HomeMy WebLinkAboutEnergy Efficiency Code 3-15-13FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JOE AND ANN HAMROCK redesign
Builder Name: L & C CONST.
Street: 10725' S OCEAN DR. LOT 323
Permit Office: st. lucie co. / ft. pierce
City, State, Zip: JENSEN BCH. , FL, 34957-
Permit Number.
Owner. SAME
Jurisdiction: 661100
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (2156.6 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 1860.60 ft2
b. Frame - Wood, Exterior
R=11.0 296.00 f12
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. WA
R= ft2
10. Ceiling Types (1142.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1142.00 ft2
6. Conditioned floor area above grade (ft2) 1603
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(230.2 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 164
a. U-Factor. Sgl, U=0.56 230.24 ft2
SHGC: SHGC=0.50
�
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: N/A
a. Central Unit
28.6 SEERA5.25
SHGC:
c. U-Factor. NIA ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
28.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 4.023 ft.
Area Weighted Average SHGC: 0.500
14. Hot water systems
a. Electric
Cap: 66 gallons
8. Floor Types (1603.0 sgft.) Insulation Area
EF: 0.920
a. Raised Floor R=20.0 1603.00 ft2
b. Conservation features
b. WA R= ft2
None
c. N/A R= ft2
16. Credits
CF, WHF, Pstat
0.144 Total Proposed Modified Loads: 37.38
PASS
Glass/Floor Area:
Total Standard Reference Loads: 49.42
I hereby certify that the plans and specifications covered by
Review of the plans and
O'V THE STg1A
this calculation are in compliance with the Flo ' a Energy
Code.
specifications covered by this
calculation indicates compliance
,y = Off,
with the Florida Energy Code.
n+1rr'� .
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
„�� F a
* rr
I hereby certify that s building, as designed, is in compliance
Florida Statutes.
COb
with the Florida En gy C e.
WE'D
OWNER/AGEN, .
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Compliance requires a roof absorptance test In accordance with 405.6.2
3/11/2013 7:18 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software - Page 1 of 5
PROJECT
Title:
Building Type:
Owner.
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/EAsting:
Comment:
JOE AND ANN HAMROCK re Bedrooms: 3
User Conditioned Area: 1603
SAME Total Stories: 2
1 Worst Case: No
L & C CONST. Rotate Angle: 0
st. lucie co. / ft. pierce Cross Ventilation: No
661100 Whole House Fan: Yes
Single-family
New (From Plans)
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
10
10725 S OCEAN DR. L
st. lucie
JENSEN BCH. ,
FL, 34957-
CLIMATE
V Design Location
IECC Design Temp
TMY Site Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Piero FL ST LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1603 12824
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID. Finished Cooled Heated
1
Main
1603 12824 Yes 2
3
1 Yes
Yes Yes
FLOORS
#
Floor Type
Space R-Value
Area
Tile Wood Carpet
1 Raised Floor
Main — —
1603 ft2
20
0.5 0.5 0
ROOF
#
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt
Tested
Emift Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 1645 ft2 0 ft2 Unfinishe
0.96
Yes 0.7
No 20 12.9
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1603 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
Main 20 1142 ft2
0.11
Wood
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
R-Alaille Et
In
Et
In
Area
R--Vaille
Fraction Ahqor
Grade-OA
1
N
Exterior
Concrete Block - Int Insul
Main
4 15
5
9
7
147.7 ft2
0
0 0.75
0
2
E
Exterior
