Loading...
HomeMy WebLinkAboutSTRUCTURAL ENGINEERING CALCULATIONSWAWA #5380 Ft. Pierce,*L FSCI'CL v w J,AN 1 2' 202z FILE CuPY St, Lucie county 1z7 Permitting ,, Celebrating 52 Years of Quality Manufacturing and Service Color Reference REVIEWED EC�� BODE C®MPLIANK-' Sit. LUCIE COUNTY FILE COPY 7` �� �1 yL ?- vy 67 rito] 1y1FIV SIGN & AWNING CO INC 4590 118TH Avenue North Clearwater, Florida 33762 www.thomassign.com WAWA # 5380 Design Number: 78767 Installation Address: 121 S. Kings Highway Ft. Pierce, FL 34945 Project Identity Number: 85144 TSA BB MBy 110.25.21 Project Updates: 11.09.21 MBV- Addedlandscaping OUnderwriters �L laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 MIS ARTICLE IS wTENDED M BE DISTALLED IN ACCORDANCE Wml THE REOUIRENENTS OF ARTICLE IM OF THE NATIONAL ELELTRIGL LODE ANDIOR OTHER APPLICABLE LOCAL CODES. THIS NLLUDES PROPER GROUNDINGAND BONDING OFMIE SIGN. TM 3MTM MCSTM Warranty ❑ Approved DATE: ❑ Approved as noted DATE: ❑ Revise & Re -Submit DATE: The designs, concepts, drawings and specifications provided are the eulusiw: property ofThomas Sign & Awning Company and may not be reproduced in any way, shape or fashion without the express written permission of Thomas Sign & Awning Company WAWA #5380 Ft. Pierce, FL 15'-0" STREET SIDE 8'-6" 8'-4" 8'-2" 8'-0" L.7 1 1 /4d 2'-6' --I Dia. Custom DIN Monument Dis SWITCH 15' OAH - C 2"x 2" x 3/16' Alum. angle framing bolted to Steel An le x' dia. Main Steel Support Saddle 2'x 2"x 3/16' Steel Angle welded to pipe SADDLE DETAIL -SCALE: NTS M BUIL13ING SIDE 2'-6„ L2'-2„ 2'-O" 1'-10"-TII DECORATIVE CAP DETAIL I NTS (T'" ' DECORATIVE CAP DETAIL I NTS �2 0'-2" 1 L - 1 1 *--GRADE 2'-8" 3,-4„ 3'-8" 8" Dia Standard Weight Steel Pipe (8.63"0.13, 0.322"Wall), ASTM A500 Grade C �-- 2'-6" --I Drilled Pier, D'Ia. Unrelnforced 3,000 psi Concrete SCALE:1/4"= l'-O" NEMA BOX PRIMARY (QTY:2) NEMA BOX SECONDARY (QTY:1) ELECTRICAL CONSIDERATIONS: SEPARATE DEDICATED ELECTRICAL CIRCUIT(S) FOR EMC DISPLAYS QTY.2 - 60-12OV-108264-DE LED PS 2.OA QTY.6 - SELF-CONTAINED GAS PRICE UNITS 5.46A TOTAL AMPS: 7.46A Celebrating 51 Years of Quality Manufacturing and Service 5 PAINT COLORS 5 ELECTRICAL NOTES V1 VINYL COLORS 5 FABRICATION NOTES 7,_7„ F7 P3 ® FCO Detail \�oxII 111//����/ \\\� �C.p000AF No 80640 j � `. STATE OF Scale: 1/2"=V-0" SECTION DETAIL I INSTALLATION INSTRUCTIONS .A /A11 rrrrrrrrrr,°r'rri/irigirr,rrrirria rir„rrrr rrrrrrrrrriirrriii,,,,rr�i Adhesive NOTE: Threaded studs with 1" minimum embedment and install with NTS HILTI HIT-HY 10 PLUS ANCHOR ADHESIVE TYPICAL SIGN' FRAME i 2 1. 2x2"3/16 Aluminum 2. Fillet welded joints 3.3M Scotch -Weld 4. Aluminum Faces 3 4 I MASONRY BASE DETAILS (BY OTHERS) I 1. #4 BAR, EMBEDDED 4' INTO SLAB IN HOLE FILLED WITH HILTI 10 PLUS ADHESIVE 2. MASONRY BLOCK BASE WIT STONE VENEER 3. G' THICK CONCRETE SLAB 10'- 0" 1 r i 1. =1W Z2v 1 - Q�&7 TOTAL SQFT = 100 PART # X ESTIMATE # X Material for Free Standing Sign EXT. FILLER•.080"ALUMINUM SHEETING FRAMING 2"X2"X3116"ALUM.ANGLE FACES: .125"ALUMINUM SHEETING CAB. TOPIBOTTOM• .063"ALUMINUM SHEETING STONE SILL' BY OTHERS POLE COVER%080"ALUMINUM SHEETING SUPPORTS' DIRECT•BLIRIED STEEL PIPE Colors 1 FILLER: TO MATCH EMS 07401 -SATIN CAB. TOPiBoTTOM'JO MATCH WHITE -SATIN POLE COVER -TO MATCH PINS 47A01- SATIN STONE SILL' NIA FACE BKGND' TO MATCH PMS 47401-SATIN Fabrication .