HomeMy WebLinkAboutNOA - Architectural Shingles MIAMI-DADE COUNTY
H PRODUCT CONTROL SECTION
,=ME I 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
www.miamidade.2ov/economy
Atlas Roofing Corporation
2000 Riveredge Parkway, Suite 800
Atlanta, GA. 30328
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section(In
Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by
Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Pinnacle®Pristine, StormMasterO Shake and ProLam'm Architectural Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 17-0706.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 20-0527.05
AMDADE Cam , Expiration Date: 08/05/25
®� Approval Date: 08/06/20
Page 1 of 8
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
1. SCOPE
This approves Pinnacle®Pristine, StormMaster®Shake and ProLam"Architectural Shingles manufactured by
Atlas Roofing Corp., as described in Section 2 of this Notice of Acceptance, and designed to comply with the Florida
Building Code,High Velocity Hurricane Zone.
2. PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Pinnacle®Pristine, 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#1, 2, 3, 4 laminated asphalt shingle.
Pinnacle®Pristine, 14"x 42" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#1, 2, 3, 4 laminated asphalt shingle.
StormMaster®Shake 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#2 laminated asphalt shingle.
StormMaster®Shake 14"x 42" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#2 laminated asphalt shingle.
ProLamT"Architectural 14"x 39 3/8" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#1, 3, 4 laminated asphalt shingle.
ProLamT"Architectural 14"x 42" TAS 110 A heavyweight, fiberglass reinforced,
Manufacturing location#1, 3, 4 laminated asphalt shingle.
2.1. MANUFACTURING LOCATIONS
1. Hampton, GA
2. Dangerfield, TX
3. Meridian,MS
4. Franklin, OH
NOA No.: 20-0527.05
AMDADE Cam , Expiration Date: 08/05/25
®� Approval Date: 08/06/20
Page 2 of 8
3. EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials Technologies
TAS 107 ATL-054-02-01 05/04/10
TAS 100 ATL-053-02-01 05/04/10
TAS 100 ATL-119-02-01 07/22/13
TAS 107 ATL-133-02-01 09/26/13
ASTM D 3462 ATL-136-02-01 10/14/13
TAS 100 ATL-107-02-01 12/12/13
TAS 107 ATL-143-02-01 11/01/13
ASTM D 3462 ATL-118-02-01 06/26/13
TAS 107 ATL-106-02-01 09/05/14
ASTM D 3462 ATL-104-02-01 04/21/13
ASTM D 3462 ATL-135-02-01 10/14/13
ASTM D 3462 ATL-116-02-01 06/26/13
TAS 107 ATL-132-02-01 09/26/13
TAS 100 ATL-125-02-01 07/22/13
TAS 107 ATL-144-02-01 11/01/13
ASTM D 3462 ATL-220-02-01 10/12/17
TAS 100 ATL-220-02-02.1 10/12/17
TAS 107 ATL-220-02-03 10/12/17
ASTM D 3462 ATL-221-02-01 10/12/17
TAS 100 ATL-221-02-02.1 10/12/17
TAS 107 ATL-221-02-03 10/12/17
ASTM D 3462 ATL-222-02-01 10/12/17
TAS 100 ATL-222-02-02 10/12/17
TAS 107 ATL-222-02-03 10/12/17
ASTM D 3462 ATL-223-02-01 10/12/17
TAS 100 ATL-223-02-02.1 10/12/17
TAS 107 ATL-223-02-03 10/12/17
ASTM D 3462 ATL-224-02-01 10/12/17
Underwriters Laboratories,Inc. UL 790 11CA51478 02/01/12
NOA No.: 20-0527.05
��,DADE C Expiration Date: 08/05/25
NTYM Approval Date: 08/06/20
Page 3 of 8
4. LIMITATIONS
1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
5. INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail `A',attached.
5. 42-inch Pinnacle TM Pristine 6-inch offset layout shall be in compliance with Detail `B', attached.
6. 42-inch ProLamTM Architectural 6-inch offset layout shall be in compliance with Detail `C', attached.
7. Pinnacle PristineTM Laminate sealant pattern shall be in compliance with Detail `E', attached.
8. ProLam 42 Laminate sealant pattern shall be in compliance with Detail `D', attached.
9. Nailing shall be in compliance with Detail'F'and Detail `G', attached.
6. LABELING
Shingles shall be permanently labeled with the manufacturer's name and/or logo, city and state of manufacturing
facility, and the following statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade
County Product Control Seal as seen below:
MIAMI-DADE COUNTY
7. BUILDING PERMIT REQUIREMENTS
Application for a building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or the applicable code in order to properly evaluate the
installation of this system.
