Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 2-21-13"FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Projett Name: JOE AND ANN HAMROCK Builder Name: L & C CONST. Street: 10725 S OCEAN DR. LOT 323 Permit Office: st. lucie co. / ft. pierce City, State, Zip: JENSEN BCH. , FL , 34957- Permit Number. Owner. SAME Jurisdiction: 661100 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2254.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1958.10 1112 b. Frame - Wood, Exterior R=11.0 296.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft 10. Ceiling Types (1704.0 sgft.) Insulation Area 5. Is this a worst case?' No a. Cathedral/Single Assembly (Unvented) R=20.0 1704.00 ft2 6. Conditioned floor area above grade (ft2) 1704 b. WA R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(308.1 sgft.) :. . Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 164 a. U=Factor. •Sgi,• U=0.56 308.10 ft2 SHGC: SHGC=0.50 b. U-Factor. N/A � 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 28.6 SEER:15.25 c. U-Factor. N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency. d. U-Factor. N/A ft2 a. Electric Strip Heat 28.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 3.107 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems a. Electric Cap: 66 gallons 8. Floor Types (1704.0 sgft.) Insulation Area EF: 0.920 a. Raised Floor R=20.0 1704.00 ft2 b. Conservation features b. WA R= ft2 None c. WA R= ft2 15. Credits CF, WHF, Pstat Glass/Floor Area: 0.181 Total Proposed Modified Loads: 42.08 PASS Total Standard Reference Loads: 52.42 I hereby certify that the plans and specifications covered by Review of the plans and JOE S?.qp� this calculation are in compliance with the Florid nergy specifications covered by this o� • ' = 0 Code. calculation indicates compliance with the Florida Energy Code. F• rarrr'�. PREPARED BY: 4�C/ Before construction is completed ` - DATE: this building will be inspected for compliance with Section 653.908 * k�IW. I hereby certify that_thisZiildinfg, as designed, is in compliance Florida Statutes. with the Florida Ene y Co COD WE'D OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Compliance requires a roof absorptance test in accordance with 405.6.2 2112/201311:01 AM EnergyGauge® USA - FlaRes2010 Section 405A.1 Compliant Software Page 1 of 6 PROJECT i. Title: Building Type: y Owner. # of Units: Build(jr Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: JOE AND ANN HAMROCK Bedrooms: 3 User Conditioned Area: 1704 SAME Total Stories: 2 1 Worst Case: No L & C CONST. Rotate Angle: 0 st. lucie co. / ft. pierce Cross Ventilation: No 661100 Whole House Fan: Yes Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 10 10725 S OCEAN DR. L st. lucie JENSEN BCH. , FL, 34957- CLIMATE Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL ST LUCIE CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 1704 13632 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1704 13632 Yes 2 3 1 Yes Yes Yes FLOORS # Floor Type Space R Value Area Tile Wood Carpet 1 Raised Floor Main _ r 1704 ft2 20 0.5 0.5 0 ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 1748 ft2 0 ft2 Unfinishe 0.96 Yes 0.7 No 20 12.9 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1704 ft2 N N CEILING # Ceiling Type Space R Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvented Main 20 1704 ft2 0.11 Wood i WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Omt To Wall Type Space " 1 N Exterior Concrete Block - Int Insul Main 4 17 0 9 7 162.9 ft2 0 0 0.75 0 2 N Exterior Concrete Block - Int Insul Main 4 9 0 8 0 72.0 ft2 0 0 0.75 0 3, E Exterior Concrete Block - Int Insul Main 4 44 3 9 7 424.1 ft2 0 0 0.75 0 4 E Exterior Concrete Block - Int Insul Main 4 10 8 80.0 ft2 0 0 0.75 0 5 E Exterior Concrete Block - Int Insul Main 4 32 9 7 306.7 ft2 0 0 0.75 0 6 S Exterior Concrete Block - Int Insul Main 4 32 9 7 306.7 ft2 0 0.75 0 7 S Exterior Concrete Block - Int Insul Main 4 27 8 0 216.0 ft2 0 0 0.75 0 8 W Exterior Concrete Block - Int Insul Main 4 10 9 7 95.8 ft2 0 0 0.75 0 9 W Exterior Concrete Block - Int Insul Main 4 19 4 8 0 154.7 ft2 0 0 0.75 0 10 W Exterior Concrete Block - Int Insul Main 4 6 8 0 48.0 ft2 0 0 0.75 0 11 W Exterior Concrete Block - Int Insul Main 4 11 5 8 0 91.3 ft2 0 0 0.75 0 12 W Exterior Frame - Wood Main 11 37 8 296.0 ft2 0.23 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main Wood 0.460000 3 0 6 8 20 ft2 2 E Wood Main Metal 0.460000 3 0 6 8 20 ft2 3 W Wood Main Wood 0.460000 3 0 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Tinted) Yes 0.56 0.5 14.0 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 2 E 3 Metal Single (Tinted) Yes 0.56 0.5 46.4 ft2 1 ft 0 in 10 It 1 in Drapes/blinds None 3 E 4 Metal Single (Tinted) Yes 0.56 0.5 46.4 ft2 8 ft 0 in 0 ft 9 in Drapes/blinds None 4 E 5 Metal Single (Tinted) Yes 0.56 0.5 32.4 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 5 E 5 Metal Single (Tinted) Yes 0.56 0.5 46.4 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 6 S 6 Metal Single (Tinted) Yes 0.56 0.5 30.3 ft2 1,ft 0 in 10 ft 1 in Drapes/blinds None 7 S 7 Metal Single (Tinted) Yes 0.56 0.5 6.9 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None 8 W 8 Metal Single (Tinted) Yes 0.56 0.5 46.4 ft2 8 It 0 in 10 ft 1 in Drapes/blinds None 9 W 9 Metal Single (Tinted) Yes 0.56 0.5 19.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None 10 W 11 Metal Single (Tinted) Yes 0.56 0.5 19.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None GARAGE # FloorArea Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280.8 ft2 191 ft2 31 ft 13 ft 11 INFILTRATION r # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000300 1340.8 73.612 138.43 0.2696 5.9017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts (lnvaliElectric Strip Heat None COP: 1 28 kBtu/hr 1 sys#0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds (InvaliCentral Unit None SEER: 15.2528.6 kBtu/hr 858 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 66 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — # Location R-Value Area — Return — Air CFM25 Location Area Leakage Type Handler CIfKM5 OUT QN RLF HVAC # Heat Cool onvali Attic 6 164 ft2 Attic 41 ft2 Default Leakage Main (invalid) c (Default) No 1 TEMPERATURES Programable Thermostat: Y Conlin Jan Feb Mar Venting X Jan Feb X Mar Ceiling Fans: r Ma Jun [�Xjj Jul Auge Oct Nov pr RiMay Jun pC] Jul Aug Sep Occtt Nov Jun [[XXjj Jul Aug Sep J Dec Dec Thermostat Schedule: HERS 2006 Reference Hours t.Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 780 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 - 0% 1- Central Unit 0 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10725 S OCEAN DR. LOT 323 PERMIT #: JENSEN BCH., FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4- Heat trap required for vertical pipe risers. Comply with efficiencies in / Table 403.4.3.2. Provide switch or clearly marked circuit breaker / (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 ���/// + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical / ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages. or outdoors adjacent r/ to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. I