HomeMy WebLinkAboutProduct Approval GAF Roofing Underlayments NEMOletc.
Certificate of Au horization#32455
353 Christian Street, Unit#13
0#ord,CT 06478
203)262-9245
ENGINEER EVALUATE TEST CONISULT
^' �^ •�,r,, ®",,.�, ,yam "7
�'°',4...".�,MW7
777771
•.^^�"�. -'.�'..-••„�..•,
ZTy
GAF Evaluation Report 01506.04.08-1123
1Campus Drive FL10526-R23
Parsippany, NJ 07054 Date of Issuancg:04/25/2008
(800)766-3411 Revision 23:12/14/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governJng the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Roert Nieminen,
P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume The products
described herein have been evaluated for compliance with the 71h Edition(2020) Florida Building Code'�ections noted
herein.
DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes, he referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the proc uct(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to:the product(s)', the,atfality Assurance or the-production.facility I caton(91. NEUCr ETC;' LC"requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#)preceded bythe words"NEMO Evaluated"rri y be displayed
in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its ntirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the m nufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M.Nieminen,P.E. The facsimile seal appearing was aud orized by Robert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E.on 12/14/2021.This:does not serve as an
"f%• ";'"' electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company', anufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evak ates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distribi.ting products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
prgd uct., '
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer Pf Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2619 NEMO ETC,LLC
04N
imoletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments,as produced by GAF,have demonstrated compliance with the
following sections of the 7th Edition(2020) Florida Building Code through testing in accordance with! he following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
Section Property - Standard Year
1504.3.1 Wind resistance FM 4474 201d
1507.1.1,1507.2.4,1507.2.9.2/R905.1.1, Material standard ASTM D1970 201
R905.2.8.2
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tear Strength ASTM D4533 201
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 20il
R905.1.1.1(2&3,Exception),R905.1.1.1{5)
1507.1.1.1(5)111905.1.1.1(5)- Liquid WatehtnMMistioh' AS-ri D4869 2016
1507.1.1/R905.1.1 Material standard ASTM D6757 2016
1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2038
1507.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference Date
ERD(TST6049) ASTM D1623&FRSA/TRI (Slippage) G34150.08.11 11 114/11
ERD(TST6049) ASTM D6164(GA) G40630.01.14-26-112 01 i07/14
ERD(TST6049) ASTM D6164(GA) G46160.09.14-3A 09 i09/14
ERD(TST6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03f,01/17
ERD(TST6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03f 01/17
ERD(TST6049) ASTM D1970(GA). GAF-SC13285.03.17-1 03,03/17
ERD(TTST60491 A5TM-D1970(lU� GAF-SC15440.1217 121,31/17
Intertek(TST1558) ASTM D4869(Dadra,India) F8549.02-106-18 11),08/16
NEMO(TST6049) Physical Properties(ON) 4q-GAF-I9-SSMBB-03.A 05 13/19
NEIVIO(TST6049) ASTM D1623 4p-DOW-I9-SSLAP-OI.A-R2 10,01/19
NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/,01/20
NEMO(TST6049) ASTM D1970 _4j-GAF-20-SSUDL-01.A 12/22/20
NEMO TST6049 ASTM 84798,TAS 103 4-GAF-20-SSUDL-02.A 03 15/21
NEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/21
PRI(TST5878) ASTM D226(OK) GAF-339-02-01 03 13/12
PRI(TST5878) Wind Uplift GAF-434-02-01 09 16/13
PRI(TST5878) Wind Uplift GAF-434-02-03 09116/13
PRI(TST5878) Wind Uplift GAF-434-02-04 09%16/13
PRI,(TSTS878) ASTM D4533(various) GAF-818-02-01 12/OS/17
PRI`(TST5878) ASTM'D1970,(AL) 'MSA-047-0241 04/11r18
PRI(TST5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/04/18
PRI(TST5878) ASTM D4533(Dadra,India) GAF-914-02-01 04411011.9
PRI(TST5878) ASTM D4533,D5035(VA) 376TOO12 07/15/19
PRI(TST5878) ASTM D4533(Parzai,India) 376TOO18 07/31/19
PRI(TST5878) ASTM D4533(Umerkui Kilvani,India) 376TOO18 07/31/19
PRI(TST5878) ASTM D1970(AR) 376T0032 1OV22/19
PRI(TST5878) ASTM D4533(Gujarat,India) 376TOO58 02%18/20
NEMO ETC,LLC Evaluation Report 01506.04.08-1123
Certificate of Authorization#32455 7-1 EDITION(2020)FBC NON-NVNZ EVALUATION FL10626-R23
GAF Roof Underlayments Revision 23:12/14/2021
Page 2 of 8
i
04N, Ojetc.