• 1) LED ILLUMINATED CHANNEL LETTERS(FACE LIT) -SEE PIS F 2) LED ILLUMINATED LOGO (REVERSE LIT) -SEE PG 20 3) FUELITE 3000 SERIES GAS PRICE DISPLAYS #SEE PIS30 4) FULL SIDEACCESSPANELS SECUREDWRH98X3/4' FLUSH HEAD FASTENERS 5)1'IRNYLBORDER 6) 2"UNISTRUT 1) 3M #7725-13 TOMATO RED, I ST SURFACE 2) 3M #7725-46 KELLY GREEN,1 ST SURFACE 3) 3M#7725.57OLYMPICBLUE, ISTSURFACE 4) 3M#7725-10WHITE PaintNotes 1) AKZO-NOBELTO MATCH PMS7401 SATIN 2) AKZO-NOBEL WHITE SATIN 1) ULAPPROVED DISCONNECT SWITCH IN4"X4"NEMA BOX, I) SEPARATE DEDICATED ELECTRICAL CIRCUIT FOR EMC DISPLAYS 3) NEMA BOX I SURGE CARD ENCLOSURE (SEEPAGE 4 FOR DETAIL) 4) 16'MINWHIP /ELECTRICAL PRIMARY FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC SIGN & AWNING CO INC 4590118TH Avenue North Clearwater, Florida 33762 www.thomassign.com WAWA # 5380 Design Number: 78767 Installation Address: Orange Ave & lGngs Hwy Ft. Pierce, FL Project Identity Number. 85144 TSA BB MBV 08.27.21 Project Updates: X OUnderwriters �L Laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 THIS ARTICLE IS INTENDED TO BE INSTALLm IN ACCOROAHCB WRH THE REOLERETgMS OF AROSE BOB OF THE HAIIONAL ELECTRICAL CODE ANDIOR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPERGROUNDNGANO BOIGMOOFTHESIGN TM 3MTM MCSTM Warranty ❑ Approved DATE: _.-.-_._.._ ❑ Approved as noted ❑ Revise & Re -Submit ��� �� DATE: The designs, Concepts, drawings and specifications provided are the exclusive WAWA #5380 Ft. Pierce, FL 3'-3" 2'-2" Channel Letter Detail Load:14.5% Modules: 29 Watts: 8.7 of 60.0 PS: HanleyLED 60w 7'-2 5/8" -- 2'-1 1/4" --� ANCHOR LOCATIONS Load: 53.3% Modules: 40 Watts: 32.0 of 60.0 PS: HanleyLED 60w Typ. W A GOOSE W A 13 mods 9 mods 29 mods 9 mods 9 mods 10.4 w 7.2 w 8.7 w 7.2 w 7.2 w 3.7 mod/ft2 5.1 mod/ft' 26.1 mod/ft' 3.6 mod/ft' 5.1 mod/W 3.537 sq ft 1.775 sq ft 1.113 sq ft 2.508 sq ft 1.775 sq ft 29,`Modules Hanley LED Phoenix PF-2030 Mini - HLEI) PF2030 .i 40:Modules'HE i LED PhoeriiwPF 2080,Red HLED PF2080R<; 69 Total Modules,, 40:7 Watts 2 Power-Suppit". Hanley LED -HanleyLED 60w I0.709 sq ft, 54.133.4 penmeter/feet, LED Layout Scale: 3/4"=1'4' TO. 3-1/4' 2'-5- 3-1/4" 2,,5" 3-1/4" 2,-5" Celebrating 51 Years of Quality Manufacturing and Service H PAINT COLORS 5 ELECTRICAL NOTES 2VINYL COLORS 5 FABRICATION NOTES \\��� �'Q� �j �G E N 8 2-3/8" H 00 No 80640 * _ Vinyl Detail ' STATE OF 411 SCALE: 3/4" = 1'-0" BILE COPY .. PER FL BLDG CODE, 7TH ED (2020) BASIC WIND SPEED, V 160 MPH RISK CATEGORY II EXPOSURE CATEGORY C DESIGN WIND PRESSURE 62.1 PSF FL CERTIFICATE OFAUTHORIZATION NO 31751 REVIEWED FOR Ir NTS CODE COI""PLIA ACE ST. LUCIE COUNTY SOCC TOTAL SOFT = 100 PART # X ESTIMATE # X IMMUhN5:.048•ALUMINUM DEPTH: S' FACES: .187'#2783 RED ACRYUC-FLAT TRIM CAP: 1"RED JEWELNETRIMCAP LE.Da HANLEY LED -PHOENIX PF 2080 RED ROWS: t FACES; #279 RETURNS INr: RETURNS EXT: TRIM CAP: R LE.D,: RED RETURrM .063"ALUMINUM DEPTH: 4" FACES: .12S"ALUMINUM STAND-OFFS: 1112" STAINLESS STEEL LE.D-' HANLEYLED -PHOENIX PF-2030 MINI ROWS: I FACES: RETURNSEXT: TO MATCH PMS #874C BRONZE -SATIN STAND-OFFS: NONE LE,D,: WHITE PaintNotes 1) AKZO-NOBEL TO MATCH PMS PMS 874C BRONZE SATIN FINISH VinylNotes 1) 3M #7725-13 TOMATO RED, I ST SURFACE 2) 3M #7725-46 KELLY GREEN, 1 ST SURFACE 3) 3M #7725-57 OLYMPIC BLUE, IST SURFACE 4) 3M#7725-IOWHITE S) 3M#3730M•UOPAQUEBRONZE Electrical Notes 1) WHITE LEDS (BOTH SIDES) 2) RED LEDS(BOTH SIDES) 3) POWER SUPPLIES - (BOTH SIDES 4 SIGN ISWIRED AS 15 ON SCHEMATIC FOR POWER SUPPLY) irml Mucm LID-3 ELECTRICAL SPECIFICATIONS LED MODULES=124 110 VOLT INPUT HANLEY SECONDARY AMP, TRANSFORMER VOLTS WATTS INPUT 2 H60W-PP52771 12 1 60 110.9 TOTAL 1,8 (1) 20 AMP-120 VOLT CIRCUIT REQUIRED -SIGN (1) 20 AMP-120 VOLT CIRCUIT REQUIRED - PRICERS r� e • rmg SIGN & AWNING COINC 4590 118TH Avenue Nwth Clearwater, Florida 800-526-3325, www.thomassign=m WAWA # 5380 Design Number: 78167 Installation Address: Orange Ave & lCings Hwy Ft. Pierce, FL Project Identity Number. 