Loading...
HomeMy WebLinkAboutSign & Awning 2-1-22WAV?A #5380 Ft. Pierce, FL 5" Deep Front Lit LED Illuminated Letters & Logo (on 4"x 7" Extruded Raceway) - Ri Color Reference Side 3M 3635-210 .187"#2793 Red Flat Akzo nobel White Red Jewelite Aft. Face of Logo Bronze Day/ Acrylic Faces For Letters Raceway NW7 <1* White Night Red Jewelite <> JAN 2G22 *tr { Nai ?y, � nt PtifM1, Celebrating 52 Years of Quality Manufacturing and Service y t •' f t I I 0'-5" /4" 1 0'-7" 1 EDGE OF CANOP SCALE: 1 " = 1'-0" SQ FT: 9.02' Oli1Qt�`� �►G�1{1`J MIN. SETBACK REQ. FRONT SIDES CNR SIDES Self -Contained Flush Mount Canopy Sign (Side Vi Scale:3/4"= 1'-0" SIGN & AWNING CO INC 4590 118TH Avenue North Clearwater, Florida 33762 www.thomassign.com WAWA # S380 Design Number: 78767 Installation Address: 121 S. Kings Highway Ft. Pierce, FL 34945 Project Identity Number: 85144 M. ITMMIM r TSA I BB MBV 104.01.19 Project Updates X Underwriters �L Laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 4B THIS ARTICLE IS INTENDED TO BE INSTALLED W ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE BUD OF THE NATIONAL ELECTRICAL CODE ANDIOR GRIER APPLICABLE LOCAL CODES. THIS INCLUDESPROPERGROUNDINGANDBONDINGOFTHESIGN. TM 3MTM MUSTM Warranty .. . ❑ Approved DATE: ❑ Approved as noted DATE: ❑ Revise & Re -Submit DATE: The designs, concepts, drawings and specifications provided are the exclusive property ofThomas Sign & Awning Company and may not be reproduced in any way, shape or fashion without the express written permission ofThomas Sign & Awninq Company VVAWA Various RIGHT SIDE INSTALLATION 7/8"DIA. ELECTRICAL PENETRATION (IN BEAM ONLY) 1-1/2" DIA. ELECTRICAL PENETRATION (IN 24G METAL ONLY) 6-9 1/4" 4'-5 114" b'-4 1/2'1 V-11 1/4" rr--�-- r�------------------------------------------------------- E5 J- �- - BOXED SQFT. = 9.02' 5" Deep LED Illuminated Letters & Logo (on 4"X 7"Extruded NOTES: RIGHT SIDE INSTALLATION • FLAT HEAD SCREWS TO BE USED • DISCONNECT SWITCH, THE MANUFACTURING AND U.L LABELS SHOULD BE PLACED ON LEFT SIDE OF RACEWAY LED 0 WALL FASTENER LOCATION, TYPICAL - RIGHT SIDE Load: 30.0% Modules: 25 Watts: 18.0 of 60.0 PS: HanleyLED 60w W A W A GOOSE 9 mods 5 mods 6 mods 5 mods 20 mods 6.5w 3.6w 4.3w 3.6w 6.0w 6.7 mod/ft2 7.4 mod/ft2 6.3 mod/ft2 7.4 mod/ftz 21.6 mod/ft2 1.341 sq ft 0.673 sq ft 0.951 sq ft 0.673 sq ft 0.925 sq ft 25 Modules:.Hanleyf LED.