Enti Examination Reference Da
PRI(TST5878) ASTM D226(S-CA) 376T0054 02/18/20
PRI(TST5878) ASTM D5035(various) 376TO103 09/ 1/20
PRI(TST5878) ASTM D4533,D5035(Rajasthan,India) 376TO111 12/72/20
PRI(TST5878) ASTM D4533,D5035(Gujarat,India) 376TO113 12/22/20
PRI(TST5878) ASTM D5035(Gujarat,India 376TO146 03/ 1/21
PRI(TFSfS87sk ASW.Q4S ,DO (Rajasthafr,.lndi } 7ErTQCY. 0 /.. 7/ Y.
PRI(TST5878) ASTM D226,Type II 376TO192 09/!6/21
NEMO Traceability FBC Cross-Listing 04/ 2/20
NEMO Traceability FBC Cross-Listing 04/ 8/21
UL,LLC(QUA9625) Quality Control Service Confirmation(AL) 05/ 4/20
UL,LLC(QUA9625) Quality Control Service Confirmation(various) 06/ 0/21
UL,LLC(QUA9625) Quality Control Florida BCIS Curl,ent
ZENOM, a a ,swu- x ,#A I
Product Material Standard Plant(s)
4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Capada
4.2 Liberty'"SBS Self-Adhering Base/Ply ASTM D1970 Mt.Vernon;IN
Sheet Savannah, A
4.3 StormGuard®Film-Surfaced Leak Barrier ASTM D1970(Table 1)1 Mt.Vernon IIN
Savannah,((A
WLaattrerWatchol".Mhreraf SurFaced:Leak Arkadelphia,IAR
4.4 Barrier ASTM D1970 Savannah,GA
Tuscaloosa,AL
Deck-ArmorTM Premium Breathable Roof 1507.1.1.1(2&3,Exception)/ 1
4.5 Dadra,India
Deck Protection R905.1.1.1(2&3,Exception)
Dadra,India
Gujarat,In ra
75a :x'x'1( 8`3:C S ptiarrr` (CPP)Rajasthanr India
4.6 FeltBuster®Synthetic Roofing Felt 1507.1.1.1(5)/R905.1.1.1(2&3, (MIP)Rajasthan India
Exception),R905.1.1.1(5) Richmond, rA
Spartanburgl'SC
4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,0111
.5hpft;gr,iCA,
i'5071.1.1(2&%Ekceptidih)"�
4.8 StormSafe'""Anchor Sheet R905.1.1.1(2&3,Exception) North Bay, N
Dadra,Ind a
4.9 Tiger Pawl Premium Roof Deck 1507.1.1.1(2&3,Exception)/ Gujarat,India
Protection R905.1.1.1(2&3,Exception) Parzai,Ind a
Urnerkui Ifilva.n;.India
410 VbrsaSfiiefd--FFre-Resfstant'Roof Deck ASTM D226,Type II lConover,)�C
Protection
4.11 Ruberoid®Mop Granule ASTM D6164 Savannah, A
FRSA/TRI 09-18
4.12 RuberoidIF Mop Granule€R ASTM D6164 -Savannah,,43A
FRSAII&
StormGuard®Film-Surfaced Leak Barrier has been found through comparative testing to have a lesser coefficient offrictioi than ASTM
D226 roofing felt when tested at standard laboratory conditions. Agreement between purchaser and seller,as set forth in 5lection 4.3,Note
1 of ASTM D1970-15,should be established as to slip resistance.
