPE 1 9/16" LAMINATED i GLASS STACK 090" SG INTERLAYER 1/4" HEAT - STRENGTHENED GLASS GLASS TYPE 2 DLO (DAYLIGHT OPENING) FORMULAS: FRAME WIDTH - 4" = DLO WIDTH FRAME HEIGHT - 4" = DLO HEIGHT CENTERLINE WIDTH - 3" = DLO WIDTH CENTERLINE HEIGHT - 3" = DLO HEIGHT CENTERLINE WIDTH - 1-1/2" = GLASS WIDTH CENTERLINE HEIGHT - 1-1/2" = GLASS HEIGHT FRAME WIDTH - 2-1/2" = GLASS WIDTH FRAME HEIGHT - 2-1/2" = GLASS HEIGHT 1-1/4" NOM. I.G. 9/16" LAMINATED GLASS STACK GLASS STACK .090" PVB INTERLAYER 1/4" HEAT - STRENGTHENED GLASS�]-7/16" AIRSPACE EXTERIOR 36-39 1/4" TEMPERED GLASS a GLASS TYPE 3 9/16" LAMINATED i GLASS STACK _ 1-1/4" NOM. I.G. GLASS STACK 090" SG INTERLAYER 1/4" HEAT - STRENGTHENED GLASS 7/16" AIRSPACE EXTERIOR 36-39 TEMPERED GLASS a GLASS TYPE 4 Glass Types 1 9116" Lami.: 114" HS, .090" PVB, 114" HIS 2 9/16" Lami.: 114" HS, .090" SG, 1/4" HIS 3 1-114" Lami- IG: 114" HS, .090" PVB, 1/4" HIS. 7116" Airspace, V4" Temp. 4 1-14' Lami. IG: 114" HS, .090" SG, V4" HIS, 7/16" Airspace, 114" Temp. 1) PVB & SG INTERLAYERS BY KURARAY AMERICA, INC. 2) GLAZING FOR ALL GLASS TYPES MEETS ASTM E1300 FOR ALL APPROVED SIZES. r4 o v) ca 0 0 H o w 0w + zOf°° t O ¢moo U M = M C ® O7 LLB 00_ Z Sc QL w O J � (71-Qc U co 0 0 Ld CU J v Z Ye , Qz �w oC6 ' > v C) Z cy rn N 0 00 � >- ri OUOwO ¢0N x°�ZIL CO 0 LL } 0 J LL L=LL aZWW LU i ¢2 ova~a' W O ; o a F Z U ` * No. 0 STAI T �s'•.!�C0 S A. LYNN P P.EJ n uogj.J3S0(j noy Y ao U) T— CV O o T— U) T— 0 ao J U)' Q LLJ J_ LL N� Q O UMDJ I— N LLI M U) LLJ F— 'ON NMa 0n W c� w � LL i 0 00 cn Z U cn cn n J ~ z z v fll p LL O LL 04 L LU LLJ Lo J 0� M i H � U) 111/111 > Nlv ,8705 2I20 ]z E OF Rio 11LLER, P.E. 58705 TABLE 3: Q FOR ANCHORLESS JAMBS CENTERLINE CENTERLINE Z a� WIDTH 1 WIDTH 2 USE ONLY HALF OF THE ANCHORS � O SPECIFIED IN TABLE 3, AND: LU AVERAGE CENTERLINE N LO CENTERLINE =WIDTH 1 O� WIDTH O Q w FOR INTERIOR MULLION CLUSTERSFRAME Lu USE THE QUANTITY OF ANCHORS HEIGHT � U r w w SPECIFIED IN TABLE 3, AND: O J AVERAGE CENTERLINE CENTERLINE Q O Q CENTERLINE = WIDTH 1 WIDTH 2 WIDTH 2 U ~ uogdia�soa noN Y ao 3" - U) T- N 1 O O SEE TABLE 1, SHEET 1 FORO.C. 0 ANCHOR MIN. O.C. SPACING, 4" MAX. SPACING, 4 MAX. O O e na J Q w cn a J_ LLLL FN Q O UMDJN N • v z C) CM o G� a U) °o LLJ W 'ON a� 5 Q U) DM O �M Ua �=M� CO � ® OoLLco z_ Q rn LL w 'n 0 O J '� - O Q O c� UrriE o o aaayS o ` U) o S v ZYU' co �L_� ou 2iz N z z rn Z�� NpO�� O 103S L O p w W = Qc9N =xsZLL Z M LL O O�, cOcnw� Q LL w mow/ (�I m Z LL R U J U LL U J L.L M U U U? w w I m O U) Q Luz U ~ LL w Q W o w L) O U o U LL Z a� N�saQ sauaN \\Illlillll//!` \� ANY LYNN�� i ��� �r�ENSF •!�� % \ / i �. _ * : No. 58705 (! 9/22/20 �0 STATE OF FWRIDP 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) '�/, ��NAL IfilikO THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. A. LYNN MILLER, P.E. 2. FOR SIZES NOT SHOWN, ROUNDUP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. P.E.# 58705 Mullion Anchor Cluster DP at Head/Sill, (+/- pst7 Shim Th ickness: 1/4" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 6 4 6 4 6 4 6 24" 48„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 180" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 24" 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 72„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 118.5 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 114.3 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 111.2 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 102 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 108 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 24" 78" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 104.E 120.0 120.0 120.0 120.0 120.0 60" 118.1 120.0 100.0 120.0 120.0 120.0 120.0 120.0 70" 113.0 120.0 95.7 120.0 120.0 120.0 120.0 120.0 72" 112.5 120.0 95.2 120.0 120.0 120.0 120.0 120.0 84" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 90" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 92" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 96" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 102" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 108" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 Mullion Anchor Cluster DP at Head/Sill, (+/- pst7 Shim Thickness: 1/4" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 6 8 4 6 8 4 6 8 4 6 24" �" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 108.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 110.5 120.0 120.0 93.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 99.2 120.0 120.0 84.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 117.4 120.0 120.0 99.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 94.5 120.0 120.0 80.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 88.4 120.0 120.0 74.8 112.2 120.0 112.2 120.0 120.0 120.0 120.0 72" 87.5 120.0 120.0 74.1 111.1 120.0 111.1 120.0 120.0 120.0 120.0 84" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 90" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 92" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 96" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 24" 97 3/4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 116.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 118.5 120.0 120.0 100.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 105.5 120.0 120.0 89.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 96.1 120.0 120.0 81.