-. Peregrine P3072 RedHLED-P3072R 20 Modtiles:.Haliley LED `-''Phoenix PF-2030 Mirii HLED PF203'6 45 Total Modules , ;24 0 Watts 2 Power Supplies Hanley ;LED HanleyLED 60w° 4'S61 q ft ,:,36 152 verimeteffloet _ ut Load: 10.0% Modules: 20 Watts: 6.0 of 60.0 PS: HanleyLED 60w io Celebrating 51 Years of Quality Manufacturing and Service ^ 9 PAINT COLORS 5 ELECTRICAL NOTES V1 VINYL COLORS 5 FABRICATION NOTES 1 I 1 I I I V-2 3/4" 0'-17" Scale: 1"=1'-0" SQFT: 9.02' D esign Loads PER FL BLDG CODE, 7TH ED (2020) BASIC WIND SPEED, V 160 MPH RISK CATEGORY II EXPOSURE CATEGORY C DESIGN WIND PRESSURE 220 PSF FL CERTIFICATE OF AUTHORIZATION NO 31751 .4 No 80640 _ Color Reference Red Jewelite 3M 3635-210 Face of Logo Bronze Day/ White Night .187"#2793 Red Flat Acrylic Faces For Letters Akzo nobel White Raceway Paint to Match 876-C Copper Metallic Gloss Returns STATE OF ' REVIEWED FOR CODE COMPLIANCE ST. UCIE COUNJY BOC 701 SECTION DETAILS / INSTALLATION INSTRUCTIONS 1. EXISTING CANOPY 2. ACRYLIC FACES 3. 1"JEWELITE TRIM CAP 4. ALUMINUM BACKS 5. ALUMINUM RETURNS PAINTED 6. WALL FASTENERS, QTY 18, #8-1 a SELF -DRILLING SHEET METAL SCREWS 7. LED LIGHTS 8. LED POWER SUPPLY 9. EXTRUDED ALUMINUM RACEWAY 10. 120V LISTED DISCONNECT SWITCH 11. 1/2"MIN CONDUIT, WEATHERPROOF PASS THROUGH) 12. DRAIN HOLES WITH LIGHT COVERS IF OUTDOORS 13. SCREW ATTACHMENT OF FACES 14. BRANCH CIRCUIT (WIRING HOTTO HOT, NEUTRALTO NEUTRAL, GROUND/ BOND TO GROUND) 15. UL RATED WIRENUTS 16. WEATHERPROOF DISCONNECT SWITCH 18. SAFETY CHAIN IN RACEWAYTO PREVENT COVER FROM FALLING 19. PRIMARY ELECTRICAL NTS TOTAL SQFT = 9.02' PART # WAWACL16RWBCKR ESTIMATE # 156036 BACKS..040'PRE FINISHED ALUMINUM RETURNS: ,050"PRE FINISHED ALUMINUM DEPTH: 5' FACBS:.187'42793 RED ACRYLIC -FLAT TRIM CAP:1'JEWELITE LE.Da HANLEY LED -PEREGRINE P3072-RED FASTENERS: AS REQUIRED Colors for LED Letters FACES:02793 RED ACRYLIC RETURNS INT:WHITE PRE FINISHED RETURNS EXT: PAINT TO MATCH PMS 1876C METALLIC COPPER GLOSS TRIM CAP REDJEWELITETNMCAP L.E.D.: RED Material for LED CL ,,, BACKS: .M0' PRE FINISHED ALUMINUM RETURNS:.OSO°PRE FINISHED ALUMINUM DEPTH: S' FACES:.177° #2447 WHITE ACRYLIC -FLAT TRIM CAP:T°JEWELTrE L.E.D.: HANLEY LED- PHOENIX PF-2030 MINI -WHITE FASTENERS:ASREQUIRED Colors for LED CL ... FACES -WHITE RETURNS INT: WHITE PRE FINISHED RETURNS EXr.PAINTTO MATCH PUS 4976C METALLIC COPPER GLOSS TRIM CAN WHITE JEWELITETRIMCAP LE.D.' WHITE 1) 4"X7"EXTRUDED ALUMINUM RACEWAY 2) SAFETY CHAIN IN RACEWAYTO PREVENT COVER FROM FALLING 1) AKZO NOBELTO MATCH PMS #876C COPPER METALLIC GLOSS 2) AKZO NOBEL WHITE SATIN FIMSH 1) 3M 3635.21 OPERF VINYL DIGITALLY PRIMED BRONZE POWER SUPPLIES QTY. I - UL APPROVED DISCONNECT SWITCH 6'MIN ELECTRIAL WHIPANEATHERPROOF C01 SIGN IS WIRED AS IS ON SCHEMATICFOR POW ELECTRICAL SPECIFICATIONS LED MODULES=45 HOVOLT INPUT HANLEY TRANSFORMER SECONDARY VOLTS WATTS AMP, INPUT 2 1 H60WPPS277 12 1 60 0.9 TOTAL 1.8 1 20 AMP420 VOLT CIRCUIT REQUIRED 1 SIGN & AWNING CO INC 4590118TH Avenue North Clearwater, Florida 33762 800-526-3325 www.thomassign.com Wawa - CL & CANOPY CL RW MASTERS Design Number: 89069 Installation Address: Various Project Identity Number: 84035 TSAr-- -- J`Z,__..