HomeMy WebLinkAboutHealth Dept finalSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
APPLICANT: Coastal Palms Construction
AGENT. Atlantic Land Designs of the TC
PROPERTY ADDRESS: 10327 Muller Rd Fort Pierce, FL 34945
APPLICATION #:AP1613379
PERMIT #:56-SF-2221690
DOCUMENT #:F11786275
DATE PAID : 02/03/2022
FEE PAID:95.00
RECEIPT #:56-PID-5448250
LOT: 1
BLOCK:
SUBDIVISION:
ID # : 2334-701-0001-000-1
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH
STATUTE OR
RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [1] 1090.00 [21
[ ] [271
SURFACE WATER
FT
[ ] [021
TANK MATERIAL Polypropylene
[ ] [281
DITCHES 110
FT
[ ] [031
OUTLET DEVICE
[ ] [29]
PRIVATE WELLS 85
FT
[ ] [041
MULTI -CHAMBERED [LIJ N ]
[ ] [301
PUBLIC WELLS
FT
[ ] [051
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS
FT
[ ] [061
LEGEND 1. 70-143-11DC4 2.
[ ] [321
POTABLE WATER 12
FT
[ ] [071
WATERTIGHT
[ ] [331
BUILDING FOUNDATIONS 8
FT
[ ] [081
LEVEL
[ ] [341
PROPERTY LINES 100
FT
[ ] (091
DEPTH TO LID
[ ] [351
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [101
AREA [1] 672 [21 SQFT
[ ] [361
DRAINFIELD COVER
[ ] [111
DISTRIBUTION BOX HEADER X
[ ] [371
SHOULDERS
[ ] [121
NUMBER OF DRAINLINES 1. 8.00 2.
[ ] [381
SLOPES
[ ] (131
DRAINLINE SEPARATION
[ ] [391
STABILIZATION 02/15/2022
[ ] [141
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL
INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 1.00
[ 1 [401
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION
[ ] [41]
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS
[ ] [421
ALARMS
[ ] [191
AGGREGATE SIZE
[ ] [431
MAINTENANCE AGREEMENT
[ ] [201
AGGREGATE EXCESSIVE FINES
[ ] [441
BUILDING AREA
[ ] [211
AGGREGATE DEPTH
[ ] [451
LOCATION CONFORMS WITH SITE PLAN
[ ] [461
FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ ] [221
FILL AMOUNT
[ ] [471
CONTRACTOR Roselis Moctezuma (All Coas
[ ] [23]
FILL TEXTURE
[ ] [481
OTHER INFILTRATOR Quick4 EQ36 (single c
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED
[ ] [49]
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL
[ ] [50]
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
/
` - St. Lucie CHD
DATE: 02/03/2022
CONSTRUCTION
[ APPROVED
DISAPPROVED
] ' Environmental Specialist Ma S V i (Florida Department of He
FINAL SYSTEM
[ APPROVED / DISAPPROVED
] . St. Lucie CHD
DATE: 02/15/2022
En tronmen al peciali Matth a i (Florida Department of H
(Explanation of Violations on following page)
.
DH 4016, 08/09
(Obsoletes all previous
editions which may not be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1
AP1613379 EID2221690
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1613379
PERMIT #:56-SF-2221690
DOCUMENT # : F 11786275
DATE PAID : 02/03/2022
FEE PAID:95.00
RECEIPT #:56-PID-5448250
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, and 8x7 long BED DF installed. Violations observed. Not enough excavation. Contractor notified by phone.
Contractor sent disapproval letter. Re -inspection required.
New ST, filter, and 8x7 long BED DF installed. No violations, system ok to cover. Contractor notified by phone. Needs final
inspection for well inspection, mound system, depth of cover, and final site grading.
Final inspection completed. Mound system and depth of cover checked, well inspection and final site grading completed.
Final inspection approved. Emailed copy to building department and contractor.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1613379 EID2221690