85144 TSA 86 MBV 08.27.21 Project Updates: m..�., X OUnderwriters �L Laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 THIS ARTICLE IS INTENDED TO BE INATALLBO IN ACCORDIME wnH THE REWiREMERM OF ARTICLE US OP THE RAT MAL ELECTRICAL CODE ANDIOR OTHER AP0.1CMLS LOCA C0 & TMSINCLUDESPROPERGROUNDMOAND MINNOW IMSION: TM 3MTM MCSTM Warranty Aee . ❑ Approved DATE:__ ❑ Approved as noted DATE: ❑ Revise & Re -Submit are the exc,mive R & Awning Company Iced In ary way, shape xprelswr en PermbslDn 2 2of4 WAWA #5380 Ft. Pierce, FL 49.00 .X,; •—i ?.00 ... ... �_.' O ... LIGHT SENSOR-----' FRONT VIEW FACE DOOR LATCH 46.50 [11711— � BOTTOM VIEW 5.00 [1271 0.88 [221 KNOCKOUT @4 FOR 1/2" CONDUIT FITTING 01.11 [28] KNOCKOUT @2 FOR 3/4" CONDUIT FITTING 4.50 [114] REAR VIEW 7.00 [1781 THIS IS A SINGLE FACED DROP -IN DISPLAY TO BE MOUNTED IN A RECTANGULAR OPENING IN A LARGER SIGN. DIMENSIONS ARE IN INCHES [MILLIMETERS]. USE HOLES IN THE FRONT FLANGES OF THE CABINET TO ATTACH THE DISPLAY TO THE SIGN FACE USING (QTY 8) #10 STAIN- LESS STEEL SELF -TAPPING SHEET METAL SCREWS. THE OVERALL SIGN STRUCTURE MUST BE DESIGNED WITH SUFFICIENT VENTILATION SO THATAIR AROUND THE DISPLAY DOES NOT EXCEED 120-F [49-q. THE DISPLAY IS FRONT VENTILATED. NO PORTION OF THE FACE MAY BE COVERED. SIGNAL INTERCONNECT CABLES ARE PROVIDED AND MUST BE ROUTED AND CONNECTED WHEN MULTIPLE DISPLAYS ARE INSTALLED WITHIN A SINGLE SIGN. THIS DISPLAY IS A UL RECOGNIZED COMPONENT. Daktronics Fuelight Gas Pricing D Celebrating 51 Years -of Quality Manufacturing and Service 2.50 [64] P LON SIGN DISPLAYTO INCLUDE: • TY.2: FL-3000-18-11-13I GAS PRICING DISPLAYS 19.50 • TY.2:FL-3000-18-G-DI GAS PRICING DISPLAYS [4851 TY. 2: FL-3000-18-W-DI GAS PRICING DISPLAYS • �► L DIMENSIONS AND SPECIFICATIONS FOR INSTALLATION AND E ECTRICAL REQUIREMENTS MUST BE CONSIDERED AND ++SIDE VIEW HEREDTO. MOUNTING HOLES + � I � I � i I + � I + � I 4.00 [102] j I I �— 3.50 [891 3.50 [891 0 0 4.50 [14] 7. [00 178] AS REQUIRED I � ALUM. FACE i i II i 46.50 [1181] 7 19.50 RECOMMENDED [4951 SIGN FACE OPENING L SCALE: NTS ��\` DOUG � ..� No 80640 , r t*, STATE OF i i0N � II Color) Capability: One color (red, amber or green) Viewing Angle: 140 degrees horizontal x 70 degrees vertical Contrast Enhancement: LEDs protrude through a punched black metal face Digit Design: 7-segment bar Service Access: Front access Control: Fuelink or alternate TOTAL SQFT = 100 PART # X ESTIMATE # X Power. 