Loading...
HomeMy WebLinkAboutProject Information. }. 9 Load Short Form Job: MA ANDANNHAMRO... wri htsoft® Date: MARCH 10 2013 Entire House By: DALE SORENSEN Project I• • For: JOE AND ANN HAMROCK, NA 10725 S OCEAN DR. LOT # 323, JENSEN BEACH FL, FL 34957 Design Information Htg Clg Infiltration Outside db (OF) 43 90 Method Simplified Inside db (OF) 68 75 Construction quality Average Design TD (OF) 25 15 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 18 61 HEATING EQUIPMENT COOLING EQUIPMENT Make Make RHEEM Trade Trade 14 AJM SERIES Model Cond 14 AJM 36 Coil RHLL HAM 3821 Efficiency 100 EFF Efficiency 16 SEER Heating input 0 Btuh Sensible cooling 26320 Btuh Heating output 25364 Btuh Latent cooling 11280 Btuh Temperature rise 20 OF Total cooling 37600 Btuh Actual air flow 1175 elm Actual air flow 1175 cfm Air flow factor 0.063 cfm/Btuh Air flow factor 0.058 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.64 .ROOM NAME Area (ftz) Htg load - (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) FAMILY 407 4752 4703 297 271 MASTER BED 156 1765 1866 110 108 MASTER CLOSET 42 95 539 6 31 MASTER BATH 67 793 1027 50 59 NORTH BEDROOM 256 4273 3904 267 225 STAIRS 140 2118 2472 132 143 SOUTH BEDROOM 174. 2533 2972 158 172 SOUTH BATH 64 1148 1524 72 88 HALL UP STAIRS 170 1190 1221 .74 70 K 10% I Mr-r%ne%r%l1■ ^I GG 4117 4OA o D IVV 1 rl DGURVIJIvI liL. JV IGr I%M V V Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th E�! w ,—;z_ -r-1- wrightsoft' Right -Suite Residertial 6.0.119 RSR41147 ACCK C:Wiy DowmerdsUnghtsoft WAC1DemoUOE AND ANN HAMROCK REDESIGN .rrp Calc = MJ8 Orientation = 107.28:37 Page 1 Entire House 1531 18793 20359 1175 1175 Other equip loads 6571 5649 Equip. @ 1.00 RSM 26008 Latent cooling 14497 TATAI t' AACAC 447r. 447C V w/ -- •vv �.vvv-r �vvvv . .... .. Solditlic values have been manual ovetwdden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -FId- wrightsoft- Right -Suite Residential 6.0.119 RSR41147 2013-Mar-11 07:28:37 / CCK C:Wy DoaimentslWrightsolt HVAC1DemoUOE AND ANN HAMROCK REDESIGN .np Calc = MJ8 Orientation = Page 2 -1- wrightsoft® Building Analysis Entire House Job: JOE AND ANN HAMRO... Date: MARCH 10 2013 By:• DALE SORENSEN For. JOE AND ANN HAMROCK, NA 10725 S OCEAN DR. LOT # 323, JENSEN BEACH FL, FL 34957 Location: Indoor: Heating Cooling Vero Beach, FL US Indoor temperature (°F) TD 68 25 75 15 Elevation: ft Design (°F) Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 18.2 61.5 Dry bulb (°F) 43 90 Infiltration: Daily range °F) - 16 ( L) Method SimplifiedWet bulb (°F� - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftx Btuh % of load Walls 6.4 8085 31.9 Glazing 18.0 4689 18.5 Doors 10.1 405 1.6 Ceilings 1.1 1684 6.6 Floors 1.2 1799 7.1 Infiltration 1.4 2131 8.4 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 6571 25.9 Adjustments 0 Total 1 1 25364 100.0 Component Btuh/ft2 Btuh % of load Walls 5.0 6323 24.3 Glazing 22.9 5966 22.9 Doors 11.6 464 1.8 Ceilings 1.9 2839 10.9 Floors 0.6 874 3.4 Infiltration 0.4 673 2.6 Ducts 0 0.0 Ventilation 3943 15.2 Internal gains 3220 12.4 Blower 1707 6.6 Adjustments 0 Total 1 1 26008 100.0 Overall U-value = 0.144 