Concrete Block - Int Insul
Main
4 42
7
9
7
408.1 ft2
0
0 0.75
0
3
E
Exterior
Concrete Block - Int Insul
Main
4 31
9
8
254.0 ft2
0
0 0.75
0
4
E
Exterior
Concrete Block - Int Insul
Main
4 14
4
8
0
114.7 ft2
0
0 0.75
0
5
S
Exterior
Concrete Block - Int Insul
Main
4 27
2
9
7
260.3 ft2
0 0.75
0
6
S
Exterior
Concrete Block - Int Insul
Main
4 29
11
9
7
286.7 ft2
0
0 0.75
0
7
W
Exterior
Concrete Block - Int Insul
Main
4 11
2
9
7
107.0 ft2
0
0 0.75
0
8
W
Exterior
Concrete Block - Int Insul
Main
4 16
8
8
0
133.3 ft2
0
0 0.75
0
9
N
Exterior
Concrete Block - Int Insul
Main
4 8
1
8
0
64.7 ft2
0
0 0.75
0
10
N
Exterior
Concrete Block - Int Insul
Main
4 10
6
8
0
84.0 ft2
0
0 0.75'
0
11
W
Exterior
Frame - Wood
Main
11 37
8
296.0 ft2
0.23 0.75
0
DOORS
#
Omt
Door Type Space
Storms
U Value
Width
Height
Area
Ft In
Ft In
1
W
Wood
Main
Wood
0.460000 3
0
6 8
20 ft2
2
W
Wood
Main
Metal
0.460000 3
0
6 8
20 ft
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Single (tinted)
Yes
0.56 0.5
14.0 ft2
1 ft 0 in
10 ft 1 in
Drapes/blinds
None
2
E 2
Metal Single (Tinted)
Yes
0.56 0.5
23.2 ft2
1 ft 0 in
10 ft 1 in
Drapes/blinds
None
3
E 3
Metal Single (Tinted)
Yes
0.56 0.5
32.4 ft2
8 ft 0 in
0 ft 9 in
Drapes/blinds
None
4
E 4
Metal Single (Tinted)
Yes
0.56 0.5
32.4 ft2
8 ft 6 in
0 ft 9 in
Drapes/blinds
None
5
S 5
Metal Single (Tinted)
Yes
0.56 0.5
13.7 ft2
1 ft 0 in
10 ft 1 in
Drapes/blinds
None
6
S 6
Metal Single (Tinted)
Yes
0.56 0.5
30.3 ft2
1 ft 0 in
0 ft 9 in
Drapes/blinds
None
7
W 7
Metal Single (Tinted)
Yes
0.56 0.5
32.4 ft2
8 ft 0 in
10 ft 1 in
Drapes/blinds
None
8
N 10
Metal Single (Tinted)
Yes
0.56 0.5
19.5 ft2
1 ft 0 in
0 ft 9 in
Drapes/blinds
None
9
N 9
Metal Single (Tinted)
Yes
0.56 0.5
32.4 ft2
1 ft 0 in
0 ft 9 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
280.8 ft2 191 ft2
31 ft
13 It
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Best Guess 0.000300
1261.4 69.249
130.23
0.2696
5.9017
HEATING SYSTEM
# System Type
Subtype Efficiency
Capacity
Block
Ducts
(lnvaliElectric Strip Heat
None COP: 1
28 kBtu/hr
1
sys#0
COOLING SYSTEM
# System Type
Subtype Efficiency
Capacity
Air Flow
SHR Block
Ducts
(InvaliCentral Unit
None SEER: 15.2528.6 kBtufhr 858 cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location EF Cap Use
SetPnt
Conservation
1 Electric None
Garage 0.92 66 gal 40 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
— Supply —
# Location R Value Area
— Return —
Location Area Leakage Type
Air CFM25
Handler CIF0M5 OUT QN RLF
HVAC #
Heat Cool
(Invali Attic 6 164 ft2
Attic 41 ft2 Default Leakage
Main
(invalid) c (Default)
No 1
TEMPERATURES
Programable Thermostat: Y]]
Heating Jan X Feb Mar
Venting Jan [[XX]] Feb Mar
Ceiling Fans: [[XX��
LxJ pr X May JApr May un [X] Jul
ll�xJJ Jun [[�X]] Jul
Aug
Aug
X� Sep
[[�X]] Sep L�l
Oct Nov
Occtt X Nov
Dec
X Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
Hours
2 3 4 5 6 7
8 9
10 11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) PM 68
Heating (WEH) AM 66
PM 68
78 78 78 78 78
80 78 78 78 78
78 78 78 78 78
78 78 78 78 78
68 68 68 68 68
66 66 66 66 68
68 68 68 68 68
78
78
78
78
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
80 80
78 78
78 78
78 78
68 66
68 68
68 66
80
78
78
78
66
68
66
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None 0
0 0 0 -
0%
1- Central Unit
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 10725 S OCEAN DR. LOT 323 PERMIT #:
JENSEN BCH., FL, 34957-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually'verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant, covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.