HomeMy WebLinkAboutOSTDS NEWSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
CONSTRUCTION PERMIT FOR: OSTDS New
APPLICANT: (Port St. Lucie Properties)
PROPERTY ADDRESS: 1625 Easy St Fort Pierce, FL 34982
LOT: 36
PROPERTY ID �:
PERMIT #:56-SF-2429919
APPLICATION #:AP1771096
DATE PAID:
FEE PAID:
RECEIPT #.
DOCUMENT #: PR1736313
BLocx: g2 suaoxvxsxoN: Indian River Estates
3402-610-0630-000-1 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER]
[OR TAX ID NUMBER]
SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION
381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE
SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS,
WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE
PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID.
ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL,
STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY.
SYSTEM DESIGN AND
T
[
1,050 ] GALLONS / GPD
Seotic New
CAPACITY
A
[
] GALLONS / GPD
N/A
CAPACITY
N
[
7 GALLONS GREASE
INTERCEPTOR CAPACITY
[MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS]
K
[
] GALLONS DOSING
TANK CAPACITY [
]GALLONS @[ ]DOSES PER 24 HRS #Pumps [
D [ 667 ] SQUARE FEET Drainfield New SYSTEM
R [ ] SQUARE FEET N/A SYSTEM
A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X7 MOUND
I CONFIGURATION: [ ] TRENCH [X] BED [1
N
F LocATxox of BENCHMARK: PAINTED NID NW OF PROP IN FRONT OF FIRE HYDRANT.
I ELEVATION OF PROPOSED SYS
E BOTTOM OF DRAINFIELD TO BE
L
TEM SITE [ 2.00 ][
FT It
BELOW]BENCFHdARK/
[ 14.00 ][ INCHES FT ][ ABOVE BELOW]BENCHMARK/REFERENCE POINT
D FILL REQUIRED: [30.00] INCHES EXCAVATION REQUIRED: [ ] INCHES
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated Flow of
400 gpd.
T
H
E
R
SPECIFICATIONS BY: Matthew S Vajanyi TITLE: Environmental Specialist I
APPROVED BY: TITLE: Environmental Specialist I St. LNCIe CHD
Matthew S Vaj
DATE ISSUED: 02/14/2022 EXPIRATION DATE: 08/14/2023
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 1 of 3
V _.1.M1 A!317�109`6 9C3552779
NOTICE OF RIGHTS
A party whose substantial interest is affected by this order may petition for an
administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such
proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for
administrative hearing must be in writing and must be received by the Agency Clerk for the
Department, within twenty-one (21) days from the receipt of this order. The address of the
Agency Clerk is 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-
3000, The Agency Clerk's email is agency_clerk@FloridaDEP.gov.
Mediation is not available as an alternative remedy.
Your failure to submit a petition for hearing within 21 days from receipt of this order will
constitute a waiver of your right to an administrative hearing, and this order shall become a 'final
order'.
Should this order become a final order, a party who is adversely affected by it is entitled
to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are
governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced
by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of
Environmental Protection and a second copy, accompanied by the filing fees required by law,
with the Court of Appeal in the appropriate District Court. The notice must be filed within 30
days of rendition of the final order.
_ St. Lucie County Health Department
I'Ikg -} 5150 NW Milner Dr Port Saint Lucie, FL 34983
HEALTH
PAYING ON:
n: 56-SF-2429919
BILL DOCu:56-BID-5739763
CONSTRUCTION
APPLICATION#: AP1771096
RECEIVED FROM:
Alexander J Piazza
AMOUNT PAID:
$ 545,00
PAYMENT FORM:
CHECK 7087
PAYMENT DATE:
12/17/2021
MAIL TO: (Port St. Lucie Properties)
FACILITY NAME
PROPERTY LOCATION:
1625 Easy St
Fort Pierce, FL 34982
36
Lot:
92
Block:
Property ID: 3402-610-0630-000-1
EXPLANATION or DESCRIPTION:
128 - OSTDS Construction System Inspection Research Fee
-1 - Surcharge (All)
-1 - OSTDS New Permit Surcharge
-1 - OSTDS Construction Application and Plan Review,New
123 - OSTDS Construction Site Evaluation
126 - OSTDS Construction Permit (New or Mod, Amendment)
127 - OSTDS Construction System Inspection
133 - OSTDS Construction Reinspection
QUANTITY FEE
1
$
45,00
1
$
100,00
1
$
100,00
1
$
115,00
1
$
55,00
1
$
75,00
1
$
50,00
RECEIVED BY: AdamsC __^_____ AUDIT CONTROL NO. 56-PID-5411471 _���
[liE
-.