__.___ MBV03.03.21 Project Updates: FILE COPY OUnderwriters �L Laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 101:S 3MTM MCSTM Warranty ❑ Approved DATE: ❑ Approved as noted DATE: ❑ Revise & Re -Submit 1 I 1 Of 1 SCALE: 3/4" = 1'-0" fly ON - OMI � OMI OW � MU � OIN � L1N fir G11U DW - 0.1 - ON � ON - t141 � ON -'�- ON �- (Nl � pry - Cerl GNU ONU - CNI - ONIF CNU - ON - OMF - ONU 01111 GNU - DN ON - dN � ON - OM � C1FF l � r � ON CMU -GIN -DN 1------------------------------_-_ ------ ----_ ---------------------------- -MLro xuw mane SO' TP FAYOY'EASOEIIT • • • AiTKr 0 IN Ex®nox W .�• II I ORANGE AVE. pv. r srDDEN1i I N4EIE ED AG - _ DVE 16 NFww lfl" 1,OP9GN 6 I PROPOSED TRACTS SSOPSIG4 IP r" PSiRPIN NT FOOT ap° f �'o• P :li hfE� ITO1EN 7v.oG1 1 *. [7—nu -m —5 pD 0.09 AC�APPRO%U41TE vFTFa.Fur4RNec• DpEGrN N •'l -35' r'f& VALVE a0S5W OROSSWJUX PERFOOT 1TIUPpGMFDOE =M711-001 INDE;'l114 �1Y .Y, �' •T. 12'SNARED USE PATH fASPNAITr _ "'roumamW a, L4 �wPRDnuA¢ �� y R '3� `� e $ pmmraEEsaaw 6 4fi 1 . t a v: "' _� W s t. - 5 7 :tl ',y aottwAl7? ,: PARCEL ID: '� +"• r n t' d ze t "� +: Y siWPrleeStwor 2311-417-0002-000-7 g . �t+ OPS' < v , �� may, "fi t r 4 vl .`e- .'^a 5T •h iiRDPDeAiED a �'� wDEll7»•ws S. w' O.R.B. f043. PG. 1780 } PSIGN"' ^'- r' TRACT? ZONING: CG LAND USE: M)KD a 'DEIEGFAEUWApNG' 6 IN •somwDusuamc �' I .0 .1 33.5' lh F7777nAI mi LEGEND ASPHALT PAVEMENT ••. 4' CONCRETE SIDEWALK ' 6• STANDARD CONCRETE NO m: UNLESS OTHERWISE NOTEDTHE CONTRACTOR ISRESPONSIBLE FOR TEMPORARY DE•WATERING B' HEAVY DUTY CONCRETE SCALE:10=301 OF STRUCTURES, SEWER LINE, DRAINAGE PIPE 0 15® . AND WATER LINES a NG PER FOOT DE117U3 911E 18y R IROPOSEO XAF101W 1, La SIPPING 0 AYAIL RISE s7PoHNGPERFDOT 1-101711d01 TDAET 7 PpG Da FOOT-. I I 1xDEEni�1 I I I I I I I I i6' WIDE ACCE55_.1 2SO OLD q•/M ME 1 I I I I 6•R6• VENT STACK I 1-E SfOP I I I I ol� I g �45L3'AIR MACHINE I p o1 I c 41.75' �M I N STOD IVUI& II s7Dv slwN ,� I F I I YUIL WFSLP.4 FPALLV[V/pgIRW&UNLOFTaU LGWiSFRGN¢•W LLC uPN•EiGa: WAWA at KINGSGATE CENTER LOCATED LOCATED IN ST. LUCIE COUNTY, FLORIDA 1 10BN0_520017-026 Horizontal Control, Striping and Signage Plan 04 OF 24 0 Ir n0m �/� n` m ®3m Z W Z ;0 O0 0 FILE COPY ';r,zo t 6 r- THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL Description: Raceway -Mounted Canopy Wall Sign Engineering Calculations Table of Contents Structural Engineering Calculations Prepared by: John F. Dougherty, P.E. Florida P.E. No. 80640 Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Code: Florida Building Code, 7th Edition (2020) - Building Pages 1- 3 \\\\\\1I I I / /////// \�`\ &®®uGN�; No 80640 'W� THOMAS Sign & Awning Company, Inc. 4590 118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No 80640 