Loading...
HomeMy WebLinkAboutOSTDS - SewageSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION PERMIT # DOCUMENT #SE1635153 56-SF-2444746 AP1784412APPLICATION # APPLICANT: LOT: ID#: BLOCK: SUBDIVISION: Scott & Mary Jakab CONTRACTOR / AGENT:Reliable Septic & Service TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. X ]YES[]NO[NET USABLE AREA AVAILABLE:0.30PROPERTY SIZE CONFORMS TO SITE PLAN:ACRES TOTAL ESTIMATED SEWAGE FLOW:200 GALLONS PER DAY [RESIDENCES-TABLE1 ]OTHER-TABLE 2/ AUTHORIZED SEWAGE FLOW:450.00 GALLONS PER DAY [1500 GPD/ACRE ]2500 GPD/ACREOR UNOBSTRUCTED AREA AVAILABLE:675.00 SQFT UNOBSTRUCTED AREA REQUIRED:375.00 SQFT BENCHMARK/REFERENCE POINT LOCATION:Site BM #1 at elevation: 12.48 10.00ELEVATION OF PROPOSED SYSTEM SITE [BELOW ] BENCHMARK/REFERENCE POINTABOVE/[INCHES ]FT/ THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:FT DITCHES/SWALES:FT ]YES[X ]NO[NORMALLY WET: PUBLIC:FT LIMITED USE:FTWELLS:PRIVATE:76 FT NON-POTABLE:FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:15 FT POTABLE WATER LINES:27 FT ]YES[X ]NO[SITE SUBJECT TO FREQUENT FLOODING?]YES[X ]NO[10 YEAR FLOODING? 10 YEAR FLOOD ELEVATION FOR SITE:FT []MSL NGVD/SITE ELEVATION:FT [ ] MSL NGVD/ 1428-703-0013-000-9 023 & 4 TextureMunsell #/Color Depth 10YR 5/2 Sand 0 To 19 10YR 6/2 Sand 15 To 19 10YR 5/3 Sand 19 To 28 10YR 4/4 Fine Sand 28 To 38 10YR 3/6 Fine Sand 38 To 57 REFUSAL Refusal 57 To 72 TextureMunsell #/Color Depth 10YR 5/2 Sand 0 To 23 10YR 6/2 Sand 17 To 23 10YR 5/3 Sand 23 To 31 10YR 4/4 Fine Sand 31 To 43 10YR 3/6 Fine Sand 42 To 56 REFUSAL Refusal 56 To 72 SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES: USDA SOIL SERIES: EXISTING GRADE EXISTING GRADE TYPE: 15 OBSERVED WATER TABLE:51.00 [BELOW ]ABOVE /[APPARENT ]PERCHED /INCHES ESTIMATED WET SEASON WATER TABLE ELEVATION:[BELOW ]ABOVE /INCHES HIGH WATER TABLE VEGETATION:]YES[X ]NO[X ]YES[]NO[MOTTLING:DEPTH:15.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING:Sand/0.80 DEPTH OF EXCAVATION:INCHES X ] TRENCH[] BED[] OTHER (SPECIFY)[DRAINFIELD CONFIGURATION: SHS determined by >10% 10YR 6/2 stripping in a 10YR 5/2 matrix at 15 inches in site 1. Refusal due to saturation in both sites. BM: 3'7" S1: 4'5" S2: 4'3" REMARKS/ADDITIONAL CRITERIA Page 3 of 4 SITE EVALUATED BY:DATE:12/29/2021 Moore, Ian (Title: CEHP 19-2072) (Soiled It, LLC) DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC v 1.0.2AP1784412EID2444746