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 89.0 120.0 120.0 75.4 113.1 120.0 113.1 120.0 120.0 120.0 120.0 60" 83.7 120.0 120.0 70.8 106.3 120.0 106.3 120.0 120.0 120.0 120.0 70" 77.4 116.2 120.0 65.6 98.3 120.0 98.3 120.0 120.0 120.0 120.0 72" 76.5 114.8 120.0 64.8 97.2 120.0 97.2 120.0 120.0 120.0 120.0 84" 72.6 109.0 120.0 61.5 92.2 120.0 92.2 120.0 120.0 120.0 120.0 24" 102 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 110.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 90.9 120.0 120.0 76.9 115.4 120.0 115.4 120.0 120.0 120.0 120.0 54" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 60" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 70" 72.5 108.8 120.0 61.4 92.1 120.0 92.1 120.0 120.0 120.0 120.0 72" 71.6 107.4 120.0 60.6 90.9 120.0 90.9 120.0 120.0 120.0 120.0 84" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 24" 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 103.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 93.1 120.0 120.0 78.8 118.2 120.0 118.2 120.0 120.0 120.0 120.0 48" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 54" 77.8 116.7 120.0 65.8 98.8 120.0 98.8 120.0 120.0 120.0 120.0 60" 72.7 109.0 120.0 61.5 92.3 120.0 92.3 120.0 120.0 120.0 120.0 70" 66.6 99.9 120.0 56.4 84.5 112.7 84.5 120.0 120.0 120.0 120.0 72" 65.6 98.4 120.0 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 24" 114" 120.0 120.0 120.0 117.E 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 114.5 120.0 120.0 97.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 87.1 120.0 120.0 73.7 110.E 120.0 110.E 120.0 120.0 120.0 120.0 48" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 54" 72.4 108.E 120.0 61.3 92.0 120.0 92.0 120.0 120.0 120.0 120.0 60" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 70" 61.5 92.3 120.0 52.1 78.1 104.2 78.1 117.2 120.0 120.0 120.0 72" 60.6 90.9 120.0 51.3 76.9 102.E 76.9 115.4 120.0 120.0 120.0 SILL SHOWN, HEAD SIMILAR i SEE TABLE 1, SHEET FOR ANCHOR MIN. O Mullion Anchor Cluster DP at Head/Sill, (+/- pst) Shim Thickness: 1/4" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 4 6 8 4 6 8 4 6 8 4 6 24" 120" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 108.0 120.0 120.0 91.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 92.6 120.0 120.0 78.4 117.6 120.0 117.E 120.0 120.0 120.0 120.0 42" 81.8 120.0 120.0 69.3 103.9 120.0 103.9 120.0 120.0 120.0 120.0 48" 73.8 110.7 120.0 62.5 93.8 120.0 93.8 120.0 120.0 120.0 120.0 54" 67.7 101.E 120.0 57.3 86.0 114.7 86.0 120.0 120.0 120.0 120.0 60" 63.0 94.5 120.0 53.3 80.0 106.7 80.0 120.0 120.0 120.0 120.0 70" 57.2 85.8 114.3 48.4 72.6 96.8 72.6 108.9 120.0 120.0 120.0 72" 56.2 84.4 112.5 47.6 71.4 95.2 71.4 107.1 120.0 120.0 120.0 24" 126" 120.0 120.0 120.0 105.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 102.2 120.0 120.0 86.5 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 87.5 120.0 120.0 74.1 111.1 120.0 111.1 120.0 120.0 120.0 120.0 42" 77.1 115.7 120.0 65.3 98.0 120.0 98.0 120.0 120.0 120.0 120.0 48" 69.5 104.2 120.0 58.8 88.2 117.E 88.2 120.0 120.0 120.0 120.0 54" 63.6 95.5 120.0 53.9 80.8 107.7 80.8 120.0 120.0 120.0 120.0 60" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 120.0 120.0 24" 132" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 96.9 120.0 120.0 82.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 82.9 120.0 120.0 70.2 105.3 120.0 105.3 120.0 120.0 120.0 120.0 42" 73.0 109.5 120.0 61.8 92.7 120.0 92.7 120.0 120.0 120.0 120.0 48" 65.6 98.4 120.0 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 54" 60.0 90.0 120.0 50.8 76.2 101.6 76.2 114.3 120.0 120.0 120.0 60" 55.6 83.4 111.2 47.1 70.6 94.1 70.6 105.9 120.0 120.0 120.0 24" 138" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 92.2 120.0 120.0 78.0 117.1 120.0 117.1 120.0 120.0 120.0 120.0 36" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 42" 69.2 103.8 120.0 58.6 87.9 117.2 87.9 120.0 120.0 120.0 120.0 48" 62.2 93.3 120.0 52.6 78.9 105.3 78.9 118.4 120.0 120.0 120.0 54" 56.8 85.1 113.5 48.0 72.1 96.1 72.1 108.1 120.0 120.0 120.0 60" 52.5 78.7 105.0 44.4 66.7 88.9 66.7 100.0 120.0 120.0 120.0 24" 144" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 87.9 120.0 120.0 74.4 111.6 120.0 111.6 120.0 120.0 120.0 120.0 36" 75.0 112.5 120.0 63.5 95.2 120.0 95.2 120.0 120.0 120.0 120.0 42" 65.9 98.8 120.0 55.7 83.6 111.5 83.6 120.0 120.0 120.0 120.0 48" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 120.0 120.0 54" 53.8 80.8 107.7 45.6 68.4 91.2 68.4 102.6 120.0 120.0 120.0 60" 49.7 74.6 99.5 42.1 63.2 84.2 63.2 94.7 120.0 116.4 120.0 24" 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 74.1 75.0 75.0 62.7 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 63.0 75.0 75.0 53.3 75.0 75.0 75.0 75.0 75.0 75.0 75.0 42 55.1 75.0 75.0 46.6 70.0 75.0 70.0 75.0 75.0 75.0 75.0 48" 49.2 73.8 75.0 41.7 62.5 75.0 62.5 75.0 75.0 75.0 75.0 24" 180" 75.0 75.0 75.0 71.4 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 68.7 75.0 75.0 58.2 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 58.3 75.0 75.0 49.4 74.1 75.0 74.1 75.0 75.0 75.0 75.0 42" 50.9 75.0 75.0 43.1 64.7 75.0 64.7 75.0 75.0 75.0 75.0 48" 45.4 68.1 75.0 38.5 57.7 75.0 57.7 75.0 75.0 75.0 75.0 TABLE 4 Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/2" Average Centerline Width Frame Height Group "A" Anchor Quantity Group "B" Anchor Quantity Group "C.' Group "D" Anchor Quantity Anchor Quantity 4 6 4 6 4 6 4 6 24" 48„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 168" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 180" 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 24" 60" 120.0 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 120.0 1 120.0 120.0 1 120.0 120.0 120.0 70" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 90" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 126.0 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 132" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 144" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 72„ 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 1 120.0 120.0 1 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 118.5 120.0 120.0 120.0 120.0 120.0 60" 120.0 120.0 114.3 120.0 120.0 120.0 120.0 120.0 70" 120.0 120.0 111.2 120.0 120.0 120.0 120.0 120.0 72" 120.0 1 120.0 111.1 120.0 120.0 120.0 120.0 120.0 84" 120.0 120.0 111.1 120.0 1 120.0 120.0 120.0 120.0 90" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 92" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 96" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 102" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 108" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120" 120.0 1 120.0 111.1 1 120.0 120.0 120.0 120.0 120.0 24" 78" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 54" 120.0 120.0 104.6 120.0 120.0 120.0 120.0 120.0 60" 118.1 120.0 100.0 120.0 120.0 120.0 120.0 120.0 70" 113.0 120.0 95.7 120.0 120.0 120.0 120.0 120.0 72" 112.5 120.0 95.2 120.0 120.0 120.0 120.0 120.0 84" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 90" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 92" 111.8 120.0 1 94.7 120.0 1 120.0 120.0 120.0 120.0 96" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120.0 102" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 1200. 108" 111.8 120.0 94.7 120.0 120.0 120.0 120.0 120. 0 Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/2" Average Centerline Width FrameFAnchor Height Group "A" Quantity Group "B" Anchor Quantity Group "C" Anchor Quantity Group "D" Anchor Quantity 6 1 8 4 6 8 4 1 6 8 4 1 6 24" 8411 120.0 120.0 120.0 120.0 120.0 120.0 120.0 1120.0 120.0 120.0 1 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 120.0 120.0 120.0 108.8 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 118.1 120.0 120.0 100.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 110.5 120.0 120.0 93.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 99.2 120.0 120.0 84.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 72" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 M.. 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.01 120.0 120.0 90" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 92" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 96" 96.4 1200. 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 102" 96.4 120.0 120.0 81.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 24" 90" 1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 120.0 120.0 120.0 111.1 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 117.4 120.0 120.0 99.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 107.4 120.0 120.0 90.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 54" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 60" 94.5 120.0 120.0 80.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 70" 88.4 120.0 120.0 74.8 112.2 120.0 112.2 120.0 120.0 120.0 120.0 72" 87.5 120.0 120.0 74.1 111.1 120.0 111.1 120.0 120.0 120.0 120.0 84" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 90" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 92" 84.0 120.0 120.0 71.1 106.7 120.0 106.7 120.01 120.0 120.0 120.0 96" 84.0 1 120.0 120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 24" 97-3/4" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 116.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 118.5 120.0 120.0 100.3 120.0 120.0 120.0 120.0 120.01 120.0 1 120.0 42" 105.5 120.0 120.0 89.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48 96.1 120.0 120.0 81.4 120.0 120.0 120.0 120.0 120.0 120.0 120.0 L„ 69 0 120.0 120.0 75.4 113.1 120.0 113.1 120.0 120.0 120.0 120.0 60" 83.7 120.0 120.0 70.8 106.3 120.0 106.3 120.0 120.0 120.0 120.0 70" 77.4 116.2 120.0 65.6 98.3 120.0 98.3 120.0 120.0 120.0 120.0 72" 76.5 114.8 120.01 64.8 97.2 120.0 97.2 120.0 120.0 120.0 120.0 84" 72.6 109.0 120.0 61.5 92.2 120.0 92.2 120.0 120.01 120.0 120.0 24" 102" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 1120.0 120.0 110.3 120.01 120.0 120.0 120.0 120.0 120.0 120.0 36" 112.5 120.0 120.0 95.2 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 100.0 120.0 120.0 84.7 120.0 120.0 120.0 120.0 120.0 120.0 120.0 48" 90.9 120.0 120.0 76.9 115.4 120.01 115.4 120.0 120.0 120.0 120.0 FA„ 84.0 120.0 1120.0 71.1 106.7 120.0 106.7 120.0 120.0 120.0 120.0 60" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 70" 72.5 108.8 120.0 61.4 92.1 120.0 92.1 120.0 120.0 120.0 120.0 72" 71.6 107.4 120.0 60.6 90.9 120.0 90.9 120.0 120.0 120.0 120.0 84" 67.5 101.2 120.0 57.1 85.7 114.3 85.7 120.0 120.0 120.0 120.0 24" 108" 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 120.0 120.0 120.0 103.2 120.0 120.0 120.0 120.0 120.0 120.0 1 120.0 36" 105.0 120.0 120.0 88.9 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 93.1 120.0 120.0 78.8 118.2 120.0 118.2 120.0 120.0 120.0 120.0 48" 84.4 120.0 120.0 71.4 107.1 120.0 107.1 120.0 120.0 120.0 120.0 54" 77.8 116.7 120.0 65.8 98.8 120.0 98.8 120.0 120.0 120.0 120.0 60" 72.7 109.0 120.0 61.5 92.3 120.0 92.3 120.0 120.0 120.0 120.0 70" 66.6 99.9 120.0 56.4 84.5 112.7 84.5 120.0 120.0 120.0 120.0 72" 65.6 98.4 120.0 55.6 83.3 111.1 83.3 120.0 120.0 120.0 120.0 24" 114" 120.0 120.0 120.0 117.6 120.0 120.0 120.0 120.0 120.0 120.0 120.0 30" 114.5 120.0 120.0 97.0 120.0 120.0 120.0 120.0 120.0 120.0 120.0 36" 98.4 120.0 120.0 83.3 120.0 120.0 120.0 120.0 120.0 120.0 120.0 42" 87.1 120.0 120.0 73.7 110.6 120.0 110.6 120.0 120.0 120.0 120.0 48" 78.7 118.1 120.0 66.7 100.0 120.0 100.0 120.0 120.0 120.0 120.0 54" 72.4 108.6 120.0 61.3 92.0 120.0 92.0 120.0 120.0 120.0 120.0 60" 67.5 101.2 120.0 57.1 85.7 1 114.31 85.7 120.0 120.0 120.0 120.0 70" 61.5 92.3 120.0 52.1 78.1 1 104.21 78.1 117.2 1200. 