HomeMy WebLinkAbout3-markow gen 3 wall connector specsT PRODUCT OVERVIEW
This manual applies to Wall Connectors identified by part number 1457768-**-*
Product Specifications
Voltage and Wiring
Nominal 200-240 V AC single-phase
Current Output Range
12 - 48 amps
Terminal Blocks
12-4 AWG (3.5 - 25 mm2), copper only
Supported Conduit Sizing
1�4" (21 mm) default, 1" (27 mm) optional
Grounding Scheme
TN/TT
Frequency
50/60 Hz
Cable Length
8.5' (2.6 m) or 18' (5.5 m)
Wall Connector Dimensions
Height: 13.6" (345 mm)
Wire Box Bracket Dimensions
Width: 6.1" (155 mm)
Depth: 4.3" (110 mm)
Height: 9.8" (250 mm)
Width: 4.7" (120 mm)
Depth: 2.0" (50 mm)
Weight (including wirebox) 10 lb. (4.5 kg)
Operating Temperature -22°F to 122°F (-30°C to 50°C)
Storage Temperature -40°F to 185°F (-40°C to 85'C)
Enclosure Rating Type 3R
Ventilation Not required
Means of Disconnect External branch circuit breaker
Ground Fault Circuit Interrupter Integrated, no additional required (CCID20)
Wi-Fi 2.4 GHz, 802.11b/g/n
Agency Approvals cULus - E351001
Transportation and storage: Ensure that Wall Connector is within storage temperature when moving,
transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
4 Gen 3 Wall Connector Manual