HomeMy WebLinkAboutAPPROVED MORRIS, HAROLD - SOLAR PV PLANS 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Jon P. Ward, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com January 25, 2022 Modern Concepts Solar SunTrust Tower 401 E. Jackson Street Suite 3300 Tampa, FL 33602 Re: Engineering Services Morris Residence 9168 Pumpkin Ridge, Port St. Lucie, FL 22.880 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: Assumed prefabricated wood trusses at 24” on center. All truss members are constructed of 2x4 dimensional lumber. Roof Material: Tile Shingles Roof Slope: 30 degrees Attic Access: Inaccessible Lumber type: Assumed Douglas Fir Foundation: Permanent C. Loading Criteria Used  Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF  Load  Live Load = 20 psf (reducible) – 0 psf at locations of solar panels  Ground Snow Load = 0 psf  Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 140 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the FBC 2020 (7th Edition) including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent K-2 Systems installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a 5/16” lag screw is 235 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2½”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5/16” diameter lag screw with a minimum of 2½” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48” on centers. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the FBC 2020 (7th Edition), current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE Florida License No. 81558 PROJECT DATAGENERAL NOTESVICINITY MAPSHEET INDEXCODE REFERENCESPROJECTADDRESS9168 PUMPKIN RIDGE,PORT ST. LUCIE, FL 34986OWNER:HAROLD MORRISSCOPE:HOUSE PHOTOPHOTOVOLTAIC ROOF MOUNT SYSTEM52 MODULES-ROOF MOUNTED - 22.880 KW DC, 15.080 KW AC9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986PV-1COVER SHEETPV-2SITE PLANPV-3ROOF PLAN & MODULESPV-4ELECTRICAL PLANPV-5 STRUCTURAL DETAILPV-6ELECTRICAL LINE DIAGRAMPV-7WIRING CALCULATIONSPV-8LABELSPV-9PLACARDPV-10 MICRO INVERTER CHARTPV-11+ EQUIPMENT SPECIFICATIONSAUTHORITIES HAVING JURISDICTION:BUILDING: ST. LUCIE COUNTYZONING: ST. LUCIE COUNTYUTILITY: FPLDESIGNER:ESRREVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARPV-1COVER SHEETSIGNATURE1.ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED.2.THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE WITH ARTICLE 690 OF THE NEC 2017.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLELOPERATION.4.ALL CONDUCTORS OF A CIRCUIT, INCLUDING THE EGC, MUST BE INSTALLED IN THE SAME RACEWAY, OR CABLE, OROTHERWISE RUN WITH THE PV ARRAY CIRCUIT CONDUCTORS WHEN THEY LEAVE THE VICINITY OF THE PV ARRAY.5.WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS"CAUTION: SOLAR CIRCUIT" EVERY 10FT.6.HEIGHT OF THE AC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24.7.A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BEPROVIDED. PER NEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICEENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USEDAT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODECONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE EXISTINGGROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM.8.PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE.9.PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS.10.ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE.WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF THE ROOF SURFACE.11.ALL SINAGE TO BE PLACED IN ACCORDANCE WITH THE LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UVRESISTANT. ALL PLAQUES AND SINAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ.12.INVERTER(S) USED IN UNGROUNDED SYSTEM SHALL BE UL 1741 LISTED.13.THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE PERFORMED ONLY BYQUALIFIED PERSONS [NEC 690.4(C)]14.ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED (OR BETTER), INCLUDING ALL ROOF MOUNTED TRANSITION BOXES ANDSWITCHES.15.ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250.16.SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41.17.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN ACCORDANCE WITHNEC 690.1218.DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE PV SYSTEMEQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(A)]19.ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.3120.WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), 110.26(A)(2) AND 110.26(A)(3).21.ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED & IDENTIFIED IN ACCORDANCE WITHUL170322.ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS REQUIRED PER NEC.22.880 KW DC ROOF MOUNTSOLAR PV SYSTEM WITH52 APTOS SOLAR: DNA-144-MF26 440WPV MODULES WITH52 ENPHASE IQ7PLUS-72-2-US 290WMICROINVERTERS EQUIPPED WITHRAPID SHUTDOWNPROJECT TO COMPLY WITH THE FOLLOWING:FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 EDITION (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)2017 NATIONAL ELECTRICAL CODEFLORIDA FIRE PREVENTION CODE, 7TH EDITION (FFPC) 135.00' 135.00'57.00'57.00'MSP UM CBACD SUB1SITE PLANSCALE: 1/16" = 1'-0"PV-2REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARPROJECT DESCRIPTION:SITE PLANDESIGN SPECIFICATIONOCCUPANCY: IICONSTRUCTION: SINGLE-FAMILYZONING: RESIDENTIALGROUND SNOW LOAD: REFER STRUCTURAL LETTERWIND EXPOSURE: REFER STRUCTURAL LETTERWIND SPEED: REFER STRUCTURAL LETTERNOTE: VISIBLE, LOCKABLE, LABELED AC DISCONNECTLOCATED WITHIN 10' OF UTILITY METER52 X APTOS SOLAR: DNA-144-MF26 440W MONO MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESDC SYSTEM SIZE: 52 x 440 = 22.880KW DCAC SYSTEM SIZE: 52 x 290 = 15.080KW ACPV-2(N) VISIBLE, LOCKABLE,LABELED FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(N) ENPHASE COMBINER BOX(E) TREESEQUIPMENT SUMMARY52 APTOS SOLAR: DNA-144-MF26 440W MONO MODULES52 ENPHASE IQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNROOF ARRAY AREA #1:- 1007.49 SQ FT.ROOF ARRAY AREA #2:- 93.72 SQ FT.ROOF ARRAY AREA #3:- 117.15 SQ FT.PROPERTY LINEPROPERTY LINEPROPERTY LINEPROPERTY LINEPUMPKIN RIDGEEXISTINGDRIVEWAY1-STORYHOUSEROOF #1(43) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNROOF #3(5) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNROOF #2(4) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWN(E) POOL(E) SHED(E) UTILITY METER/MAIN COMBO(E) SUBPANEL (INSIDE GARAGE)NOTE: DESIGNED FOR INSTALLATION OF GRID-TIEDPHOTOVOLTAIC SOLAR SYSTEM. 