HomeMy WebLinkAboutNOA - ROOF SHINGLES r
RECEIVED
JAN 21 2021
MIAMbDADE
St.Lucie County Permitting MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
Copy T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) jLL 1 www.m-amidade.gov/economy
TAMKO Building Products LLC
220 West 411 Street
Joplin,MO 64801
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ (in areas other than Miami-Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TAMKO Roof Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA No.19-1107.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Seinino
NOA No.:20-0701.02
QMMAM•uane:c=U, Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 1 of 7
a
0
ROOFING ASSEMBLY APPROVAL
Cateaor: Roofing
Sub-Cateizory: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves TAMKO's Heritage,Heritage Woodgate, Heritage Premium,and Heritage Proline Titan XT
asphalt shingles,manufactured by TAMKO Building Products LLC,as described in this Notice of Acceptance and
designed to comply with the Florida Building Code High Velocity Hurricane Zones.
PRODUCT DESCRIPTION
Product Dimensions Test Produ"escri tion
' ions
1-
Heritage 13 '/a" x 39 3/8" TAS 110 Dimensional asphalt shingle.
anufacturing Location #1, 2, 3
Heritage Woodgate 3'/a"x -/8" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1,3
Heritage Premium 13 '/4"x 39 3/a" TAS 110 Dimensional asphalt shingle.
Manufacturing Location #1, 2, 3
Heritage Proline Titan XT
Manufacturing Location #3, 4
13 '/4"x 39 3/s" TAS 110 Dimensional asphalt shingle.
MANUFACTURING LOCATIONS
1. Dallas,TX
2. Tuscaloosa,AL
3. Frederick,MD
4. Phillipsburg,KS
NOA No.:20-0701.02
MIAM col Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 2 of 7
S ,
EVIDENCE SUBMITTED
Test A2encv Test Identifier Test Name/Reuort Date
Underwriters Laboratories,Inc. TAS 107 & UL 790 04CA44252 02/25/05
ASTM D3462 02NK33813 09/23/02
ASTM D 3462&TAS 107 R2919 Letter 03/10/11
ASTM D3462 4789110543 08/26/14
TAS 107 02/19/15
ASTM E 108 08/26/14
ASTM D3161,Class F 4787043752 10/20/15
ASTM D 3462 4789650787 10/12/20
R 2919 Letter 10/15/20
ASTM D 3462 4789682154 10/15/20
PRI Asphalt Technologies,Inc. TAS 100 TAP-129-02-01 05/26/05
TAS 100 TAP-130-02-01 05/26/05
TAS 100 TAP-131-02-01 05/26/05
PRI Construction Materials Technologies LLC TAS 100 TAP-303-02-01 12/12/14
TAS 100 TAP-307-02-01 02/10/15
TAS 100 TAP-317-02-01 09/02/15
0
NOA No.:20-0701.02
r�u,MannnFcounrrr. Expiration Date: 12/O1/25
Approval Date: 11/05/20
Page 3 of 7
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shingles shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115.
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail `A', attached.
5. Nailing shall be in compliance with Details W,attached.
LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of
manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or with
the Miami-Dade County Product Control Seal as seen below:
CMIAMIM-DADE COUJNTY
, . . . • 1 /
BUILDING PERMIT REQUIREMENTS
As required by the Building Official or the applicable Building Code in order to properly evaluate the
installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit.
NOA No.:20-0701.02
MIAMFDAMCOUNTY Expiration Date: 12/01/25
III "'• •I Approval Date: 11/05/20
Page 4 of 7
0
DETAIL A
HERITAGE,HERITAGE WOODGATE, HERITAGE PREMIUM ,AND HERITAGE
PROLINE TITAN XT
All ions are in inches.
5TH COURSE
4TH COURSE
gMe"
3RD COURSE
&.3.
8
2ND COURSE
° 23
1ST COUR E
2s
Full
ETAIL B
HERITAGE,HERITAGE WOODGATE,HERITAGE PREMIUM,AND HERITAGE
PROLINE TITAN XT SHINGLE
FIG. 1 FASTENING PATTERN
i
All dimensions are in inches
39-3/9'
1" 1 / '/2" I 7'/" I 7 3/9' 7'/� 7'/2"I
-114"
------ -° " `--- ------ ---------------------------- -------------- ------------------ 516-1/9' 8
,� re
NOA No.:20-0701.02
CMMM
Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 5 of 7
a
DETAIL B (CONTINUED)
HERITAGE,HERITAGE WOODGATE,HERITAGE PREMIUM, AND HERITAGE
PROD E TITAN XT SHINGLE
FIG. 2 ALTERNATE FASTENING PATTERN
c Common Bond
r
Id1
HERITAGE SHINGLE
(TuSCALOOSA,AL)
FIG. 3 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG.2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE.
P
a �
�,
BOND. '
�p 4 �JR
.._ 4
R LOCATION:.... .: ...
Lfi FASTEN
t3 L3IC
IR �RII
TINE
_.
NOA No.:20-0701.02
CMWAM*MMAJDXEMUNTY Expiration Date: 12/01/25
Approval Date: 11/05/20
Page 6 of 7
HERITAGE PROLINE TITAN XT SHINGLES
FIG.4 ALTERNATE FASTENING PATTERN
HORIZONTAL NAIL SPACING IN ACCORDANCE WITH FIG. 1 OR FIG.2.
VERTICAL NAIL SPACING ALLOWED ANYWHERE WITHIN NAIL ZONE.
in- Zone
' ~\Paint Unes
- 5-5/`8�
cxpos ure
Acceptable Fastener Looalft n
'referred Fastener Local on
END OF THIS ACCEPTANCE
NOA No.:20-0701.02
LMMIAMMIMADMEMOUNTY Expiration Date: 12/01/25
=' I Approval Date: 11/05/20
Page 7 of 7