Loading...
HomeMy WebLinkAboutNOA - Architectural Shingles MIAMI-DADE COUNTY H PRODUCT CONTROL SECTION ,=ME I 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 www.miamidade.2ov/economy Atlas Roofing Corporation 2000 Riveredge Parkway, Suite 800 Atlanta, GA. 30328 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Pinnacle®Pristine, StormMasterO Shake and ProLam'm Architectural Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 17-0706.07 and consists of pages 1 through 8. The submitted documentation was reviewed by Freddy Semino NOA No.: 20-0527.05 AMDADE Cam , Expiration Date: 08/05/25 ®� Approval Date: 08/06/20 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Asphalt Shingles Materials: Laminate Deck Type: Wood 1. SCOPE This approves Pinnacle®Pristine, StormMaster®Shake and ProLam"Architectural Shingles manufactured by Atlas Roofing Corp., as described in Section 2 of this Notice of Acceptance, and designed to comply with the Florida Building Code,High Velocity Hurricane Zone. 2. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Pinnacle®Pristine, 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#1, 2, 3, 4 laminated asphalt shingle. Pinnacle®Pristine, 14"x 42" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#1, 2, 3, 4 laminated asphalt shingle. StormMaster®Shake 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#2 laminated asphalt shingle. StormMaster®Shake 14"x 42" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#2 laminated asphalt shingle. ProLamT"Architectural 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#1, 3, 4 laminated asphalt shingle. ProLamT"Architectural 14"x 42" TAS 110 A heavyweight, fiberglass reinforced, Manufacturing location#1, 3, 4 laminated asphalt shingle. 2.1. MANUFACTURING LOCATIONS 1. Hampton, GA 2. Dangerfield, TX 3. Meridian,MS 4. Franklin, OH NOA No.: 20-0527.05 AMDADE Cam , Expiration Date: 08/05/25 ®� Approval Date: 08/06/20 Page 2 of 8 3. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction Materials Technologies TAS 107 ATL-054-02-01 05/04/10 TAS 100 ATL-053-02-01 05/04/10 TAS 100 ATL-119-02-01 07/22/13 TAS 107 ATL-133-02-01 09/26/13 ASTM D 3462 ATL-136-02-01 10/14/13 TAS 100 ATL-107-02-01 12/12/13 TAS 107 ATL-143-02-01 11/01/13 ASTM D 3462 ATL-118-02-01 06/26/13 TAS 107 ATL-106-02-01 09/05/14 ASTM D 3462 ATL-104-02-01 04/21/13 ASTM D 3462 ATL-135-02-01 10/14/13 ASTM D 3462 ATL-116-02-01 06/26/13 TAS 107 ATL-132-02-01 09/26/13 TAS 100 ATL-125-02-01 07/22/13 TAS 107 ATL-144-02-01 11/01/13 ASTM D 3462 ATL-220-02-01 10/12/17 TAS 100 ATL-220-02-02.1 10/12/17 TAS 107 ATL-220-02-03 10/12/17 ASTM D 3462 ATL-221-02-01 10/12/17 TAS 100 ATL-221-02-02.1 10/12/17 TAS 107 ATL-221-02-03 10/12/17 ASTM D 3462 ATL-222-02-01 10/12/17 TAS 100 ATL-222-02-02 10/12/17 TAS 107 ATL-222-02-03 10/12/17 ASTM D 3462 ATL-223-02-01 10/12/17 TAS 100 ATL-223-02-02.1 10/12/17 TAS 107 ATL-223-02-03 10/12/17 ASTM D 3462 ATL-224-02-01 10/12/17 Underwriters Laboratories,Inc. UL 790 11CA51478 02/01/12 NOA No.: 20-0527.05 ��,DADE C Expiration Date: 08/05/25 NTYM Approval Date: 08/06/20 Page 3 of 8 4. LIMITATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 5. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail `A',attached. 5. 42-inch Pinnacle TM Pristine 6-inch offset layout shall be in compliance with Detail `B', attached. 