STATE OF FLORIDA
DEPARTMENT OF HEALTH
"t'a? ONSITE SEWAGE TREATMENT AND DISPOSAL
SYSTEM
APPLICATION FOR CONSTRUCTION PERMIT
APPLICATION FOR:
PERMIT NOS /J^I'%DIq
DATE PAID: I?—J] -ZJ
FEE PAID: Gil Gr—
RECEIPT #: L1<iL 6>
[i/]
New System
[ ]
Existing System
[
] Holding Tank [ ] Innovative
[ ]
Repair
[ ]
Abandonment
[
] Temporary [ ]
APPLICANT : Port St. Lucie Properties, Inc.
AGENT:
Alexander J. Piazza
PSM, Inc.
TELEPHONE:
MAILING ADDRESS:
619
SW Bitttnore Street, Port St.
Lucie, Florida 34983
772-340-7770
TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED
BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES, IT IS THE
APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR
PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS.
PROPERTY INFORMATION
LOT: 36 BLOCK:
PROPERTY ID #:
92 SUBDIVISION: Indian River Estates Unit 9 PLATTED: 1957
3402-610-0630-000-1
ZONING: RS- j I/M OR EQUIVALENT: [ No ]
PROPERTY SIZE: 0.467 ACRES WATER SUPPLY: [ J PRIVATE PUBLIC [�]<=2000GPD [ ]>2000GPD
IS SEWER AVAILABLE AS PER 381.0065, FS? [ NO ] DISTANCE TO SEWER: FT
PROPERTY ADDRESS: j`Z EASY STREET, Fort Pierce, FL 34982
DIRECTIONS TO PROPERTY: SEE MAP
BUILDING INFORMATION
Unit Type of
No Establishment
1 RESIDENCE
2
3
0
[ � ] RESIDENTIAL [ ] COMMERCIAL
No. of Building Commercial/Institutional System Design
Bedrooms Area Sgft Table 1, Chapter 64E-6, FAC
3 2,299
[ ] Floor/Equipment Drains [i/] Other (Specify) GARBAGE GRINDERS/DISPOSALS
NATURE: Alexander J Piazza ,,o,�,,.,,H'��
15, 08/09 (Obsoletes previous editions which may not be used)
orated 64E-6.001, FAC Page 1 of 4
STATE OF FLORIDA APPLICATION # A'1'771096
DEPARTMENT OF HEALTH PERMIT # 56-SF-2429919
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
SITE EVALUATION AND SYSTEM SPECIFICATION DOCUMENT # SE1652779
APPLICANm: POrt St. Lucie Properties
CONTRACTOR / AGENT: Alexander Piazza
LOT: 36 BLOCK: 92
svgolVlsloN: Indian River Estates ID#: 3402-610-0630-000-1
TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE
REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS,
PROPERTY SIZE CONFORMS TO SITE PLAN: [X IYES [ ]NO NET USABLE AREA AVAILABLE: 0.47 ACRES
TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER -TABLE 2 ]
AUTHORIZED SEWAGE FLOW: 1174.99 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ]
UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00
SQFT
BENCHMARK/REFERENCE POINT LocATlox: PAINTED NID NW
OF FIRE HYDRANT.
ELEVATION OF PROPOSED SYSTEM SITE 2,00 [ INCHESBELOW ] BENCHMARR/REFERENCE POINT
THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES
SURFACE WATER: FT DITCHES/SWALES: FT NORMALLY WET: [ ]YES [ ]NO
WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: FT
BUILDING FOUNDATIONS: T8 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 44 FT
SITE SUBJECT TO FREQUENT FLOODING? [ ]YES IX]NO 10 YEAR FLOODING? [ ]YES [X]NO]
10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVO
SOTT, DROFTT.F. T
USDA SOIL SERIES:
Munsel[ #/Color Texture Depth
10YR 611 Sand 0 To 15
10YR 7/1 Sand 11 To 30
10YR 211 Spodic Material 30 To 43
7.5YR 3/2 Loamy Sand 43 To 48
10YR 4/3 Fine Sand 48 To 60
REFUSAL Hardpan 60 To 72
SOIL PROFTT.F. TNFORMATTrIN R
VSDA SOIL SERIES:
Munsell #/Color
SOIL PROFTT.F. TNFORMATTrIN R
VSDA SOIL SERIES:
Munsell #/Color
Texture
Depth
10YR 6/1
Sand
0 To 15
tOYR 711
Sand
12 To 36
10YR 2/i
Spodic Material
36 To 48
tOYR 4/3
Loamy Fine Sand
48 To 66
REFUSAL
Refusal
66 To 72
OBSERVED WATER TABLE: 30.00
INCHES [ABOVE
/
BELOW
] EXISTING
GRADE
TYPE:
( PERCHED / APPARENT
ESTIMATED WET SEASON WATER TABLE
ELEVATION:
12 INCHES [
ABOVE
/
BELOW
]
EXISTING GRADE
HIGH WATER TABLE VEGETATION:
[ ]YES [X]NO
MOTTLING: [X]YES
[ ]NO
DEPTH: 12.00 INCHES
SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING:
$and/0.60
DEPTH OF EXCAVATION: INCHES
DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED
[ ]
OTHER
(SPECIFY)
(• REMPdIKS/ADDITIONAL CRITERIA
SWT determined
using USDA
WSS
and soil borings.
