Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 3-15-13FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JOE AND ANN HAMROCK redesign Builder Name: L & C CONST. Street: 10725' S OCEAN DR. LOT 323 Permit Office: st. lucie co. / ft. pierce City, State, Zip: JENSEN BCH. , FL, 34957- Permit Number. Owner. SAME Jurisdiction: 661100 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2156.6 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1860.60 ft2 b. Frame - Wood, Exterior R=11.0 296.00 f12 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. WA R= ft2 10. Ceiling Types (1142.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1142.00 ft2 6. Conditioned floor area above grade (ft2) 1603 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(230.2 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 164 a. U-Factor. Sgl, U=0.56 230.24 ft2 SHGC: SHGC=0.50 � 12. Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a. Central Unit 28.6 SEERA5.25 SHGC: c. U-Factor. NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 28.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 4.023 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems a. Electric Cap: 66 gallons 8. Floor Types (1603.0 sgft.) Insulation Area EF: 0.920 a. Raised Floor R=20.0 1603.00 ft2 b. Conservation features b. WA R= ft2 None c. N/A R= ft2 16. Credits CF, WHF, Pstat 0.144 Total Proposed Modified Loads: 37.38 PASS Glass/Floor Area: Total Standard Reference Loads: 49.42 I hereby certify that the plans and specifications covered by Review of the plans and O'V THE STg1A this calculation are in compliance with the Flo ' a Energy Code. specifications covered by this calculation indicates compliance ,y = Off, with the Florida Energy Code. n+1rr'� . PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 „�� F a * rr I hereby certify that s building, as designed, is in compliance Florida Statutes. COb with the Florida En gy C e. WE'D OWNER/AGEN, . BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Compliance requires a roof absorptance test In accordance with 405.6.2 3/11/2013 7:18 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software - Page 1 of 5 PROJECT Title: Building Type: Owner. # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/EAsting: Comment: JOE AND ANN HAMROCK re Bedrooms: 3 User Conditioned Area: 1603 SAME Total Stories: 2 1 Worst Case: No L & C CONST. Rotate Angle: 0 st. lucie co. / ft. pierce Cross Ventilation: No 661100 Whole House Fan: Yes Single-family New (From Plans) Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Street Address 10 10725 S OCEAN DR. L st. lucie JENSEN BCH. , FL, 34957- CLIMATE V Design Location IECC Design Temp TMY Site Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Piero FL ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1603 12824 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID. Finished Cooled Heated 1 Main 1603 12824 Yes 2 3 1 Yes Yes Yes FLOORS # Floor Type Space R-Value Area Tile Wood Carpet 1 Raised Floor Main — — 1603 ft2 20 0.5 0.5 0 ROOF # Roof Gable Roof Type Materials Area Area Color Solar Absor. SA Emitt Tested Emift Deck Pitch Tested Insul. (deg) 1 Hip Metal 1645 ft2 0 ft2 Unfinishe 0.96 Yes 0.7 No 20 12.9 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1603 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 20 1142 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below R-Alaille Et In Et In Area R--Vaille Fraction Ahqor Grade-OA 1 N Exterior Concrete Block - Int Insul Main 4 15 5 9 7 147.7 ft2 0 0 0.75 0 2 E Exterior Concrete Block - Int Insul Main 4 42 7 9 7 408.1 ft2 0 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 4 31 9 8 254.0 ft2 0 0 0.75 0 4 E Exterior Concrete Block - Int Insul Main 4 14 4 8 0 114.7 ft2 0 0 0.75 0 5 S Exterior Concrete Block - Int Insul Main 4 27 2 9 7 260.3 ft2 0 0.75 0 6 S Exterior Concrete Block - Int Insul Main 4 29 11 9 7 286.7 ft2 0 0 0.75 0 7 W Exterior Concrete Block - Int Insul Main 4 11 2 9 7 107.0 ft2 0 0 0.75 0 8 W Exterior Concrete Block - Int Insul Main 4 16 8 8 0 133.3 ft2 0 0 0.75 0 9 N Exterior Concrete Block - Int Insul Main 4 8 1 8 0 64.7 ft2 0 0 0.75 0 10 N Exterior Concrete Block - Int Insul Main 4 10 6 8 0 84.0 ft2 0 0 0.75' 0 11 W Exterior Frame - Wood Main 11 37 8 296.0 ft2 0.23 0.75 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 W Wood Main Wood 0.460000 3 0 6 8 20 ft2 2 W Wood Main Metal 0.460000 3 0 6 8 20 ft WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (tinted) Yes 0.56 0.5 14.0 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 2 E 2 Metal Single (Tinted) Yes 0.56 0.5 23.2 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 3 E 3 Metal Single (Tinted) Yes 0.56 0.5 32.4 ft2 8 ft 0 in 0 ft 9 in Drapes/blinds None 4 E 4 Metal Single (Tinted) Yes 0.56 0.5 32.4 ft2 8 ft 6 in 0 ft 9 in Drapes/blinds None 5 S 5 Metal Single (Tinted) Yes 0.56 0.5 13.7 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 6 S 6 Metal Single (Tinted) Yes 0.56 0.5 30.3 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None 7 W 7 Metal Single (Tinted) Yes 0.56 0.5 32.4 ft2 8 ft 0 in 10 ft 1 in Drapes/blinds None 8 N 10 Metal Single (Tinted) Yes 0.56 0.5 19.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None 9 N 9 Metal Single (Tinted) Yes 0.56 0.5 32.4 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280.8 ft2 191 ft2 31 ft 13 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000300 1261.4 69.249 130.23 0.2696 5.9017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts (lnvaliElectric Strip Heat None COP: 1 28 kBtu/hr 1 sys#0 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts (InvaliCentral Unit None SEER: 15.2528.6 kBtufhr 858 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 66 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS — Supply — # Location R Value Area — Return — Location Area Leakage Type Air CFM25 Handler CIF0M5 OUT QN RLF HVAC # Heat Cool (Invali Attic 6 164 ft2 Attic 41 ft2 Default Leakage Main (invalid) c (Default) No 1 TEMPERATURES Programable Thermostat: Y]] Heating Jan X Feb Mar Venting Jan [[XX]] Feb Mar Ceiling Fans: [[XX�� LxJ pr X May JApr May un [X] Jul ll�xJJ Jun [[�X]] Jul Aug Aug X� Sep [[�X]] Sep L�l Oct Nov Occtt X Nov Dec X Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 Hours 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 Cooling (WEH) AM 78 PM 78 Heating (WD) PM 68 Heating (WEH) AM 66 PM 68 78 78 78 78 78 80 78 78 78 78 78 78 78 78 78 78 78 78 78 78 68 68 68 68 68 66 66 66 66 68 68 68 68 68 68 78 78 78 78 68 68 68 78 80 78 78 78 78 78 78 68 68 68 68 68 68 80 80 78 78 78 78 78 78 68 66 68 68 68 66 80 78 78 78 66 68 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 - 0% 1- Central Unit FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10725 S OCEAN DR. LOT 323 PERMIT #: JENSEN BCH., FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually'verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant, covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting.