Loading...
HomeMy WebLinkAboutRoofing Information Sheet ' I . I I ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEETPi �e �® Py Florida Building Code 7th Edition (2020) I Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET I APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: I Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150. A,B,C 2,4,5,6,7 I ' Asphaltic Shingles A,B,D 1,2,4,5,6,71 Concrete or Clay Tile A,B,D,E Metal Roofs A,B,D 1,2,3,4,5,fi,T Wood Shingles and A,B,D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): , 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations a Applicable Detail Drawings I I 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS 128 4. Other Component of Product Approval i 5. Municipal Permit Application I _ 6. Owners Notification for Roofing Considerations(Reroofing Only) I 7. Any Required RoofTestiing/Calculation Documentation r - ' I T>. LUCIE WORK. S Section A(General Information) d Master Permit No. Process No. Contracto rs Name: CwL License# C Job Address 3/ S �-6 G"`' 3V� S ROOF CATEGORY - ❑Low Slope ❑Mechanically Fastened Tile ❑M o rta r/Ad h es ive 6et Tiles ❑Asphaltic Shingles ❑Metal.Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 i ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑Recovering ROOF SYSTEM INFORMATIONV,d Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) 7V Total(SF) • I Section B(Roof Plan) Sketch Roof Plan: Illustrate, all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. y � i y i 1 � I ! l o , it jy. ' i I t ) I i I r f a I n I I i r I i Page#5: Edge Length 13125 S Indian River Dr Jensen Beach FL 34957 USA 400�X4 NIL 000,07 rccfcrdersccm ROOF PLANS FROM AERIAL IMAGERY Edge Length Summary Edge Type `' Length(Ft) Eave 228.94 .:> Rake 140.46 Hip 25.27P-' Valley 57.71 � Ridge 81.30 ;sue 0 StepFlashing 8.52 ApronFlashing 103.61 SlopeTransition 0.00 � ----�`� sZ 0'M m Roof Area Summary ` Pitch Area(Sq Ft) ®�:� 4112 345 N• . 6/12 2307 8/12 1390 �� _-Total- 4042 . r PaffN .'.: RESTORATION&SERVICES w ® LUCIE WORKS ICI I I I Section D(Steep Slope Roof System)^ Roof System Manufacturer: CJ ' Notice of Acceptance Number: c ! r� Minimum Design Wind Pres ures,If Applicable(From RAS 127 or Calculations): Zone 1: Zone 2e: Zone Zn: Zone 2rZone 3�ione 3r: —H Deck Type: Type Underlayment .A Roof Slope: 08 12 insulation: Fire Barrier: g - I Ridge Ve it lion? Fastener Type&Spacing: E. I' I Adhesive Type: r� o - I I Type Cap Sheet rc •l�3 �' 'i"' Mean Roof Height: 3� Roof Covering: G Type&Size Drip Edge: i I '• I ; I 9 I T LUCIE \A/0 Section E(Tile Calculations) i For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mr.If the Mr values are greater than or equal to the Mrvalues,for each area'of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x X_ !M =I,{I Product Approval Mi (Zone 2e: x X. _) im =� Product Approval Mf (Zone 2n: x'l-= Product Approval Mf { �.-;Mg;. =I� (Zone 2r: -x .-= _�-IMg: _( Product Ipproval Mf i (Zone 3e: x l- -)_ -NIT -Mr, Product Approval Mf (Zone 3r. x .- M.B: =� Pro uct Approval M f Method 2"Simplified Tile Calculations Per Table Below" Required.Moment of Resistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 142.2 3:12 32.2 34.4 36.0 37.4 139. 4:12 30.4 32.2 33.8 35.1 5:12 28.4 30.1 31.6 32.8 134.9 6:12 26.4 28.0 29.4 1 30 32.4 7:12 . 24.4 25.9 27.1 28.2 130.0 *Must be used in conjunction with a ' t f m%enase the systems ' i • For Uplift based the systems use Meth 3. e t values for F' ith the values for Fr If the F'values are greater than or equal to the Fr values,for each area oft a ro t e the att ment method is acceptable. Meth d 3"Uplift Based a Calculations Per RAS 12T (Zone 1: x L =x W:= )- co =Fr1 Product Approval F' I (Zone 2e: x L =x W:= ) cos r =Frze Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2 NProduct oval F' { (Zone 2r: x L =x W:= ) cos r =Fr2r oval F' (Zone 3e: x L =x W:= -W: cos r =Fr3e oval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r oval F' I Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1,2e,2n,2r,3e,3r From applicable to in RAS 127 or by an engineering analysis prepared by PE base on ASCE 7 Mean Roof Heig H Job Site i Roof Slope 6 Job Site Aerodyna ultiplier a Product Approval Restoring Moment due to Gravity Mg Product Approval ? Attachment Resistance Mf Product Approval { Required Moment Resistance Mg Calculated I Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W -Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application. i I i 1 ' p T I 'VIJOR.K Section C(Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1': oc @ Lap,#Rows"@_°ac (If a component is not used,identify as"NA") Zone 1_. "oc @ Lap,#Rows-@-OC System Manufacturer: Zone 2s oc @ IiLap,#Rows @ °ao Zone 3_"oc @!Lap,#Rows!@-G Product Approval No.: Number of Fastener)Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone V: Zone 1: Zone 2: Zone 3: Zone 1':_Zone 1: Zone 2:_Zone 3: Illustrate Components No tl and Details as Applicable: Max. Design Pressure,from the specific product approval Woodblocking, Gutt Edge Termination, Stripping, system: Flashing, Continu s Cleat, Cant Strip,. Base Flashing, Counterflashin ,Coping,Etc., Deck: Indicate: M n Roof Height, Parapet Height, Height of Base Type: Flashing omponent Material,Material'Thickness,Fastener Type astener Spaciing or Submit Manufacturers Details that Gauge Thickness: C ply with RAS 111 and Chapteril6.. Slope: I Anchor/Base Sheet&No.df Ply(s): Anchor/Base Sheet Fastener/Bonding Mater : FT. Insulation Base Layer: Base Insultation Size and Thickness: Parapet Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding aterial: Mean Base Sheet(s)&No.of/ing Roof Base Sheet Fastener/Baterial: Height Ply Sheet(s)'&No.of`P y s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: i a