120.0 120.0 72" 60.6 90.9 120.0 51.3 76.9 102.E 76.9 115.4 6 0 120.0 120.0 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. FOR ANCHORLESS JAMBS USE ONLY HALF OF THE ANCHORS SPECIFIED IN TABLE 3, AND: AVERAGE CENTERLINE CENTERLINE = WIDTH 1 WIDTH m Q FOR INTERIOR MULLION CLUSTERS FRAME w USE THE QUANTITY OF ANCHORS HEIGHT Of SPECIFIED IN TABLE 3, AND: p AVERAGE CENTERLINE+CENTERLINE z CENTERLINE = WIDTH 1 WIDTH 2 Q WIDTH 2 3" SEE TABLE 1, SHEET 1 FOF ANCHOR MIN. O.C. SPACING, 4" MAX CENTERLINE WIDTH 1 CENTEF W I DTI SILL SHOWN, HEAD SIMILAR 1 I 3„ SEE TABLE 1, SHEET FOR ANCHOR MIN. O SPARIN(, A" MAY Mullion Anchor Cluster DP at Head/Sill, (+/- pst Shim Thickness: 1/2" Average Centerline Width Frame Height Group "A" Anchor Quantit y Group "B" Anchor Quantit y Group "C" Anchor QuantityAnchor Group "D" Quantit y 4 1 6 1 8 4 1 6 8 4 1 6 8 4 6 24" 120" 1200. 120.0 1200. 111.1 1200. 1200. 1200. 1200. 1200. 1200. 1200. 30" 108.0 1200. 1200. 91.4 1200. 1200. 1200. 1200. 1200. 1200. 120.0 36" 92.6 1200. 1200. 78.4 117.6 1200. 117.6 1200. 1200. 1200. 1200. 42" 81.8 1200. 1200. 69.3 103.9 1200. 103.9 1200. 1200. 1200. 1200. 48" 73.8 110.7 1200. 62.5 93.8 1200. 93.8 1200. 1200. 1200. 1200. 54" 67.7 101.6 1200. 57.3 86.0 114.7 86.0 1200. 1200. 1200. 1200. 60" 63.0 94.5 1200. 53.3 80.0 106.7 80.0 1200. 1200. 1200. 1200. 70" 572 85.8 114.3 48.4 72.6 96.8 72.6 108.9 1200. 1200. 1200. 72" 562 84.4 112.5 47.6 71.4 952 71.4 107.1 1200. 1200. 120.0 24" 126' 1200. 1200. 1200. 105.3 1200. 1200. 1200. 1200. 1200. 1200. 1200. 30" 1022 120.0 120.0 86.5 1200. 1200. 120.0 1200. 1200. 1200. 120.0 36" 87.5 1200. 1200. 74.1 111.1 1200. 111A 120.0 1200. 120.0 1200. 42" 77.1 115.7 1200. 65.3 98.0 1200. 98.0 1200. 120.0 1200. 1200. 48" 69.5 1042 1200. 58.8 882 117.6 882 1200. 1200. 1200. 1200. 54" 63.6 95.5 1200. 53.9 80.8 107.7 80.8 1200,. 1200. 1200. 1200. 60" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 1200. 1200. 1200. 24" 132" 118.1 1200. 120.0 100.0 1200. 1200. 120.0 1200. 1200. 1200. 1200. 30" 96.9 120.0 120.0 82.1 1200. 1200. 120.0 1200. 1200. 1200. 120.0 36" 82.9 1200. 120.0 70.2 105.3 1200. 105.3 120.0 1200. 120.0 1200. 42" 73.0 109.5 1200. 61.8 92.7 1200. 92.7 1200. 1200. 1200. 1200. 48" 65.6 98.4 1200. 55.6 83.3 111.1 83.3 1200. 1200. 1200. 120.0 54" 60.0 90.0 1200. 50.8 762 101.6 76.2 114.3 120.0 1200. 1200. 60" 55.6 83.4 1112 47.1 70.6 94.1 70.6 105.9 1200. 1200. 1200. 24" 138" 112.5 1200. 1200. 952 1200. 1200. 120.0 1200. 1200. 1200. 120.0 30" 92.2 120.0 120.0 78.0 117.1 1200. 117A 120.0 1200. 120.0 120.0 36" 78.7 118.1 1200. 66.7 100.0 1200. 100.0 1200. 1200. 1200. 120.0 42" 69.2 103.8 1200. 58.6 87.9 1172 87.9 1200,. 120.0 1200. 1200. 48" 62.2 93.3 120.0 52.6 78.9 105.3 78.9 118.4 120.0 1200. 120.0 54" 56.8 85.1 113.5 48.0 72.1 96.1 72.1 108.1 120.0 120.0 1200. 60" 52.5 78.7 105.0 44.4 66.7 88.9 1 66.7 100.0 1200.. 120.0 120.0 24" 144" 107.4 1200. 120.0 90.9 120.0 120.0 1200. 120.0 1200. 120.0 120.0 30" 87.9 1200. 120.0 74.4 111.6 120.0 111.6 120.0 1200. 120.0 120.0 36" 75.0 112.5 1200. 63.5 952 120.0 95.2 120.0 1200. 1200. 120.0 42" 65.9 98.8 1200. 55.7 83.6 111.5 83.6 120.0 1200. 1200. 120.0 48" 59.1 88.6 118.1 50.0 75.0 100.0 75.0 112.5 120.0 1200. 120.0 54" 53.8 80.8 107.7 45.6 68.4 912 68.4 102.6 120.0 1200. 1200. 60" 49.7 74.6 99.5 42.1 632 84.2 1 632 94.7 120.0 116.4 120.0 24" 168" 68.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 55.5 75.0 75.0 62.7 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 472 70.8 75.0 53.3 75.0 75.0 75.0 75.0 75.0 75.0 75.0 42" 41.3 61.9 75.0 46.6 70.0 75.0 70.0 75.0 75.0 75.0 75.0 48" 36.9 55.3 73.7 41.7 62.5 75.0 62.5 75.0 75.0 75.0 75.0 24" 180" 63.2 75.0 75.0 71.4 75.0 75.0 75.0 75.0 75.0 75.0 75.0 30" 51.5 75.0 75.0 58.2 75.0 75.0 75.0 75.0 75.0 75.0 75.0 36" 1 43.7 1 75.0 49.4 74.1 75.0 74.1 75.0 75.0 75.0 75.0 42'. 38.1 55.5 57.2 75.0 43.1 64.7 75.0 64.7 75.0 75.0 75.0 75.0 48" 34.0 1 51.0 68.0 38.5 57.7 75.0 57.7 75.0 75.0 75.0 75.0 \`�4ti1111II//7/ \�.���NY LYNN��� •, \,ICENS, z � * : No. 58705 U 9/22/20`_ STATE OF �CORIDP 'Si;SADNAL E .�`• IIIIIII%\ A. LYNN MILLER, P.E. P.E.# 58705 TABLE 5: Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90" 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 144" 18" 18" 18" 18" 168" 18" 18" 18" 18" 180" 18" 18" 18.1 18" 24" 60 1 1 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90" 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 144" 18" 18" 18" 18" 24" 72 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 15" 18" 18" 60" 18" 15" 18" 18" 70" 18" 15" 18" 18" 72" 18" 15" 18" 18" 84" 18" 15" 18" 18" 90.. 18" 15" 18" 18" 92" 18" 15" 18" 18" 96" 18" 15" 18" 18" 102" 18" 15" 18" 18" 108" 18" 15" 18" 18" 120" 18" 15" 18" 18" Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 16-1/2" 18" 18" 54" 18" 16-1/2" 18" 18" 60" 16-112" 16-1/2" 18" 18" 70" 16-1/2" 13-3/16" 18" 18" 72" 16-1/2" 13-3/16" 18" 18' 84" 16-1/2" 13-3/16" 18" 18" 90" 16-1/2" 13-3/16" 18" 18" 92" 16-1/2" 13-3/16" 18" 18" 96" 16-112" 13-3/16" 18" 18" 102" 16-1/2" 13-3/16" 18" 18" 108" 16-1/2" 13-3116" 18" 18" 24" M„ 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 14-3/8" 18" 18" 60" 18" 14-3/8" 18" 18" 70" 18" 14-3/8" 18" 18" 72" 18" 14-3/8" 18" 18" 84" 18" 14-3/8" 18" 18" 90" 18" 14-3/8" 18" 18" 92" 18" 14-3/8" 18" 18" 96" 18" 14-3/8" 18" 18" 102" 18" 14-3/8" 18" 18" 24" 90" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15-5/8" 18" 18" 54" 18" 15-5/8" 18" 18" 60" 15-5/8" 15-5/8" 18" 18" 70" 15-5/8" 13" 1 18" 18" 72" 15-5/8" 13" 18" 18" 84" 15-518" 13" 18" 18" 90" 15-518" 13" 18" 18" 92" 15-5/8" 13" 18" 18" 96" 15-518" 13" 18" 18" 24" 973/4" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17-1/8" 18" 18" 48" 18" 17-1/8" 18" 18" 54" 17-1/8" 14-5/16" 18" 18" 60" 17-1/8" 14-5/16" 18" 18" 70" 14-5/16" 12-1/4" 18" 18" 72" 14-5/16" 12-1/4" 18" 18" 84" 14-5/16" 12-1/4" 17-1/8" 18" 24" 102" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15" 18" 18" 54" 18" 15" 18" 18" 60" 15" 12-7/8" 181, 18" 70" 15" 12-7/8" 181, 18" 72" 15" 12-7/8" 18" 18" 84" 12-7/8" 11-1 /4" 181, 18" Jamb Anchor Spacing Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16" 18" 18" 48" 18" 16" 18" 18" 54" 16" 13-11/16" 18" 18" 60" 16" 13-11116" 18" 18" 70" 13-11/16" 12" 18" 18" 72" 13-11/16" 12" 18" 18" 24" 114" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17" 1 18" 18" 48" 17" 14-9/16" 18" 18" 54" 17" 14-9/16" 18" 18" 60" 14-9/16" 12-314" 18" 18" 70" 14-9/16" 11-5/16" 17" 18" 72" 14-9/16" 11-5/16" 17" 18" 24" 120" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 15-7/16" 18" 18" 54" 15-7/16" 13-1/2" 18" 18" 60" 15-7/16" 13-1/2" 18" 18" 70" 13-1/2" 12" 18" 18" 72" 13-1/2" 10-13/16" 18" 18" 24" 126" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16-5/16" 18" 18" 48" 18" 14-1/4" 18" 18" 54" 16-5/16" 14-114" 18" 18" 60" 14-1/4" 12-11/16" 18" 18" 24" 132" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 17-1/8" 18" 18" 48" 17-1/8" 15" 18" 18" 54" 15" 13-5/16" 18" 18" 60" 15" 12" 18" 18" 24" 138" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 15-3/4" 18" 18" 48" 18" 14" 18" 18" 54" 15-3/4" 14" 18" 18" 60" 14" 12-5/8" 18" 18" 24" 144" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 16-1/2" 18" 18" 48" 16-1/2" 14-11/16" 18" 18" 54" 16-1/2" 13-3/16" 18" 18" 60" 14-11/16" 12" 18" 18" 24" 168" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18.. 18" 18" 24" 180" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" Q z nary FRAME WIDTH U) O W LO 6" MAX. N Q O / w OPTIONAL L SEE TABLE 5, HORIZONTAL ()f W THIS SHEET MULLIONLx 11 (if J O 00 / U H FRAME uoi}duosaQ nay HEIGHT Y 00 / N O O T_ 0 C aO U) J Q w U) a J_ d g ILL Q O1 uMOJQ (, V ' 0 LU Lf ) (- I c3 U •U 10 Z Q co v o U) O� W 0, '(IN m 's Z of 00 c U) 0MO D i ` Cn Cfl = c M O ® 0 6 LL' LL fh O W ' O 00 O J � U ch 2 Q r O Z }gays O > U) W 00 ZYU COJ_ 7 Z W N U � N Z > a O V rn z�� N O 1 2 * O alpaS in �0W� 2 aUOlf v 1:odZa- Z) Ln O OJco c9UW0 ¢ LL w w � m z LL >_ O J O O J WUv $z°W F- m 0 M ¢FZ U�~a W Q O U) d o W O U � > U J o- Z al}!1 asaQ sa!Jos 6" MAX. CENTERLINE WIDTH FRAME WIDTH - 1" 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. \`�4ti111111j�// LYNA(4 •, ,,\CENS, * : No. 58705 U 9I22,2°�_. STATE OF O�� �CORIDP • •���� 1 /;; ANAL E'ON\ /11111 +� A. LYNN MILLER, P.E. P.E.# 58705 TABLE 6 Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 54" 18" 18" 18" 18" 60" 18" 18" 18" 18" 70" 18" 18" 18" 18" 72" 18" 18" 18" 18" 84" 18" 18" 18" 18" 90" 18" 18" 18" 18" 92" 18" 18" 18" 18" 96" 18" 18" 18" 18" 102" 18" 18" 18" 18" 108" 18" 18" 18" 18" 120" 18" 18" 18" 18" 132" 18" 18" 18" 18" 1'"" 18" 18" 18" 18" 168" 18" 18" 18" 18" 180" 18" 18" 18" 18" 24" 60 18" 18" 18" 1 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 16" 18" 18" 18" 48" 16" 18" 18" 18" 54" 16" 18" 18" 18" 60" 16" 18" 18" 18" 70" 16" 18" 18" 1 18" 72" 16" 18" 18" 18" 84" 16" 18" 18" 18" 90" 16" 18" 18" 18" 92" 16" 18" 18" 18" 96" 16" 18" 18" 18" 102" 16" 18" 1 18" 18" 108" 16" 18" 18" 18" 120" 16" 18" 18" 18" 132" 16" 18" 18" 18" 144" 16" 18" 18" 18" 24" 72„ 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15" 18" 18" 18" 48" 15" 18" 18" 18" 54" 15" 15" 18" 18" 60" 15" 15" 18" 18" 70" 15" 15" 18" 18" 72" 15" 15" 18" 18" 84" 15" 15" 18" 18" 90" 15" 15" 18" 18" 92" 15" 15" 18" 18" 96" 15" 15" 18" 18" 102" 15" 1 15" 18" 1 18" 108" 15" 1 15" 18" 18" 120" 15" 1 15" 1 18" 118" Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16-1/2" 18" 18" 18" 42" 16-1/2" 18" 18" 18" 48" 16-1/2" 16-1/2" 18" 18" ,A" 13-3/16" 16-1/2" 18" 18" 60" 13-3/16" 16-1/2" 18" 18" 70" 13-3/16" 13-3/16" 18" 18" 72" 13-3/16" 13-3/16" 18" 18" 84" 13-3/16" 13-3/16" 18" 18" 90" 13-3/16" 13-3/16" 18" 18" 92" 6" 13-3/16" 18" 18" 96" r13-3/16" 13-3/16" 18" 18" 102" 6" 13-3/16" 18" 18" 108" 6" 13-3/16" 18" 18" 24" 84" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 14-3/8" 18" 18" 18" ,A" 14-3/8" 14-3/8" 18" 18" 60" 12" 14-3/8" 18" 18" 70" 12" 14-3/8" 18" 18" 72" 12" 14-3/8" 18" 18" 84" 12" 14-3/8" 18" 18" 90" 12" 14-3/8" 18" 18" 92" 12" 14-3/8" 18" 18" 96" 12" 14-3/8" 18" 18" 102" 12" 14-3/8" 18" 18" 24" 90" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15-5/8" 18" 18" 18" 48" 15-5/8" 15-5/8" 18" 18" 54" 13" 15-5/8" 18" 18" 60" 13" 15-5/8" 18" 18" 70" 11-1 /8" 13" 18" 18" 72" 11-1/8" 13" 18" 18" 84" 11-1/8" 13" 18" 18" 90" 11-1/8" 13" 18" 18" 92" 11-1/8" 13" 18" 18" 96" 11-1/8" 13" 18" 18" 24" 97.75" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 17-1 /8" 18" 18" 18" 42" 14-5/16" 17-1/8" 18" 18" 48" 14-5/16" 17-1 /8" 18" 18" 54" 12-1/4" 14-5/16" 18" 18" 60" 12-1 /4" 14-5/16" 18" 18" 70" 10-3/4" 12-1 /4" 18" 18" 72" 10-3/4" 12-1 /4" 18" 18" 84 10-3/4" 12-1/4" 17-1/8" 18" 24" 102" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 