HomeMy WebLinkAboutAC Duct Drawing(3)Job #: 1624
Performed by Chris Bateman for:
Cialiani Residence
TBD Balsam Dr
Fort Pierce, FL 34982
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
vickilynne@aircalcs.com
Scale: 1 : 111
Page 1
Right-Suite® Universal 2021
21.0.08 RSU29066
2021-Sep-24 13:13:08
... HVAC\TBD Balsam Dr PSL Prop.rup
N
Level 1
Garage
Bed 2
Bath
Bed 3
Hall
Kitchen
Great Room
Office Foyer
Master Bed
Hers
His
Master Bath
Dining Room
Laundry
Wtr Clst
H/W
F
F
F
50 CFM
4" Duct
4" Exhaust Vent
120 CFM
6" Duct
6" Exhaust Vent
50 CFM
4" Duct
4" Exhaust Vent
DUCTS IN THE GARAGE AND
DUCTS PENETRATING THE
WALLS OR CEILINGS
SEPARATING THE DWELLING
FROM
THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM
NO.
26 GAGE (0.48 MM) SHEET
STEEL, 1 INCH MINIMUM RIGID
NONMETALLIC CLASS 0 OR
CLASS 1 DUCT BOARD, OR
OTHER APPROVED MATERIAL
AND SHALL HAVE NO
OPENINGS INTO THE GARAGE
12 x 12
101 cfm
30 x 18
1042 cfm
12 x 8
133 cfm
10 x 6
196 cfm
10 x 10
129 cfm
10 x 10
121 cfm
10 x 10
121 cfm
8 x 4
4 cfm
10 x 10
141 cfm
10 x 6
55 cfm
8 x 8
62 cfm
6 "
12 x 8
133 cfm
6 "
4 "
5 "6 "
6 "
6 "
10 x 6
101 cfm
10 x 6
85 cfm
12 x 12
203 cfm 12 x 8
203 cfm
16 x 16
16 x 16
270 cfm 14 "
16 "
6 "
8 "
8 x 4
39 cfm
4 "
12 "
10 "
10 "
5 "
5 "
8 "
6 "
8 "
12 "
8 x 8
100 cfm10 x 10
129 cfm
8 x 8
100 cfm
6 "
6 "
6 "
6 "