Loading...
HomeMy WebLinkAbout56-SF-2204952 FINAL FINALSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL 30 W"IL I APPLICANT: Phil and Karen Episcopo AGENT: Pace 2000, Inc PROPERTY ADDRESS: 4953 Bald Cypress Trl Fort Pierce, FL 34951 LOT: BLOCK: APPLICATION #:AP1601196 PERMIT #:56-SF-2204952 DOCUMENT #:F11785159 DATE PAID:02/14/2022 FEE PAID:95.00 RECEIPT #:56-PID-5454981 SUBDIVISION: ID # : 1418-132-0005-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [21 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 90 FT [ ] [031 OUTLET DEVICE [ ] [29] PRIVATE WELLS 83 FT [ ] [041 MULTI -CHAMBERED [ Y k N ] [ ] (301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. [ ] [321 POTABLE WATER 25 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 10 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 20 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 384 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1, 3.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 02/09/2022 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 21.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR Jeff Nelson (Jeffrey Nelson Se [ ] [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 EQ36 (single c [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / / tCle CHD DATE: 11/19/2021 DISAPPROVED 1. Environmental Specialist III Bria In X am (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD DATE: 02/17/2022 ERVironmentfifSpecialist I atthe aja a Florida Department of H (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1601195 EID2204952 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1601195 PERMIT #:56-SF-2204952 DOCUMENT #:F11785159 DATE PAID : 02/14/2022 FEE PAID:95.00 RECEIPT #:56-PID-5454981 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 New ST, filter, and 2x11+1x10 TRENCH DF installed. No violations, system ok to cover, contractor notified onsite. Needs final inspection for depth of cover, mound system, and final site grading. Final inspection conducted. Mound system checked, depth of cover checked. Violations observed. System mound shoulder S of system did not meet 4ft shoulder requirement. Contractor notified by phone. Re -inspection required. Final re -inspection completed. Shoulders checked and final site grading completed. Final inspection approved. Emailed copy to building department and contractor DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1601195 EID2204952