120 VAC single phase; 240 VAC single phase Display Dimming: 16 levels (automatic or manual control) Communication Options: Direct connect, Modem, Radio, Point of Sale (POS) interface Compliance Information: UL Recognized, cUL Recognized Reliability Features: IP-67 rating on digits, drivers, power supplies and cable connections Digit Font Options: Programmable digit segments Single -face Max. Max. Max. Single -face Cabinet Single -face Cabinet Weight Wafts Watts Watts Digit Feet -inches Meters Pounds per Face per Face per Face Height (H x W x D) (H x W x D) (kg) RED AMBER GREEN 1811 1110" x 411"x 3" 0.56 x 1.25 x 0.07 Dimensions Digit Model number size A B FL-3000-18-DI 18" 1-7.5" 3-10.5" REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC 30 (14) 70 70 70 3000 Series Drop -in digit FILE COPY SIGN & AWNING CO INC 4590118TH Avenue North Clearwater, Florida 33762 800-526-3325 www.thomassi,,gn.com WAWA # 5380 Design Number: 78767 Installation Address: Orange Ave & Kings Hwy Ft. Pierce, FL Project Identity Number: 85144 TSB 8 M8v y 08.27.21 Project Updates: OUnderwriters �L Laboratories, Inc: LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 THIS ARDCLE IS INTENDED TO BE NSTUIED IN ACCORDANCE WITH THE REGUIRDWITS OF ARSI E 600 OF THE NATIONAL ElECTRIM CODE ANDIOR OTHERAPRICAHE LOLL CODES. TNISINCLUDESPRCPERGROUNONGANDM GOFTHESO1L TM 3MTM MCSTM Warranty ❑ Approved _DATE: ❑ Approved as noted DATE: ❑ Revise & Re -Submit The design,, concept; dravdngs and speclfl."..s provided are the ettlus ve 3 3of4 WAWA #5380 Ft. Pierce,-F-L——— I 01-11/ ' ; 0'-11/2" I 0'-4" — — -i , ; 0'-4" I I I I I I j I I I I I 1 — I I I ------- I • — --1 -------I I I I ? I ' I I I I •� I L— — — — — — ' -- ,-- I ------� ------- --,----------------- 1 I •� I I ' I I I I II I I I I .LI I I , go I �• 1 I I ilk, I j?--....... 01 -------- �' I ....•••••• .......•••.... a, 0 I I I t I I , I , I I I , I I ----------------------------1 •— _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I I 1 I I , I , I , I , I 4 5 I 2 i I I 7 j �• i ...................... .............. t I 13 I I I I � I I I I I 1 J 1 ............ I ................-- 11 I I I I ; I I I I I 16 10 i I 15 17 , : I 18 I I , n - Section Detail Celebrating r__--------- _ 51 Years of Quality Manufacturing and Service IN — 1— —_—T— ________- .--- j , I 1. PYLON SIGN DISPLAY CABINET 1 2. CLEAR POLYCARBONATE BACKS I I ff -- - i-••-;----., r --- i- •- � 3. ALUMINUM FACES I I z 23 za I I f; I I 4• ALUMINUM RETURNS I I '• ; ; I I 5. TECH SCREW ATTACHMENTTO ANGLE 6. ALUMINUM ANGLE FOR ATTACHMENT,, CAN TO BACK � I, 1�' I 7. 1/4"-20THRU BOLT I 8. STAINLESS STEEL SPACER SLEEVE I 9. LED UNITS I I '•' I 10. LED POWER SUPPLY 11. 1/2"WEATHERPROOF PASS THROUGH 12. ACRYLIC FACES I ; I 13. 1"JEWELITE 14. ALUMINUM BACKS I I 15. ALUMINUM RETURNS I 16. SCREW ATTACHMENT OF FACES I___________ ___-s___I --__--_—___I 17. DRAIN HOLES W/ LIGHT COVERS IF USED OUTDOORS 11 --------- ------ -----------------I 18. 1/2 LISTED FLEX 19. BRANCH CIRCUIT (WIRING HOTTO HOT, NEUTRALTO NEUTRAL, I GROUND / BOND TO GROUND) I 20. UL RATED WIRENUTS I ►7 I I ' ' I I I 21. PRIMARY ELECTRICAL SOURCE (1/2"MIN. CONDUIT) NEC 22. FL-3000 SERIES GAS PRICING DISPLAY- RED 1 23. FL-3000 SERIES GAS PRICING DISPLAY- GREEN I i I 24• FL-3600 SERIES GAS PRICING DISPLAY- WHITE 25. SINGLE POLE SINGLE THROW 120 VOLT WEATHERPROOF I I I I DISCONNECT SWITCH RATED 20A-120/277V PER NEC 600-6 ? AND LOCATED WITHIN 50' IN SIGHT OF SIGN. I - - 1 26. NEMA BOX / SURGE CARD ENCLOSURE I 1 27.2" UNISTRUT I I I 5 1 I � I Q, :,: '• Q; 20 I I I I ' i f i I � 0 I I I I I I I I I - - - - - - - - - - - - - - - - - - - - - - - - I I I I I I - - - - - �uliirr�i IDOUGfi Oi o 80640 STATF OF 'PIP 2v1_vZ6% REVIEWED :ODE COMPLIANCE LUCIE COUNTY Ror 4590118TH Avenue North Clearwater, Florida 33762 800-526-3325 www.thomassign.com Installation Address: Orange Ave & Kings Hwy Ft. Pierce, FL Project Identity Number: 85144 TSA BB MBV -- 08.27.21 a Project Updates: OUnderwriters �L Laboratories, Inc. LISTING E89514 ELECTRIC SIGN COMPLIES TO UL 48 THIS ARTICLE IS INTEND® TO BE RLSULLED w CCOMWOE WITH THE REOUBEL®RTS OF ARRCIE WO OF THE W RONAL ELECTRICAL CODE ANUIOR OTHER APPUCAEE LO CODES. THIS INCLUDESPROPERGROUNDINGAROSCH IG OFTIESIGN. 