NEMO ETC,LLC Evaluation Report 01506.04.08-R23
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1123
GAF Roof Underlayments Revisia 23:12/14/2021
Page 3 of 8
0I
I
i
I
NAM®I etc.
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way, he Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used fdr permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Browarc and Miami-
Dade Counties).
5.3 This Evaluation-Report.pertains to above-d;eck roof components. Roof decks and structural members shall be in
accardancewitlT FBC requireme,nts.ta:the satisfaction.-of the Authority UavingJtmsdictian,
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Ju isdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1507.3 1507.4 and 1507.5 1507.7 1507.8 and 1507.9
Asphalt Clay and Concrete The Metal Slate or Wood
Underlayment Mechanical Adhesive- Slate-Type
Shingles Attach Set Panels Shingles Shingles Shingles Shakes
Yd� Yes
GAF Extended Dry-In Membrane Yes No No Yes Yes Yes Writ strps, Qolntstrips,
1507.1.1.3/ 1507.1.1.3/
R905.1.,1.3) R905.1.1.3)
Liberty-SBS Self-Adhering Ye Yes
Yes No No No No No QOints ps, (joint strips,
�as�t.Plx.she�X �soi�. s t _ xsuz,x,�3/
Yell Yes
StormGuard®Film-Surfaced Leak (joints 'ps, (joint strips,
Yes No No Yes Yes Yes
Barrier R905113) R905113)
Yes Yes
WeatherWatch°Mineral-Surfaced
Leak Barrier Yes No No No No No (Joint si 1507.1 n3s/ 1507.113s/
•._R905.1.1.3).
Deck-Armor°
-- . _ --...a_._---------'--'- -'----------------_—._----
Premium m Breathble Yes No No Yes Yes v Yes N No
Roof Deck Protection
FeltBuster°Synthetic Roofing Felt Yes No No No No No N No
Shingle-Mate®Roof Deck Yes No No No No No NQ No
Protection
Tiger-Paww Premium Roof Deck
Yes No No Yes, Yes Yes- No No-
Protection
VersaShield®Fire-Resistant Roof Yes No No No No No No No
Deck Protection l
Yes Yes
Ruberoid°MopGranule No (Cap Sheet in
(Cap Sheet in 2-plysystem) No No No N No
2-ply system)
See 5:6:1
Yes Yes
Ruberoid°MopGranule FR No (Cap Sheet in
(Cap Sheet in 2-ply system) No No No N No
2-ply system)
See 5.6.1
NEMO ETC,LLC Evaluation Repo 01506.04.08-R23
Certificate ofAutharization#32455 71"EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1123
GAF Roof Underlayments Revisi n 23:12/14/2021
Page 4 of 8
0, 1141. m®I etc.
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS2 j
Underlayment Adhesive Florida Pro uct Approval
Ruberoid®Mop Granule;Ruberoid°Mop Granule FR Dupont'Tiile Bond'Roof Tile Adhesive" FL2. 2525
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Primer Substrates
GAF Extended Dry-In Membrane self-adhering None plywood
Liberty'""SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering (Optional} plywood
ASTM D41
Weather Watch®Mineral-Surfaced Leak Barrier
Liberty'"SBS Self-Adhering Base/Ply Sheet
Star,mGuard�FHM7Surfaced=Leah Barrier :seifradtterissg RrarTis ASTlVr D226 felt,Type 1
Weather Watch®Mineral-Surfaced Leak Barrier
Liberty—SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering ASTM D41 metal(flashing metal,valley metal,
etc.)