15" 18" 18" 18" 48" 12-7/8" 15" 18" 18" 54" 12-7/8" 15" 18" 18" 60" 11-1 /4" 12-7/8" 18" 18" 70" 11-1 /4" 12-7/8" 18" 18" 72" 11-1/4" 12-7/8" 18" 18" 84" 10" 11-1/4" 18" 18" Jamb Anchor Spacing Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16" 18" 18" 18" 42" 16" 16" 18" 18" 48" 13-11/16" 16" 18" 18" 54" 12" 13-11/16" 18" 18" 60" 12" 13-11/16" 18" 18" 70" 10-11/16" 12" 18" 18" 72" 10-11/16" 12" 18" 18" 24" 114" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 17" 18" 18" 18" 42" 14-9/16" 17" 18" 18" 48" 12-3/4" 14-9/16" 18" 18" 54" 12-3/4" 14-9/16" 18" 18" 60" 11-5/16" 12-3/4" 18" 18" 70" 10-3/16" 11-5/16" 17" 18" 72" 10-3/16" 11-5/16" 17" 18" 24" 120" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 1 18" 42" 15-7/16" 18" 18" 18" 48" 13-1/2" 15-7116" 18" 18" 54" 12" 13-1/2" 18" 18" 60" 10-13/16" 13-1/2" 18" 18" 70" 9-13/16" 12" 18" 18" 72" 9-13/16" 10-13/16" 18" 18" 24" 126" 18" 18" 1 18" 18" 30" 18" 18" 18" 18" 36" 16-5/16" 18" 18" 18" 42" 14-1/4" 16-5/16" 18" 18" 48" 12-11/16" 14-1/4" 18" 18" 'W 11-3/8" 14-1/4" 18" 18" 60" 11-3/8" 12-11/16" 18" 18" 24" 132" 18" 18" 1 18" 18" 30" 18" 18" 18" 18" 36" 17-1/8" 18" 18" 18" 42" 15" 17-1/8" 18" 18" 48" 13-5/16" 15" 18" 18" 54" 12" 13-5/16" 18" 18" 60" 10-15/16" 12" 18" 18" 24" 138" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 15-3/4" 18" 18" 18" 42" 14" 15-3/4" 18" 18" 48" 12-5/8" 14" 18" 18" 54" 11-7/16" 14" 18" 18" 60" 10-1/2" 12-5/8" 18" 18" 24" 144" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 16-1/2" 18" 18" 18" 42" 14-11/16" 16-1/2" 18" 18" 48" 13-3/16" 14-11/16" 18" 18" 54" 12" 13-3/16" 18" 18" 60" 11" 12" 18" 18" 24" 168" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 18" 48" 18" 18" 18" 18" 24" 180" 18" 18" 18" 18" 30" 18" 18" 18" 18" 36" 18" 18" 18" 18" 42" 18" 18" 18" 1 18" 48" 18" 18" 18" 1 18" Q z nary FRAME WIDTH U) C:) w LO 6" MAX. N Q O / w OPTIONAL L SEE TABLE 6, HORIZONTAL ()f W THIS SHEET MULLION J O 00 / U H FRAME uoi}duosaQ nay HEIGHT Y ao / N U) T_ 0 aO U) J Q w U) a J_LL IZ g Q O uMOJQ N LU Lfi al c� U •.a Z Q co v o 2 U) O� W d w _'(IN 0's Q � c HMO 01` ��M Cfl U.= c M O ® 0 �LL� LL Z x °M' w O 00 ¢ o Q N U ch 2 r o Z }aays 0 o � U) W00 ZYU (D J_ 7 w N C - N Z >a oo_ F- rn Zx� NO�2 * O alpaS }O ri OOpw� x ac�� x°6Za � CO O OJ co L cn w ¢ LL w w LN mzLL ro_jLL O JM W V V � Z W W F- W � I QFZ U�Ha w O vJ aow �20 U < H x � > U J a o Z a!}!1 asaQ sauas 6" MAX. CENTERLINE WIDTH FRAME WIDTH - 1" 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. \`�++1111r1j�// �.6NY LYNN��� •, i \,ICENSE * : No. 58705 U 9/22,20`_ STATE OF �CORIDP ,��''Si;S��NAL E�.�`• �rrrlll++ A. LYNN MILLER, P.E. P.E.# 58705 TABLE 7: CENTERLINE CENTERLINE m Q m 0 Q x O FRAME C) HEIGHT w Z Q O 0 Z 0 Q Q H L CORNER TsEE TABLE 3 OR 4 ANCHOR, SEE SHEET 2 MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE ,--i TABLE 7, THIS TABLE 7, THIS ,� iz z SHEET SHEET o of a � CORNER 00 ANCHORS FOR C ~ ANCHORLESS SILL SHOWN, HEAD o w SIMILAR, ANCHOR 't ¢ � o JAMB CONDITION, O 0 U c0 QUANTITY MAY VARY a � x CO a SEE SHEET 3 & U < 3 PER TABLE, THIS SHEET. ® 0 v w U TABLES 3 OR 4. o = c z�Qa w O J Q c U co X: 0 CU v Z Q Z i �w� "'i<2Z' _ c z EE rn No 0 0 C }�1 Opw� J(DN =�ZIL 000LL �0JO o=w o oocn t ¢�z ��~ar of W o Lu O o U D_ Z 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE \ oCE DOOR, PTAC LOUVER OR WINDOW Q�.' INSERT) THE LESSER DESIGN PRESSURE No. VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE = -�_ _ _ _7 DESIGN PRESSURE FOR THE ENTIRE 9I� SYSTEM. �� 2. FOR SIZES NOT SHOWN, ROUND UP TO STAT THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. �i S 3. MID -PANEL ANCHORS TO BE EQUALLY //// /ON SPACED, +/- 1/2". A. LYNN N P.EA Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 4 3 3 72" 4 4 3 3 84" 5 5 4 4 90" 5 6 4 4 92" 5 6 5 5 96" 5 6 5 5 102" 6 7 5 5 108" 6 7 6 6 120" 7 8 6 6 132" 8 9 7 7 144" 9 10 8 8 168" 7 8 5 5 180" 7 8 6 6 24" 60" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 4 3 3 72 4 5 3 3 84" 5 6 4 4 90" 6 6 4 4 92" 6 7 5 5 96" 6 7 5 5 102" 7 8 5 5 108" 7 8 6 6 120" 8 9 6 6 132" 9 11 7 7 144" 10 12 8 8 24" 72„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 90" 6 7 5 4 92" 6 7 5 5 96" 7 8 5 5 102" 7 8 6 5 108" 8 9 6 6 120" 9 11 7 6 WIDTH WIDTH EQ. EQ. EQ. EQ. EQ. EQ. Q Z U) O W CV N_ Lo O Q O W � U � W LU � J m uogdia s0a �noy Y ao N O O J � ' Q W J d LL NN Q 1 (, V W M � 'ON (n NMQ U) CO i LL � 0 Q CO Z /aay� n ~ z z v n k 0 � C:)LL i '�NNtili //'% NSF ,8705►'��J�����* 2I20 �; E OF .•�(/ 11LLER, P.E. 58705 3 Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 90" 6 7 5 4 92" 6 7 5 5 96" 7 8 5 5 102" 7 9 6 5 108" 8 9 6 6 24" 84„ 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 90" 6 7 5 4 92" 6 7 5 5 96" 7 8 6 5 102" 8 9 6 5 24" 90" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 90" 6 7 5 4 92" 6 8 5 5 96" 7 8 6 5 24" 97-3/4" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 24" 102" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 84" 5 6 4 4 Mid -Panel Anchor Quantity Shim Thickness = 1/4" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70 4 5 3 3 72 4 5 3 3 24" 114" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 24" 120" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 70" 4 5 3 3 72" 4 5 3 3 24" 126" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54 3 3 2 2 60" 3 3 2 2 24" 132" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54 3 3 2 2 60" 3 3 2 2 24" 138" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 24" 144" 1 1 1 1 30" 1 1 1 1 36" 1 2 1 1 42" 2 2 1 1 48" 2 2 2 1 54" 3 3 2 2 60" 3 3 