10YR711
stripping in a
10YR6/1 matrix>
10%
with
diffuse
boundaries
starting
12" in S62. SBt
0" above BM.
S62
2" above BM,
SITE EVALUATED BY:
valanyy mannew (rltte:
�5 viron�(al Specialist I) (Florida Department of Health in S
DH 4015,
O6/09
(Obaoletea
previous editions rhich
may not be used) Incorporated: 64E-6. 001, FAC
DATE: 02/11/2022
Page 3 of 4
A P'I 77'1096 IrJ�!').9919
APPLICANT'S NAME:
Port St. Lucie Properties, Inc.
LEGAL DESCRIPTION: Lot 36 & E 9' Lot 35, BIk;92, IRE Unit 9 (PB 101 PG 74)
PROPOSED SEPTZCSYS7'JVVFF0"ATrQN
I certify that there are no potable private wells within 75 feet of the available area for the
proposed septic system, that there are no non -potable wells within 50 feet of the available area
for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated
building foundation, that there are no public wells that serve less than 25 people or less than
15 homes or businesses within 100 feet of the proposed septic system, that there are no public
wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of
the proposed septic system, that the water line from the water meter or well to the structure is
at least 10 feet from the available area for the proposed septic system unless the plans show
the fine to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or
vacuum sewage line in a public easement or right-of-way that abuts the property, that there
are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the
proposed septic system unless the property was created prior to 1972, that the septic system is
proposed on the side of the lot farthest from surface water, that all private wells, septic
systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot
are shown on the site plan, that all public wells within 200 feet of the applicant's lot are
shown on the site plan, and that the location of building or residences, swimming pools,
recorded easements, paved areas or driveways, sidewalks, the general slope of the property,
filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or
wetlands are shown on the applicants lot.
The natural grade elevation in the area of the proposed septic system and the benchmark must
be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic
system.
NOTE: MUST BE CERTIFIED BY A FLORIDA
REGISTERED SURVEYOR OR ENGINEER.
Alexander) Piazza �_ 119»E=�eJ&
CERTIFIED BY:
FLORIDA PROFESSIONAL NO.: 6330
DATE: 10/30/21 JOB NO.: 21-186
docslforms/septics/Sep ticApppPage207
Page 4 of 4
Michelle Franklin, CFA-- Saint Lucie County Property Appraiser -- All rights reserved.
Property Identification
Site Address: 1625 EASY ST Parcel 1D: 3402-610-0630- Account #: 38712 Sec/Town/Range: 11/36S/40E
000-1 Map ID: 34/118 Zoning: RS-3 - Cou
Use Type: 0000 Jurisdiction: Saint Lucie
County
Ownership Legal Description
231 NW 1 st Avenue LLC INDIAN RIVER ESTATES -UNIT 09- BLK 92 E 9 FT OF LOT
7258 Oakmont DR 35 AND ALL LOT 36 (MAP 34/11 S)
Lake Worth, FL 33467
Current Values Historical Values 3-year
Just/Market: $30,700 Assessed: $25,850 Year
Just/Market
Assessed
Exemptions
Taxable
Exemptions: $0 Taxable: $255850 2021
$30,700
$25,850
$0
$25,850
2020
$23,500
$235500
$0
$239500
2019
$20,500
$17,968
$0
$17,968
Sale History
Date
Book/Page
Sale Code Deed Grantor
Price
$14,200
$35,000
$17,500
Total Areas
Finished/UnderAir
0
(SF):
Gross Sketched Area
0
.. (SF):
Land Size (acres):
0,47
Land Size (SF):
20,625
Total Building Count:
1
Special
Features
and Yard
Items
Type
Qly
Units
Year Blt
All information is believed to be correct at this time, but is subject to change and is provided without any warranty.
C Copyright 2021 Saint Lucie County Property Appraiser. All rights reserved,