Loading...
HomeMy WebLinkAboutInstruction Page (Section A ,C , D+He U®PY EE E LUCIE WORK ST. LUCIE COUNTY ST LUCIE COUNTY RO I , 64 M4jjffVATION.SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building FB 0 INSTRUCTION PAGE ��� COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET 9 APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,394,5,6,7 Metal Roofs A, B, D Wood Shingles and Shakes A, B, D IA4,5,6,7 Other As Applicable 1,2,304,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST LUCIE WORKS :KS Master Permit No. 2201-0450 Section A (General Information) Process No. Contractors Name: Rlchie the Roofer & Co. Inc. License # CCCO58021 Job Address 390 Baysinger Ave., Fort Pierce, Florida ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles ❑ Metal Panel/Shingles QWood Shingles/Shakes ❑ Prescriptive BUR-RAS. 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance XReroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 112 sq ft Steep Sloped Roof Area (SF) 880 sq ft Total (SF) 992 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. LUCIE -WO.Fil"S Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") System Manufacturer: Polyglass Product Approval No.: FL1654 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: 90 Deck: Type: wood Gauge Thickness: 15/32 Slope: Flat Anchor/Base Sheet & No. df Ply(s): self Adhering 1 ply Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): SBS -SA Base Sheet Fastener/Bonding Material: self Adhering Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: APP Self Adhering Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base.Sheet Attachment: Zone 1' " oc @ Lap, # Rows_ ® "o " Zone 1:—" oc @ Lap, # Rows - ® woo Zone 2:_. _." oc. @ Lap, # Rows @ " 0 " Zone 3• " oc @ Lap, # Rows_ @ — oc Number of Fasteners Per Insulation Board: Zone 1' Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section D (Steep Slope Roof System) Roof system Manufacturer: owens corning titanium PSU30 FL11602 peel-n-stick, Dynamic Metals FL27499R4 Notice of Acceptance Number: FL11602 and FL27499R4 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: 'Zone 2e: Zone 2n:-Zone 2r:Zone 3e: Zone 3r: Roof Slope: 4 12 Ridge Ventilation? N/A Deck Type: 19/32" Plywood Type Underlayment: I Peel-n-stick Insulation:. N/A Fire Barrier: Fastener Type & Spacing: #10 Screw with Weather -seal_? sheiMcm - Adhesive Type: Type Cap Sheet Mean Roof -Height: 15 ft Roof Covering: 5V metal Type & Size Drip 2 2, Edge: