Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL PANEL WALL SIDING
Florida Building Code Online Page 1 of 3 ' BCIS Home Log In User Registration Hot Topics Submit Surcharge j Stats&Facts Publications Contact Us BCIS Site Map Links Search AM4 (F`o"Cd I Product Approval - USER:Public User - Product Approval Menu>Product or Aoolica[ion Search>Application list>Application Detail File COPY FL# FL13192-R6 fiNEWED x VApplication Type Revision FOR Cade Version 2020 Application Status Approved CODE COMPLIANCE Comments ST. LUCIE COUNTY Archived A30CCt/Z1j?,?,, Product Manufacturer James Hardie Building Products Address/Phone/Email 10901 Elm Ave Fontana,CA 92337 (909)641-0498 rathisha.sabaratnam@jhresearchusa.com Authorized Signature Rathisha Sabaratnam rathisha.sabaratnam@jhresearchusa.com Technical Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue .-Fontana,CA 90631 (909)641-0498 rathisha.sabaratnam@jhresearchusa.com Quality Assurance Representative Rathisha Sabaratnam Address/Phone/Email 10901 Elm Avenue Fontana,CA 92337 (909)614-0498 rathisha.sabaratnam@jhresearchusa.com Category Panel Walls Subcategory Siding Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed V.Andrew Tan the Evaluation Report Florida License PE-81662 Quality Assurance Entity Intertek Testing Services NA,Inc. -QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By John Southard,P.E. R Validation Checklist-Hardcopy Received Certificate of Independence FL13192 R6 COI 200 1-10 Letter of Indenendence.ndf Referenced Standard and Year(of Standard) Standard Year ASTM C1186 2012 ASTM E330 2002 Equivalence of Product Standards Certified By Sections from the Code https://www.floridabuilding.org/pr/Pr_app—dti.aspx?param=wGEV XQwtDqtsk%2bGnUu4..., 1/21/2022 Florida Building Code Online Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 12/14/2020 Date Validated 01/05/2021 Date Pending FBC Approval 01/06/2021 Date Approved 02/09/2021 Summary of Products FL# Model,Number or Name Description 13192.1 Cemplank Lap Siding fiber-cement lap siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13192 R6 II 2001-10.2.1 HardiePlank Analvsis.odf Approved for use outside HVHZ:Yes FL13192 R6 II 2001-10.2.2 HardiePlank over WSP Impact Resistant:N/A Analvsis.nddf Design Pressure:N/A FL13192 R6 H 2001-10.2.3 Plank Shingle over CMU Other:For use in HVHZ install in accordance with Miami- Analysis.pd Dade County Florida NOA 20-0730.06;for use outside HVHZ FL1.3192 R6 11 2001-14:3 NOA Hardie Plank-Panel- install in accordance with manufacturer's installation Soffit.odf instructions. FL13192 R6 II CemPlank-Install-Instr .pdf Verified By: V.Andrew Tan 81662 Created by Independent Third Party: No Evaluation Reports FL13192 R6 AE 2001-10.2.1 HardiePlank Analysis.pdf FL13192 R6 AE 2001-10.2.2 HardiePlank over WSP Analvsis.ndf FL13192 R6 AE 2001-10.2.3 Plank Shingle over CMU Anaivsispdf FL131.92 R6 AE 2001.-14.3 NOA Hardie Plank-Panel- Soffit.Ddf Created by Independent Third Party: Yes 13192.2 HardiePlank Lap Siding fiber-cement lap siding Limits of Use Installation Instructions Approved for us 'n HV�e FL13192 R6 II 2001-10.2.1 HardiePlank Analvsis.pdf Approved for use outside HVHZ:Yes FL13192 R6 II 2001.-10.2.2 HardiePlank over WSP Impact Resistant:N/A Analysis.pdf Design Pressure:N/A FL13192,_R5 II 2001,-7.(l,,_2_ _P!ank ShinglQ_oyer CMU. Other:For use in HVHZ install in accordance with Miami- Anah5is.pddf Dade County Florida NOA 20-0730.06; for use outside HVHZ FI.i3192 R6 lI 2001 14.3 NOA Hardie Plank-Panel- install in accordance with manufacturer's installation Soffit pdf instructions. FL13192 R6 11 HardiePlank-Install-Instr .pdf Verified By: V.Andrew Tan 81662 Created by Independent Third Party: No Evaluation Reports FL13192 R6 AE 2001-10.2.1 HardiePlank Analvsis.pdf FL131.92 R6 AE 2001-10.2.2 HardiePlank over WSP Analysis.pdf FL13192 R6 AE 2001-10_2.3 Plank Shingle over CMU Analysis.pdf FL13192 R6 AE 2001-14.3 NOA Hardie Plank-Panei- Soffit.pdF Created by Independent Third Party:Yes 13192.3 HardieShingle Individual Shingles fiber-cement individual cladding shingles Limits of Use Installation Instructions Approved for use in HVHZ:No FL13192 R6 II 2001-10.2.4 HardieShingle Analysis.odf Approved for use outside HVHZ:Yes FL13192 R6 11 HardieShinn le-Install-Instr .pdf Impact Resistant:N/A Verified By: V.Andrew Tan 81662. Design Pressure:N/A Created by Independent Third Party: No Other: Evaluation Reports FL13192 R6 AE 2001-10.2.4 HardieShingle Analysis.pdf Created by Independent Third Party: Yes 13192.4 HardieShingle Panel fiber-cement notched shingle panels(straight edge, staggered edge,half round edge) Limits of Use Installation Instructions Approved for use in HVHZ: No FL1.3192 R6 fI 2001.-10.2.3 Plank Shingle over CMU Approved for use outside HVHZ:Yes Analysis.odf Impact Resistant:N/A FL13192 R6 II 2001-1.0.2.4 HardieShingle Analysis.Ddf Design Pressure:N/A FL13192 R6 II HardieShingle-Install-Instr .pdf Other: Verified By:V.Andrew Tan 81662 Created by Independent Third Party: No Evaluation Reports FL13192 R6 AE 2001-10 2.3 Plank Shingle over CMU �na�sis;pdf https://www.floridabuilding.org/pr/pr_app—dtl.aspx?param=wGEVXQwtDgtsk%2bGnUu4... 1/21/2022 Florida Building Code Online Page 3 of 3 FL13192_R6 1E 2001_�112.4 Hardie5hingle Analysis.pdf. Created by Independent Third Party:Yes 13192.5 Prevail Lap Siding fiber-cement lap siding Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13192 R6'II 2001-10.2.1 HardiePlank Analvsis.odf Approved for use outside HVHZ:Yes FL13192 R6 II 2001-10.2.2 HardiePlank over WSP Impact'Resistant:N/A Analvsis.pdf Design Pressure:N/A FL13192 R6 1I 2001-10.2.3 Plank Shingle over CMU Other:For use in HVHZ install in accordance with Miami- Anaivsis.pdf Dade County Florida NOA 20-0730.06; for use outside HVHZ FL131.92 R6 I1 2001-1.4.3 NOA Hardie Plank-Panel- install in accordance with manufacturer's installation Soffit.Ddf instructions. FL13192 R6 11 Prevail-Lao-Siding-Instal)-Instr.pdf Verified By:V.Andrew Tan 81662 Created by Independent Third Party: No Evaluation Reports FL13192 R6 AE 2001-10.2.1 HardiePlank Analvsis.ndf FL13192 R6 AE 2001-10.2.2 HardiePlank over WSP Analvsis.pdf FL13192 R6 AE 2001-10.2.3 Plank Shingle over CMU Ana lysis.pdf FLI.3192 R6 AE 2001-14.3 NOA Hardie Plank-Panel- Soffit.odf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided maybe used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S„please click here. Product Approval Accepts: ® E9 M. Credit Carr Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtsk%2bGnUu4..,. 1/21/2022 Florida Product Approval HardiePlank° Lap Siding • For use inside HVHZ: o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with the Miami-Dade County Florida NOA 07- 0418.04. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. • For use outside of HVHZ, o HardiePlank Lap Siding fastener types, fastening schedule, and installation shall be in accordance with Engineering Evaluation Reports RIO-2298-11 or RIO-2300-11. Consult the HardiePlank product installation instructions on the follow pages for all other installation requirements. RECEIVED JAN 18 2022 St.Lucie County Permitting �p JamesHardie HardiePlank'/r-�Z® Lap Siding EFFECTIVE NOVEMBER 2010 IM INSTALLATION REQUIREMENTS -PRIMED&COLORPLUS° PRODUCTS Visit www..iameshardie.com for the most recent version. SELECT CEDARMILL© -SMOOTH-COLONIAL SMOOTH®-COLONIAL ROUGHSAWN®-BEADED CEDARMILL© BEADED SMOOTH-STRAIGHT-EDGE SHINGLE PLANK IMPORTANT.FAILURE TO INSTALL AND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY,AFFECT