2 2 24" 168" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 1 1 1 1 48" 2 1 1 1 24" 180" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 1 1 1 1 48" 2 1 1 1 TARI F R- Mid-Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 48„ 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 4 3 3 72" 5 4 3 3 84" 6 5 4 4 90" 6 6 4 4 92" 7 6 5 5 96" 7 6 5 5 102" 8 7 5 5 108" 8 7 6 6 120" 9 8 6 6 132" 10 9 7 7 144" 11 10 8 8 168" 9 8 5 5 180" 9 8 6 6 24" 60" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 4 3 3 72 5 5 3 3 84" 7 6 4 4 90" 7 6 4 4 92" 8 7 5 5 96" 8 7 5 5 102" 9 8 5 5 108" 9 8 6 6 120" 11 9 6 6 132" 12 11 7 7 144" 13 12 8 8 24" 72„ 1 1 1 1 30" 1 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 5 5 96" 9 8 5 5 102" 9 8 6 5 108" 10 9 6 6 120" 12 11 7 6 Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 78" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 5 5 96" 9 8 5 5 102" 10 9 6 5 108" 11 9 1 6 6 24" 84„ 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 7 5 5 96" 9 8 1 6 5 102" 10 9 6 5 24" 90" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 90" 8 7 5 4 92" 8 8 5 5 96" 9 8 6 5 24" 97-3/4" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 84" 7 6 4 4 24" 102" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70 5 5 3 3 72" 5 1 5 3 3 84" 7 1 6 4 4 Mid -Panel Anchor Quantity Shim Thickness = 1/2" Nominal Dim. Installed with Group "A" Anchors Installed with Group "B" Anchors Installed with Group "C" Anchors Installed with Group "D" Anchors Centerline Width Frame Height 24" 108" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 1 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 114" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 120" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 70" 5 5 3 3 72" 5 5 3 3 24" 126" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 3 2 2 24" 132" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60 4 3 2 2 24" 138" 1 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 4 1 3 2 2 24" 144" 1 1 1 1 30" 1 1 1 1 36" 2 2 1 1 42" 2 2 1 1 48" 3 2 2 1 54" 3 3 2 2 60" 1 4 3 2 2 24" 144" 1 1 1 1 30" 1 1 1 1 36" 1 1 1 1 42" 2 1 1 1 48" 2 2 1 1 24" 144" 1 1 1 1 30" 1 11 1 1 36" 1 1 1 1 42" 2 1 1 1 48" 2 2 1 1 CENTERLINE CENTERLINE WIDTH WIDTH SEE TABLE 3 OR 4 MID -PANEL MID -PANEL ANCHORS, SEE ANCHORS, SEE TABLE 8, THIS TABLE 8, THIS SHEET SHEET CORNER ANCHORS FOR SILL SHOWN, HEAD ANCHORLESS JAMB CONDITION, SIMILAR, ANCHOR SEE SHEET 3 & QUANTITY MAY VARY TABLES 3 OR 4. PER TABLE, THIS SHEET. 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE STOREFRONT ENTRANCE DOOR, PTAC LOUVER OR WINDOW INSERT) THE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW SHALL BE THE DESIGN PRESSURE FOR THE ENTIRE SYSTEM. 2. FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. 3. MID -PANEL ANCHORS TO BE EQUALLY SPACED, +/- 1/2". m 2 Q w O FRAME U HEIGHT Z Q Q Z Q H LCORNER ANCHOR, SEE SHEET 2 T—q 1 co •v U I= Z o vi C_ Of o E2 � p U W zOfCC) Q O o 0 ��M = M C ® O7 LL o Z_ _C w O J � cc)Q c U co 0 O Ld Ld CU J v Z W NocnQ 2H >_ O OfH z�m NOF- }� riOUpwO J0N Zai m Z LL } 0 J LL o=LL IL ¢Luz ova~a' W o LU O i a - 2 U L .'OCE ` * No. — 11 91, STAI T �s'•.!�C0 S A. LYNN P P.EJ Q Z A2 U O W N IN LO Q O LU U Lu LU J O m U � Uogdia3soa noy Y ao U) T_ N O U o o ao J U) ' Q W J d LL FN Q ) W M U) Ljj 'ON (n DNIQ U) CO LL O O Q � >Z 4_9 n ~ z z v n k 0 ojooc LL C:)LL 04 J M i NSF • ����' ;' ,8705 ll� G G,L 1 2I20 E OF 310 11LLER, P.E. 58705 TABLE 9: 48 1. IF COMBINED WITH ANOTHER ASSEMBLY WITH A SEPARATE APPROVAL, (COMPATIBLE LESSER DESIGN PRESSURE VALUE OF ANY ASSEMBLY OR THE STOREFRONT WINDOW 2. FOR SIZES NOT SHOWN, ROUNDUP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION. Q Z na,y AVERAGE CENTERLINE + CENTERLINE (n ON CENTERLINE = WIDTH 1 WIDTH 2 W WIDTH 2 N U CENTERLINE WIDTH 1NE� WIDTH 2 CENTERLINE C) O W U / W / OPTIONAL J HORIZONTAL O Q MULLION U FRAME REINFORCEMENT uogdussos nos HEIGHT PART # 10, IF _ REQUIRED, i 00 SEE TABLE 9 >� T— N O O eO J Q INTERIOR MULLIONS w J a ILL s Q O UM as HNL^/.� T� fn w Y J • v z C) CM AVERAGE CENTERLINE W a of of � U) CENTERLINE = WIDTH 1 E a W WIDTH 2 o W os a� SMS �i CENTERLINE CENTERLINE �� It Q Of 00 O U U M WIDTH 1 WIDTH 2 U i¢` o (n ® oo6LL'o = M LL ��Lu ) O O O J Lo REINFORCEMENT / (� Q o Q Ln PART # 10, IF / U M 2 z r REQUIRED, O ways SEE TABLE 9 O Uj CD CU _; v ? Y C� co ^ O Q Z 0) 7 FRAME j! �o�2F- rn z L xx s HEIGHT z o N o O �� J } W W = /Qc�� =.6 � O � O / oM (��W0 Q w Lw// NLo U U O z W W m O Cn Q Lu Z U ~ LL W Q W o w L) U Of o U LL — Z ass�sas sauas ANCHORLESS JAMB/MULLION ��`��N�(ILYN/�//``'% \�\�� /y�` �\-ENS,- No. 58705 C! 9/22/20 jz— �— �0 STATE OF �(/ FWRIDP �s ....,.. , ��NAL I \ A. LYNN MILLER, P.E. P.E.# 58705 STOREFRONT SHALL BE ENTRANCE THE DESIGN DOOR, PTAC PRESSURE LOUVER FOR THE OR ENTIRE WINDOW INSERT). SYSTEM. THE Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" Unreinforced HD Mullion 7" Reinforced HD Mullion 24" 48„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +70/-80 +90/-120 +70/-70 +60/-75 72" +70/-80 +90/-120 +70/-70 +60/-75 84" +70/-80 +90/-120 +70/-70 +60/-75 90" +70/-80 +90/-120 +70/-70 +60/-75 92" +70/-80 +90/-120 +70/-70 +60/-75 96" +70/-80 +90/-120 +70/-70 +60/-75 102" +90/-120 +70/-70 +60/-75 108" +90/-120 +70/-70 +60/-75 120" +90/-120 +70/-70 +60/-75 132" +90/-100 +70/-70 +60/-75 144" +90/-100 +70/-70 +60/-75 168" +60/-75 180" +60/-75 24" 60 +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +70/-80 +90/-120 +70/-70 +60/-75 72" +70/-80 +90/-120 +70/-70 +60/-75 84" +90/-120 +70/-70 +60/-75 