3MTM MCSTM Warranty ❑ Approved _DATE._ ,._. ❑ Approved as noted DATE: THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL Description: 15'-0" Tall Fuel Pricer Monument Sign Engineering Calculations Table of Contents Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Structural Engineering Calculations Prepared by: John F. Dougherty, P.E. Florida P.E. No. 80640 Code: Florida Building Code, 7th Edition (2020) - Building Pages 1-11 \\��\\lI I I I ////,/ DOU Oyt� i No 80640 STATE OF 0%j � V-I J Gccp// Z- I THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL For free-standing solid signs, apply ASCE 7 provisions. ASCE 7-16 Chapter 29 Wind Loads on Building Appurtenances and Other Structures... Figure 29.3-1 Clearance ratio, s/h = Aspect ratio, B/s = Cf for Case A or B Cfc1 for Case C, 0 to s Cfc2 for Case C, s to 2s Cfc3 for Case C, 2s to 3s Cfc4 for Case C, 3s to 4s Table 26.10-1; Kh = Table 26.6-1, Directionality Factor, Kd Section 26.8.2, Topographic factor, Kzt Velocity pressure, qz = qh = 0.00256 Kz Kzt Kd Vasd2 = 1.00 0.53 <2; Case C doesn't apply 1.54 0.00 0.00 0.00 0.00 0.85 0.85 for freestanding signs 1.00 47.3 psf Section 26.11 gust effect factor, G 0.85 Design wind pressure (Case A) = qz G Cf = 62.1 psf Eq. 29.3-1, F = qh G Cf As Case A and Case B, FAB = 7454 lb Case C, F1= qh G Cfc1 sZ = 0 lb applied s/2 = Case C, F2 = qh G Cfc2 sZ = 0 lb applied 3s/2 = Case C, F3 = qh G Cfc3 s2 = 0 lb applied 5s/2 = Case C, F4 = qh G Cfc4 sz = 0 lb applied 7s/2 = Total force, EF, = 0 lb Lateral load, Flat = say qh G Cf Alat = 2018.74 lb (assumes Cf =1.00) 7.50 feet from end of sign 22.50 feet from end of sign 37.50 feet from end of sign 52.50 feet from end of sign [To �be`shown on construction documents: ULTIMATE DESIGN WIND SPEED, Vult(3-SECOND GUST): 160 mph' k RISK CATEGORY: II 4 'EXPOSURE CATEGORY: C DESIGN WIND PRESSURE: 62.1 psf_ 2 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590 118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL For One Support Pole: Case B ASCE 7, Fig. 29.3-1; FAB applied 0.213 = Torsion = FAB (0.213) = F applied 0.05h = Pole base moment, MxB = FAB(0.55)h = VXB = FAB = VyB = Flat = Pole base moment, MyB = VyB'(0.55h) = Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 1.60 feet from center of sign 11,926 ft-lb 0.75 feet above center 61,494 ft-lb* 7454 lb 2018.7 lb 16655 ft-lb* Case C Total load, Vxc = FAB = 0 lb Pole base moment, Mxc = Vxc (0.55)h = 0 ft-lb* Torsion, T = F1(13/2-s/2) + F2 (13/2-3s/2) + F3 (13/2-5s/2) + F4 (13/2-7s/2) T= 0 ft-lb VyB = Flat = 2018.7 lb Pole base moment, MyB = VyB (0.55h) = 16654.6 ft-lb* Vx = Mx= Torsion My= Vy = ** Resultant V=(Vx2+Vy2)1/2 = ** Resultant M=(Mx2+My2)1/2 = Case B Case C Maximum 7,454 0 7,454 61,494 0 61,494 11,926 0 11,926 16, 654.6 16, 654.6 16,655 2,018.7 2,018.7 2,019 7722 2019 7,722 63709 16655 63,709 lb ft-lb at grade* ft-I b ft-lb at grade* lb lb ft-lb at grade* * Moment is greater below grade; see drilled pier design ** Use resultant base shear and moment for drilled