SYSTEM PERFORMANCE,VIOLATE LOCAL BUILDING CODES,AND VOID THE PRODUCT ONLY WARRANTY.BEFORE INSTALLATION,CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONETM PRODUCT INSTRUCTIONS. INSTALLATION OF HZ100 PRODUCTS OUTSIDE AN HZ100 LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONETM APPLIES TO YOUR LOCATION,VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343(866 9HARDIE) STORAGE&HANDLING: © CUTTING INSTRUCTIONS Store flat and keep dry and OUTDOORS INDOORS covered prior to installation.Installing 1.Position cutting station so that wind will blow dust away from user 1.Cut only using scare and snap,or shears(manual,electric or pneumatic). and others in working area. 2.Position cutting station in well-ventilated area siding wet or saturated may result in 2.use one of the following methods: shrinkage at butt joints.Carry planks a.Best: i.Score and snap ii.Shears(manual,electric or pneumatic) -NEVER use a power saw indoors on edge. Protect edges and corners b.Better: i.Dust reducing circular saw equipped with a -NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark from breakage.James Hardie is not HardieBlade°saw blade and HEPA vacuum extraction NEVER dry sweep-Use wet suppression or HEPA Vacuum responsible for c.Good: I.Dust reducing circular saw with a HardieBlade saw blade reS P (only use for low to moderate cutting) damage caused by improper Important Note:For maximum protection(lowest respirable dust production),James Hardie recommends always using"Best"-level cutting methods where feasible. storage and NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures.Additional exposure information is available at www.jameshardie.com to help you determine the most appropriate cutting method for your job requirements.9 concern still exists about exposure levels or you handling of the produl. do not comply with the above practices,you should always consult a qualified industrial hygienist or contact James Hardie for further information. soosaros GENERAL REQUIREMENTS: • HardiePlank®lap siding can be installed over braced wood or steel studs spaced a maximum of 24"o.c.or directly to minimum 7/16"thick OSB sheathing. Irregularities in framing and sheathing can mirror through the finished application. • HardiePlank®lap siding can also be installed over foam insulation/sheathing up to 1"thick.When using foam insulation/sheathing,avoid over-driving nails (fasteners),which can result in dimpling of the siding due to the compressible nature of the foam insulation/sheathing.Extra caution is necessary if power-driven nails(fasteners)are used for attaching siding over foam insulation/sheathing. • A water-resistive barrier is required in accordance with local building code requirements.The water-resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements.James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap®Weather Barrier,a non-woven non-perforated housewrapl,which complies with building code requirements. • When installing James Hardie products all clearance details in figs.3,4,5,6,7,8,&9 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building Figure 1 Double Wall Single Wall codes-typically a minimum of 6"in the first 10'. construction construction • Do not use HardiePlank lap siding in fascia or trip applications, water-resistive barrier let-in bracing • Do not install James Hardie products,such that they may remain in contact with standing water plywood or 24"o.c.max. • HardiePlank lap siding may be installed on flat vertical wall applications only. OSB sheathing • For larger projects,including commercial and multi-family projects,where the span of the wall is significant in length,the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin"Expansion Characteristics of James Hardie"Siding Products"at www.JamesHardie.com. • DO NOT use stain on James Hardie®products. INSTALLATION: JOINT TREATMENT" (Required for ColorftsO Finish,Recommended for Primed product) James Hardie does not recommend the use of caulk at field butt joints. water-resistive stud Install facto finished edges Figure 2 barrier together t butt joints9 ��wiwww1"from ° o� 00 plank p - ° °joint flashing — ° ° 3/8"from _ i plank °water-resistive install planks in °°O - barrier ° moderate contact - o° oo 0 ° fastener - ° o 0 - o Install a 1 1/4"starter strip to 0 0 o ensure a consistent plank angle 'For other jointing options,refer to local building code or NER 405 0 0 "As required by local building code "'Apply caulk in accordance with caulk manufacturers written application instructions. leave appropriate gap between For additional information on HardieWrap°Weather Barrier,consult James Hardie at 1-866-4Hardie or www.hardiewrap.com planks and trim,then caulk"' WARNING:AVOID BREATHING SILICA DUST James Hardie®products contain respirable crystalline silica,which is known to the State of Califomia to cause cancerand is considered by IARC and NIOSH to bee cause of cancer from some occupational sources.Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis,and has been linked with other diseases.Some studies suggest smoking may increase these risks. During installation or handling:(1)work in outdoor areas with ample ventilation;(2)use fiber cement shears for cutting or,where not feasible,use a HardieBlade®saw blade and dust-reducing circular saw attached to a HEPA vacuum;(3)warn others in the immediate area;(4)wear a propedy-fitted,NIOSH-approved dust mask or respirator(e.g.N-95)in accordance with applicable government regulations and manufacturer instructions to further limit respirable silica exposures. During clean-up,use HEPA vacuums or wet cleanup methods-never dry sweep. For further information,refer to our installation instructions and Material Safety Data Sheet available at www.jameshardle.com or by calling 1-800-9HARDIE(1-800-942-7343). FAILURE TO ADHERE TO OUR WARNINGS,MSDS,AND INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL INJURY OR DEATH. 5°65M HS0920-P1/4 10/10 y 19C ME CLEARANCES At the juncture of the roof and vertical Maintain a 1" 2"clearance between surfaces,flashing and counterflashing shall Install siding and trim products in compliance James Hardie products and decking be installed per the roofing manufacturer's with local building code requirements for clearance between the bottom edge of the Maintain a 1"-2"clearance material. instructions.Provide a 1"-2"clearance siding and the adjacent finished grade. between James Hardie' Figure 5 between the roofing and the bottom edge of products and paths,steps the siding and trim. siding water Figure 3 stud and driveways. g resistive Figure 6 water-resistive barrier g r barrier —- Figure 4 /�1"-2" I'° deck material concrete 1 2" foundation 1"-2" 0 I joist flashing ledger a HardiePlank® , 'flashing " "r'Inf lap siding Figure Step flashing/`,; / KICKOUT FLASHING Maintain a 1/4"clearance Maintain a minimum 1"gap Because of the volume of water that can pour down between the bottom of James between gutter end caps and Smarn cane + a sloped roof,one of the most critical flashing membrane Hardie products and horizontal siding&trim. f `ga ,1 details occurs where a roof intersects a sidewall. flashing.Do not caulk gap. Figure 8 +f !eavelsmemtitagne The roof must be flashed with step flashing. Where ' '��°°' � the roof terminates,install a kickout to deflect water Flashing Figure 7 10 �dp edge away from the siding. r Caulk siding It is best to install a self-adhering membrane on the I Do not va"gap siding �' ousevrtap wall before the subfascia and trim boards are nailed C j .