Weather Watch®Mineral-Surfaced Leak Barrier
Ruberoid®Mop Granule
hot asphalt ASTM'D41 structural concrete
Ruberoid°Mop Granule FR
Ruberoid®Mop Granule hot asphalt None GAFGLAS®#80 Ultimo Base Sheet
Ruberoid®Mop Granule FR or Ruberoid®20 Smooi h
51� Attachment Limitations:
5.9.1 Foruso undar.mL*Chanicattyattachad'N U=TILE prepared:raofcaverfrigs;attach niorit ;halt be in ac ardaricewith.
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than.FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufactures installation
instructions, but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High 1Mnd Concrete and Clay Roof Tile installation Manual,.Sixth Edition Appendix A,
Table 1 (for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
Thefollowing wind uplift°limitations apply-to underlayment systems that are not prescriptive in the fRSA/TRI
Florida High Wind Concrete and Cloy Roof Tile lnstadotion Manual,Sixth Edition. The Maximum D sign Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ul imate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximpm de$Ign Pr(s§wrg for the selected essefn.hly shall meet car exegfd that reguired u, der FRSA/TRI
Florida High bind Concrete and Clay.Roof.Tile Installation-Manual,Sixth,Editiam,.Appendix A, I We 1A•or the
critical (highest)design pressure determined in accordance with FBC 1609 or FBC Residential Ch'�pter 3.
2 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistan a Performance.
NEMO ETC,LLC Evaluation Report 01506.04.08-1123
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10526-1123
GAF Roof Underlayments Revisi n 23:12/14/2021
Page 5 of 8
[V' m® etc.
#1 Maximum Design Pressure=-442.5 psf.
Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of AZGLAS
rity Having
Jurisdiction
Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet, Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot sphalt at 20
to 25 ibs/square.
Cap.Sheet: Ruberoid6 Mop-Granute-orRubero'rd°Mop Gr'ariWe FRappliedin full-mopping of AST 11312,Type
IV hot asphalt at 20 to 25 Ibs/square.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required Lin J er FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical _M
(hrghestj deign pressure-determinecl,in•a€€orlon€e witkrFS£164}'�..or F8£F�esic42rrt,iat Eha fer 3,.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at le7 the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated p essure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117, Assemblies marked with an asterisk* carry the limitations set fo h in Section
2.2.YO Y of FM Loss Prevention Bata-Sheet r=29;•(Fel7ruary2020)forentTarrcemerrts.
#2 Maximum Design Pressure=-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Aut ority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'' Base Sheet or Ruberoid® 20 Smooth mechanically attache with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spa d 9-inch o.c.
at the min.4-inch wide side Taps and 9-inch o.c.at two (2),equally spaced,staggere 'center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of AST D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Miry. 19/32-inch plywood to meet project requirements to, satisfaction of Aui ority. Having,
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima"' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spa�ed 8-inch o.c.
at the min.4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center rows
in the field of the sheet.
Cap%reet; .-Ruberoid&-MclyGrarruWor:RuheroidkMolx,,GranukeFRappliect.irrfuil'mopplrrgefA- :D3.12;.Typ-e
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Aut ority Having
Jurisdiction.
Base Sheet: GAFG LAS° "#80 Ultima' Base Sheet or RuberoidP 20 Smooth mechanically attache with 11 ga.,
-miiri._1.2S-inch Iong ring shank.nail5 through 32 ga., diarrteter-tirr caps spaced'4:-tract..cr:c.
