HomeMy WebLinkAbout2-16 WORK SHEET FOR RD 98 LLCST. LUCIE
Section A (General Information)
Master Permit No.
Process No.
Contractors Name: 1
Job Address N�c�
L=e Vnn,r r License#
,vq &V F22A
Cep�"33 l3a
V61
ROOF CATEGORY
�
El"Low Slope
❑ Mechanically Fastened Tile
❑ Mortar/Adhesive Set Tiles
❑ Asphaltic Shingles
etal Pan /Shingles
❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair
❑ Maintenance
Er"Reroofing ❑ Recovering
Low Slope Roof Area (SF)at
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) [� a� Total (SF) oZ�
Section 8 (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: V5.1 }
Product Approval No.: EL��{=W��
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: ___ Zone 2: —Zone 3: —Z
Max. Design Pressure, from the specific product approval
system: __ (A by 9%)• C
Deck:
Type.-_
11
Gauge Thickness:. V-,-,
Slope: 41 2 1�2
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bon-d�ng Material:
Insulation Base Layer:p
Base Insultation Size and Thickness: —WAN--
Base Insulation Fastener/Bonding Material:
N/,1+
Top Insulation Layer: N/tr;
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No, of Ply(s): -C
Base Sheet Fastener/Bondin Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply: 0
Top Ply Fastener/Bonding Material.
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows—
@ .00
Zone 1:—"
oc @ Lap, # Rows
, @ _$ oo
Zone 2:._.._."
oc @ Lap, # Rows
— @ " ac
Zone 3:—"
oc @ Lap, # Rows____.
@ 00
-Number of Fasteners Per Insulation Board:
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterf lashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.,
FT.
Parapet
Height
I
FT,
Mean
Roof
Height
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: a:!-') n� L-4
Notice of Acceptance Number: I '
Fl a9L[L4q
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:��Zone 2e: Zone 2n:1lone 2r: Zone 3e:4IZone 3r:
Deck Type:
Type Underlayment:
Roof Slope:
--- ----- Insulation: 1IlI�vII _I
Fire Barrier:
Ridge Ventiiatinn7 Fastener Type & Spacing:
,Adhesive Type:
fir`` �,. c• rr. s4 S� ca
Type Cap Sheet:
Mean Roof Height: 5 Roof Covering: e �•, �-�� c� Vve
Type & Size Drip ✓ K�r 'J
Edge: =+
1
2
3
0
�+ J
Cl)
0 0
14 0
LU
U
W J
co
V �
Y
z
C
�.Q
U
U
U
0
�
CV
N
s
Z
W
z
W
W
A
CL
d
J
o
L
Z
Z
U)y
L
W
S
Q
W
=
Q
N
LL
w
LL
w
O
U)
N
N d
A
------------
o
44 a
LO
LO
0O
CD
o
c =
J
u-
LL
J
a`
LL
E
a
/
z'
m
G
CO
m
(n
a
f
M
N
5
p
h
N
'c
r
o
d
z
o
�
w
i
9 �
N �
N
a d
g a
� c
0
a' o
c
o
� �
rn �
Q0
r
C `
m a
�
�
O
Y
N
H
8
O
m
`
o
w
0@
°o
o
0
V' �
y
L
10
m
Ot
n
o
co_
2
v
LL
m
c
m u
m
3