51'-0"13'-9" 85'-3" 67'-3"28'-10"13'-9"4'-0"MSP UM SUB MODULE TYPE, DIMENSIONS & WEIGHT1ROOF PLAN & MODULESPV-3SCALE: 3/32" = 1'-0"ROOF PLAN &MODULESNUMBER OF MODULES = 52 MODULESMODULE TYPE = APTOS SOLAR: DNA-144-MF26 440W MONO MODULESMODULE WEIGHT = 53.13 LBS / 24.1KG.MODULE DIMENSIONS = 82.48" x 40.91" = 23.43 SFAPTOS SOLAR:DNA-144-MF26440W MODULES82.48"40.91"LEGEND- JUNCTION BOXJBINVUMMSPSLD- INVERTER- SOLAR LOAD CENTER- UTILITY METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- ROOF ATTACHMENT- TRUSS- CONDUITACD- AC DISCONNECT- COMBINER BOXCB- SOLADECKPMSD- PV PRODUCTION METERPV-3REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARARRAY AREA & ROOF AREA CALC'STOTAL PV ARRAYAREA(SQ. FT.)TOTAL ROOFAREA(Sq. Ft.)ROOFAREA COVERED BYARRAY (%)1218.363425.1536(N) EVEREST K2 SYSTEMS CROSSRAIL 44-X(105) IRONRIDGE KNOCKOUTTILE ATTACHMENTROOF #1(43) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNROOF #3(5) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNROOF #2(4) APTOS SOLAR: DNA-144-MF26440W MONO MODULES WITH ENPHASEIQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWN(E) UTILITY METER/MAIN COMBO(E) SUBPANEL (INSIDE GARAGE)1 8 " F IR E SE TB ACK 1 8 " F IRE S E TB ACK 36" FIRE SETBACK 36" FIRE SETBACK 36" FIRE SETBACK36" FIRE SETBACK18" FIRE SETBACK18" FIRE SETBA C K 36" FIRE SETBACK 18" FIRE SETBACK18" FIRE SETBACK3 6 " F IRE S E TB ACK ROOF DESCRIPTIONROOF TYPEW-TILEROOF# OFMODULESROOFPITCHAZIMUTHTRUSSSIZETRUSSSPACING#14330°92°2"X4"24"#2430°272°2"X4"24"#3530°182°2"X4"24"ROOF #1PITCH - 30°AZIM. - 92°ROOF #3PITCH - 30°AZIM. - 182°ROOF #2PITCH - 30°AZIM. - 272° MSP UM CBACDJBJBJBSUB1ELECTRICAL PLANPV-4SCALE: 3/32" = 1'-0"ELECTRICAL PLANREVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARCIRCUIT #1CIRCUIT LEGENDSLEGEND- SOLADECKSDINVUMMSP- INVERTER- UTILITY METER- MAIN SERVICE PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- ROOF ATTACHMENT- RAFTER- CONDUITACD- AC DISCONNECT- COMBINER BOXCB- JUNCTION BOXJBCIRCUIT #2DC SYSTEM SIZE: 52 x 440 = 22.880KW DCAC SYSTEM SIZE: 52 x 290 = 15.080KW AC(52) APTOS SOLAR: DNA-144-MF26 440W MONO MODULESWITH (52) ENPHASE IQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNLOCATED UNDER EACH PANEL (240V)PV-4(N) CONDUIT(N) JUNCTION BOX (TYP.)CIRCUIT #1(13 MODULES)CIRCUIT #2(13 MODULES)BILL OF MATERIALSEQUIPMENTQTYDESCRIPTIONSOLAR PV MODULES52APTOS SOLAR: DNA-144-MF26 440W MODULEMICRO INVERTERS52ENPHASE IQ7PLUS-72-2-US 290WMICROINVERTERS EQUIPPED WITH RAPIDSHUTDOWNJUNCTION BOXES36"X6"X4" UL LISTED, STEEL WATERTIGHT NEMA TYPE 3R, UL LISTEDCOMBINER BOX1ENPHASE X-IQ-AM1-240-3AC COMBINER BOX, 120/240VAC, 1ɸ, 3W125A RATED BUS BAR, NEMA 3RBREAKERS420A BREAKERSAC DISCONNECT1FUSED AC DISCONNECT, 100A FUSED,(2) 80A FUSES 240V NEMA 3R, UL LISTEDRAIL29EVEREST K2 SYSTEMS CROSSRAIL 44-X 166"SPLICE18SPLICE KITMID MODULE CLAMPS90MID MODULE CLAMPSEND CLAMPS28END CLAMPS / STOPPER SLEEVEGROUNDING LUG7GROUNDING LUGATTACHMENTS105IRONRIDGE KNOCKOUT TILE ATTACHMENTCIRCUIT #3CIRCUIT #4(N) VISIBLE, LOCKABLE,LABELED