Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
1/28/22, 1:48 PM Florida Building Code Online Business & iYl „ tIF _ ProfessionalRegulation r BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr �fl -lamProduct Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL36841 SFCRETARY Application Type New Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Atlas Roofing Corporation Address/Phone/Email 2000 Riveredge Parkway Suite 800 Atlanta,GA 30328 (770)946-4571 mcollins@atlasroofing.com Authorized Signature Meldrin Collins mcollins@atlasroofing.com Technical Representative Paul Casseri Address/Phone/Email 2000 Riveredge Parkway Suite 800 Atlanta,GA 30328 (678)402-9632 pcasseri@atlasroofing.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Certification Mark or Listing Certification Agency PRI Construction Materials Technologies Validated By Locke Bowden P.E. Validation Checklist- Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D1929 2016 ASTM D2843 2016 ASTM D635 2014 ASTM G155 2013 TAS 100(A) 1995 TAS 110 2000 Equivalence of Product Standards Certified By https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv%2bMluu6UrT%2boKMmB96zgssZWexXCYj%2bDD7igh8lLCBaw%3d%3d 1/3 1/28/22, 1:48 PM Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 12/30/2020 Date Validated 01/07/2021 Date Pending FBC Approval Date Approved 02/09/2021 Summary of Products FL# Model,Number or Name Description 36841.1 Highpoint@ Intake Intake Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL36841 RO C CAC 117C.6 Cert of Cert(HIGHPOINT Approved for use outside HVHZ:Yes INTAKE)_pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: +NA/-187.5 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II Highpoint Intake.pdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies roof pitches from 3:12 to 16:12 4)Shall not be installed on Created by Independent Third Party: roofs with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: 36841.2 Highpoint@ InvisaRidge'" Exhaust Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL36841 RO C CAC 117C.4 Cert of Cert(HIGHPOINT Approved for use outside HVHZ:Yes INVISARIDGE)_pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: +NA/-202.5 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II Highpoint Invisalkidge.pdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies minimum roof pitch of 3:12 4)Shall not be installed on roofs Created by Independent Third Party: with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: 36841.3 Highpoint® Performance Ridge Exhaust Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.7 Cert of Cert HIGHPOINT Approved for use outside HVHZ: Yes PERFORMANCE RIDGE)_pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II Highpoint Performance Ridge.pdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies roof pitches from 3:12 to 16:12 4)Shall not be installed on Created by Independent Third Party: roofs with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: 36841.4 Highpoint@ Performance Ridge XL Exhaust Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.5 Cert of Cert(HIGHPOINT Approved for use outside HVHZ:Yes PERFORMANCE RIDGE XL)-aft Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: N/A 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II Highpoint Performance Ridge.pdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies minimum roof pitch of 3:12 4)Shall not be installed on roofs Created by Independent Third Party: with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: 36841.5 Highpoint@ Stealth Ridge Exhaust Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.8 Cert of Cert HIGHPOINT Stealth Approved for use outside HVHZ:Yes Ridge)_pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: +NA/-172.5 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II Highpoint Stealth Ridge.pdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies minimum roof pitch of 3:12 4) Shall not be installed on roofs Created by Independent Third Party: with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv%2bMluu6UrT%2boKMmB96zgssZWexXCYj%2bDD7igh8lLCBaw%3d%3d 2/3 1/28/22, 1:48 PM Florida Building Code Online 36841.6 TruRidge@ Exhaust vent Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.1 Cert of Cert(TruRidge)_pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 11/05/2025 Design Pressure: +NA/-202.5 Installation Instructions Other: 1) Must be installed in accordance with the FL36841 RO II TruRidge.pdf manufacturer's installation instructions. 2)Approved to be Verified By: PRI Construction Materials Technologies installed over asphalt shingles 3)Approved to be installed on Created by Independent Third Party: roof pitches from 3:12 to 16:12 4)Shall not be installed on Evaluation Reports roofs with a mean roof height greater than 33 ft. Created by Independent Third Party: W000r Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.2 Cert of Cert(TruRidge All Approved for use outside HVHZ:Yes Weather)_pdf Impact Resistant: N/A Quality Assurance Contract Expiration Date Design Pressure: +NA/-202.5 11/05/2025 Other: 1) Must be installed in accordance with the Installation Instructions manufacturer's installation instructions. 2)Approved to be FL36841 RO II TruRidge All Weathenpdf installed over asphalt shingles 3)Approved to be installed on Verified By: PRI Construction Materials Technologies roof pitches from 3:12 to 16:12 4)Shall not be installed on Created by Independent Third Party: roofs with a mean roof height greater than 33 ft. Evaluation Reports Created by Independent Third Party: 36841.8 TruRidge@ Pro Exhaust Vent Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL36841 RO C CAC 117C.3 Cert of Cert(TruRidge Pro)_pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: N/A 11/05/2025 Design Pressure: N/A Installation Instructions Other: 1) Must be installed in accordance with the FL36841 RO II TruRidge Pro.pdf manufacturer's installation instructions. 2)Approved to be Verified By: PRI Construction Materials Technologies installed over asphalt shingles 3)Approved to be installed on Created by Independent Third Party: roof slopes from 3:12 to 16:12 4) Shall not be installed on Evaluation Reports roofs with a mean roof height greater than 33 ft. Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® OJ Kid 0 Credit Card Safe https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv%2bMiuu6UrT%2boKMmB96zgssZWexXCYj%2bDD7igh8lLCBaw%3d%3d 3/3 ■ VALIDATION `i PROGRAM Certificate No:117C.1 Expiration Date:Nov.5,2025 Manufacturer: ATLAS ROOFING CORPORATION Product Identification: TruRidge Exhaust Vent Manufacturing Location(s): 1448 Madison Ave. Grand Rapids, MI 49548 118 Celtic Circle, Madison, AL 35758 Product Type: Ridge Vent / Plastic Certified Standards: TAS 110(Table 14): TAS 100(A),ASTM D635,ASTM D1929,ASTM D2843,ASTM G155 ICC-ES AC132 ASTM E330*(design pressure -202.5 psf) *Design Pressure based on 2:1 safety factor CSI Division(s): 91.100, 91.120, 83.140 ICS Number Code(s): 07 72 26 Only products bearing the PRI-CMT Validation Program Mark will be considered as being included in good standing the Validation Program. Issued By: - Reviewed by: Brad Gc ybowski Brian Wilson PRI-CMT,LLC PRI-CMT,LLC Truffidge° ALL -WEATHER ���■ X Ridge Vent `-' - _410111 Classic Profile N FA sq.in.per ft. Fits 3/12 to 16/12 pitches tent Np 9540823 Features • 4'xl2" • Self-sealing ends • NFA: 18 • Exterior baffles and louvers for extreme • Exterior baffle product protection • Our specially formulated polymer creates a • Exceeds Department of Energy recommendations stronger product than competition and all nationally recognized building codes when • Raises the cap less than 1" installed properly • No connectors, straps or gaskets Options • TruRidge° All-Weather - with Filter & Nails �ft%Il Install the Complete System and Maximize the Coverage 0 Atlas WeatherMaster' O Atlas Roof Shingles _ Ice&Water Underlayment ATLAS ©Atlas TruRidge®&HighPoint° t® ©A —_ Signature Select Underlayment Exhaust VentilationROOFINGG SYSTEM ©Atlas Pro-Cut'Starter Shingles O Atlas StormMaster®&Pro-Cut' Hip&Ridge Shingles 'Refer to the Atlas Signature Select'Limited Warranty for all system coverage requirements. ' TruRidge° ALL-WEATHER Ridge Vent INSTALLATION INSTRUCTIONS Remove ridge cap shingles from the entire Snap chalk line on both sides of the ridge and no Cut along chalk lines.Remove roof sheathing. length of the ridge.Note:Delete Step 1 for new more than.750(3/4)of an inch from the peak. Note:Slot should not be cut any closer than construction. Note:If a ridgepole is present,cut a wider gap to within twelve(12)inches of gable end,hip allow a minimum of 1/2"air gap on both sides of intersecting ridge. the pole into the attic space-but do not remove more than 2-1/4"of roof sheathing material from either side of the ridge. k �+ 1 7Z For appearance(to blend with the roof line),it is Nail each additional section in the same manner Install new ridge cap in normal manner,using recommended that the TruRidge®vent be until entire ridge is covered.A chalk line may be 2-1/2"roofing nails,for 3/4"deck penetration installed the entire length of the ridge.Position the utilized to ensure vent alignment.Cut last piece to or penetration through the deck,whichever is first piece at one end of the ridge.Using 2-1/2" length and install with original uncut end to the less.Nailing the ridge caps through the vent nails,for 3/4"deck penetration or penetration outside. along the nailing line will secure the vent. through the deck,which ever is less,anchor vent Shingles may need to be trimmed. through preformed nail holes. f � • f 7 /-'J � � Ridge-to-ridge application requires a mitre-cut Ridge-to-roof application requires a mitre-cut to to maintain continuous ridge line appearance. maintain continuous ridge line appearance. Technical Specs 18 NFA sq. in. per ft. 48" PC LENGTH 12 CARTON/PALLET 44 LINEAR FEET/CARTON 11 PC/CARTON UNIFORM BUILDING CODES R806.2 Minimum area.The total net free ventilating area shall not be less than 1/150 of the area of the space ventilated except that the total area is permitted to be reduced to 1/300,provided at least 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. Upper ventilators shall be located not more than 3 feet(914 mm)below the ridge or highest point of space,measured vertically, with the balance of the required ventilation provided by the eave or cornice vents. See the published International Residential Code for additional information. Patent No. 9540823 e*8 Application and installation procedures are beyond the control of the seller or man- #AtlasProtects Atlas Roof ing.com ATLAS ufacturer.(Consequently,neither parry shall be responsible for failure of the product when not used in strict accordance to instructions and specifications.) ©Copyright 2021,Atlas Roofing Corporation ATL-215741-00 7/21