pier design For load combination 1.0 DL+0.6 Wind Vx = 4,472 lb Mx = 36,896 ft-lb at grade* Torsion 7,156 ft-lb My = 9,993 ft-lb at grade* Vy = 1,211 lb ** Resultant V=(Vx2+Vy2)1/2 = 4,633 lb ** Resultant M=(Mx2+My2)1/2 = 38,226 ft-lb at grade* 3 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: 121 S. Kings Hwy, Ft. Pierce, FL For short, free -head pier in cohesionless soil Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 Lateral load applied to pile at grade, Pa = 4,633 lb Torsion, T= 7156 ft-lb Moment applied to pile at grade, Ma = 38,226 ft-lb Resolve Pa and Ma into a load applied at a height a above grade e = M/P = 8.3 feet Diameter of the pier, b = 30 inches = 2.5 feet Note: Thomas Sign's standard truck -mounted augers are 18, 30 and 36 inches diameter X 14' max depth, 48" diameter x 6' max depth and the hand-held power auger has 6", 8" and 12" diameter bits. Embedded length below grade, L = 7.0 feet Assume angle of friction, � = 30 degrees Rankine coefficient of passive pressure, Kp = tan 2(45+�/2) = 3.00 Unit weight of soil, y = 110.0 pcf Using Brom's method: The load that will cause soil failure, Pt = pbL3Kp/2/(e+L) = 9277.9 lb Pt >= Pa; OK Distance from grade down to the point of zero shear (max moment), f = (2Pa/(3 Y b Kp)1"2 = 1.93 feet Mmax = Pa (e+f) - Pa f /3 = 44,203 ft-lb Moment magnification = Mgrade/Mmax = 1.156 Check stresses in the sign pole embedded in concrete pier. Perimeter area of pier, Ap = 27c(b/2)(12L) = 7917 sq in Shear on soil -concrete interface=12T/(b/2)/Ap = 0.72 psi x144 = 104 psf average soil pressure =110 pcf(L/2) = 385 psf say friction coeficient, fr = 0.3 friction force = 115.5 psf Factor of Safety against turning =115.5 / 104 = 1.11 > 1.00; OK The auger -drilled pier spreads support reactions from the main steel support onto the supporting soil, but does not directly carry structural shear or bending moments. Those forces remain in the main support, embedded in the pier. So the concrete does not need to be reinforced to carry the loads. 4 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Check: ASTM A�8,feFyP p Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 46 ksi W (Ib/k) A OD ID tnom ta", Dlt Ix 28.6 7.85 8.63 7.98 0.322 0.3 28.8 68.1 Zx Sx rx l y ZY SY ry J 20.8 15.8 2.95 68.1 20.8 15.8 2.95 136 From drilled pier design, Max Resultant Moment, M = 44,203 ft-lb Resultant Lateral load on pole, Rb = 4,633 lb Torsion, T = 7,156 ft-lb Free length of cantilever, h = 15.00 feet Center of load applied above grade, H = 0.55h = 8.25 feet Weight of sign = 840 lb AISC Table B4.1, sect 15 DA = 28.80 ° In compression; Xr = 0.11 E / Fy = 69.35 >DA; non -slender element In flexure; Xp = 0.07 E/Fy = 44.13 Xr = 0.31 E/Fy = 195.43 compact section AISC Chapter E; Compression AISC Section El Qc = 1.67 AISC Section E2 Effective length factor, K = 2.10 for cantilever KI/r = K(12H)/rx = 70.47 AISC Section E3 4.71 (E/Fy)1/2 = 118 >= KI/r AISC Eq. E3-4; Fe = 57.6 ksi AISC Eq. E3-2; Fcr = 32.9 ksi AISC Eq. E3-1; Pn = Fcr Ag = 259 kips Allowable compression strength, Pc = Pn/S2c = 155 kips Pole weight 28.6 Ib/ft H 8.25 feet Weight of pole = 236.0 lb Weight of sign = 840 lb Required compression, Pr = 1076.0 Ib = 1.08 <= 155; OK 1.08 kips 5 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 AISC Chapter F; Flexure AISC Section F8 Section F8.1; Yielding Sib = 0.45 E/Fy = Eq. 178-1; Mn = Mp = FyZ = Structural. Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 1.67 283.7 D/t < 0.45 E/Fy; Sect F8 Applies 957 kip -in Section F8.2; Local Buckling For compact sections Section F8.2 does not apply For non -compact sections; Eq. F8-2; Mn = 1,061 kip -in For slender walled sections; Eq. F8-3; Mn = 5,250 kip -in Mn = 957 kip -in Allowable moment, Mc = Mn/S2b = 573 kip -in Required moment, Mr = 44,203 ft-lb = 530 inch -kip 530 <= 573; OK AISC Chapter G; Shear nv = 1.67 Section G6; Lv is undefined since transverse shear is constant Section G6; Eq. G6-2a; Fcr = N/A Eq. G6-2b; Fcr = 146 ksi Vn = Fcr Area / 2 = 574 kips Allowable transverse shear, Vc = Vn/Qv = 344 kips Required transverse shear, Vr = 4,633 lb = 4.63 kips inch -kip 4.63 <= 344; OK 6 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 AISC Chapter H; Combined Forces Section H3.1 S2t = 1.67 Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 Prepared by: John F. Dougherty Florida P.E. License No. 80640 HSS torsional constant, C = 7t(OD-t)2t/2 = 32.70 Fcr is largest of eq. 1­13-2a and eq. H3-2b but shall not exceed 0.6Fy Eq. 1­13-2a; Fcr = 158 ksi Eq. 1­13-2b; Fcr = 112.8 ksi 0.6 Fy = 27.6 ksi Use Fcr = 27.6 ksi eq 1­13-1; Tn = Fcr C = Allowable torsion, Tc = Tn/Ot = Required torsion, Tr = 7,155.6 ft-lb = 902.5 in -kip 540.4 in -kip 85.87 inch -kip 85.87 <= 540; OK AISC Section H3.2; eq. 1­13-6 (Pr/Pc)+(Mr/Mc)+((Vr/Vc)+(Tr/Tc)}2 <=1.00 0.96 <= 1.00; OK Deflection Deflection due to load Rb, A = Rb (12H)3/(3EIx) _ 2(12H)/120 = * Uses span = 2H in accordance with building code for cantilevers Acceptable Shape �Pipe10STD Pipe10STD Pipe8STD _Pioe8STD OD (in) Wall (in) 10.8 0.365 10.8 0.365 8.63 0.322 8.63 0.322 Material 0.76 inches 1.65 inches* OK 40.5 ASTM A500 Grade C 40.5 ASTM A500 Grade B •28.6 ASTM A500 Grade C 28.6 ASTM,A500 Grade B Stress Defl'n Ratio Ratio 0.536 0.2071 0.588 0.962 0.460 lightest, selected 1.057 0.460[— 7 of 11 9/28/21 THOMAS Structural Calculations Sign & Awning Company, Inc. Client: Wawa #5380 Ft. Pierce 4590 118th Avenue North Project Identity No.: 85144 Clearwater, Florida 33762 Design No.: 78767 Florida Certificate of Authorization No. 31751 Prepared by: John F. Dougherty Florida P.E. License No. 80640 Installation Location: 4787 Radio Rd., Naples, FL Attachment of Channel Letters to face of sign Size of letters Ww a logo Height 2.17 1.67 1.33 feet Width 2.33 1.42 2.10 feet Area 5.055 2.366 2.805 sq. ft. Letter thickness 0.417 0.417 0.333 Max dimension 2.33 1.67 2.10 Area 0.972 0.696 0.701 sq. ft. Design wind pressure = 62.1 psf Normal Force Ww a logo Area (sq ft) 5.05 2.37 2.80 Wind pressure (psf) 62.1 62.1 62.1 Design force (lb) 314.0 147.0 174.2 No of anchors per letter 4 3 4 Force per anchor 78.50 48.98 43.56 lb tension Tension in bolts is 100% 100% 100% comprised of wind load Shear Force Ww a logo Area (sq ft) 0.97 0.696 0.701 Wind pressure (psf) 62.1 62.1 62.1 Design force (lb) 60.4 43.2 43.6 No of anchors per letter 4 3 4 Force Fws per anchor (lb) 15.10 14.41 10.89 wind shear Say letter weighs 5 psf, then 25.27 11.83 14.02 Ibs No of anchors per letter 4 3 4 Gravity force Fg per anchor (lb) 6.32 3.94 3.51 gravity shear Total shear force = 21.41 14.94 14.40 lb total shear Shear is 30% 7% 24% comprised of dead load and 70% 93% 76% comprised of wind load Ww a logo For load combination 1.0 DL + 0.6 Wind: 47.1 29.4 26.1 lb tension 15.4 10.7 9.04 lb shear Standoff distance from