- _ in place,and then come back to install the kickout. ~ Figure 9,Kickout Flashing$To prevent water from dumping behind the siding and the flashingfascia end of the roof intersection,install a"kickout"of sufficient length and angle to direct the gutter and end cap water running down the roof away from the siding. FASTENER REQUIREMENTS ** Blind Nailing is the preferred method of installation for all HardiePlank®lap siding products BLIND NAILING FACE NAILING Nails-Wood Framing Nails-Wood Framing •Siding nail(0.09"shank x 0.221"HD x 2"long) •6d(0.113"shank x 0.267"HD x 2"long) •11 ga.roofing nail(0.121"shank x 0.371"HD x 1.25"long) •Siding nail(0.09"shank x 0.221"HD x 2"long) Screws-Steel Framing Screws-Steel Framing •Ribbed Wafer-head or equivalent(No.8 x 1 1/4"long •Ribbed Bugle-head or equivalent(No.8-18 x 1-5/8"long x x 0.375"HD)Screws must penetrate 3 threads into metal framing. 0.323"HD)Screws must penetrate 3 threads into metal framing. Nails-Steel Framing Nails-Steel Framing •ET&F Panelfast°nails or equivalent(0.10"shank x 0.313"HD x 1-1/2"long) •ET&F pin or equivalent(0.10"shank x 0.25"HD x 1-1/2"long) Nails must penetrate minimum 1/4"into metal framing. Nails must penetrate minimum 1/4"into metal framing. 0S13 minimum 7116" OSB minimum 7/16" •11 ga.roofing nail(0.121"shank x 0.371"HD x 1,75"long) •Siding nail(0.09"shank x 0.221"HD x 1-1/2"long)* •Ribbed Wafer-head or equivalent(No.8 x 1 5/8"long x 0.375"HD). stud 24"----------------------- O.C.max. stud 24" Figure 10 Figure 11 1 1/4"min. water-resistive Minimum overlap �—O.C.max. overlap I barrier ° for Both Face y ' of and Blind Nailing ; y I blind nail ——" ° 3/4"-l" I ° I I ° min.1 1/4" ° face nail 0 overlap I l f I I I I I water-resistive water-resistive barrier 1 1/4"min. barrier overlap Laminate sheet to be removed immediately after installation of each course for ColorPlus®products. t The illustration(figure 9)and associated text was reprinted with permission of THE JOURNAL OF LIGHT CONSTRUCTION.For subscription information,visit www.jiconline.com. * When face nailing to OSB,planks must be no greater than 91/4"wide and fasteners must be 12"o.c.or less. '*Also see General Fastening Requirements;and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 17-Fastening Tips for HardiePlank®Lap Siding. HS0920-P2/4 10/10 GENERAL FASTENING REQUIREMENTS •Consult applicable code compliance report for correct fasteners type and Fasteners must be corrosion resistant,galvanized,or stainless steel. placement to achieve specified design wind loads. Electro-galvanized are acceptable but may exhibit premature corrosion. •NOTE:Published wind loads may not be applicable to all areas where James Hardie recommends the use of quality,hot-dipped galvanized Local Building Codes have specific jurisdiction.Consult James Hardie nails. James Hardie is not responsible for the corrosion resistance of Technical Services if you are unsure of applicable compliance documentation. •Drive fasteners perpendicular to siding and framing. fasteners, Stainless steel fasteners are recommended when installing •Fastener heads should fit snug against siding(no air space).(fig.A) James Hardie®products near the ocean,large bodies of water,or in •Do not over-drive nail heads or drive nails at an angle. very humid climates. •If nail is countersunk,caulk nail hole and add a nail.