at the min.2-inch wide side laps and 4-inch o.c.at four(4),equally spaced center rod s in the field
of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping ofASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
MEMO ETC,LLC Evaluation Report 01506.04.08-1123
Certificate o/Authorization#32455 77"EDITION(2020)FBC NON-ftyH2 EVALUATION FL10626-1123
GAF Roof Underlayments Revisi n 23:12/14/2021
Page 6 of 8
04N mo etc.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover. Maximum
Underlayment Exposure
Installation Type (days)
Deck-Armor"'"Premium Breathable Roof Deck Protection,FeltBuster®Synthetic
Roofing Felt,Shingle-Mate°Roof Deck Protection,StormSafeTMl Anchor Sheet,Tiger
Paw'"'Premium Roof Deck Protection,VersaShield®Fire-Resistant Roof Deck Mechanically attached 30
Protection,Libertr SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced
Leak Barrier and WeatherWatch°Mineral-Surfaced Leak Barrier
GAF Extended pry-in Membrane fVlecha111ca11Y attached 159
Adhesive-set the roof-system I 180
._L w- _`JNI _I n..L_.__ _I w ..1_
nuuei�lu- rviON Giaiiuie anu nuueiuiu- rviuN UT aiWIe ni
Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof aslemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using b�ttens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Flat Max.10-tile stack 4:12
Ruberoid®Mop Granule Fiat Max.6-tile stack(4 over 2) 5:�2
Lugged Max.10-tile stack 542
Ruberoid®Mop Granule FR Flat or Lugged Max.6-tile stack(4 over 2) 5:;112
Lugged Max.10-tile stack 4:112
I
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructi ns subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate horoughly to
remove any dust and debris prior to application and prime the substrate(if applicable).
6.3 Deck-Armor'" Premium Breathable Roof Deck Protection or Tiger PawTM Premium Roof Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4 FeltBuster®Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1 2,Exception),
1507.1.1.1(3, Exception)or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception),R905.1.1. (3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufactures installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
i
6.5 StormSafeT""Anchor Sheet:
6.5.1 StormSafeTm Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlay ent systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1., (2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
NEMO ETC,LLC Evaluation epoi,
01506.04.08-R23
Certificate of Authorization#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R23
GAF Roof Underlayments Revision 23:12/14/2021
Page 7 of 8
I
04NE� ® etc.
6.5.3 One the same day, install Liberty"`° SBS Self-Adhering Base/Ply; StormGuard® Film-Surfaced Lea Barrier or
WeatherWatch®Mineral-Surfaced Leak Barrier over the StormSafe""Anchor Sheet.
Shingle-Mate®Roof'Deck'Protection:'
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlay ent(ASTM
D226,Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared Zf covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precede ce over the
manufacturer's installation instructions.
6.7 VersaShield®Fire-Resistant Roof Deck Protection:
6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlay�nent(ASTM
D6757)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF:Extended Dry-In Membrane, Liberty"""SBS Self-Adhering Base/Ply Sheet,SiormGuard®Film-S rfaced Leak
Barrier or WeatherWatch®Mineral-Surfaced Leak.Barrier
6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASZ D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared• oof covering
to be installed,and the manufacturer's installation instructions.
6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch ox encaps lated within
min.4-inch side laps.
6.8.3 When installed over a mechanically attached,FBC Approved ASTM D226 Type 11 felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or 11905.1.1:
6.8.4 GAF Extended Dry-In Membrane, Liberty"'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film- urfaced Leak
Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlay' ent system.
6.9 Ruberoid®Mop Granule;Ruberoid®Mop Granule FR:
6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet"in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation anual, Sixth
Edition,and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the inst Ilation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requi ements. Refer
to Section 4 herein for products and production locations having met codified material standards'
:�' •, .1�3k>,'. F a.;����J�ayt ....'�.,y ', r-'yam"=,�°+a�*--lr..�',n"' ,�'k'^�'�}—'s`tW' �'�,w..wu.r�"".°�`,
UL,LLC.—QUA9625; (613)371-2765;Jacob.Stewart@ul.com
-END OF EVALUATION REPORT-
NEMO ETC,LLC Evaluation Repo 01506.04.08-1123
Certificate of Authorization#32455 77"EDITION(2020)FBC NON-HVHZ EVALUATION i 171-10626-1123
GAF Roof Underlayments Revi's on 23:12/14/2021
Page 8 of 8