Loading...
HomeMy WebLinkAboutadam markow load calc 2Project Name: Adam Markow Project Type: One-Family Dwelling _______________________________ Phases Ampacity: 177 A Neutral Ampacity (derated): 69 A Service Voltage: 240 V Single Phase Total Phases Load: 42542 VA Total Neutral Load: 16627 VA _______________________________ General Lighting (Table 220.12) Area: 2669 sq ft Small Appliances: 3000 VA Laundry: 1500 VA Totals: Phases: 5277 VA Neutral: 5277 VA _______________________________ Fixed Appliances (220.53) Dishwasher: 1500 VA Neutral: Yes Disposer: 1500 VA Neutral: Yes Water Heater: 4500 VA Neutral: No Tesla Wall Connector: 11520 VA Neutral: No Totals: Phases (derated): 14265 VA Neutral (derated): 2250 VA _______________________________ Dryer (220.54; Table 220.54) Dryers (Sum Total): 5000 VA Number of Dryers: 1 Totals: Phases (derated): 5000 VA Neutral (derated): 3500 VA _______________________________ Cooking Equipment (220.55; Informational Notes) Column A (Sum Total): 0 VA Number of Appliances (Column A): 0 Column B (Sum Total): 0 VA Number of Appliances (Column B): 0 Column C (Sum Total): 12000 VA Number of Appliances (Column C): 1 Totals: Phases (derated): 8000 VA Neutral (derated): 5600 VA _______________________________ Heating or A/C (220.60) Heating Unit: 10000 VA A/C Unit: 0 VA Totals: Phases: 10000 VA Neutral: 0 VA _______________________________ This E-mail was generated on 2/6/2022 using the Electrical Load Calculator by American Technical Publishers, Inc.