FUSED AC DISCONNECT(LOCATED WITHIN 10' OF UTILITY METER)(N) ENPHASE COMBINER BOXPUMPKIN RIDGE(E) UTILITY METER/MAIN COMBO(E) SUBPANEL (INSIDE GARAGE)(52) ENPHASE IQ7PLUS-72-2-US290W MICROINVERTERS EQUIPPEDWITH RAPID SHUTDOWNCIRCUIT #3(13 MODULES)CIRCUIT #4(13 MODULES) REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARSTRUCTURAL DETAILPV-56"ATTACHMENT DETAIL (enlarged view)21STRUCTURAL ATTACMENT (SIDE VIEW)SCALE: N.T.SSCALE: N.T.SPV-5PV-5SEE (2/PV-5) FORENLARGED VIEWPV MODULE(E) W-TILE ROOFCHANNEL NUTPV MODULEGROUNDINGEND/MID CLAMPEVEREST K2 SYSTEMSCROSSRAIL 44-X(E) W-TILE ROOF2"X4" TRUSS @ 24" O.C.NUT, FLANGE 5/16-18 SSTASSY, PEDESTAL 1L-FOOTLAG SCREW, 5/16X42"X4" TRUSS @ 24" O.C. L1L2G-+-+2-+13=12====BRANCHTERMINATOR(ET-TERM)GN-+-+2-+13=====-+-+2-+13=====BRANCH #2BRANCH #3BRANCH #4L1L2L1L2L1L2-+-+2-+13=====BRANCH #1JUNCTION BOX,600V, NEMA 3R,UL LISTEDENPHASE X-IQ-AM1-240-3AC COMBINER BOX120/240VAC, 1ɸ, 3W125A RATED BUS BAR, NEMA 3RSOLAR LOADS ONLYUL 1741 COMPLIANT20A/2P20A/2P20A/2P20A/2P121312131213121315A/2PIQ ENVOYAPTOS SOLAR: DNA-144-MF26440W MODULESENPHASE IQ7PLUS-72-2-US 290WMICROINVERTERS EQUIPPED WITHRAPID SHUTDOWNLOCATED UNDER EACH PANEL (240V)IQ ENVOY : PERMANUFACTURERSPECIFICATIONS, EITHER10A OR 15A BREAKER ISSUITABLE FOR USELOADLINEGL1L2NG3NVISIBLE, LOCKABLE,LABELED AC DISCONNECTLOCATED WITHIN 10'OF UTILITY METER80AFusesPV FUSED ACDISCONNECT240V, 1ɸ, 3W100A RATEDNEMA 3RLOAD/LINE SIDEINTERCONNECTIONAT MAIN PANELPER ART. 705.12L1L2NNL2L1MTO UTILITY GRID4(E)150A/2P(E) SUB PANEL,SQUARE D,200A RATED, 240VGNGN(E) MAIN BREAKER TOHOUSE 240 V, 150A/2P(E) MAIN SERVICEPANEL,200A RATED, 240VEXISTING GROUNDINGELECTRODE SYSTEM TO EARTHREF. NEC 250.52, 250.53(A)BI-DIRECTIONALUTILITY METER120/240V 1ɸ, 3-W(N) MAIN BREAKER240V, 200A/2PFAR END FEEDER CONNECTIONREF2017 NEC 705.12(B)(2)(1)(a) / 705.12(B)(2)(1)(b)2014 NEC 705.12(D)(2)(1)(a) / 705.12(D)(2)(1)(b)GEC(N) #6 BARE CU VIAIRREVERSIBLE CRIMP TOEXISTING GROUNDINGELECTRODE SYSTEMREVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARELECTRICAL LINE DIAGRAM1ELECTRICAL LINE DIAGRAMPV-6SCALE: NTSPV-6DC SYSTEM SIZE: 52 x 440 = 22.880KW DCAC SYSTEM SIZE: 52 x 290 = 15.080KW AC(52) APTOS SOLAR: DNA-144-MF26 440W MONO MODULESWITH (52) ENPHASE IQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNLOCATED UNDER EACH PANEL (240V)(4) BRANCH CIRCUITS OF 13 MODULES CONNECTED IN PARALLELINTERCONNECTION NOTES:1. INTERCONNECTION SIZING, LIMITATIONS AND COMPLIANCEDETERMINED IN ACCORDANCE WITH [NEC 705.12], AND [NEC 690.59].2. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9],[NEC 230.95].3. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING.4. PV BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THEBUSBAR RELATIVE TO THE MAIN BREAKER.DISCONNECT NOTES:1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHENTHE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARECONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLYTHE UPPER TERMINALS)2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITYPERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH3. DISCONNECT MEANS AND THEIR LOCATION SHALL BE INACCORDANCE WITH [NEC 225.31] AND [NEC 225.32].GROUNDING & GENERAL NOTES:1. PV GROUNDING ELECTRODE SYSTEM NEEDS TO BE INSTALLED IN ACCORDANCEWITH [NEC 690.43]2. PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE.3. DC GEC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTINGELECTRODE4. ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT ISFOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINALINSPECTION.5. SOLADECK QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THEFIELD - SOLADECK DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRETYPE TRANSITIONS.6. AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHERAC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT.7. RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS SHOULD BEINSTALLED MORE THAN 7/8" ABOVE THE ROOF USING CONDUIT SUPPORTS.QTYCONDUCTOR INFORMATIONCONDUIT TYPECONDUITSIZE(8)#12AWG -ENPHASE ENGAGE CABLE(L1 & L2 NO NEUTRAL)N/AN/A(1)#6AWG -BARE COPPER IN FREE AIR(8)#10AWG -CU,THWN-2EMT OR LFMC IN ATTIC3/4"(1)#10AWG -CU,THWN-2 GND(2)#4AWG -CU,THWN-2EMT, LFMC OR PVC(1)#4AWG -CU,THWN-2 N(1)#6AWG -CU,THWN-2 GND(2)#4AWG -CU,THWN-2EMT, LFMC OR PVC(1)#4AWG -CU,THWN-2 N12341"1"RACKING NOTE:1.BOND EVERY RAIL WITH #6 BARE COPPER REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARWIRING CALCULATIONSPV-7PERCENT OFVALUESNUMBER OF CURRENTCARRYING CONDUCTORS IN EMT.804-6.707-9.5010-20SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL #APTOS SOLAR: DNA-144-MF26 440W MODULE VMP41.0V IMP10.74A VOC49.9V ISC11.33A TEMP. COEFF. VOC-0.29%/°C MODULE DIMENSION82.48"L x 40.91"W x 1.57"D (In Inch)INVERTER SPECIFICATIONSMANUFACTURER / MODEL #ENPHASE IQ7PLUS-72-2-US 290W MICROINVERTERSEQUIPPED WITH RAPID SHUTDOWNMIN/MAX DC VOLT RATING22V MIN/ 60V MAXMAX INPUT POWER235W-440WNOMINAL AC VOLTAGE RATING240V/ 211-264VMAX AC CURRENT1.21AMAX MODULES PER CIRCUIT13 (SINGLE PHASE)MAX OUTPUT POWER290 VAAMBIENT TEMPERATURE SPECSRECORD LOW TEMP0AMBIENT TEMP (HIGH TEMP 2%)33°MODULE TEMPERATURE COEFFICIENT OF Voc-0.29%/°CELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT.3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS.6.WHERE SIZES OF SOLADECK, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE.8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.10.TEMPERATURE RATINGS OF ALL CONDUCTORS, TERMINATIONS, BREAKERS, OR OTHER DEVICES ASSOCIATED WITH THESOLAR PV SYSTEM SHALL BE RATED FOR AT LEAST 75 DEGREE C. REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARLABELSPV-8** ELECTRICAL DIAGRAM SHOWN IS FORLABELING PURPOSES ONLY. NOT AN ACTUALREPRESENATION OF EQUIPMENT ANDCONNECTIONS TO BE INSTALLED. LABELLOCATIONS PRESENTED MAY VERYDEPENDING ON TYPE OF INTERCONNECTIONMETHOD AND LOCATION PRESENTEDELECTRICAL DIAGRAM PAGE. **NOTE:MCOMBINERARRAY ACD234101278924MSP /SUBPANELMSDSOLADECK / JUNCTION BOX 241110LABEL-1:CAUTION:AUTHORIZED SOLARPERSONNEL ONLY!NOTE:LABEL LOCATION:AC DISCONNECTWARNING!TERMINALS ON THE LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITIONELECTRICAL SHOCK HAZARDLABEL LOCATION:AC DISCONNECTCOMBINERMAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCODE REF: NEC 690.13(B)LABEL- 