90" +90/-120 +70/-70 +60/-75 92" +90/-120 +70/-70 +60/-75 96" +90/-120 +70/-70 +60/-75 102" +90/-100 +70/-70 +60/-75 108" +90/-100 +70/-70 +60/-75 120" +90/-100 +70/-70 +60/-75 132" +70/-70 +60/-75 144" +70/-70 +60/-75 24" 72„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +90/-120 +70/-70 +60/-75 72" +90/-120 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +90/-100 +70/-70 +60/-75 92" +90/-100 +70/-70 +60/-75 96" +90/-100 +70/-70 +60/-75 102" +70/-70 +60/-75 108" +70/-70 +60/-75 120" +70/-70 +60/-75 Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" UnreinforceL HD Mullio 7" inforced Mullion 24" 78" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +70/-80 +90/-120 +70/-70 +60/-75 70" +90/-120 +70/-70 +60/-75 72" +90/-120 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +90/-100 +70/-70 +60/-75 92" +90/-100 +70/-70 +60/-75 96" +70/-70 +60/-75 102" +70/-70 +60/-75 108" +70/-70 +60/-75 24" 84„ +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +70/-80 +90/-120 +70/-70 +60/-75 60" +90/-120 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +90/-100 +70/-70 +60/-75 90" +70/-70 +60/-75 92" +70/-70 +60/-75 96" +70/-70 +60/-75 102" +70/-70 +60/-75 24" 90" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +g0/-120 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +70/-70 +60/-75 90" +70/-70 +60/-75 92" +70/-70 +60/-75 96" +70/-70 +60/-75 24" 97-3/4" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +70/-80 +90/-120 +70/-70 +60/-75 48" +70/-80 +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +90/-100 +70/-70 +60/-75 84" +70/-70 +60/-75 24" 102" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +70/-80 +90/-120 +70/-70 +60/-75 42" +68.3/-78.1 +90/-120 +70/-70 +60/-75 +90/-120 +70/-70 +60/-75 54" +90/-120 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +90/-100 +70/-70 +60/-75 72" +70/-70 +60/-75 84" +70/-70 +60/-75 Mullion DP, psf Average Centerline Width Frame Height 5" Unreinforced Mullion 5" Reinforced Mullion 7" Unreinforced HD Mullion 7" Reinforced HD Mullion 24" 108" +70/-80 +90/-120 +70/-70 +60/-75 30" +70/-80 +90/-120 +70/-70 +60/-75 36" +65.6/-74.9 +90/-120 +70/-70 +60/-75 42" +57.1/-65.3 +90/-120 +70/-70 +60/-75 48" +g0/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24° 114" +70/-80 +90/-120 +70/-70 +60/-75 30" +65.8/-75.2 +90/-120 +70/-70 +60/-75 36" +55.5/-63.4 +90/-120 +70/-70 +60/-75 42" +90/-120 +70/-70 +60/-75 48" +g0/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24" 120" +69.7/-79.6 +90/-120 +70/-70 +60/-75 30" +56.2/-64.3 +90/-120 +70/-70 +60/-75 36" +47.4/-54.2 +90/-120 +70/-70 +60/-75 42" +90/-120 +70/-70 +60/-75 48" +90/-120 +70/-70 +60/-75 54" +90/-100 +70/-70 +60/-75 60" +90/-100 +70/-70 +60/-75 70" +70/-70 +60/-75 72" +70/-70 +60/-75 24" 126" +60.1/-68.7 +90/-120 +70/-70 +60/-75 30" +48.5/-55.4 +90/-120 +70/-70 +60/-75 36" +40.8/-46.6 +90/-120 +70/-70 +60/-75 42" +g0/-116.1 +70/-70 +60/-75 48" +90/-100 +70/-70 +60/-75 54" +84/-93.4 +70/-70 +60/-75 60" +70/-70 +60/-75 24° 132" +52.2/-59.6 +90/-120 +70/-70 +60/-75 30" +42.1/-48.1 +90/-120 +70/-70 +60/-75 36" +90/-116.1 +70/-70 +60/-75 42" +90/-100.6 +70/-70 +60/-75 48" +80.5/-89.4 +70/-70 +60/-75 54° +72.6/-80.6 +70/-70 +60/-75 24" 138" +45.6/-52.1 +90/-120 +70/-70 +60/-75 30" +36.7/-42 +90/-120 +70/-70 +60/-75 36" +90/-101.3 +70/-70 +60/-75 42" +79.2/-88 +70/-70 +60/-75 48" +70.1/-77.9 +70/-70 +60/-75 54" +70/-70 +60/-75 24" 144" +40.1/-45.8 +90/-120 +70/-70 +60/-75 30" +32.3/-36.9 +90/-105.9 +70/-70 +60/-75 36" +80.3/-89.2 +70/-70 +60/-75 42" +69.5/-77.2 +70/-70 +60/-75 48" +61.5/-68.3 +70/-70 +60/-75 24" 168 +60/-75 30" +60/-75 36" +60/-75 48" +60/-65 24" 180" +60/-75 30" +60/-75 36" +60/-75 48" +60/-60 ASSEMBLY DETAILS ALL DETAILS SHOWN FROM THE EXTERIOR HORI, EXTERIOR 5.000" 2.000" .094" 10 JAMB/MULLION 4.596" .094" 1.385" 40HORIZONTAL POCKET FILLER 3.878" 062" 1.000" 9/16" LAMI GLASS STOP .313" 4.500" 10 STEEL REINFORCEMENT TARI F in. 5.000" 2.000" .094" ( HEAD/SILL/HORIZONTAL 4.192" .094" � .4 C� FLAT FILLER PLATE (USED WITH NON-REINF. MULLION) 3.193" .062" 1.000" 801-1/4" IG GLASS STOP' 11 HD JAMB/MULLION Item# Part# T Description Material 1 CGIC-206 Jamb/Mullion 6063-T6 Alum. 2 CGIC-201 Head/Sill/Horizontal 6063-T6 Alum. 3 CGIC-207 Vertical Pocket Filler 6063-T6 Alum. 4 CGIC-202 Horizontal Pocket Filler 6063-T6 Alum. 5 CGIC-203 Flat Filler Plate (used with non-reinf. mullion) 6063-T6 Alum. 6 CGIC-003 Flat Filler Plate (used with reinforced mullion) 6063-T6 Alum. 7 CGIC-204 9/16" Lami Glass Stop 6063-T6 Alum. 8 CGIC-205 1-1/4" IG Glass Stop 6063-T6 Alum. 9 CGIC-212 Door Transom Adapter 6063-T6 Alum. 10 CGIC-209 Steel Reinforcement A36 Steel 11 CGIC-208 HD Jamb/Mullion 6063-T6 Alum. 13 CGIC-214 HD Jamb Cover 6063-T6 Alum. 14 CGIC-213 HD Mullion Cover 6063-T6 Alum. 30 1652 Setting Block 3/16" x 7/16" x 4", Duro = 85 +/-5 EPDM 31 1704 IG Setting Block 3/16" x 1-3/32" x 4", Duro = 85 +/-5 EPDM 36 Thermo -plastic Spacer System varies 37 Foam Spacer System varies 38 Metal Reinforced Foam Spacer System varies 39 Metal Spacer System varies 40 CGIC-006 Glass Stop Gasket (@ beading, duro. = 65 +/-5) EPDM 41 CGIC-007 Spacer Gasket (@ glazing leg, duro. = 80 +/-5) Santoprene 42 Silicone Backbedding: Dow 791, 983, 995, GE7700 50 CGIC-010 Frame Assembly Screw (#12 x 1-1/2" Hex Washer) Stainless Steel (: VERTICAL POCKET FILLER OFL T FILLER PLATE (USED WITH REINFORCED MULLION) ODOOR TRANSOM ADAPTER 13 HD JAMB COVER 14 HD MULLION COVER \\�,\II �` �{ L E ` * No.: " v y/ STAI S A. LYNN P P. E.f NSF • �(�� �' ,8705 r 2/20 E OF CN TILLER, P.E. 58705