HomeMy WebLinkAboutLetter ( Glass Door Replacement )I - Advanced Architecture & Planning LLC File COPY Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 December 11, 2021 Bill Laprade Glass Professionals, Stuart, Florida Cell: 772-745-3459 Project: Phelan Residence 13432 Harbour Ridge Blvd #8b Palm City, FL 34990 Dear Mr. Laprade: For the above address, the (1) sliding glass door to be replaced with PGT Industries, Series SGD-770, the minimum required wind pressures below are based on FBC 2020 wind load calculations. The applied wind pressures are as follows for the proposed replacement glazed unit for Exposure C, per below and NOA: 20- 04029.09 Series: Door or Window: Height Wind Zone: Applied Wind Pressure: SGD-770 119"x 91.5" 20 ft 5 . +34.8 / -42.6 psf The (2) mullions SH-5500, by PGT Industries, NOA 20-0406.03 tributary loading meets above applied presuures tranfered from the SGD to the (2) side locations. In reviewing respective NOA for the above sliding glass door and mullions, the calculated respective design pressures are less than the respective minimum allowable pressures and as such are acceptable to this office. If you have any questions, please contact me at any time. Thank you, Raymond Chladny, B.arch.Sc., _ M.arch, AIA, NCARB, Lic.#: AR-0017475 ze-- GLASS (Next Unit Over) Product Approvals PGT SGD 770 NOA# 20-0429.09 PGT Mullbar NOA# 20-0406.03 File COPY I I (Covered Porch) I I I I OPG 1 PGT SGD 770 119 1/4" X 91 1/2" 2X6MuIl 2X6Mull pr9ject flame: St Lucie County License No.: 19363 Phelan Residence 07/i 574w 15452 Harbour Ridge Blvd #8B Palm City. vt 54990 $570 S.E. ®rose 11wy Stuart. ft 54997 plc (9 9s A mail. 7 (772) Z86-0�159 • 910"Pf0FeFIienCli@9meil.Com phelen999s@gmeil.com Scale: N.T.S. Off