NOA No.: 20-0527.05
AMDADE Cam , Expiration Date: 08/05/25
®� Approval Date: 08/06/20
Page 4 of 8
E
�g0LA�
ASTER A
ii li lit
liti it li li life
I iililil III111111111
it i11 ii II Illil ii ilili
i 11 11 ,i ii II11 III
ii 111111 it iilil
ii i,i 11111 it
Ifni it
1 111
it
II it 11 ill liil
Iilil II II III II IItili
i ii li lllilili ililililil ii li,
it it it il1111111 it ilili iiiiii
IIIIii 1111 11 ii 111111 Iillili lil1111
Ill illl iililili ilili 11 Iliili tli ii ll111 it ill
i lililil it 11 lil 111II lil it it ill fill it 11 11 li 111
i IIIIIII II ii lit it ii li li 11,11 ii Iilii lilt lilt
ii 1l li,i lil 11 i 11111II ii IIfIi flit 111(
I II111111111 ii1 it i11111{ili 111111
Iilii ii iilil iii II II II111 fill
Ilil ii ii 11 lilll Iilili
it ii li 111111 li
I1111111
111111
Ill
FUG U S SiA`GpURsf iiiiii,flll
f0UR
/! fill lilllil ii 11 it ii 11 ll11,11 i1
ill 11 lililii ii Ii lil 11 it it ii 11
Ill iifiii 111111 it illl ll1111
i 111 ii 1i 1111111 i II II IiI
1111111111 IIIIii
GpURSE
F,Rs4 SN�NG�E
pUA-t.
10' R`3E
S1Rp cpU tR`M 5., cpURSE
sec,00
Z0,05L1 05
ONNo•� 0g1051,15
u 0612
�XpfJ
1Catio fDa;OS) 5 of$
Nov 4Ate,
DETAIL `B'
f
Zero Wa$t*, 6" Offset
-oderla1-oaeut
4 J'L�L 1Ty.i•L 1L.i'L.Ji aL�L
"Cat From Course 2
12" Cut From Course 3
19" Cut Fram Cause 4
-A. r— A%
1 or GA 4" Cut Shingle
121cut o"Cut Shingle
A'f�tl
A 1s 1 b" Cut Shingle
Fu14r u1142" Shingle
4211 PINNACLE PRISTINE TM 6" OFFSET
DETAIL `C'
Zero Waste, 6" Met
na�l�ym�t
" Cut From Course 2
I
yt� 12 Cut From Course 3
18" Cut From Course 4
Ur cm-1-11 "Cot Shingle
ii
12`G1f " Cut Shingle
* _ " Gott Shingle
R IrIbbigh 7 .
u1142" Shingle
NOA No.: 20-0527.05
AMDADE Cam , Expiration Date: 08/05/25
®� Approval Date: 08/06/20
Page 6 of 8
42" PRoLAMfm ARCHITECTURAL 611 OFFSET
DETAIL ID1
42"
TOP:
Y4'- SEALANT LINE PATTERN
TOPL 1 LENGTH ON: 3- OFF
B BoT ro
oTrom I" LENGTH 014; 1" OFF
-----------
06� a
WNW.- 4=0-- mlw� dilm- =111- MEW-
qmml- - 4 qqW--
HALING MFA
PINNACLE TM PRISTINE 421" LAMINATE SEALANT PATTERN
DETAIL 'E'
4-2
SINGLE 4" SEALANT LINE PATLERN
1" LENGTH ON I- OFF
- - - - - - - - - - - - - - - - - - - - - - - - - - -
! -
=�--1 �--� --4m---mW
e: �-Tl'*NAIU14G ME
NOA No.: 20-0527.05
WMAMDADE Cam hon Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 7 of 8
PROLAM ARCHITECTURALTM 42"LAMINATE SEALANT PATTERN
DETAIL `F'
39 3/$„ — I
APPROVED FASTENER
1" —
7 '/" 1 2
0000t- � co o � QC� 14"
CD � � oo � moo o � o [::D I
6" 6 7/a"
L I . ./
DETAIL `G'
42"
APPROVED FASTENER
1" 7 ,�2„ 1"
moo C3 � G� CD C3 r c� o � CDCDCGCD 14"
ov ooC3 CM M o Cn � =1
T-
6 /a
6"
END OF THIS ACCEPTANCE
NOA No.: 20-0527.05
M1AMI-DADS CQY Expiration Date: 08/05/25
Approval Date: 08/06/20
Page 8 of 8