(fig.B) PNEUMATIC FASTENING •For wood framing,under driven nails should be hit flush to the plank with a James Hardie products can be hand nailed or fastened with a pneumatic tool, hammer(For steel framing,remove and replace nail). Pneumatic fastening is highly recommended. Set air pressure so that the •Do not use aluminum fasteners,staples,or clipped head nails. fastener is driven snug with the surface of the siding.A flush mount Snug Flush 571 attachment on the pneumatic tool is recommended. This will help control the Countersunk, depth the nail is driven.If setting the nail depth proves difficult,choose a ® ® add Caulk a& (B 0 setting that under drives the nail. (Drive under driven nails snug with a IsLi do not under DO NOT smooth faced hammer-Does not apply for installation to steel framing). Figure A Figure B drive nails STAPLE CAULKING PAINTING For best results use an Elastomeric Joint Sealant complying DO NOT use stain on James Hardie®products.James Hardie products must be with ASTM C920 Grade NS,Class 25 or higher or a Latex painted within 180 days for primed product and 90 days for unprimed.100% Joint Sealant complying with ASTM C834.Caulking/Sealant acrylic topcoats are recommended. Do not paint when wet.For application rates must be applied in accordance with the caulking/sealant refer to paint manufacturers specifications.Back-rolling is recommended if the manufacturer's written instructions or ASTM C1193. siding is sprayed. COLORPLUS®TECHNOLOGY CAULKING,TOUCH-UP&LAMINATE •Touch up nicks,scrapes and nail heads using the ColorPlus°Technology touch-up applicator.Touch-up paint should be used sparingly. If large areas require touch-up,replace the damaged area with new HardiePlane lap siding with ColorPlus Technology. •Laminate sheet must be removed immediately after installation of each course. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPlu0 product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer. PAINTING JAMES HARDIE@ SIDING AND TRIM PRODUCTS WITH COLORPLUS®TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application: •Ensure the surface is clean,dry,and free of any dust,dirt,or mildew •Repriming is normally not necessary •100%acrylic topcoats are recommended •DO NOT use stain or oil/alkyd base paints on James Hardie,,products •Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature COVERAGE CHART/ESTIMATING GUIDE Number of 12'planks,does not include waste COVERAGE AREA LESS OPENINGS HARDIEPLANK®LAP SIDING WIDTH SQ 51/4 61/4 7114 71/2 8 81/4 91/4 9112 12 (1 SQ=100 sq.ft.) (exposure) 4 5 6 61/4 6 3/4 7 8 81/4 10 3/4 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 19 475 380 317 304 281 271 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide.Actual usage is subject to variables such as building design.James Hardie does not assume responsibility for over or under ordering of product. RECOGNITION: In accordance with IMES Legacy Report NER-405,HardiePlank'lap siding is recognized as a suitable alternate to that specified in:the BOCA National Building Code/1999,the 1997 Standard Building Code,the 1997 Uniform Building Code,the 1998 International One-and Two-Family Dwelling Code,the 2003 International Building Code,and the 2003 International Residential Code for One-and Two- Family Dwellings.HardiePlank lap siding is also recognized for application in the following:City of Los Angeles Research Report No.24862,State of Florida listing FL#889,Dade County,Florida NOANo.02-0729.02, U.S.Dept.of HUD Materials Release 1263c,Texas Department of Insurance Product Evaluation EC-23,City of New York MEA 223-93-M,and California DSA PA-019.These documents should also be consulted for additional information concerning the suitability of this product for specific applications. HS0920-P3/4 10110 M. ©2010 James Hardie Technology Limited.All rights reserved. Additional Installation Information, TM,SM,and®denote trademarks or registered trademarks of James Hardie Technology Limited.[Ms a registered trademark Warranties,and Warnings are available at James Hardie of James Hardie Technology Limited. www.jameshardle.com Panelfast is a registered trademark of ET&F Fastening Systems,Inc. HS0920-P4/4 10/10