6. 42-inch ProLamTM Architectural 6-inch offset layout shall be in compliance with Detail `C', attached. 7. Pinnacle PristineTM Laminate sealant pattern shall be in compliance with Detail `E', attached. 8. ProLam 42 Laminate sealant pattern shall be in compliance with Detail `D', attached. 9. Nailing shall be in compliance with Detail'F'and Detail `G', attached. 6. LABELING Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control Seal as seen below: MIAMI-DADE COUNTY 7. BUILDING PERMIT REQUIREMENTS Application for a building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 20-0527.05 AMDADE Cam , Expiration Date: 08/05/25 ®� Approval Date: 08/06/20 Page 4 of 8 E �g0LA� ASTER A ii li lit liti it li li life I iililil III111111111 it i11 ii II Illil ii ilili i 11 11 ,i ii II11 III ii 111111 it iilil ii i,i 11111 it Ifni it 1 111 it II it 11 ill liil Iilil II II III II IItili i ii li lllilili ililililil ii li, it it it il1111111 it ilili iiiiii IIIIii 1111 11 ii 111111 Iillili lil1111 Ill illl iililili ilili 11 Iliili tli ii ll111 it ill i lililil it 11 lil 111II lil it it ill fill it 11 11 li 111 i IIIIIII II ii lit it ii li li 11,11 ii Iilii lilt lilt ii 1l li,i lil 11 i 11111II ii IIfIi flit 111( I II111111111 ii1 it i11111{ili 111111 Iilii ii iilil iii II II II111 fill Ilil ii ii 11 lilll Iilili it ii li 111111 li I1111111 111111 Ill FUG U S SiA`GpURsf iiiiii,flll f0UR /! fill lilllil ii 11 it ii 11 ll11,11 i1 ill 11 lililii ii Ii lil 11 it it ii 11 Ill iifiii 111111 it illl ll1111 i 111 ii 1i 1111111 i II II IiI 1111111111 IIIIii GpURSE F,Rs4 SN�NG�E pUA-t. 10' R`3E S1Rp cpU tR`M 5., cpURSE sec,00 Z0,05L1 05 ONNo•� 0g1051,15 u 0612 �XpfJ 1Catio fDa;OS) 5 of$ Nov 4Ate, DETAIL `B' f Zero Wa$t*, 6" Offset -oderla1-oaeut 4 J'L�L 1Ty.i•L 1L.i'L.Ji aL�L "Cat From Course 2 12" Cut From Course 3 19" Cut Fram Cause 4 -A. r— A% 1 or GA 4" Cut Shingle 121cut o"Cut Shingle A'f�tl A 1s 1 b" Cut Shingle Fu14r u1142" Shingle 4211 PINNACLE PRISTINE TM 6" OFFSET DETAIL `C' Zero Waste, 6" Met na�l�ym�t " Cut From Course 2 I yt� 12 Cut From Course 3 18" Cut From Course 4 Ur cm-1-11 "Cot Shingle ii 12`G1f " Cut Shingle * _ " Gott Shingle R IrIbbigh 7 . u1142" Shingle NOA No.: 20-0527.05 AMDADE Cam , Expiration Date: 08/05/25 ®� Approval Date: 08/06/20 Page 6 of 8 42" PRoLAMfm ARCHITECTURAL 611 OFFSET DETAIL ID1 42" TOP: Y4'- SEALANT LINE PATTERN TOPL 1 LENGTH ON: 3- OFF B BoT ro oTrom I" LENGTH 014; 1" OFF ----------- 06� a WNW.- 4=0-- mlw� dilm- =111- MEW- qmml- - 4 qqW-- HALING MFA PINNACLE TM PRISTINE 421" LAMINATE SEALANT PATTERN DETAIL 'E' 4-2 SINGLE 4" SEALANT LINE PATLERN 1" LENGTH ON I- OFF - - - - - - - - - - - - - - - - - - - - - - - - - - - ! - =�--1 �--� --4m---mW e: �-Tl'*NAIU14G ME NOA No.: 20-0527.05 WMAMDADE Cam hon Expiration Date: 08/05/25 Approval Date: 08/06/20 Page 7 of 8 PROLAM ARCHITECTURALTM 42"LAMINATE SEALANT PATTERN DETAIL `F' 39 3/$„ — I APPROVED FASTENER 1" — 7 '/" 1 2 0000t- � co o � QC� 14" CD � � oo � moo o � o [::D I 6" 6 7/a" L I . ./ DETAIL `G' 42" APPROVED FASTENER 1" 7 ,�2„ 1" moo C3 � G� CD C3 r c� o � CDCDCGCD 14" ov ooC3 CM M o Cn � =1 T- 6 /a 6" END OF THIS ACCEPTANCE NOA No.: 20-0527.05 M1AMI-DADS CQY Expiration Date: 08/05/25 Approval Date: 08/06/20 Page 8 of 8