HomeMy WebLinkAbout11 Concrete Placement - South Bldg (1-31-22)607 NW Commodiry Cove. Port St. Lucie. Florida 34986
NEERING SCIENCES
GFA PROJECT#
3310.2100348.0000
PROJECT
Cristelle Cay Condos
4804 N. A1A
LOCATION
Fort Pierce, FL 34949
PERMIT NO.
South Building - 1908-0215
OWNER
Cardinal Ocean Development, LLC
WEATHER
CONTRACTOR
Cardinal Ocean Development, LLC
TEMPERATURE
ARCHITECT
Frank C Snedaker
WIND
ENGINEER
Stirling 8 Wilbur Engineering
HUMIDITY
924-3580
CONCRETE PLACEMENT
INSPECTION REPORT
DATE Monday, January 31, 2022
S M T W TH F S
DAY x
BRIGHT SUN
CLEAR
OVERCAST
RAIN
x
BELOW 60
60-75
75-90
ABOVE 90
x
LOW
MODERATE
HIGH
Report No
x
LOW
MODERATE
HIGH
11
x
MEMBERS/AREA INSPECTED: Area Inspected (1) / Concrete placement monitoring / South building 2nd floor concrete slab.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
x
1 SPARE VIBRATOR ON HAND
x
2 FORMS WETTED/OILED
It
3 CONCRETE TICKET SHOWS CORRECT MIX DESIGN (SEE TABLE BELOW)
It
4 CONCRETE SLUMP ON TRUCKS WITHIN SPECIFICATIONS (SEE TABLE BELOW)
x
5 TEST CYLINDERS MADE EVERY 50 YARDS OR DAY'S POUR
x
6 PLACEMENTS COMPLETED WITHIN 90 MINUTES FROM BATCH TIME
x
7 CONCRETE DISCHARGE HEIGHT ADHERED TO 8 FEET
x
8 SUFFICIENT VIBRATION PERFORMED
x
9 STEEL REMAINED IN PLACE DURING POUR
x
10 P/T CABLES REMAINED IN PLACE AND WITHOUT SHARP BENDS
Disposition of Inspection
x Section / Area Observed Re -Inspection
Work In Progress RRe-Inspection Required
COMMENTS/ACTION REQUIRED: Slump taken every 50 cv within soec's
Inspection Performed By:. (d I,Aa 1 .E fi19 '• %''
Inspection Certified By: -`•4053
auI - onn,
Registered Professional No: . 144653
Certified Special Inspector No: SI 1103 L, Z'
FBPE Certificate No: 4930 ,-