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL Sign attached to eave of open building Building eave height or mean roof height, h = 20.6 feet above grade (h<= 60') Installation height, z = 20.3 feet above grade Roof Shape: Monoslope Florida Building Code 7th Edition (2020) Building ASCE 7-16, "Minimum Design Loads and Associated Criteria for Buildings and Other Structures" ASCE 7-16 Chapter 30, Section 30.7 for Open Buildings (Enclosed, low-rise buildings) ASCE 7-16, Table 1.5-1(p. 4); Risk Category II ASCE 7-16, Figure 26.5-1, Basic Wind Speed, V = 157 mph (interpolated) Use Basic Wind Speed, V = 160 mph ASCE 7-16, Section 26.7; Surface Roughness C Grassy fields Exposure Category C ASCE 7, Section 26.11, G = ASCE 7, Table 26.10-1, Kh= ASCE 7-16, Section 26.8, Topographic Factor, Kzt ASCE 7, Section 26.7.3, qh = 0.00256 Kzt Kh VZ= ASCD 7, Fig. 30.7-1 for monoslope roof Roof plan dimensions: Eave Heights; High Roof Angle, 9 = 10% of least roof plan dimension= 0.4h = dimension a= Overall Size of sign Height Width Effective Wind Area ASCE 7, Fig. 30.7-1 CN = ASCE 7, eq 30.7-1, p= qh G CN = 0.85 0.94 1.00 61.6 psf 55.0 ft X 198 ft 25.2 ft; Low 16.00 ft 9.46 degrees 5.50 ft 8.23 ft 5.50 ft 1.67 feet 6.77 feet 11.31 sgft<a"2 3.60 Zone 3 -4.20 188.5 psf -219.9 psf Use p=! 219_9) psf 1 of 3 9/29/21 Sign or Channel Letter Sizes Sign Height 1.67 feet Width 6.77 feet Area 11.31 sq ft Thickness 0.75 feet Max Dimension 6.77 feet Lateral Area 5.08 sq ft Wind Force Normal to Sign Face Face Area (sq ft) 11.31 Pnet (psf) 219.9 Design force (lb) 2486.8 No of anchors 18 Force per anchor 138.2 lb tension comprised Tension in bolts is 100% of wind load Wind Force Applied to Side of Sign / Letter LateralArea (sq ft) 5.08 Pnet (psf) 219.9 Design force (lb) 1116.8 No of anchors 18 Ib wind Fws per anchor 62.05 shear Self Weight of Sign / Letter r Assumed unit weight of sign 5 psf Sign area 11.31 sq ft Weight of sign, say 56.5 Ibs No of anchors 18 Fg per anchor (lb) 3.14 gravity shear Shear force lb total = Fws+ Fg = 62.12 shear Shear is 5% dead load and 100% wind load For load combination 1.0 DL+0.6 Wind: 82.9 • 1 lb tension 40.4 j lb shear 2 of 3 9/29/21 To be shown on construction documents: BASIC WIND SPEED, V: 160 mph RISK CATEGORY: 11 EXPOSURE CATEGORY: C DESIGN WIND PRESSURE, Pnet: ___ 220 psfu Refer to International Code Council - Evaluation Report ESR-2196 "Hilti Self -Drilling and Self -Piercing Screws" Check #8-18 screws back of cabinet are 0.063" thick assume face of canopy fagade > 0.063" thick Table 2, Allowable Tensile Pull -Out Load = 125 lb Table 3, Allowable Tensile Pull -Over Load >= 170 lb Minimum allowable tension = 125 lb Table 4, Allowable shear (bearing) = 373 lb Stress ratio = 82.9 / 125 + 40.4 / 373 = 0.77 <=1.00; OK 3 of 3 9/29/21