Btuh/ft22F Data entries checked. Gla , Z -Ft,- wrightsoft- Right -Suite Residential 6.0.119 RSR41147 2013Mar-11 07:26:37 ACCA C:1My DocumentslWrightsoft HVAC1DemoU0E AND ANN HAMROCK REDESIGN .rrp Cale = MJB Orientation = Page 1 r 9 ® Component Job: ARCH 10 2013 AND ANN HAMRO... wri htsoft onent Constructions M p Date: MA Entire House By: DALE SORENSEN Project I• • For. ' JOE AND ANN HAMROCK, NA 10725 S OCEAN DR. LOT # 323, JENSEN BEACH FL, FL 34957 Location: Vero Beach, FL, US Elevation: 26 ft Latitude: 280N Outdoor: Heating Cooling Dry bulb (OF) 43 90 Daily range (OF) - 16 ( L) Wet bulb (OF) - 78 Wind speed (mph) 15.0 7.5 Indoor: Heating Indoor temperature (OF) 68 Design TD (OF) 25 Relative humidity (%) 50 Moisture difference (gr/lb) 18.2 Infiltration: Method Simplified Construction quality Average Fireplaces 0 Cooling 75 15 50 61.5 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain W Bt NIMF 1"Ffi tuh BMW Btuh Btutw Btuh Walls 13AB-Oocs: Above grade open core concrete block, siding/stucco, n 157 0.258 0.0 6.45 1009 5.04 789 no board insulation, no framing a 434 0.258 0.0 6.45 2799 5.04 2189 s 450 0.258 0.0 6.45 2903 5.04 2270 w 213 0.258 0.0 6.45 1374 5.04 1074 all 1254 0.258 0.0 6.45 8085 5.04 6323 Partitions (none) Windows 1G-r2oms: Operable, metal frame, no break, reflective glass, 2 n 46 0.720 0.0 18.0 819 14.1 640 pane, storm; 50% blinds 45°, dark; 100% outdoor insect screen; 1 e 78 0.720 0.0 18.0 1404 29.5 2305 ft overhang (5 ft window ht, 10 ft sep.) w 68 0.720 0.0 18.0 1224 29.5 2009 all 192 0.720 0.0 18.0 3447 25.9 4954 1G-r2oms: Operable, metal frame, no break, reflective glass, 2 e 32 0.720 0.0 18.0 576 14.1 450 pane, stone; 50% blinds 45°, dark; 100% outdoor insect screen; 8 ft overhang (5 ft window ht, 1 ft sep.) 1G-12oms: Operable, metal frame, no break, reflective glass, 2 s 37 0.720 0.0 18.0 666 15.2 562 pane, stone; 50% blinds 45°, dark; 100% outdoor insect screen; 1 ft overhang (3 ft window ht, 10 ft sep.) Doors 1100: Metal door, polystyrene core, with storm a 20 0.210 0.0 5.25 105 6.02 120 11,10: Metal door, fiberglass core, no storm w 20 0.600 0.0 15.0 300 17.2 344 Ceilings 16C-21mi: Ceiling under vented attic, no radiant barrier, light 1531 0.044 21.0 1.10 1684 1.85 2839 metal, R-21 insulation Floors 20P-21w: Hardwood floor over open crawl/garage, R-21 blanket 1531 0.047 21.0 1.17 1799 0.57 874 insulation Al -F�F wrightsoft- Right -Suite Residential 6.0.119 RSR41147 201 3-Mar-1 107:28:37 .4CCA C:1My DocumentsWVrightsoft HVAC1Dem6V0E AND ANN HAMROCK REDESIGN .np Calc = MJ8 Orientation = Page 1 Project Summary Job: JOE AND ANN HAMRO... -F1- wrightsoft® Date: MARCH 10 2013 Entire House By: DALE SORENSEN For. JOE AND ANN HAMROCK, NA 10725 S OCEAN DR. LOT # 323, JENSEN BEACH FL, FL 34957 Notes: Design Information Weather: Vero Beach, FL, US Winter Design Conditions Outside db 43 OF Inside db 68 OF Design TD 25 OF Heating Summary Ducts 18790 Btuh Central vent (239 cfm) 6571 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 25364 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 He ln Co 1534 Area (ftz) 1539 Volume (ft3) 12248 12248 Air changesihour 0.38 0.20 Equiv. AVF (cfm) 