2:!WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMLABEL LOCATION:UTILITY METERMAIN SERVICE PANELSUBPANELCODE REF: NEC 705.12(C) & NEC 690.59LABEL- 3:TURN OFF PHOTOVOLTAIC ACDISCONNECT PRIOR TOWORKING INSIDE PANELWARNING!LABEL LOCATION:MAIN SERVICE PANELSUBPANELMAIN SERVICE DISCONNECTCOMBINERCODE REF: NEC 110.27(C) & OSHA 1910.145 (f) (7)LABEL- 4:LABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3-4) & NEC 690.59LABEL- 5:CAUTION!PHOTOVOLTAIC SYSTEM CIRCUIT ISBACKFEEDLABEL LOCATION:MAIN SERVICE PANEL (ONLY IF SOLAR IS BACK-FED)SUBPANEL (ONLY IF SOLAR IS BACK-FED)CODE REF: NEC 705.12(B)(3)(2)LABEL- 6:SOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNTURN RAPID SHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECTCODE REF: IFC 605.11.3.1(1) & NEC 690.56(C)LABEL- 7:RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.56(C)(2)LABEL- 8:PHOTOVOLTAICAC DISCONNECTLABEL LOCATION:AC DISCONNECTCODE REF: NEC 690.13(B)LABEL- 9:LABEL- 10:LABEL LOCATION:MAIN SERVICE PANELSUBPANELAC DISCONNECTCODE REF: NEC 690.54RATED AC OUTPUT CURRENTPHOTOVOLTAICAC DISCONNECTNOMINAL OPERATING AC VOLATGE240 VWARNING!POWER SOURCE OUTPUTCONNECTION. DO NOTRELOCATE THISOVERCURRENT DEVICEMAIN PHOTOVOLTAICSYSTEM DISCONNECTLABEL LOCATION:MAIN SERVICE DISCONNECT (ONLY IF MAIN SERVICE DISCONNECT IS PRESENT)CODE REF: NEC 690.13(B)LABEL- 11:62.92 A MSP UM CBACDJBJBJBSUB REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARPLACARDPV-9LABELING NOTES:1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACTREQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS.2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE, OSHA STANDARD 19010.145, ANSI Z535.3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21]5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLYAFFIXED [IFC 605.11.1.1]POWER TO THIS BUILDING IS ALSO SUPPLIED FROM MULTIPLESOURCES OF POWER WITH SAFETY DISCONNECTS AS SHOWN:CAUTIONDIRECTORYPERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THESERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM.(ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS OUTLINED WITHIN:NEC 690.56(B)&(C), [NEC 705.10])PER FFPC 11.12.2.1.49168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986(N) PV ARRAY(N) ENPHASE COMBINER BOX(N) AC DISCONNECT(N) JUNCTION BOX (TYP.)(E) UTILITY METER/MAIN COMBO(E) SUBPANEL (INSIDE GARAGE) REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLARMICRO INVERTER CHARTMICRO INVERTER CHART1-1023411-2021-3031-4041-5051-60561-706789101PV-10 REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLAREQUIPMENTSPECIFICATIONPV-11 REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLAREQUIPMENTSPECIFICATIONPV-12 REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLAREQUIPMENTSPECIFICATIONPV-13 REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLAREQUIPMENTSPECIFICATIONPV-14 REVSHEET NAMESHEET SIZESHEET NUMBERHAROLD MORRIS RESIDENCE 9168 PUMPKIN RIDGE, PORT ST. LUCIE, FL 34986ANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAME & ADDRESSDRAWN BYESRSUNTRUST TOWER401 E. JACKSON ST. SUITE 3300TAMPA, FL 3360201/25/2022INITIAL DESIGNMODERN CONCEPTS SOLAREQUIPMENTSPECIFICATIONPV-15