face of wall 0.00 0.00 1.50 inches Bending moment in shaft of fastener 0.00 0.00 13.6 inch -lb 8 of 11 9/28/21 THOMAS Structural Calculations Sign & Awning Company, Inc. Client: Wawa #5380 Ft. Pierce 4590118th Avenue North Project Identity No.: 85144 Clearwater, Florida 33762 Design No.: 78767 Florida Certificate of Authorization No. 31751 Prepared by: John F. Dougherty Florida P.E. License No 80640 Determine required size of through bolts for the design forces: Design Forces: Ww Tension, PT: 47.1 a logo lb 29.4 26.1 Shear, P.: 15.4 10.7 9.04 lb Moment, M: 0.00 0.00 13.6 inch -lb Try Diameter = Q. inch Area = 0.04911 0.04911 0.0491 sq in For A307 galvanized bolts, tensile strength = 60,000 psi From "Steel Construction Manual," 13th ed., AISC, Table 7-1 Allowable tensile stress, Fnt/D = 22,500 psi Allowable shear stress, Fnv/Q = 12,000 psi For fastener in standoff application, with moment = shear x standoff distance: Assume O.D. of spacer sleeve = 2x fastener diameter WWI a I logo Spacer sleeve O.D. = 0.51 0.51 0.5 inch Resolve moment M into force couple with distance = spacer sleeve radius force in bolt due to M 0.00 0.00 54.24 lb Total Tension, P'T: 47.10 29.39 80.37 lb Tensile stress, ft = P'T/Area = 959 599 1637 psi Shear stress, fv = PS/Area = 313 218 184 psi Stress ratio = ft/(Fnt/n) + fv/(Fnv/0) = �!' 0.069 0.045 0.088 ! <= 1.00; <= 1.00; <= 1.00; OK -_ _OK OK i 9 of 11 9/28/21 THOMAS Sign & Awning Company, Inc. 4590 118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: 4787 Radio Rd., Naples, FL Digital Fuel Price Display Mounted to Face of Sign Size of digital price displays Height Width Area Structural Calculations Client: Wawa #5380 Ft. Pierce Project Identity No.: 85144 Design No.: 78767 1.83 0.00 feet 4.08 0.00 feet 7.49 0.00 sq. ft. 0.00 ft (display mounted flush to sign face, not Sign thickness exposed to lateral wind load) Max dimension 4.08 For wind parallel to wall, Area = 0.00 sq. ft. Normal Force Max Area (sq ft) 7.49 Wind pressure (psf) 33.9 Design force (lb) 253.6 No of anchors Force per anchor 31.7 lb tension Tension in bolts is 100% comprised ofwind load Shear Force Area (sq ft) 0.00 Wind pressure (psf) 62.1 Design force (lb) 0.0 No of anchors 8 Force Fws per anchor (lb) 0.00 wind shear Sign area 7.49 sq. ft. Assumed unit weight of sign 5 psf Weight of sign, say 37.4 Ibs No of anchors 8 Gravity force Fg per anchor (lb) 4.68 gravity shear Total shear force = Fws+ Fg = 4.68 lb'total shear Shear is 100% dead load and 0% wind.load !_r For load combination 1.0 DL + 0.6 Wind: 19.02 lb tension] I 4.68 Ib shear 10 of 11 9/28/21 For #10 self -tapping sheet metal screws, screw head in contact with 1/8" alum. mounting plate and screw head not in contact with 1/8" steel angle framing See ICC Evaluation Service Evaluation Reports: ICC ESR-3223 ITW Buildex TEKS ICC ESR-2196 Hilti Self -Drilling ...Screws ICC ESR-1976 ITW Buildex Self -Drilling Fasteners ESR-3223 ESR-2196 ESR-1976 Tensile Pull -Out 404 lb Table 2 Table 2 254 lb Table 2 303 lb Tensile Pull -Over 714 lb Table 3 Table 3 943 lb Table 3 1125 lb Allow. Fast'r Tension Table 4 866 lb Table 5 455 lb Table 5 2654 lb Allow. Fast'r Shear 536 lb Table 4 Table 5 405 lb Table 5 1718 lb Allow. Shear (Bearing) 475 lb Table 5 Table 4 807 lb Table 4 962 lb Use allowable tension = 254 lb and allowable shear = 405 lb Stress ratio =19.0 / 254 + 4.7 / 405 = 0.09 <= 1.00; OK 11 of 11 9/28/21