HomeMy WebLinkAboutadam markow load calc 2Project Name: Adam Markow
Project Type: One-Family Dwelling
_______________________________
Phases Ampacity: 177 A
Neutral Ampacity (derated): 69 A
Service Voltage: 240 V Single Phase
Total Phases Load: 42542 VA
Total Neutral Load: 16627 VA
_______________________________
General Lighting
(Table 220.12)
Area: 2669 sq ft
Small Appliances: 3000 VA
Laundry: 1500 VA
Totals:
Phases: 5277 VA
Neutral: 5277 VA
_______________________________
Fixed Appliances
(220.53)
Dishwasher: 1500 VA
Neutral: Yes
Disposer: 1500 VA
Neutral: Yes
Water Heater: 4500 VA
Neutral: No
Tesla Wall Connector: 11520 VA
Neutral: No
Totals:
Phases (derated): 14265 VA
Neutral (derated): 2250 VA
_______________________________
Dryer
(220.54; Table 220.54)
Dryers (Sum Total): 5000 VA
Number of Dryers: 1
Totals:
Phases (derated): 5000 VA
Neutral (derated): 3500 VA
_______________________________
Cooking Equipment
(220.55; Informational Notes)
Column A (Sum Total): 0 VA
Number of Appliances (Column A): 0
Column B (Sum Total): 0 VA
Number of Appliances (Column B): 0
Column C (Sum Total): 12000 VA
Number of Appliances (Column C): 1
Totals:
Phases (derated): 8000 VA
Neutral (derated): 5600 VA
_______________________________
Heating or A/C
(220.60)
Heating Unit: 10000 VA
A/C Unit: 0 VA
Totals:
Phases: 10000 VA
Neutral: 0 VA
_______________________________
This E-mail was generated on
2/6/2022 using the Electrical Load
Calculator by American Technical