HomeMy WebLinkAboutDUPONT Florida Building Code Onlinehttps://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtbxPqODTr%2bX6LbKICltDIK%2bREhnyvpM2JKEKWrhI1kqw%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL20876-R2
Application Type Revision
Code Version 2020
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer DUPONT
Address/Phone/Email 5401 Jefferson Davis Highway
Richmond, VA 23234
(812) 212-4429
melissa.s.grant@dupont.com
Authorized Signature Melissa Grant
melissa.s.grant@dupont.com
Technical Representative Melissa Grant
Address/Phone/Email P.O. Box 103
202 E. Washington Street
Morris, IL 60450
(812) 212-4429
melissa.s.grant@dupont.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity Intertek Testing Services NA, Inc.
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Intertek Testing Services NA, Inc.
Certificate of Independence
Referenced Standard and Year (of Standard)Standard Year
ASTM D226 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option C
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtbxPqODTr%2bX6LbKICltDIK%2bREhnyvpM2JKEKWrhI1kqw%3d%3d 2/2
Date Submitted 01/27/2021
Date Validated 01/27/2021
Date Pending FBC Approval
Date Approved 01/29/2021
Summary of Products
FL #Model, Number or Name Description
20876.1 Dupont Protec Underlayment 120,160, 200
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Installation Instructions
FL20876_R2_II_K29385 Tyvek Protec Install Guide.pdf
Verified By: Intertek Testing Services NA, Inc.
Created by Independent Third Party:
Evaluation Reports
FL20876_R2_AE_2021-01-26 CCRR-1062.pdf
20876.2 Dupont Tyvek Underlayment Roof Protector
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other:
Installation Instructions
FL20876_R2_II_SC00501-Tyvek Roof Protector Brochure.pdf
Verified By: Intertek Testing Services NA, Inc.
Created by Independent Third Party:
Evaluation Reports
FL20876_R2_AE_2021-01-26 CCRR-1087.pdf
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
NOA No.: 19-1203.01
Expiration Date:07/23/25
Approval Date:07/23/20
Page 1 of 4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
DuPont de Nemours, Inc.
5401 Jefferson Davis Highway, Donnelly Building
Richmond, VA 23234
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: DuPont™ Roof Protector™ Roofing Underlayment
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 19-1203.01
Expiration Date:07/23/25
Approval Date:07/23/20
Page 2 of 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: Polypropylene
SCOPE:
This approves, DuPont™ Roof Protector™ Roofing Underlayment, as described in this Notice of Acceptance;
designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building
Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product
Dimensions
Test
Specification
Product
Description
DuPont™ Roof
Protector™ Roofing
Underlayment
42" x 286' rolls
20 lbs. per roll
ASTM D226 Type
I & II
Four layer synthetic UV stabilized polymeric
underlayment comprised of a nonwoven top layer
which is laminated to a woven scrim and having a
slip resistant bottom coating.
MANUFACTURING LOCATION:
1.) LANGLEY, B.C., CANADA
.
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Test Name/Report Date
Intertek Testing Agency 104250542COQ-002 Physical Properties 4/29/2020
ASTM D 226
NOA No.: 19-1203.01
Expiration Date:07/23/25
Approval Date:07/23/20
Page 3 of 4
INSTALLATION SPECIFICATIONS: (Double Layer: Slopes of 2:12 to 4:12)
DuPont™ Roof Protector™ Roof Underlayment
1. DuPont™ Roof Protector™ Roof Underlayments shall be installed in strict compliance with applicable
Building Code.
2. DuPont™ Roof Protector™ Roof Underlayments shall be installed in a double layer beginning with a 26”
undercourse strip parallel to the eave edge, and then cover with the full width sheet. Overlap successive sheets
by 26”.
3. DuPont™ Roof Protector™ Roof Underlayments shall be fastened with a minimum 4” side lap and a 6” end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and shall be attached to
a nailable deck in a grid pattern of 12 inches (305 mm) between the overlaps, with 6-inch (152 mm) spacing at
the overlaps..
4. DuPont™ Roof Protector™ Roof Underlayments may be used with Asphaltic shingles, Wood shakes and
shingles, Non-structural metal roofing, and quarry slate.
5. For fire classification of specific roof assemblies using DuPont™ Roof Protector™ Roof Underlayments
refer to a current Approved Roofing Materials Directory for fire ratings of this product.
INSTALLATION SPECIFICATIONS: (Single Layer: Slopes of 4:12 or greater)
DuPont™ Roof Protector™ Roof Underlayment
1. DuPont™ Roof Protector™ Roof Underlayments shall be installed in strict compliance with applicable
Building Code.
2. DuPont™ Roof Protector™ Roof Underlayments shall be installed with a minimum 4-inch horizontal lap
and 6-inch vertical laps in a shingle layer fashion. Vertical laps in a succeeding course shall be staggered from
those in preceding course by minimum 6-feet.
3. DuPont™ Roof Protector™ Roof. Underlayment shall be attached to a nailable deck in a grid pattern of 12
inches (305 mm) between the overlaps, with 6-inch (152 mm) spacing at the overlaps.
4. DuPont™ Roof Protector™ Roof Underlayments may be used with Asphaltic shingles, Wood shakes and
shingles, Non-structural metal roofing, and quarry slate.
5. For fire classification of specific roof assemblies using DuPont™ Roof Protector™ Roof Underlayments
refer to a current Approved Roofing Materials Directory for fire ratings of this product.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
NOA No.: 19-1203.01
Expiration Date:07/23/25
Approval Date:07/23/20
Page 4 of 4
LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code.
3. DuPont™ Roof Protector™ Roof Underlayments shall be applied to a smooth, clean and dry surface with
deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any
loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application.
4. DuPont™ Roof Protector™ Roof Underlayments shall not be hot mopped, refer to manufacturer’s published
literature for product compatibility.
5. DuPont™ Roof Protector™ Roof Underlayments shall not be left exposed as a temporary roof for longer than
30 days of application.
6. DuPont™ Roof Protector™ Roof Underlayments are components used in roof system assemblies. Roof
system assemblies are approved under a specific Notice of Acceptance. Refer to Prepared Roofing system
Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing
products.
7. DuPont™ Roof Protector™ Roof Underlayments may be used with any approved roof covering Notice of
Acceptance listing DuPont™ Roof Protector™ Roof Underlayments as a component part of an assembly in
the Notice of Acceptance. If DuPont™ Roof Protector™ Roof Underlayments are not listed, a request may
be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department
for approval provided that appropriate documentation is provided to detail compatibility of the products, wind
uplift resistance, and fire testing results.
8. All products listed herein shall have a quality assurance audit in accordance with the Florida Buil ding Code and
Rule 61G20-3 of the Florida Administrative Code.
9. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
END OF THIS ACCEPTANCE