78 41 Heating Equipment Summary Make Trade Model Efficiency/ Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 0 Btuh 25364 Btuh 1175cf n 0.063 cfm/Btuh 0.00 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 20350 Btuh Central vent (239 cfm) 3943 Btuh Blower 1707 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Equipment sensible load 26008 Btuh Latent Cooling Equipment Load Sizing Structure 4505 Btuh Central vent (239 cfm) 9991 Btuh Equipment latent load 14497 Btuh Equipment total load 40505 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make RHEEM Trade 14 AJM SERIES Cond 14 AJM 36 Coil RHLL HAM 3821 Efficiency 16 SEER Sensible cooling 26320 Btuh Latent cooling 11280 Btuh Total cooling 37600 Btuh Actual air flow 1175 cfm Air flow factor 0.058 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.64 Boldrdalic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +}3- wrightsoft- Rig"uite Residential 6.0.119 RSR41147 2013-Mar-1 107:28:37 Za C:WIy D..M.WigMsoft WACOemoUOE AND ANN HAMROCK REDESIGN .rrp Cate = MJ8 Orientation = Page 1 • AED Assessment Job: JOE AND ANN HAMRO... ' -1- wrightsoft® Date: MARCH 10 2013 Entire House By: DALE SORENSEN Project Information For. JOE AND ANN HAMROCK, NA 10725 S OCEAN DR. LOT # 323, JENSEN BEACH FL, FL 34957 Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature (°F) 68 75 Elevation: 26 ft Design TD (OF) 25 15 Latitude: 28ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (grAb) 18.2 61.5 Dry bulb (OF) 43 90 Infiltration: Daily range (OF) - 16 ( L ) Wet bulb (OF) - 78 Wind speed (mph) 16.0 7.5 a Hourly Glazing Load �i Hour of Day / Hourly / Average / AED rimy Maximum hourly glazing load exceeds average by 20.0%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh . - 4j -wrightsoft- RightSuite Residential 8.0.119 RSR41147 2013•Mar--11 07:28:37 ACCA C:WIy Documems\Wrightsoft WAC1Demo\IOE AND ANN HAMROCK REDESIGN .rrp Cale = MJ8 Orientation = Page 1 AC Search Page l of 2 AC Search come 4 Modify ;j Export Are you a Manufacturer? t Sign In e click on a row to view/print AHRI certificate. certificates are not available for Obsolete AC and HP equipment. Status of'Active' means models are currently in production. 'Discontinued' means that the manufacturer has elected to stop producing, yet stock is still available. 'Obsolete' means that the manufacturer Is required to ianufacturing due to a test failure in the AHRI Certification Programs. Outdoor Unit I Indoor Unit I Cooling Est. National Eligible AHRI Certified Model Manufacturer Trade/Brand Manufacturer Model Manufacturer Model Furnace Capacity EER SEER Phase AHRI HSVTC Exclusively Avg, Annual for FederalTax Ref # Status Type Name (Mix -Match) Model (Btuh) Type for Export Operating Tax Cooling Credit Cost ($) 3805983 Active Systems RHEEM 14AJM SERIES RHEEM MANUFACTURING COMPANY 14AJM36 _ RHLL- HM3821+RCSL -H•3821 37600 13.00 �J 16.00I 1 . __. RCU A- CB� j II _____�._..... 278 Yes _ Now displaying records 1 -1 of 1 total Home I Contact Us (Terms and Conditions I License AHRI Directory Data Copyright ® 2012 Alr-Conditioning, Heating, and Refrigeration Institute. All rights reserved. AC Search 3/11/2013